Tender For Providing Of Or Line With Chs At Khalsar Under Ge 873 Ews.-- 1 Note: Schedule ‘A’ Part - I To Part -X Are Prepriced By Mes. Bidders Shall Insert Their Lumpsum Amount In The Green Coloured Field Under Col-6 Only. 2 Total Amount Of Sch A Part - I (Building Works) 3 Total Amount Of Sch A Part - Ii (Site Clearance Excavation And Earth Works) 4 Total Amount Of Sch ‘A’ Part - Iii (Internal Water Supply) 5 Total Amount Of Sch ‘A’ Part - Iv (Internal Electrification) 6 Total Amount Of Sch ‘A’ Part - V ( Ro Plant) 7 Total Amount Of Sch ‘A’ Part - Vi (Road, Path, Hardstanding & Culvert Works) 8 Total Amount Of Sch ‘A’ Part - Vii (Sewage Disposal) 9 Total Amount Of Sch A Part - Viii (External Electrification) 10 Total Amount Of Sch ‘A’ Part -Ix ( Extrnal Water Supply Works) 11 Total Amount Of Sch ‘A’ Part - X (Hot Water Supply) 12 Sch A Part - Xi (Miscellaneous B/R And E/M Works For Sch A Part-Ii To Part-X)Note: This Schedule Is Not Pre-Priced By Mes And The Rate Indicated As \Rs 0.00\ Under Col 5 Signifies This Fact Only

Key Dates

Publish Date 19-05-2026
Last Date of Bid Submission 24-06-2026
Tender Opening Date 27-06-2026

Contact Information

Company Name Military Engineer Services
Contact Person HQ CE LEH ZONE
Address HQ CE LEH ZONE, PIN - 901205, c/o 56 APO

BOQ Items

Name of Work:-
Sl. No. Item Description
1NOTE: Schedule ‘A’ Part - I to Part -X are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
2Total amount of Sch 'A' Part - I (BUILDING Works)
3Total amount of Sch 'A' Part - II (SITE CLEARANCE EXCAVATION AND EARTH WORKS)
4Total amount of Sch ‘A’ Part - III (INTERNAL WATER SUPPLY)
5Total amount of Sch ‘A’ Part - IV (INTERNAL ELECTRIFICATION)
6Total amount of Sch ‘A’ Part - V ( RO PLANT)
7Total amount of Sch ‘A’ Part - VI (ROAD, PATH, HARDSTANDING & CULVERT WORKS)
8Total amount of Sch ‘A’ Part - VII (SEWAGE DISPOSAL)
9Total amount of Sch 'A' Part - VIII (EXTERNAL ELECTRIFICATION)
10Total amount of Sch ‘A’ Part -IX ( EXTRNAL WATER SUPPLY WORKS)
11Total amount of Sch ‘A’ Part - X (HOT WATER SUPPLY)
12SCH 'A PART - XI (Miscellaneous B/R and E/M works for Sch 'A' Part-II to Part-X)Note: This schedule is not pre-priced by MES and the rate indicated as \\"Rs 0.00\\" under Col 5 signifies this fact only
13M&L for RCC Septic tank designed to carry sewage and sullage water, excavation in hard/dense soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft, manhole openings with cover connection etc.,complete all as specified and directed.
14M&L for Construcion of Soakage well of size 3.00mtr dia and 3.0mtr deep excavation in hard/dense soil, foundation in PCC 1:3:6, well of honey combed and solid in M-25 concrete, including intercepting chamber, screen chamber stone masonry in CM, RCC cover slab in M-25/RR Masonry/Filling with brick bats complete all as specified and directed.
15Oil Fired Hot Water Generator : Supply, Installation, Testing & Commissioning of Oil Fired Glycol based Hot water generator of cap 4 Lac Kcal/Hr using HSD oil complete with combustion chamber and equipment automatic monoblock burner assembly, fire tubes, control panel with sequence controller, photo cell for flame failure, HT transfer electrodes, blower assembly, electric Panel, mounting frame, pressure gauges at inlet and outlet suitable for operation on 50 Hz, three phase, 440 volts AC supply. The Burner should comply as per ISO or equivalent standard. Inlet temp of fluid should be as per site requirement and the boiler shall be able to deliver fluid with maximum outlet temp 90°C. The saftey valves for the Boiler are to be included in price including the following :- Note :- Out of the total Qty of 03 Nos, 02 shall be working and 01 No. shall be stand by. (a) All neccessary accessories required for the proper functioning of Hot Water Genearator are included in price.(b)The prices should include lifting, shifting and positioning of units at Site.(c) Hot Water Genearator installation to be done as per Manufacturer's recommendation with all installation requirements i.e Foundation, Vibration Isolator,Insulation etc as recommended by Manufacturer for the Ambient Temperature of Site. Installation of Hot Water Genearator is included in quoted price which includes the Civil Structure, Mechanical Structure etc as recommended by Manufacturer.
16Supply, Installation, Testing & Commissioning of MS Flue Gas Exhaust Pipe made out of 3 mm thick MS sheet, minimum 1.2 m above the highest point of the plant room and including connection from HT Water generator to main vertical exhaust pipe fabricated from 3 mm MS sheet to be connected to common exhaust pipe header from 3 mm of suitable Diameter. The Hot water generator’s shall be connected to a independent flue gas exhaut pipe of suitable size and as per manufacturers guide lines. The portion of the flue gas exhaust pipe in side the building shall be insulated with 25 mm Mineral wool of 24 kg/cun with GI cladding of 26 gauge. (The item shall be complete with mounting/fixing arrangement) complete all as specified and directed by OEM in Consultantion with Engineer - In - Charge
17GLYCOL CIRCULATION CENTRIFUGAL PUMPS: Supply, Installation, Testing & Commissioning of flow 250 USGPM, Head 30 mtr Axial Split Coupled Vertical Inline water pump set with Cl casing, Bronze Impeller, SS Shaft and externally flushed outside type balanced mechanical seal shall be suitable to sustain a fluid temperature of -25 Degree Celcius to 120 Degree Celcius. and non overloading motor, as per specifications and drawings. with Suitable HP, TEFC squirrel cage induction motor with IE3, type class 'F\\" insulation, Motor shall be |rating of IP 55, operating on 415 +10% volts, 3 phase, 50Hz AC Supply , including suitable capacity motor starter contoller encloser with Ammeter and voltmeter AC-3 phase The external flush line must be used for the purpose of heat dissipation from the mechanical seal. Pumps with antivibration pads (In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation) . Cement concrete foundation for the pump unit. (In case pumps are inline, foundation shall as per Manufacturers commendation complete all as specified and directed
18EXPANSION TANK and Pressurisation Unit:Supply, Installation, Testing and commissioning of INSULATED PRESSURISED CLOSEDWATER EXPANSION TANK 500 Lts capacity suitable for total volume of Glycol - Water Solution, circuitalong with necessary accessories such as along with necessary accessories such as 2 Nos suitable capacity pumps (1working +1standby) .with Pressure Transmitter and interconnecting Pipe & Isolating Valvecomplete with piping connections, safety relief valve, drain valve, pressure gauge, automatic airpurging arrangement, etc. The tank shall be pre-charged. Expansion tank Shall be with replaceableheavy duty butyl rubber bladder. The tank connection's should be as per OEM recommendationsand 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in thetank. The tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation.The tank must be constructed in accordance with IS-STANDARD 2825-1969 (with lates Revision) and Rated at PN 16 and ASME Stamped. The complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system. The tank shall be duly painted in approved colour complete with pressure switches and control panel IP55 Control Panel, Pressure Transmitter, interconnecting piping & wiring. (Tank capacity 500 Ltrs). Hot Glycol - Water closed vessel pressurized expansion tank as described above shall be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material or Equivalent U value Insulating Material and cladded with aluminium Sheet (20G).
19Expansion Tank of 500 Ltr Capacity all as per above mentioned
20PRESSURIZATION UNIT: pumpset with Control Panel and other connected accessories
21Make Up TANK:Supply, installation, testing and commissioning of factory made Make up Water Tank, Rectangular/Circular shape, of 4 mm thick MS sheet (IS 2062), of capacity of 550 litres for Pocket- 1 complete with inlet, outlet, overflow, drain pipe of MS and vent with flame arrestor. Tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1500mm) above FFL. Service platform shall be provided as per recommendations of OEM. The tank shall be provided with remote indication of levels provided level switches for on- off operation of tranfer pump. Extra high level and extra low level alarm shall be provided. Tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.Note:- Make up Water tank as described above should be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material and cladded with aluminium Sheet (20G).
22DAY OIL STORAGE TANK/DIESEL TANK:Supply, installation, testing and commissioning of Diesel tank, Rectangular/Circular shape of 4 mm thick MS sheet (|S 2062), of capacity of 550 |litres for Pocket-1 complete with inlet, outlet, overflow, drain pipe of MS and vent with flame |arrestor. Ttank will be provided with supports made out of minimum 50mm angle iron duly painted, keep tank base at minimum 2250 mm above FFL service platform shall be provided as per rccommendatios of OEM. The tank shall be provided with remote indication of levels provided with level switches for on-off operation of tranfer pump. Extra high level and Extra low |level alarm shall be provided. Tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
23Supply, Erection, Testing and Commissioning of Diesel Transfer pumps for the capacity of 5 LPM 5 meter head for Diesel Oil transfer with base frame foundation, bolts coupling guard, TEFC, (OEM design HP for the required Flow and Head ) and other accessories for proper function of the pump.
24Supply, Installation, Testing and Commissioning of Ceiling Suspended Fan Coil Unit having casing with bottom return Air Plenum complete including Direct driven fan (three speed) motor, operated on 230 volts, single phase, 50Hz, AC supply. Unit to be provided with inbulit 2 way wall with cordless remote. The Ball Valve with Strainer at inlet and outlet of FCU and copper pipe for connection up to 10 feet should be provided. The Unit Capacity should be calculated as per BIS/ Eurovent Standard/AHRI Certification method. The below desired capacity should be calculated at Altitude of 3600 mts above sea level. Capacity calculation sheet to be provided to Engineer in Charge. The below mentioned capacity is at INLET TEMP: 75 Degree Celcius , OUTLET TEMP: 65 Degree Celcius and Below Mention External Static Pressure (ESP). Air Flow Should be sufficient for the air circulation inclunding the External Static Pressure.
255 kW, ESP: 50 Pa (CHS Plant Room - Duty - 1 Qty each)
266 kW, ESP: 50 Pa (GF - 3 OR's & Commom Room - 1 Qty each)
278 kW, ESP: 50 Pa (FF - 3 OR's & FF Commom Room - 1 Qty each)
2812 kW, ESP: 100 Pa (GF - 16 OR's : Qty - 4, FF Passage : Qty -2)
2916 kW, ESP: 100 Pa (GF - PASSAGE : QTY- 2, FF - PASSAGE : QTY- 2)
3018 kW, ESP: 100 Pa (GF - PASSAGE : QTY- 2, FF - PASSAGE : QTY- 2)
31Supply, Installation, Testing and Commissioning of Steel plate Radiator( Wall Mounted) confirming EN- 442 , working pressure range from 10-13 bar having working temparture of 110°C, complete with top grill side cover as standard along with inlet ,outlet valve, Air purge valve and with threaded plug, flow regulator as per OEM.The below desired capacity should be calculated at Altitude of 3600 mts above sea level. Capacity calculation sheet to be provided to Engineer in Charge. The below mentioned capacity is at INLET TEMP: 75 Degree Celcius, OUTLET TEMP: 65 Degree Celcius.
322.5 kW, Length is 1000 mm and Height is 600 mm of Radiator. (CHS Plant Room - Toilet - 1 Qty Each )
336 kW, Length is 1800 mm and Height is 900 mm of Radiator.(First Floor - Toilet)
3410 kW, Length is 3000 mm and Height is 900 mm of Radiator.(Ground Floor - Toilet)
35M&L for Pre - insulated MS pipe,Class 'C' having minimum thicknes of PUF insulation as mentioned below and of density 36 Kg/Cum and 26 gauge GI/AL cladding complete suitable for above ground as per sizes shown.The pipes should be insulated with closed cell puf of density 36±2 Kg/Cum of below mentioned thickness. The Pipe should be workable in the temp. range of - 50 Degree Celcius to 120 Degreec Celcius. Note:-The Pipes size 150mm below shall be M.S. ‘C’ class as per IS : 1239 and steel pipe heavy class as per IS: 3589, minimum 6.35 mm thick, .Insulation and Cladding can be done at site or pre insulated Based on Site Condition.
36125 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. ( inside building )
3780 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. ( inside building )
3865 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding.( inside building )
3950 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. ( inside building )
4040 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. ( inside building )
4120 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. ( inside building )
42125 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge ( Buried under ground/Exposed to Ambient:)
4380 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge
44Supply,Installation, Testing amd commissioning of PVC ( minimum 10kg/sqcm pressure rated) drain water piping complete with fittings(elbows,tees, reducers,sockets,u trap etc.) supports,jointing insulated with XLPE class O tubular insulation and any other item required to make the system compelete. Nominal diameters of pipe in mm as inducated below:
4525 mm dia pipe, Insulation thickness - 19 mm
4632 mm dia pipe, Insulation thickness - 19 mm
4740 mm dia pipe, Insulation thickness - 19 mm
48Supply, Installation, Testing Balancing & Commissioning of G.S.S rectangular/round ducting including plenum as reuired as per IS 655 - 2006 complete with gaskets, elbows, splitters, vanes, supports adjustable dampers, etc. as per approved drawings.(Factory Fabricated) The price shall include necessary scaffolding required for working at required height Hot dipped Galvanised with 120 GSM Zinc coating Thickness: 22 GAUGE Sheet.
49Supply and fixing of acoustic lining of supply air duct and plenum with 15 mm thick Supply and Application of Acoustic Insulation with Engineered Nitrile Rubber open cell foam with Density 140 - 180 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7, Air Erosion test for 10,000 fpm air velocity as per ASTM C 1071-05 and with built-in antimicrobial protection. The material should pass Fungi Resistance Test as per DIN EN ISO 846 Method A and Bacterial Resistance Test as per DIN EN ISO 846 Method C; to be applied using manufacturer's recommended Rubber based Adhesive in a blend of solvents.
50Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
51Supply and fixing of Flexible connection Duct.
52Supplying and installing following size of perforated painted with powder coating M.S. cable tray 150 mm width X 50 mm depth X 1.6 mm thickness with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/Ground/wall with M.S. suspenders including bolts & nuts, painting suspenders etc. as required
53Supplying, fixing, testing and commissioning of following diameter valves(PN-16 Rating) (Complete with Flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), strainers (Complete with flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), gauges etc for condenser water circulation as per specifications. Insulation thickness of valves should be equal to the Insulation of PUF and GI Cladding of Pipe Section Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings as specified.
54125 mm Ø Butterfly Valve
5580 mm Ø Butterfly Valve
5620 mm Ø Butterfly Valve
57Supply and fixing for Y - STRAINER (Insulated Valves) of Ductile CI Body flanged ends with stainless steel strainer for hot water circulation including Insulation thickness of valves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified.
5880 mm Ø Y STRAINER
5920 mm Ø Y STRAINER
60Supply and fixing for 80 mm NON - RETURN VALVE (NRV Insulated Valves) with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN -16 pressure rating for hot water circulation including Insulation thickness of valves should be equal to the Insulation of PUF and GI Cladding of Pipe Section assepcified.
61Supply and fixing for 20 mm Automatic Air Purge Valves for hot water circulation header as specified and required by Engineer In Charge.
62Supply and fixing for 80 mm Air Separator complete all as specifiedand directed by Engr- in-charge
63Supply,installation, Testing and commissioning of water pressure gauge (100 mm Ø) bourdon type with brass ball valve of 3/8\\" Ø and SS tubing, socket. Range (0-50) / (0-100) as required by Engineer In Charge.
64Supply,installation, Testing and commissioning of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count, range 0-50 C. Brass oil filled thermowell of 1/2\\" size as required by Engineer In Charge.
65Supply, installation, commissioning and testing of factory made, CPRI approved LT CHS Plant, indoor type made out of CRCA sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase 4 wire, 415 Volts, 50 Hz, AC supply system, floor mounted and grounting the legs of panel in PCC foundation 1:4:8 complete as all directed suitable for and including the following :-Incoming (a) Bus Bar TPN Copper extensible type main bus bars of minimum of 500 A capacity (As percapacity of corresponding incoming/ Bus couplers) , and auxilliary/bus bars of suitable capacitywith heat shrunk coloured sleeves and i/c SMC bus bars supports at required intervals completefor cross section, size supports & their spacing etc. for withstanding fault level of 50kA .(b) MCCB 320 Amps, 415 Volt, 36 KA, 4 Pole, thermal magnetic release - 01 No for incoming(Extended Rotary Operating Handle, Phase Spreader links and Phase barriers )(c) LED RYB indicator (d) Digtal LED multimeter with suitable size CTs
66Outgoing(a) MCB 20 Amp, 10KA, TPN - 03 Nos Electric Boilers (b) MCB 40 Amp, 10KA, TPN - 03 Nos for Glycole circulating Pumps (c) MCB 10 Amp, 10KA, TPN - 02 No for Pressurization PUMPs /Diesel Pump (d) MCB 10 Amp, 10KA, SPN,- 3 Nos (e) Digital Ammeter with CT 100/5 - 3 Nos for Glycole circulating Pumps(f) All accessories pre wired with appropriate size copper strip or wire and thimbles etc. all as required including foundations asper Manufacturers recommendations all as directed by Engr-in-Charge. Note : Contractor will submit the drawing of panel to GE before execution for approval.
67Supply & Laying/ fixing of following size LT XLPE insulated, screened, PVC sheathed Copper conductor unarmoured cable as required of 1.1 KV grade complete as required.(ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray) :-
684 Core x 10 sq.mm. (Pump)
694 Core x 6 sq.mm (Pressurization Unit & boiler
704 Core x 4.0 sq.mm ( boiler pump)
712 Single core x 2.5 sq.mm. (FCU)
72Supply and fixing rubber matting conforming to IS-15652-2006 complete as required. of size 2m x 1m x25mm.
73M&L for Ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels complete all as directed. NOTE :- (i) The glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. The glycol and water mixture ratio shall be 55:45 and freezing temperature shall be (-) 45 Degree Celcius .
74BULK STORAGE TANK :Supply, installation, testing and connecting with the system and commissioning of horizontal cylindrical oil storage tank made out of mild steel design, temperature (-)30 degree celcius and design pressure atmospheric + static head of liquid, tank shall be complete with manhole, lifting lugs, earthing lugs, vent pipes, dip stick, inlet, outlet connections complete all as specified and directed. Storage capacity (Normal 10 KL, gross capacity not exceeding 10000 L) shell thickness-4mm, end plate thickness 6mm.
75Supply, installation, testing and commissioning LT panel of suitable size as per IE rule and latest IS, factory made dust and vermin proof outdoor type made out of 3.15 mm thick CRCA sheet including seperate compartment for each MCCB & for cable and busbar, mounted on frame of MS angle iron 1.5x1.5x0.6 Mtr Thick with front and back openable door with lock & Key including necessary grouting and double coat powder coated of grey colour painting complete with following accessories.The degree of protection of panel shall be IP-54 including foundation all as specified and directed.:- (CHS PLANT)
76MS Sheet body of LT Panel With double door angle iron frame Aluminium bus bar chamber (4 Strips) 3 phase 415 volts 200 Amps all as required incomming(a) Supply and fix 4 Pole MCCB 160 Amp, 50 Hz, 415 V with rupturing capacity 36 KA. - 01 Nos Outgoing (b) Supply and fix 4 Pole MCCB 100, 50 Hz, 415 V with rupturing capacity 18 KA. -02 Nos(01 Spare)(c) Supply and fix SPN 32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA -03 Nos(d) Indication lamps for R, Y, B - 1 Nos(e) Digital voltmeter 0-500 volts with selector switch - 01 Set(f) Digital ammeter with CT's of suitable as per incoming breaker.(g) Panel Wiring with suitable size PVC insulated PVC sheathed 1100 volts grade with copper conductor multi-stranded cable with lugs on both ends of cable.(h) Front operated ON LOAD change over switch 415V, 4 pole of capacity 125 Amps. - 01 No (j) Lock pedestal - 01 No
77Supply, installation, testing and commissioning LT panel of suitable size as per IE rule and latest IS, factory made dust and vermin proof outdoor type made out of 3.15 mm thick CRCA sheet including seperate compartment for each MCCB & for cable and busbar, mounted on frame of MS angle iron 1.5x1.5x0.6 Mtr with front and back openable door with lock & Key including necessary grouting and double coat powder coated of grey colour painting complete with following accessories.The degree of protection of panel shall be IP-54 including foundation all as specified and directed.:- (OR LINE)
78MS Sheet body of LT Panel With double door angle iron frame Aluminium bus bar chamber (4 Strips) 3 phase 415 volts 200 Amps all as required Incomming(a) Supply and fix 4 Pole MCCB 100, 50 Hz, 415 V with rupturing capacity 25 KA. - 01 Nos Outgoing (b) Supply and fix MCCB 4 Pole 63 Amp, 50 Hz, 415 V with rupturing capacity 16 KA -02 Nos(c) Supply and fix SPN MCB 32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA -02 Nos(D) Indication lamps for R, Y, B - 1 Nos (E) Digital voltmeter 0-500 volts with selector switch - 01 Set(g) Digital ammeter with CT's of suitable as per incoming braker.(h) Panel Wiring with suitable size PVC insulated PVC sheathed 1100 volts grade with copper conductor multi-stranded cable with lugs on both ends of cable.(j) Front operated ON LOAD change over switch 415V, 4 pole of capacity 100 Amps. - 01 No (k) Lock pedestal - 01 No
79S&F MS clamps of suitable length of 40x 5mm MS Flat iron with nuts, bolts and washers for street lights complete all as speified and directed.
80S&F in repairs FRLS PVC insulated standed copper conductor wire of 1.5 sqmm dia, 3 core from existing junction box to light fitting complete all as specified and as directed.
81S&F weather proof Pole junction box made of thermoplastic polycarbonate with gasket comply with IP-65, dust and jet water proof of size 350x250x150 mm suitable size for cable size upto 10 to 25 sqmm alongwith cable inlet with for terminal controlled,1.6mm thick with locking arrangement and rubber gasket including suitable aluminum bus bar of size 25 x 3mm for four pole fixed on porcelain insulator and MCB TPN 32 Amp \\"C' curve -01 no complete with necessary items including a pair of MS flat iron clamp of size 40mmx5mm with 10 mm nuts bolts of suitable length with washer ,suitable to fix in steel tubular pole/PCC pole after taking down old one complete all as directed. Make -sintex/hens
82Material and labour for street light steel tublar pole painting by applying two coats of aluminium paint including bracket and alternative black and Yellow strips on pole with synthetic enamel paint upto 1.5 mtr height from top of PCC foundation (each strip 15 cm height) including applying two coats of cement base paint to coping and Numbering complete all as specified and directed.
83Supply and fix PPR Reducer 50/40 mm Bore
84Supply and fix PPR Reducer 40/25 mm Bore
85M&L for Elestometric Nytral rubber insulation to PP-R pipes suitable for 40/32 mm outer dia 28/19mm thick with chiken wire mesh wire netting 25mm gauge, 20mm mesh with 0.01mm aluminium foil including jointing and fixing material such as solvent adhesive SR-998 complete all as specified and directed by Engr-in-Charge.
86M&L for Elestometric Nytral rubber insulation to PP-R pipes suitable for 25mm outer dia 28/19mm thick with chiken wire mesh wire netting 25mm gauge, 20mm mesh with 0.01mm aluminium foil including jointing and fixing material such as solvent adhesive SR-998 complete all as specified and directed by Engr-in-Charge.
87M&L for Elastometric Nutral rubber insulation to PP-R pipes suitable for 20mm outer dia 22/19mm thick with chiken wire mesh wire netting 25mm gauge, 20mm mesh with 0.01mm aluminium foil including jointing and fixing material such as solvent adhesive SR-998 complete all as specified and directed by Engr-in-Charge.\\"
88Supply and laying 14 AWG Tracer Wire 600 V 100% Solid Copper Conductor Direct Burial Underground, Blue Tracer wire for Locating Under Ground Pipes Complete all as specified and directed by Engineer-in-Charge.
89Supply and fix Connection panel cum temperature controller to regulate electric supply to the Heat Tracer Cable 65W to maintain temp to the water supply pipeline laid underground and to the exposed pipeline and connecting to the LT Supply complete.
90Supply and Fixing for Heavy Duty S S Body Copper Wound openwell submerssible pumping set 0.5 HP 240 V, 50 Hz having water discharge 121 LPM at 12 mtr Head with ON/OFF controller complete all as specified and directed.
91Supply, install, testing and commissioning of Eco friendly Generating Set Diesel Engine driven of capacity 100 KVA/80 W at 0.8 PF or nearest higher size 415 volts AC, 3 phase, 50 Hz 4 wire, directly coupled alternator and engine, water cooled, common base platform with inbuilt fuel tank and including all excavation, PCC foundation, anti vibration pads/dampers as per manufacturer instructions and as directed by manufacturer, DG set to work at ambient conditions and produce specified out put, the derating factors, if any, to be taken into consideration while arriving the capacity to give specified out put, DG set to be factory assembled by the OEM of the engine manufacturer and all components to be accommodated in enclosure and other accessories comprising of the following:-(A) Engine : Eco-friendly emmission limits for diesel engine as per CPCB IV + documents vide latest notificaton GSR 105(E) dated 17 Feb 2015 at Ser No 95 issued by Ministry and Forest, Govt of India and noise level (CPCB norm compliances) diesel engine confirming to BS/IS standard,confirming to BS:5514/DN-6271 / IS 10002/ISO-3046, BHP as per the standard design of OEM to run the DG set in full load / 110% overload with out any change of out put parameters, (not less than 90 BHP),1500 RPM, water cooled complete under NTP condition, with a provision for 10% over load for one hour on 12 hours continious running with CHS (01x DG for working and 01x DG is for stand by) DG set should be capable for 100 KVA output at Partapur area.which is about 13000 Ft for Above MSL
92(i) Radiator/Heat exhanger cooling system(ii) Corrosion inhibitor coolent(iii) Engine mounted water pump(iv) Thermostats(v) Fly wheel with housing complete(vi) Fuel pump system with heavy duty injectors and self contained piping(vii) Spin on type fuel filters(viii) Lub oil pump with self contained piping(ix) Heavy duty Turbo Charger(x) Air intake manifold with necessary connections(xi) Dry type replaceable paper element air filter(xii) Exhaust manifold with flexible piping system and exhaust chimney extended up to a height as per statutory requirement of local pollution control board. The nearest building is 16 RM with G+1 configuration.(xiii) Hospital grade silencer(xiv) Self starter, 24 V, DC(xv) Lead acid DC battery 24 volts,180 AH - 02 Nos (xvi) Electronic / Digital / Manual governor as per manufacturer design and specification.
93Alternator : Synchronious alternator 100 KVA, 1500 RPM, 415 Volts, 50 Hz, 3 phase system self excited, self regulated, self ventilated in brushless design provided with suitable automatic voltage regulator with ± 1% all load between no load to full load and power factor 0.8 to unity with 10% overload capacity for one hour in any 12 hours of operation without exceeding temp rise limit, confirming to BS:5000/IS 4722, IS 13364 and IEC 60034-1 with standard design with IP 23 protection and class \\"H\\" insulation & having surge seperator for protection of alternator for reverse supply. The alternator shall be capable of carrying an unbalanced load of 25% without injurious heating of any part, provided rated current is not exceeded. The alternator shall withstand a short circuit at its terminals for three seconds with excitation adjusted to develop rated voltage at noload without any damage.
94Base Frame : Base rail made out of suitable MS channel mounted on AVM pads as recommended by the manufacturer with integral fuel tank of suitable capacity with drain plug, air vent, inlet and outlet connection, level indicator and with provision of cleaning.
95Acoustic enclosure : Acoustic enclosure drip proof & screen protected meeting stringent MOEF/CPCB norms of 75 dBA @ 1 mtr at 75% load under free field conditions with air inlet louvers powder coated. Use of stainless steel hardware and insulating materials shall meet exacting IS : 8183 insulating materials. Acoustic enclosure shall be as per manufacturer\\"s design. Two point lifting shall be provided for easy handling.
96Provision of DG set foundation : As recommended by the manufacturer in PCC 1:2:4 up to 30cm above ground level.(F) Generator controller: Microprocessor based generator controller with 4 line LCD display with settable prameters for display, audio visual warning and shut down for the following parameters:-
97Display parameters - Battery voltage,Coolent Temperature,Lubricating Oil Pressure, Engine Speed, Engine Hours,Fuel level indication in %,Generator voltage, current, PF, KWH & KW (ii) Audio visual warning for following - Low oil pressure, High coolant temperature, low battery voltage, low fuel level.(iii) shut down/trip with audio/ visual anunciation for the following parameters - High water Temperature (HWT), Low lube oil pressure (LLOP),Over/under speed,high canopy temperature, under/ over voltage, under/over frequency, low fuel level.
98Supply, install, testing and commissioning of Eco friendly Generating Set Diesel Engine driven of capacity 40 KVA/32 KW at 0.8 PF or nearest higher size 415 volts AC, 3 phase, 50 Hz 4 wire, directly coupled alternator and engine, water cooled, common base platform with inbuilt fuel tank and including all excavation, PCC foundation, anti vibration pads/dampers as per manufacturer instructions and as directed by manufacturer, DG set to work at ambient conditions and produce specified out put, the derating factors, if any, to be taken into consideration while arriving the capacity to give specified out put, DG set to be factory assembled by the OEM of the engine manufacturer and all components to be accommodated in enclosure and other accessories comprising of the following:-(A) Engine : Eco-friendly emmission limits for diesel engine as per CPCB IV+ documents vide latest notificaton GSR 105(E) dated 17 Feb 2015 at Ser No 95 issued by Ministry and Forest, Govt of India and noise level (CPCB norm compliances) diesel engine confirming to BS/IS standard,confirming to BS:5514/DN-6271 / IS 10002/ISO-3046, BHP as per the standard design of OEM to run the DG set in full load / 110% overload with out any change of out put parameters, (not less than 90 BHP),1500 RPM, water cooled complete under NTP condition, with a provision for 10% over load for one hour on 12 hours continious running with for OR line :-( 01 X DG for working & 01 x DG is standby) DG set should be capable for 40 KVA output at Partapur area.which is about 13000 Ft for Above MSL
99(i) Radiator/Heat exhanger cooling system(ii) Corrosion inhibitor coolent(iii) Engine mounted water pump(iv) Thermostats(v) Fly wheel with housing complete(vi) Fuel pump system with heavy duty injectors and self contained piping(vii) Spin on type fuel filters(viii) Lub oil pump with self contained piping(ix) Heavy duty Turbo Charger(x) Air intake manifold with necessary connections(xi) Dry type replaceable paper element air filter(xii) Exhaust manifold with flexible piping system and exhaust chimney extended up to a height as per statutory requirement of local pollution control board. The nearest building is 16 RM with G+1 configuration.(xiii) Hospital grade silencer(xiv) Self starter, 12 V, DC(xv) Lead acid DC battery 12 volts,180 AH - 01 Nos (xvi) Electronic / Digital / Manual governor as per manufacturer design and specification.
100Alternator : Synchronious alternator 40 KVA, 1500 RPM, 415 Volts, 50 Hz, 3 phase system self excited, self regulated, self ventilated in brushless design provided with suitable automatic voltage regulator with ± 1% all load between no load to full load and power factor 0.8 to unity with 10% overload capacity for one hour in any 12 hours of operation without exceeding temp rise limit, confirming to BS:5000/IS 4722, IS 13364 and IEC 60034-1 with standard design with IP 23 protection and class \\"H\\" insulation & having surge seperator for protection of alternator for reverse supply. The alternator shall be capable of carrying an unbalanced load of 25% without injurious heating of any part, provided rated current is not exceeded. The alternator shall withstand a short circuit at its terminals for three seconds with excitation adjusted to develop rated voltage at noload without any damage.
101Base Frame : Base rail made out of suitable MS channel mounted on AVM pads as recommended by the manufacturer with integral fuel tank of suitable capacity with drain plug, air vent, inlet and outlet connection, level indicator and with provision of cleaning.
102Acoustic enclosure : Acoustic enclosure drip proof & screen protected meeting stringent MOEF/CPCB norms of 75 dBA @ 1 mtr at 75% load under free field conditions with air inlet louvers powder coated. Use of stainless steel hardware and insulating materials shall meet exacting IS : 8183 insulating materials. Acoustic enclosure shall be as per manufacturer\\"s design. Two point lifting shall be provided for easy handling.
103Provision of DG set foundation : As recommended by the manufacturer in PCC 1:2:4 up to 30cm above ground level.(F) Generator controller: Microprocessor based generator controller with 4 line LCD display with settable prameters for display, audio visual warning and shut down for the following parameters:-
104Display parameters - Battery voltage,Coolent Temperature,Lubricating Oil Pressure, Engine Speed, Engine Hours,Fuel level indication in %,Generator voltage, current, PF, KWH & KW.(ii) Audio visual warning for following - Low oil pressure, High coolant temperature, low battery voltage, low fuel level(iii) shut down/trip with audio/ visual anunciation for the following parameters - High water Temperature (HWT), Low lube oil pressure (LLOP),Over/under speed,high canopy temperature, under/ over voltage, under/over frequency, low fuel level.
105S&F of water heating system/Hamam of capacity 500 Ltrs with Diesel/kerosene burner of 5 inch with boiler and Diesel/kerosene tank Inner sheet made of 10 SWG mild Insulated S S Tank and outer sheet shall be made of 16 SWG of Insulated S S Tank. Glass wool insulation of 25mm thickness to be provided between outer and inner sheet. 100mm dia MS pipes is to be be fitted in centre which will act as heater. One direct water connection for inlet of water. Funnel for pouring water manually to be provided. One over flow pipe, 3 outlet of hot water from the boiler to be provided. Inner chamber is to be painted with boiler paint and external steel surface are to be painted with two coats of synthetic enamel paint over a coat of red oxide incl necessary components like stand for hamam, stand for fuel tank and fuel pipe for connecting burner, diesel/kerosene tank etc include 2x2 Feet M S Iron Stage, complete all as specified and directed by Engineer-in-Charge.
106Supply and fix PPR Ball Valves Plain of 32 mm bore.(Make SFMC-Product ID-293200-(IS:15801)
107Supply and fix PPR Ball Valves Plain of 25 mm bore.(Make SFMC-Product ID-292600-(IS:15801)
108Supply and fix PPR Elbow 90 degree of 32 mm bore.(Make SFMC-Product ID-133200-(IS:15801)
109Supply and fix PPR Reducer of 32 to 25 mm bore.(Make SFMC-Product ID-203212 (IS:15801)
110Supply and fix Brass Insert Female Thread Reducer 32 mm to 20mm bore
111Supply and fix Tank Connector suitable for 32 mm bore.(Make SFMC-Product ID-42114-(IS:15801)
112M&L for connection of PP-R distribution branch with PP-R main Suitable for outer dia 32 mm Equal Tee Pipes of following sizes by providing and fixing tee including cutting and making fusion joint etc.complete all as specified and directed by Engr-in-Charge.
113Supply, install, test and comissioning of reverse osmosis plant of 60 LPH capacity with raw water pump, 100 micron TSS filter obsorbtion filter, reverse osmosis system, 01 micron filter, 0.5 micron filter, ultra violet water disinfections system, stainless steel piping low pressure cut off switch, membrane high pressure skid mounted RO PH correction system, anti scaling dosing system, flow meter high pressure pump along with wet panel and system electrical control panel and copper cable of suitable size from control panel to pump sets Include All PPR Pipe fittings with Puff/Nytral Rubber Insulation with 0.5 mm thick Sheet aluminium cladding for Inlet and outlet storage connection complete all as specified and as directed.
114Supply and fixing Puff water tank 500 Ltrs Capacity, Insulated cylindrical vertical type double layer duly filled with glass wool with closed top hoisted and to resist in Temperature -30 degree to +35 degree celcius fixed in position with all fittings complete all as specified and Directed.
115S & F in of wall mounted LED Tube light fitting 1 x 20W LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting complete all as specified and directed.
116S & F in of wall mounted LED Tube light fitting 1 x 10W LED (6500K), 2 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting complete all as specified and directed.
117Supply & fixing LED street Light fitting 20 Watt made of pressure die cast housing, with toughened glass and high power LEDs with with IP66 protection complete with 40 mm GI pipe bracket not less than 1.2 mtr length and bent to a shape incl 02 Nos 25x6 mm flat clamps with nut bolt and washers complete with all fixing acessories as reqd at site for fixation on wall and connection with 3 core flexible copper suitable size wire as specified and directed
118S&F of 3 in 1 CP wall mixture for mixing hot and cold water with overhead shower arrangement screwed down for iron pipe and and fixed to 15mm bore pipe complete all as specified and as directed
119S&F of health faucet (ABS body) mild steel chromium plated suitable for 15mm dia pipe and 12.5 m long flexible tube and ABS wall hook incl making connections and fixed in pisition complete all as specified and as directed Please Enable Macros to View BoQ information

Other Detail

Information Source https://defproc.gov.in/nicgep/app
Download FileName File Description File Size
Download TD1.rar Tender Documents 0 KB
Download TD2.rar Tender Documents 0 KB
Download TenderFinal.pdf Tender Documents 0 KB
Download Tendernotice_1 (2).pdf Tender Documents 0 KB
Download BOQ_858273.xls Tender Documents 0 KB
Download d351e3f2-b5a1-47e6-984e-591acc7b9751.html Tender Documents 0 KB
Download ORsLINEKHALSAR1.rar Tender Documents 0 KB
Download ORsLINEKHALSAR2.rar Tender Documents 0 KB
Download ORsLINEKHALSAR3.rar Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.