Indian Tenders

TDR 55565408
Tendering Authority Military Engineer Services
Tender No 8056/E8 AGE I Udaipur
Tender ID 2026_MES_766335_1
Tender Brief Corrigendum : Tender For Comprehensive Repair And Maintenance Of Main Water Supply Distribution System At Mount Abu Under Age (I) Udaipur.
City Sirohi
State Rajasthan
Document Fees INR 500.0 /-
EMD INR 19000.0 /-
Tender Value 9.50 Lakh
Tender Type Tender
Bidding Type Open Tender
Tender Category Works
Competition Type Indian
Exemption No
Tender Details

Tender for Comprehensive Repair And Maintenance Of Main Water Supply Distribution System At Mount Abu Under Age (I) Udaipur.

Corrigendum Details
Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate Documents
1 15-06-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-06-2026
2 08-06-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-06-2026
3 15-06-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-06-2026
Key Dates
Publish Date 15-06-2026
Last Date of Bid Submission 20-06-2026
Tender Opening Date 27-06-2026
Contact Information
Company Name Military Engineer Services
Contact Person AGE I UDAIPUR
Address ASST. GARRISON ENGINEER (I) EKLINGGARH CANTT, UDAIPUR (RAJ.) - 313001
Pincode 307501
Other Detail
BOQ Items
Name of Work:- Comprehensive repair and maint of main water supply distribution system at Mount Abu under AGE (I) Udaipur.
Sl. No. Item Description
1Material & Labour for carring to work shop U/S submersible & monoblock motor (water cooled or oil cooled) & pump including cutting U/S winding , removing insulating material, cleaning and rewinding with PVC insulated 1100 volts grade single core copper conductor as per IS 694 winding wire of appropriate size/gauge as per existing , providing insulting mterial of superior quality , supply & replace thrust bearing , assembling the motor complete , including coupling with multistage pump , jointing & connecting with submersible cable and testing at site for following HP of any make :
22.00 HP to 5 HP
37.5 HP to 10 HP
412.50/15.00 HP
5Taking out of submersible pump set from borewell/ Openwell/ sump and servicing of pump set upto 15 HP by replacing of wear & tear parts/rewinding and relowering , including necessary electric and water connections, testing all as specified and directed
6Taking down and dismantling of mono block centrifugal pump set of capacity 7.5 HP to 10.0 HP including impeller and over hauling, supply and fixing of bearing, impeller as per specification, gland bush, stuffing box, gland nuts, gland rope, terminal plate , oiling/greasing and change of gasket/ joints, two coats of synthetic enamal paint, refixing terminal connections , lugs and testing complete on full load after refixing of pipe lines complete all as specified and directed.
7Cleaning of UG (under ground) sumps incl scraping of walls, bottom and mouth of circulating pipe (incoming, outgoing, interconnecting and overflow pipes) and removing the accumulated dirt in form of mud & deposited salts on bottom & walls sump by manullay/mechanically & cleaning the sump by fresh water and finally giving single coat of cement wash on inner surface of the walls & bottom of the sump and painting /writing of date of cleaning all as directed by Engr-in-Charge for the following capacities of sumps :-
8UG sump 15000 Gallons capacity at Main Pump House
9UG sump 50000 Gallons capacity at Main Pump House
10UG sump 5000 Gallons capacity at Booster pump No -3
11UG sump 3000 Gallons capacity at Booster pump No -3
12UG sump 20000 Gallons capacity Near SL-89
13UG sump 40000 Gallons capacity at Booster pump No- 6
14UG sump 7000 Gallons capacity at JCO's pump house
15UG sump 3000 Gallons capacity at Mount pleasant pump house
16UG sump 2000 Gallons capacity at Mount pleasant pump house
17Supply, laying and connecting submersible cable water proof flat 3 core copper conductor PVC insulated & PVC sheathed 1100 Volts grade 6 Sqmm as per IS-694 for subemrsible pumps.
18Repair of pump motor starter of any type & capacity by decarbonizes of contact point, tightening of electric cables and replacement of unserviceable part and complete testing after repair as directed.
19Taking down unserviceable water pressure gauge with rusted and incrustation GI Nipple and supply and fix water pressure gauge dialed type, having scale 0-10 Kg/cm with 15mm x 30 cm long GI Nipple complete fixed to delivery pipe all as specifed and directed.
20Taking up or down foot valve, removing from site and Suppy, fixing and installed foot valve 80mm (3\\") dia foot valve confirming to IS 4038 with brass spindle and using plate flanged and drilled incl necessary nut bolts and washers complete.
21Supply only O-TOLIDINE reagent solution in 500 ml bottle
22Supply only sodium hypochlorite solution 90 to 120 GPL in PVC container of 40 ltrs capacity.
23Repairs of water supply installation electric panels by checking electric connections & replace unsv lugs with new lugs, copper wire etc and testing & replacement of following items:-
243 Phase selector switch
253 phase indicator lamp (RYB)
26Replace existing Volt Meter with digital voltmeter for 3
27Replace existing 3phase Amp meter with digital Amp meter
28Material & Labour for taking out unservisable submersible pumpset(alogwith submersible motor)of any capacity & make,including delivery pipe 40/50 mm bore,flanged/Socket GI tubing (Average 3/6 meter long each pipe), from borewell depth Upto 150 meters, and including lowering the same after repairs of pumpset all as directed by Engr-in-Charge. Note:- (i) Rates are deemed for making flanged/MS Socket joints with rubber washers and replacement of rusted nuts,bolts in work etc all as directed by Engineer-in-charge.
29Material and Labour for Testing of water from approved Govt lab samples collected from pump house No No-01 at main Gate and Pump House No-05 and Pump House Near SL-89 as per norms of WHO and submission of test reports to the entire satisfaction of Engineer-in-Charge Each Month throughout the Contract Period.
30Supply and fixing MUg-10 DOL starter with MS sheet( 2 mm Thick) enclosure suitable for - 15 HP Monoblock Pump motor in existing location including making connection with PVC insulated 1100 volts grade ,three core , multistranded copper conductor of size 6.0 sq mm with voltmeter,ampere meter, Auto Switch,Single Phase Preventor & Indicating Lamp Led Type for Phase Indication (Red Yellow & Blue) ,all as directed and specified. Make : L&T/Havells/Siemens
31Supply and fix ON LOAD change overswitch 415V in sheet metal enclosures 4 pole of capacity 160 Amps complete all as specified and directed by Engr-in-Charge.
32Excavation in trenches n exc 1.5m wide and n exc 1.5 m depth and getting out in any type of soil complete all as specified
33Returning filling in incl spreading, leveling in layers n.exc 25 cm in any type of soil complete all as directed
34Removing excavated soil n.exc 50 mtr and depositing where directed at a level n exc 1.5 m from starting point complete all as directed
35Taking down galvanised water tubing and fittings, including cleaning and refixing or removing to store for credit of 80mm bore
36Re-fixing old GI tubing after threading, cleaning and fix with new fittings to walls and ceiling or laid in floor and trenches complete size 80mm bore pipe.
37Taking down existing rusted GI tubing and supply & fixing only medium grade including cutting bending and necessary fittings like union, elbow, bend, Tee etc as required at site fix on wall or ceiling or laid under floor or in trench complete all as directed of 80mm bore pipe.
38Disconnecting and taking out old unsv gate valve and S& F Gun Metal globe/ gate valve with iron wheel head screwed both ends of 50mm bore.
39Disconnecting and taking out old unsv gate valve and S& F Gun Metal globe/ gate valve with iron wheel head screwed both ends of 80mm bore.
40Taking down or up and Repairing to existing pipe line where leakage occurred incl threading all necessary required fittings and earth work of 80mm bore pipe.
41Taking down and removing u/s old unsv CI body sluice valve and supply, install, testing and commissioning of cast iron sluice valve 80mm dia, class pin 1.60 ISI marked with both ends flanged with cast irin body and wheel and brass spindle non rising type including necessary jointing material with nuts, bolts, washers and rubber sheet 4mm thick with 2 Nos of 80mm GI flanged for GI pipe complete all as directed.
42Material and Labour for preperation of old iron surfaces of any description and applying two coat of synthetic enamel paints over a coat of zinc chrome priming paints as per existing colour or directed by Engr-in-charge.
43Repairing of existing valve pit chamber of any size by re-plastering, finishing & whitewash/painting of chamber cover and cleaning of surrounding area including removal of unserviceable material from site all as directed.
44Material and Labour for cutting existing road/hard standing 40 cm wide including necessary excavation and earth work for taking out/laying pipe and making good disturbed surfaces to match with existing complete all as specified and as directed.
45Taking up or down CI non return valve removing from site and supply and fixing of new 80mm CI non return valve brass spindle with both ends flanged and drilled incl necessary nut bolts nad washers and rubber gasket sheet 4mm thick with 02 Nos of 80mm GI flanged for GI pipe complete all as directed.
46Repair & Servicing of DG set 15 KVA installed at Booster No 3 pump house to carried out following works :-Replacement of Oil Filter, Diesel filter, Engine oil, and Supply & fixing of Battery charger and testing after repair all as specified and directed by Engr-in-charge.
47Supply,fixing and installation of Battery 12.8V 90 Ah for DG Set complete all as specified and directed by Engr- in- charge. Make : Exide/Amaron/Okaya
48M & L for two coat of synthetic enamel paint on distribution pipe line all as per specified and directed by Engr-in-charge. Material and Labour for Testing of water from approved Govt lab samples collected from pump house No-01 at main Gate as per norms of WHO and submission of test reports to the entire satisfaction of Engineer-in-Charge, the test report includes following parameters:- PH value, TDS(mg/l), Hardness (as CaCO3) (mg/l), Fluoride (mg/l), Chloride (mg/l),Turbidity (NTU), E.Coli (cfu), Free residual Chlorine Please Enable Macros to View BoQ information
View Original Notice/Document
Download FileName File Description
Download 001MountAbuByeLaws.pdf Tender Documents
Download 002MountAbuByeLaws.pdf Tender Documents
Download 8056splcondition.pdf Tender Documents
Download 8056tender.pdf Tender Documents
Download 8ee629a0-119d-4b2f-9398-6e143b96e139.html Tender Documents
Download BOQ_858254.xls Tender Documents
Download Tendernotice_1 (2).pdf Tender Documents
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Click tab to load Similar Tender Results...