| 1 | Excavation in trenches n. exc 1.5 m wide for foundations, laying cables / pipes etc. not exceeding 1.5 m deep and getting out in soft/ loose soil complete, all as specified |
| 2 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in SOFT/LOOSE soil complete, all as specified. |
| 3 | Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete, all as specified. |
| 4 | Removing excavated spoil to a distance exceeding 250m not exceeding 500 metre and depositing where directed complete, all as specified. |
| 5 | Clean dry sand ( seived sand) in range mixing with saw dust in (1:1) ratio including watering and consolidation complete all as specified. |
| 6 | Seived sand at ange mixing with saw dust in (1:1) ratio including watering and consolidation in 50 Kg jute bags and staking of bag as specified by Engg-In-Charge. |
| 7 | PCC type C-2 (1:3:6), using 40 mm graded stone aggregates as in foundation filling & mass concrete, complete all as specified. |
| 8 | PCC type D-2 (1:4:8), using 40 mm graded stone aggregates as in foundation filling & mass concrete, complete all as specified. |
| 9 | Cement concrete, type B-1 (1:2:4), using 20 mm graded stone aggregates as in lintels over 1.5 metre clear span, cills, steps, seismic and other similar band, plinth courses, lacing courses , copings, kneelers, apex stones, bed plates, water troughs and the like complete all as specified. |
| 10 | Cement concrete, type B-1 (1:2:4), using 20 mm graded stone aggregates as in wall or toe wall, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and post complete all as specified. |
| 11 | Precast reinforced cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in manhole covers and the like duly placed on manholes with cement mortar (1:4) complete. |
| 12 | Brick work with sub class 'B' brick,, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified. |
| 13 | Use & waste of formwork to faces of wall, retaing walls, abutmentss, parapets, and staircase railing and similar work including attached pillasters, buttres etc vertical or to better for flat fair finished surfaces of concrete, complete all as specified. |
| 14 | Mild steel works in hand rails, half round or other stock section or core for wooden handrail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) in-cluding all necessary drilling, bolting or riveting, etc., confirming to Fe-290-Gde E-165, complete all as specified. |
| 15 | Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 5cm not exceeding 10cm long, dia of neck 11 to 15 mm, complete all as specified. |
| 16 | Mild steel TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified. |
| 17 | Concertina coil with punched tape 600 mm dia CONSEC-ZAL Super Razor punched barb tape (SRBT) BTO-22 Aluminium base helix coil with and including necessary GI fixing clips for securing, IN REPLACEMENT, complete all as specified with following specifications :-(i) Dia of coil (unstretched) - 600 mm(ii) No. of circles - 50 turn per coil(iii) Weight of each coil with hessain pack - 8.50 Kg (Minimum)(iv) Coverage per coil - 6 RM(v) Central core wire - Made from 2.60 mm dia GI - HTSS wire as per IS- 4454 galvanised as per IS -2629 .(vi) Razor punched strip Razer punched tape is CONSECZAL steel comprising of aluminium base with zinc alloy @ 230 gm/Sqm conforming to ASTM A-792/A-792M with CLR anti corrosive paint by Hot Dipping process .NOTE :- Running length of the wall shall be measured for the payment purpose. |
| 18 | Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed, IN REPLACEMENT,, (each line wire to be measured) complete all as specified |
| 19 | Supply only chain link mild steel galvanised hot dipped 3-4mm dia, fencing complete all as specified.NOTE:- The weight of chain link fencing shall be ascertained by BOO as ordered by GE and payment shall be made acoordingly. |
| 20 | Fixing only chain link fencing including line wire mesh, any mesh, size and type to any types of standards rails, straining bolts, etc. including provision of binding wire complete, all as specified. |
| 21 | Mild steel round bars 10mm dia and over, cut to length, bent to shape required, for chain link fencing complete, all as specified. |
| 22 | 25 mm thick, cement concrete type B-0, 1:2:4 using 12.5 mm graded stone aggregate, finished rough, as in sub floors or similar locations, complete all as specified. |
| 23 | 75 mm thick, cement concrete type D-2, 1:4:8 using 40 mm graded stone aggregate as in as sub base in flooring / hardstanding complete all as specified |
| 24 | Factory made PCC chequered tiles, glossy finish, ISI Marked, with grey cement & pigment, 22-25 mm thick, of size 300 mm x 300 mm, in floors, over & including 20 mm thick cement mortar (1:6) screed, set and jointed with grey cement slurry complete, all as specified. |
| 25 | 80 mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of shape approved by GE, made by table vibratory method using PU mould, laid in required pattern over and including 50mm thick compacted bed of coarse sand, compacting through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete. |
| 26 | Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair mixed with or without water proofing coompound on walls in cement mortar (1:4), complete all as specified. NOTE: Supply only WPC will be measured & paid for separately under respective item of BoQ. |
| 27 | Supply only integral water proofing compound ISI Marked. |
| 28 | Two coats of cement base paint on new plastered wall surfaces, including preparation of surfaces, complete all as specified. |
| 29 | Two coats of cement base paint on old plastered wall surfaces, including preparation of surfaces, complete all as specified. |
| 30 | Complete removal of existing treatment of any description, including prepration of wall surfaces of any description and applying Two coats of exterior acrylic emulsion over and including a coat of water based exterior primer complete all as specified |
| 31 | Two coats of synthetic enamel paint over & including a coat of red oxide primer over steel or iron new surfaces of any description not other wise described over 10cm width or girth including preparation of surfaces, complete all as specified. |
| 32 | Two coats of synthetic enamel paint over & including a coat of red oxide primer over steel & iron (new) surfaces of any description, not exceeding 10cm in width or girth when unconnected with other painting or when painted in a different tint complete all as specified. |
| 33 | 100mm dia cast iron spun type soil waste and vent pipe in any length with or without ears with cement joints fixed to floors/ wall, IN REPLACEMENT, complete all as specified. |
| 34 | 75mm dia cast iron spun type soil waste and vent pipe in any length with or without ears with cement joints fixed to floors/ wall, IN REPLACEMENT, complete all as specified. |
| 35 | Cast iron bend, (any radius) diminishing pieces or tapers ( larger bore measured) 100 mm bore, with oval access door, ISI marked , IN REPLACEMENT, complete all as specified. |
| 36 | Cast iron bend, (any radius) diminishing pieces or tapers ( larger bore measured) 75 mm bore, with oval access door, ISI marked , IN REPLACEMENT, complete all as specified. |
| 37 | 110 mm bore uPVC pipes, type-B, ISI marked (IS:13592) single socketed in any length with or without rubber ring joints, fixed under floors / fixed to wall as SWR pipes, complete all as specified |
| 38 | 110 mm bore, uPVC/PVC bends any radius, complete all as specified. suitable for uPVC soil waste discharge pipes, complete all as specified |
| 39 | uPVC/PVC vent cowl 75-110 mm external dia, complete all as specified. |
| 40 | 150mm bore reinforced concrete pipe class NP-2, ISI marked, laid in trenches including jointing & testing complete with collars complete all as specified |
| 41 | Cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in bed to 150mm bore drain pipes of any description including packing under and haunching against the sides of pipe complete all as specified |
| 42 | Removing / cleaning of blockage from traps of WC trap, bath rooms/ kitchen sink/ wash hand basin/ urinal point and gully traps of any description and in any position by removing sand/ sludge/ silt and other foreign material deposited in it (either manually or mechanically) upto first manhole and making the sewage system functional to the entire satisfaction of Engineer-in-Charge, complete. |
| 43 | Removing of blockage / cleaning of sewage lines 100mm / 150 mm bore laid at any depth (either manually or mechanically) by removing all type of sand/ sludge/ silt and any other foreign material deposited in it including manholes and removing the same outside MoD land in closed tanker etc complete. |
| 44 | Taking out thick/solid sludge (sedimented sand sludge/grit ,ash rages , fibres and springe material etc) from septic tanks including inlet and outlet chambers and soakage well including removing the same outside MoD land in closed tanker etc complete. |
| 45 | Cleaning of strom water drain n exc 0.50m deep by desilting, deslugdging including removing the grass in bottom and sides and disposed off the sludge outside the campus, burried into pits and sprinkling of bleaching powder over their to the entire satisfaction of Engineer-in-Charge, complete. |
| 46 | Taking down iron gate shutters of any description over all size n exc 6.0 Sq.m of each shutter and refixing in the same or other gate pillar after relocating the pintel hinges, nuts, bolts etc with necessary cutting / welding of gates to make functional etc complete. |
| 47 | Taking down cement plaster of any description on brick walls, ceiling or concrete surfaces etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified. |
| 48 | Dismantling floor, hearth or wall tiling, stone slab(s) including cement mortar bedding and removing rubbish off the premises complete all as specified. |
| 49 | Demolition brickwork or stone / boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified. |
| 50 | Demilition of stone slabs and tiles laid bedded and pointed in any mortar of any descriptiion or thickness in floor , apron etc complete all as specified. |
| 51 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided all as specified. |
| 52 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided all as specified. |
| 53 | Demolition and breaking up 150mm bore drain pipes (salt glazed stoneware, AC or reinforced concrete) set in cement mortar all as specified |
| 54 | Dismantling fencing wire mesh, any type complete all as specified. |
| 55 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground, embedded with concrete etc. complete all as specified. Please Enable Macros to View BoQ information |