| 1 | Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 2 core in trenches, through pipe, under culvert or in air including taking out and removing old unserviceable cable complete all as specified and directed. |
| 2 | Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 2 core in trenches, through pipe, under culvert or in air including taking out and removing old unserviceable cable complete all as specified and directed. |
| 3 | Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 3.5 core in trenches, through pipe, under culvert or in air including taking out and removing old unserviceable cable complete all as specified and directed. |
| 4 | All as per srl item No. 03 above but 95 Sqmm 3.5 core |
| 5 | All as per srl item No. 03 above but 50 Sqmm 3.5 core |
| 6 | All as per srl item No. 03 above but 35 Sqmm 3.5 core |
| 7 | M&L for replacement of Earthing complete with GI earth plate 60cmx60cmx6mm thick, buried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level, connected to 25X4mm GI strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 5 and including earth work, PCC pit and RCC cover, watering pipe 20 mm dia light grade, funnel, wire mesh, protection pipe 15 mm dia light grade up to 7.5 mtr length of earth wire, charcoal dust and salt etc and connected to earthing test point all as specified or directed and testing complete all as specified. (Earthing for poles for earth continuity wire) |
| 8 | M&L for replacement of existing worn out /over heated/ multi-jointed ACSR jumpers of LT over head lines with LT- PVC insulated 1100 volts cable of size 50 sqmm complete all as specified and directed. Note:- Length of one jumper shall be 1.5 mtr approx. |
| 9 | Supply and replacement of MCCB, 3 Pole, 415 Volts grade, fixed type of capacity 125 Amp with breaking capacity 16KA, complete all as specified. |
| 10 | Supply and replacement of MCCB, 3 Pole, 415 Volts grade, adjustable type of capacity 160 Amp with breaking capacity 36KA, complete all as specified. |
| 11 | Supply and replacement of MCCB, 3 Pole, 415 Volts grade, adjustable type of capacity 200 Amp with breaking capacity 36KA, complete all as specified. |
| 12 | Supply, fixing & laying in repair GI pipe light grade 50mm bore in trenches, under floor, wall and on pole for cable protection. |
| 13 | Excavation in trenches in soft / loose soil not exc 1.5 mtr wide and not exc 1.5mtr deep and getting out, complete all as specified. |
| 14 | Returning filling in including spreading, leveling, watering and well ramming to a layer not exceeding 25cm complete all as directed. |
| 15 | Removal of excavated material n.exc 50mtr and depositing where directed at a level not exc 1.5 mtr above the starting point. |
| 16 | M&L for Sand cushioning to under ground cable using fine sand (8 cm before & 15 cm after laying of cable) complete all as specified.Note:- Punned thickness of sand shall be measured. |
| 17 | Material and labour for sub class B brick old size covering laid dry, flat transversely along the length of cable on sand cushioning with width equal to the length of the brick complete. |
| 18 | S & F in replacement ON Load changeover switch, 4 pole, I-O-II OPEN EXECUTION Euroload changeover switch of 100 Amp capacity, complete all as specified. |
| 19 | S & F in replacement ON Load changeover switch, 4 pole, I-O-II OPEN EXECUTION Euroload changeover switch of 325 Amp capacity, complete all as specified. |
| 20 | S&F in replacement of copper bus bar of capacity upto 400A including cutting, bending, drilling and connecting in existing bus bar/MCCB as directed. |
| 21 | S&F in replacement of LT panel front/ back doors by fabrication using CRCA sheet as per existing specifications, painting work, hinges, welding work etc., complete including removing the existing doors. |
| 22 | M&L for painting of LT panel of any description with one coat of synthetic enamel paint of standard colour code over the existing painted surfaces after preparing the old painted surfaces by using spray gun complete all as specified and directed. |
| 23 | S&F in replacement of Aluminium bus bar of capacity 200A including cutting, bending, drilling and connecting in existing bus bar/MCCB as directed. |
| 24 | S&F in replacement cable glands for cable of size 50-120Sqmm compete all as specified and directed. |
| 25 | Note :- An amount of Rs. Rs 30,620.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |