Indian Tenders

Tender Notice

TDR 55579768
Tendering Authority Military Engineer Services
Tender No GE/CHM-26/2026-2027
Tender ID 2026_MES_766430_1
Tender Brief Corrigendum : Tender For Repair & Maintenance Of Internal Electrification With Allied Work In Otm Accn In The Aor Of Age B/R-I Under Ge Chandimandir.
City Chandimandir
State Haryana
Document Fees INR 500 /-
EMD INR 70000.0 /-
Tender Value INR 35 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Repair & Maintenance Of Internal Electrification With Allied Work In Otm Accn In The Aor Of Age B/R-I Under Ge Chandimandir.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 08-06-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-06-2026

Key Dates

Publish Date 08-06-2026
Last Date of Bid Submission 15-06-2026
Tender Opening Date 17-06-2026

Contact Information

Company Name Military Engineer Services
Contact Person Garrison Engineer
Address Garrison Engineer Chandimandir panchkula Haryana 134107

BOQ Items

Name of Work:- REPAIR & MAINTENANCE OF INTERNAL ELECTRIFICATION WITH ALLIED WORK IN OTM ACCN IN THE AOR OF AGE B/R-I UNDER GE CHANDIMANDIR.
Sl. No. Item Description
1Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
2Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in existing PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : (i) Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original surface and nothing extra shall be paid on this account. (ii)Unit rate is inclusive of cutting chases in wall /foor/PCC for sunken box and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account.
3All as per serial item 02 herein before but for socket outlet 3 pin 5 Amps on same board complete all as specified and directed
4All as per serial item 02 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed
5All as per serial item 02 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor
6Material and labour for point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account. Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account.
7All as per serial item 6 herein before but for socket outlet 3 pin 6Amps on same board complete all as specified and directed
8All as per serial item 6 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed
9All as per serial item 6 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor, complete all as specified and directed
10Switch modular type (ISI marked), single pole, one way 6 Amps, one module (ISI marked), complete all as specified & directed.
11Switch modular type (ISI marked), single pole, one way 16 Amps, one module (ISI marked), complete all as specified & directed.
12Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed.
13Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed.
14Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed.
15Modular switch type bell push, single pole, 230 volt two module,(ISI marked) complete all as specified and directed.
16Electric Bell, multi music type, AC, 230 volts, single pole all as specified and directed by Engineer-in-charge.
17Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specified and directed by Engineer-in-charge.
18Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed.
19LED Bulb 09 watt self ballasted Retrofit type lamp with PBT body shell and DC diffuser CCT 6500 K complete all as specified and directed.
20LED lights fitting, 4 feet, 1x 20W, inverter rechargeable, inbuilt lithium ion battery with charging time 8 to 10 hrs & back up time minimum 4 hrs, 220V, AC decorative box type with driver, holder including LED tube light connecting up with flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed.
21LED lights fitting, 2 feet, 1x 10W, inverter rechargeable, 220V, AC decorative box type with driver, holder including LED tube light connecting up with flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed.
22LED Mirror/wall Lights fitting 17 watt cool/warm white of approx size near to 534 x 93 x 33 mm , 220V AC decorative/model ultorn type including fitting fixed on wall/ceiling and connecting up complete with flexible cable white of suitable size and making necessary connection fixed as in repair complete all as specified and directed.
23LED Industrial outdoor type Bulkhead luminaires,IP rating not less than 45, highly resistant to dust and water 1 x 9/10 Watt fitting in engineering plastic housing with clear prismatic diffuser complete with all accessories and connecting up with flexible cable white of suitable size and making necessary connection fixed as in repair complete all as specified and directed.
24LED 12 W recess/surface mounted indoor type back lit downlighter suited for any modern workspace of size not less than 6\\" round/square, fixed as in repair complete all as specified and directed.
25LED building security light fitting 1 x 35 Watt new generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP65 protection incl mounting bracket of suitable size and connection fixed as in repair complete all as specified and directed.
26Switch modular type (ISI marked), single pole, one way 6 Amps, one module (ISI marked), fixed as in repair complete all as specified & directed.
27Switch modular type (ISI marked), single pole, one way 16 Amps, one module (ISI marked), fixed as in repair complete all as specified & directed.
28Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), fixed as in repair complete all as specified & directed.
29Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), fixed as in repair complete all as specified & directed.
30Modular switch type stepped fan regulator, single pole, 230 volt two module fixed as in repair complete all as specified & directed.
31Modular switch type bell push, single pole, 230 volt two module,(ISI marked) fixed as in repair complete all as specified & directed.
32Modular white cover plate with frame and metal flush box, suitable for 2 module, fixed as in repair complete all as specified and directed.
33Modular white cover plate with frame and metal flush box, suitable for 3 module, fixed as in repair complete all as specified and directed.
34Modular white cover plate with frame and metal flush box, suitable for 4 module, fixed as in repair complete all as specified and directed.
35Modular white cover plate with frame and metal flush box, suitable for 6 module, fixed as in repair complete all as specified and directed.
36Modular white cover plate with frame and metal flush box, suitable for 8 module, fixed as in repair complete all as specified and directed.
37Modular white cover plate with frame and metal flush box, suitable for 12 module, fixed as in repair complete all as specified and directed.
38Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed.
39Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.
40Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.
41Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. NOTE FOR SERIAL ITEM NO 39 to 41: (i) Two runs of cable, one run of earth wire shall be considered as one running metre(ii) Cutting chases & Conduit will be measured and paid separtely(iii) colour code shall be Red for phase, Black for neutral and green for earth
42Sub main wiring with four single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade (with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit of suitable size, cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. NOTE :(i) Four runs of cable, one run of earth wire shall be considered as one running metre(ii) Cutting chases & Conduit will be measured and paid separtely(iii) colour code shall be Red for phase, Black for neutral and green for earth
43Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth Complete all as specified and directed .
4420 to 25 mm dia, rigid non metallic PVC concealed conduit, 'ISI marked', inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, complete all as specified
4532 mm dia, rigid non metallic PVC concealed conduit, 'ISI marked', inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, complete all as specified
46Disconnecting the power supply and taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCB's ,MCB's etc and removing from site, Complete all as specified and directed .
47Vertical TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 250 Amps & outgoing 4 way having IP 43 protection Complete all as specified and directed .
48MCB DB, TPN 4 Way , IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, with provision for MCBs including connecting with 200 Amps busbar and din rail neutral link completed all as specified and directed.
49MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, (2 + 10 way) 12 way SPN with 200 Amps busbar 240V completed all as specified and directed.
50MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, (2 + 6 way) 8 way SPN with 200 Amps busbar 240V completed all as specified and directed.
51MCCB, 125 Amps, four pole, 3 phase , 16KA, 415 volt with adjustable thermal and maganetic release, with proper thimble complete all as specified and directed
52MCCB, 200 Amps, four pole, 3 phase , 25KA, 415 volt with adjustable thermal and maganetic release, with proper thimble complete all as specified and directed
53MCB, TPN , 415 volt, 63 Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
54MCB, SPN , 240 volt, 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
55MCB, SP , 240 volt, 40 to 63Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
56MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
57Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one number single pole MCB 20 Amps , 240 Volts for AC/Geyser point complete all as specified and as directed.
58Casing capping with fixing accessories of size 20mm width fixed as in repair complete all as specified and directed .
59PVC insulated and unsheathed FRLSH cable of size 1.5 sqmm, fixed as in repair compelte all as specified and directed.
60PVC insulated and unsheathed FRLSH cable of size 2.5 sqmm, fixed as in repair compelte all as specified and directed.
61Fabrication, install, testing and commission of wall mounted sheet metal busbar chamber CPRI approved, grouted with nut and bolts (with proper locking arrangement and holes to distribute circuits) of size 600x500x300mm with copper strip 40mm x 6mm (04 Nos) of length 450mm with approved colour coded and PVC adhesive coated, IP-54 as per IS-13947 protection fixed on insulator with the help of nut/bolts including provison of 04 Nos 08 mm dia hole with 8 mm dia 50 mm long nut/bolts with 02 Nos of washer connected with 16 sqmm single core colour coding stranded copper cable with thimble/lugs including one MCCB, 125 Amps, four pole 3 phase 25 KA, 415 volt with adjustable thermal and megnetic release complete having adjustable type base frame and equal space around MCCB as incommer one No, making good distrubed surfaces to match with original all as specifed and directed
62Fabrication, install, testing and commission of wall mounted sheet metal busbar chamber CPRI approved, grouted with nut and bolts (with proper locking arrangement and holes to distribute circuits) of size 600x500x300mm with copper strip 40mm x 6mm (04 Nos) of length 450mm with approved colour coded and PVC adhesive coated, IP-54 as per IS-13947 protection fixed on insulator with the help of nut/bolts including provison of 04 Nos 08 mm dia hole with 8 mm dia 50 mm long nut/bolts with 02 Nos of washer connected with 16 sqmm single core colour coding stranded copper cable with thimble/lugs including one MCCB, 200 Amps, four pole 3 phase 25 KA, 415 volt with adjustable thermal and megnetic release complete having adjustable type base frame and equal space around MCCB as incommer one No, making good distrubed surfaces to match with original all as specifed and directed
63Linear LED luminaire 80W (Surface type) for squash court made of high-quality extruded aluminium housing with superior thermal management and finished in white colour, luminaire shall be provided with a high-transmission polycarbonate (PC) diffused cover ensuring uniform and glare-free illumination, IP66 with high-efficiency LED modules delivering not less than 8800 lumens output, dimension should be 2400 x 75 x 125 (+/- 10%) including complete arrangement of scaffolding/labour/T&P for fixing the fitting on the high-top squash court roof, fixed as repair complete all as specified and directed by Engr-in-Charge.
64LED Highbay luminaire 1 x 80 watt for indoor type sports complex (suspended type) with a housing of High Pressure Die casted Aluminium and polycarbonate front cover, luminaire shall be compliant with IP65 classification and impact protection of IK08 to ensure durablility, uniform distribution connecting up complete with suitable size PVC insulated wire ISI marked, including complete arrangement of scaffolding/labour/T&P for fixing the fitting on the high-top sports complex roof, fixed as repair complete all as specified and directed by Engr-in-Charge.
65Recess/Surface mounted LED, 1' X 1', 15 watt, cool day/warm white light, edge lit tile in extruded aluminium / CRCA steel sheet powder coated housing with full opal diffuser suitable for perfect lighting complete as per sample, fixed as in repair complete all as specified and directed.
66Recess/Surface mounted LED, 2' X 2', 36 watt, cool day/warm white light, edge lit tile in extruded aluminium / CRCA steel sheet powder coated housing with full opal diffuser suitable for perfect lighting complete, fixed as in repair complete all as specified and directed.
67Recess/ Surface mounted LED, 1' X 4', backlit panel light, 36 watt, cool day/warm white light, full glow having white powder coated CRCA body with high quality opal diffuser suitable for perfect lighting complete, fixed as in repair complete all as specified and directed.
68Decorative outdoor wall light LED 12 Watt warm white, mygarden type black & stainless steel body, Flush Mount type, IP44, protection complete as per sample fixed as in repair complete all as specified and directed.
69Decorative, wall mounting fixture, in durable plastic body & designer mesh in gold finish suitable for 9 W LED lamp pettren Glaze type as per sample fixed as in repair complete all as specified and directed.
70LED Sleek modern, wall Lights fitting 24 watt 220V AC, Scene switch type cool/warm white of approx size near to 868 x 93 x 33 mm, polycarbonate body, decorative, model ultorn type including fitting fixed on wall/ceiling and connecting up complete with flexible cable white of suitable size and making necessary connection as per sample fixed as in repair complete all as specified and directed.
7132mm dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS 14930 Part-II with anti rodent and non flame propogating properties of approved colour with fittings for cable protection, complete all as specified and directed
72XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm, 4 core, fixed as in repair complete all as specified and directed.
73Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways complete all as specified & directed. Please Enable Macros to View BoQ information

Other Detail

Information Source https://defproc.gov.in/nicgep/app
Download FileName File Description File Size
Download 9cf0bc04-69cb-483b-8958-1b904ec581c1.html Tender Documents 0 KB
Download BOQ_858369.xls Tender Documents 0 KB
Download Tendernotice_1 (2).pdf Tender Documents 0 KB
Download Tenderpages26.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.