| 1 | Dismanling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 2 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including Naintal or similar pattern roof coverings complete all as specified and directed |
| 3 | S & F steel work in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to I.S.1161- 1979 Fe 410-W (GdeE- 250) complete all as specified and as directed by Engineer-In-charge |
| 4 | S&F Pre-painting galvatume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strenght of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed |
| 5 | S&F Pre-painting galvatume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strenght of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed |
| 6 | M & L for preparation of new or previously untreatedsteel surface any description not otherwise described and exc 10cm width or girth applying two coats of synthetic enamel paint over a coat of red oxide all as specified and directed. |
| 7 | -Ditto- all as per item above but one coat of synthetic enamel paint on old steel surfaces of any description. |
| 8 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness inclduding cover fillets. |
| 9 | S&F Anodised aluminium snap grid framed work for false ceiling and incl hangers 6mm dia G.I (upto 1200mm long) adjusting level fixed to roof slabs/purlin/rafter with the help of cleats made out of G.I flat 40x3mm size 60mm long and expansion holdfastener 12.5mm dia 40mm long complete. |
| 10 | M&L for false ceiling with gypsum board, perforated type, ,factory made matt finish surface/pre painted surface, 600 x 600 mm in size and 12 to 15 mm thick on exisiting aluminium snap grids 605 X 605 mm as in ceiling. |
| 11 | Dismantling timber scantlings 40 sq.cm and over in section, in any positions as in framed work. |
| 12 | -Ditto- all as per item above but in fillets, rails, posts, rafters, purlins, etc under 40 sq.cm in section. |
| 13 | M & L for second class hardwood clean sawn scantlings as in timber framed and fixed complete all as specified and directed. |
| 14 | -Ditto- all as above but except timber. |
| 15 | M & L for second class hardwood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exc 3 & n.exc 6 sq.cm complete all as specified and directed. |
| 16 | M & L for second class hardwood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exc 13 & n.exc 25 sq.cm complete all as specified and directed. |
| 17 | M & L for 6mm thick (No of ply 5) plywood, grade BWR, type BB, fixed with nails to timber frame work as in ceiling complete all as specified and directed. |
| 18 | M & L for 18/19mm thick Particle board one side, medium density flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screw to timber frame work as in ceiling complete all as specified and directed. |
| 19 | M & L for 12mm thick Particle board both side, medium density flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screw to timber frame work as in ceiling complete all as specified and directed. |
| 20 | M & L for preparation of newly plastered or un-plastered surfaces of walls and applying three coats of white wash complete all as specified and directed. |
| 21 | M & L for preparation of wood and wood based materials, new or old surface of any description and girth not otherwise described and treated with two coats of creosote oil complete all as specified and directed. |
| 22 | M & L for preparation of new wooden surface any description not otherwise described and exc 10cm width or girth applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed. |
| 23 | -Ditto- all as per above but one coat of synthetic enamel paint on old wooden surfaces of any description. |
| 24 | Taking down chowkats or frames not exc 1.5 sq.m each but with shutters (without taking off shutters from the frames). |
| 25 | Taking down chowkats or frames exc 1.5 sq.m but n.exc 4 sq.m each but with shutters (without taking off shutters from the frames). |
| 26 | S & F second class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints. |
| 27 | S & F of 35 mm thick (Batten thickness) 2nd class hardwood plain, framed panelled shutters (any numbers of panels) with panels of timber flat on both sides (feather edged) or od veneered particle board of medium density , wood particle board with commercial face veneers and fitted to chaukhats complete all as specified and directed. |
| 28 | S & F of 35 mm thick (Batten thickness) 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. divided into squares, with plain, chamfered or rounded, mitered and rebated sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. and size of the members of shutter is as specified in clause No. 8.24 (a) of MES schedule part – I (Specifications - 2009) complete all as specified and directed. |
| 29 | S & F of 30 mm thick (Batten thickness) 2nd class hardwood plain, framed panelled shutters (any numbers of panels) with panels of timber flat on both sides (feather edged) or od veneered particle board of medium density , wood particle board with commercial face veneers and fitted to chaukhats complete all as specified and directed. |
| 30 | S & F of 30 mm thick (Batten thickness) 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. divided into squares, with plain, chamfered or rounded, mitered and rebated sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. and size of the members of shutter is as specified in clause No. 8.24 (a) of MES schedule part – I (Specifications - 2009) complete all as specified and directed. |
| 31 | M & L sheet glass, 4mm thick ordinary quality and glazing with oil putty or beadings in square not exc 0.5 sqm in each pane. |
| 32 | S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples all as specified and directed. |
| 33 | S & F clamps, hold fast,hook washer & similar small articles conforming to Fe-290 Gde-E-165. |
| 34 | M & L for providing cement concrete type C1 1:3:6 using 20mm graded stone aggregate as in hold fast blocks. |
| 35 | S & F 125mm butt hinges, medium weight, cold rolled mild steel and fixed. |
| 36 | -Ditto- all as per item above but 75mm long. |
| 37 | S & F 300mm length aluminium alloy, anodised, sliding door bolt hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed. |
| 38 | S & F 150mm Aluminium handles, cast type, anodised |
| 39 | S & F 125mm Aluminium handles, cast type, anodised |
| 40 | S & F 150mm aluminium, anodised, barrel tower bolts of extruded section and fixed. |
| 41 | S & F 125mm aluminium, anodised, barrel tower bolts of extruded section and fixed. |
| 42 | S & F in repair hydraulically regulated door closer, (die cast) body designation No 3, universal type suitable for door shutters of 851 to 1000mm in width and weight b/w 61 to 80kg complete. |
| 43 | S & F mild steel 300mm ordinary rat tail rod pattern springs, including roller and roller plate complete. |
| 44 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and directed. |
| 45 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for. |
| 46 | M &L 75mm thick cement concrete type C2 1:3:6 using 40mm graded stone aggregate finishing surface even and smooth wuthout using extra cement a in plinth protection all as specified and directed. |
| 47 | Surface excavation of hard / dense soil n. exc 30 cm deep and averaging 15 cm deep and getting out complete all as specified and directed |
| 48 | M &L 75mm thick cement concrete type D2 1:4:8 in sub base floor complete all as specified and directed. |
| 49 | M & L for PCC 1:2:4, type B-1, using 20mm graded stone aggregate as in copings, bed blocks, etc including necessary form work complete all as specified and directed. |
| 50 | M&L Chequred tiles with grey cement 30cm x 20cmx 25mm thick set, jointed and pointed in neat cement slurry in floors and screed bed 15mm thick layer in cm 1:6 for laying floor finishes complete all as specified and directed |
| 51 | Removing excavated material to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 m above the starting point all as spd and directed |
| 52 | M &L chequered cement concrete tile 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry over 20mm thick scrred bed in cement mortar 1 :4 as in floors with grey cement and pigment complete all as specified and directed. |
| 53 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 54 | M & L for vitrified ceramic tiles light shade 10mm thick but not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortar 1:6 etc set and jointed in neat cement slurry and pointed in coloured cement to match the surface of tile completed all as specified and directed by E-in-Charge. |
| 55 | M & L for vitrified ceramic tiles light shade 10mm thick but not exceeding 0.36 sqm, in dado/ skirting in verticle surfaces etc floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick screed bed in cement mortar 1:4 etc set and jointed in neat cement slurry and pointed in coloured cement to match the surface of tile completed all as specified and directed by E-in-Charge. |
| 56 | M & L for non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed. |
| 57 | M & L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete |
| 58 | M & L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement creed and jointed with ditto as per item complete all as specified and directed by Engr In Charge. |
| 59 | M & L for Granite tiles 20mm thick machine cut bedded and jointed with grey cement slurry and pointed with white cement with admixture and pigment to match the shade of Granite stone incl grinding and polishing complete all as specified. |
| 60 | Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm area on plan and not exceeding 1.5 meter in depth and getting out in soft/disintegrated soil. |
| 61 | M & L for PCC (1:4:8) type D-2 using40mm graded stone aggregate in foundation/filling and mass concrete. |
| 62 | M & L for Reinforced Cement Concrete (nominal mix) B1 1:2:4 (using 20 mm graded aggregate) in foundations including Plinth beam, base for column, rafts, footings and mass concrete complete all as specified and directed. |
| 63 | M&L for RCC (nominal mix) B1 1:2:4 (using 20 mm graded aggregate), as in Columns, pillars, piers, posts and struts & similar RCC works all as specified and directed. |
| 64 | M & L for Reinforced Cement Concrete (nominal mix) B1 1:2:4 (using 20 mm graded aggregate) in Beams, cantilevers, lintels over 1.5 M span complete all as specifed and directed |
| 65 | M & L for Reinforced Cement Concrete (nominal mix) B1 1:2:4 (using 20 mm graded aggregate) in Chajjas and the likecomplete all as specified and directed |
| 66 | M & L for 10mm dia and over TMT bars cut to length bent to shape as required including binding with mild steel annelid wire not less than 0.90mm dia all as specified. |
| 67 | M & L for 5mm dia and over up to 10 mm dia TMT bars cut to length bent to shape as required including binding with mild steel annelid wire not less than 0.90mm dia all as specified. |
| 68 | Use & waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, plinth beams and similar works for rough finished surface complete all as directed. |
| 69 | Use & waste form work to sides of pillars, posts and columns for rough finished surface of concrete complete all as directed. |
| 70 | Use & waste Form work to sides and soffits of floor or roof beams, lintiles cantilever etc for rough finished surface complete all as directed. |
| 71 | Use & waste Form work to edge of concrete , flats, treads, breaks in floors, window cills etc for rough finished surface exc 5 cm but n. exc 10 cm wide complete all as directed. |
| 72 | M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finish the surface even and smooth without using extra cement all as specified and as directed by Engineer-In-Charge. |
| 73 | Supply only integral water proofing compound of approved brand/make. |
| 74 | M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement. |
| 75 | Preparing New plastered surfaces and applying two coats of distemper oil emulsion including preparatory to distempering on surfaces of walls. |
| 76 | Preparing new plastered surfaces and applying Two coats of cement base paint on surfaces of walls over one coat of white wash. |
| 77 | M&L for 75 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing & finished the surface even & fair all as specified. |
| 78 | M & L for 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded granite stone aggregate) in sub base of flooring/ hard standing /footpath complete all as specified and directed by Engr In Charge. |
| 79 | M&L 25 mm thick PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in floor, finished even and smooth without using extra cement. |
| 80 | M&L 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in plinth protections, finished even and smooth w/o using extra cement |
| 81 | S & F of 0.63 mm thick galvanized corrugated iron (CGI) sheeting with two corrugation side lap using grade of zinc coating -275. inclusive of both sides, fixed with ‘L’ or ‘J’ type hooks or cranked hook / bolts and washers as in roof covering etc. complete all as specified and directed. |
| 82 | S & F of 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etccomplete all as specified and directed. |
| 83 | Demolition of brick work or stone / boulder massonary, build in cement mortar incl all quoins , pillers etc. |
| 84 | M & L for Precast cement concrete block massonary 1:3:6 type C1 with solid block exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed by E-in Charge. |
| 85 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc. |
| 86 | M & L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement plaster 1:6 and finished even and smooth (without using extra cement). |
| 87 | M & L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement plaster 1:4and finished even and smooth (without using extra cement). |
| 88 | M & L complete removal of existing treatment and applying 3mm thick Birla wall care putty and applying two coats of distemper oil emulsion over a coat of primer on wall complete all as specified and directed. |
| 89 | M & L for preparation of new plastered surface or previously untreated walls surfaces and applying two coats of cement base paint over coat of primer on wall complete all as specified and directed. |
| 90 | Taking up or down 15mm bore steel water tubing & connections, incl cleaning for existing or offrening credit as per sch of credit all as directed. |
| 91 | S&F 15mm bore galvanised steel tubes, 'medium grade' with all fitting and fixed complete to walls and ceiling or laid in floors completed all as specified and directed by E-in-Charge |
| 92 | S&F in repair bib taps 15mm dia fancy type chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed. complete all as specified and directed by Engr In Charge. |
| 93 | S&F in repair 15mm dia stop valve chromium plated, fancy type screwed down, high pressure with crutch or butterfly handle screwed both end for iron pipe complete all as specified and directed by Engr In Charge. |
| 94 | S&F in repair PVC connections 45cm long and 15mm dia chromium plated brass nuts and PVC washers on both ends, complete all as specified and directed by Engr In Charge. |
| 95 | S&F in repair Vitreous China Urinal flat back size 465x355x265mm white with grating and union for discharge pipe incl fixing plug , bedding, urinal against wall in CM 1:2 securing urinal to plug pointing around back in cement fixing autmetic flushing cistern with bracket flush pipe grating and union for discharge pipe etc complete all as specified and directed by Engr In Charge. |
| 96 | S & F in repairs for Wash Hand basins, Vitreous China, white, flat back, size 550x440mm, including cutting for and pinning in ends of brackets or erecting stand, angle bracket (but exclusive of fixing of supply, waste pipe, taps) complete all as specified and directed. |
| 97 | Supply & fixing in repair 15mm pillar taps fancy type cast copper alloy, with capstan heads, chromium plated, screwed down , high pressure, with or without lettered 'Hot' or Cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed. Bore of pipe in 15mm complete all as specified and directed by Engr In Charge.. |
| 98 | S&Fin repairs PVC Valveless, syphonic action type, flushing cistern of 10ltr capacity, high or low level, white with inlet, ball valve, float and and handle incl brackets, and connections to flush pipes of polythelene of low or high density or PVC 32mm dia for low level cistern complete all as specified and directed by Engr-in-charge. |
| 99 | S&Fin repair Vitreous China wash down water closet pan ( pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) incl Plastic water closet seat, black, closed patern with flat bottom and cover and mild steel chromium plated or alumined hinging device vitrious Chaina pedestal pattern WC incl PVC seat cover and flush pipe etc complete all as specified and directed by engr-in-charge. |
| 100 | S&F in repair 600mm x 450mm bevelled edge mirror of selected quality glass , mounted on 6mm thick AC building board or commerical plywood and fixed to wodden plugs with chromium plated brass screws and cup washers etc complete all as specified and directed by engr-in-charge. |
| 101 | S&F in repair Soap dish, any type, fixed to plug with chromium plated brass screws embedded in the wall all as specified and directed by Engr-in-charge. |
| 102 | S&F in repair 20mm dia brass chromium plated tubular towel rail, D type, 60cm long b/w flanged and directed by Engr-in-charge. |
| 103 | S&F cast iron floor trap 75mm out let dia with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4).. |
| 104 | S&F in Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guards and railing 60cm long complete all as specified and directed by Engr In Charge. |
| 105 | S&F in repair , brass chromium plated , toilet paper holder fixed with chromium plated brass screw, completed all as specified and directed by Engr-in-Charge. |
| 106 | Dismantling water tank of capacity 1000 ltr vertical type and removing to store all as specified and directed. |
| 107 | S&F in PUF tank installed cylinderical of capacity 1000 ltr vertical type double layer duly filled with PUF insulation superior quality to resist in temperature -30 to +35 degree centigrade and hoisted in platform complete with making pipe line connection complete all as specified and directed. |
| 108 | Supply & fixing in repair 15mm CP mixer for mixing hot and cold water screwed down for iron pipe and fixed complete all as specified and directed by Engr In Charge.. |
| 109 | S&F in repair 32mm dia PVC waste pipe for WHB complete all as specified. |
| 110 | S&F in repair C.P grating 100mm square/round with or without hole complete all as specified. |
| 111 | S&F in 20 mm dia ,Al alloy curtain rails with brackets fixed in repair. |
| 112 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc all as specified and directed by Engr-in-Charge |
| 113 | Taking down unserviceable submain wiring and service cable alongwith batten /PVC conduits etc. and making good disturbed surfaces of walls/floors and match the existing surface all as directed at site. |
| 114 | Taking down unserviceable main switches, DBs with MCB SP/Isolators by unscrewing form board complete all as specified and directed by Engineer-in-Charge |
| 115 | Matrial & Labour for point wiring using approved colour coding as per IS with using approved coper coding as per IS 1.5 Sqmm multistranded , 1100 volt grade copper conductor FRLS cable of PVC insulated and unsheathed type alongwith 1.5 Sqmm PVC insulated stranded copper conductor cable for continuous earthing in & incl PVC casing & caping with accessories having ISI mark fixed on wall surfaces / ceiling including provision PCV Box on top for fixing switches sockets etc. all as specified for one light point / fan / Bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge. |
| 116 | All as per Srl item No 115 here-in-before but controlled with one 3 pin socket outlet 5 Amp on the same board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge. |
| 117 | All as per Srl item No 115 here-in-before but controlled with one 3 pin socket outlet 5 Amp on the independent board with cable 1.5sqmm including provision of 1.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge. |
| 118 | All as per Srl item No 115 here-in-before but controlled with one 3 pin socket outlet 15 Amp, independent board with cable 2.5sqmm including provision of 2.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge. |
| 119 | Supply and fixing of switch piano type 5 Amp, 230 Volt, flush button single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 120 | Supply and fixing of socket outlet 3 pin 5 Amp 2-in-one 230 Volt flush type complete all as specified and directed by Engineer -in-Charge. |
| 121 | Supply and fixing of switch piano type 15 Amp, 230 Volt, flush button single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 122 | Supply and fixing of Socket outlet 2 in 1, 3 pin, 5 and 15amp flush type single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 123 | Point wiring complete with 1.5 sqmm single core PVC insulated with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi standed copper conductor drawn through and including non metallic rigid PVC conduit with all conduit accessories (concealed)/ Casing and caping and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor, fabricated steel terminal box made out of 1.6 mm thick MS sheet concealed in walls with 3 mm thick bakelite sheet ISI marked top cover with brass screws and cup washers for housing the switches, socket outlets, fan regulators etc for One light / Exhaust Fan point controlled by one switch, all as specified and as directed. |
| 124 | All as per Srl item No 123 here-in-before but controlled with one 3 pin socket outlet 5 Amp on same board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge. |
| 125 | All as per Srl item No 123 here-in-before but controlled with one 3 pin socket outlet 5 Amp on the independent board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge. |
| 126 | All as per Srl item No 123 here-in-before but controlled with one 3 pin socket outlet 15 Amp, independent board with cable 2.5 sqmm including provision of 1.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge. |
| 127 | Supply and fix Modular switch 1 way 6A, 1 module type, 230 volts, ISI marked complete. |
| 128 | Supply and fix Socket, 6A - 2/3 pin combined 2 module, multipurpose flush type, ISI marked complete all as specified and as directed. |
| 129 | Supply and fix Socket 6A/16A - 2/3 pin combined 2 module, multipurpose flush type, ISI marked complete all as specified and as directed. |
| 130 | Supply and fix Modular switch 1 way 16A, 1 module, multipurpose flush type, ISI marked complete all as specified and as directed. |
| 131 | Supply and fix MODULAR WHITE COVER PLATE WITH FRAME White cover plate with frame, 2 module ISI marked complete all as specified and as directed. |
| 132 | Supply and fix MODULAR WHITE COVER PLATE WITH FRAME White cover plate with frame, 3 module ISI marked complete all as specified and as directed. |
| 133 | Supply and fix MODULAR WHITE COVER PLATE WITH FRAME White cover plate with frame, 4 module ISI marked complete all as specified and as directed. |
| 134 | Supply and fix MODULAR WHITE COVER PLATE WITH FRAME White cover plate with frame, 6 module ISI marked complete all as specified and as directed. |
| 135 | Supply and fix MODULAR METAL FLUSH BOX Metal flush box 1/2 module ISI marked complete all as specified and as directed. |
| 136 | Supply and fix MODULAR METAL FLUSH BOX Metal flush box 3 module ISI marked complete all as specified and as directed. |
| 137 | Supply and fix MODULAR METAL FLUSH BOX Metal flush box 4 module ISI marked complete all as specified and as directed. |
| 138 | Supply and fix MODULAR METAL FLUSH BOX Metal flush box 6 module ISI marked complete all as specified and as directed. |
| 139 | M&L Ceiling rose, 3 terminal with ISI mark all as specified and directed by Engr-In-Charge. |
| 140 | Supply and fixing surface & wall mounted LED 20W tube light fitting 4 feet with high quality material and design, extruded aluminium housing enhances safety. High quality PC diffuser, reliable and robust housing structure, maximize the endurance over the life time slim integrated design, easy to install efficacy 125 limen/ watt all accessories as specified and directed by Engg-in-Charge. Make: Crompton Cat No. CCS-100-20-65-HL2-DP-NWH or equivalent of Wipro/Philips/Havells |
| 141 | Supply and fixing recessed mounting 36 W 3000K (Warm) 2 x 2 panel luminaire with high performance LEDs suitable for mounting with Grid ceiling 2 x 2 incl driver complete fitting , all as specified and directed by Engr-in-Charge. Make: Crompton / Havells / Wipro |
| 142 | Supply & Fixing 9 Watt LED Lamp(White) all as specified and directed by Engr-In-Charge. Make Havells |
| 143 | Supply & Fixing 9 Watt LED Lamp(warm) all as specified and directed by Engr-In-Charge. Make Havells |
| 144 | Supply and fix old unserviceable LED light fitting Integral slim LED batten Integral 10 watts of 2 feet long internally prewired complete with all accessories and including connecting up with three core flexible copper conductor cable with flexible pipe of suitable size from ceiling rose complete all as specified and as directed by Engr in Charge. |
| 145 | Material and labour for lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings. Make : Anchor/leader/havells |
| 146 | Supply and fixing decorative wall mounting champagne gold finish fixture with plastic body suitable for 9 watt lED lamp B22 base complete fitting all as specified and directed by Engr-in-Charge. Make: Crompton / Havells / Wipro Note :- LED Lamp for Light fitting will be paid and measured seperately in respective item. |
| 147 | Supply & Fixing bulk head light with 10 W LED Lamp complete. Make Crompton Cat No LBHP-10-CDL or equivalent in Philips/wipro/Havells |
| 148 | Supply & Fixing LED Bldg security light fitting 30 Watt with best in class design & robust heat sink along with class leading IP65,IK & surge protection for long lasting performance connected with copper copnductor cable size. Note- Sutaible size bore of security light suitable for GI Bracket measured and paid seperately in respective item. |
| 149 | Material and labour streeet blioght bracket made out form GI Pipe 32/40mm bore light grade 1,20 mtr long bent to required shape and fixing to poles etc including fixing of clam,nuts,bolta etc all as specified and directed by Engineer-in-Charge |
| 150 | Supply and fixing of sheet metal enclosure double door for DBs single pole and neutral for 04 way 240 volt complete all as specified and directed by Engineer-in-Charge |
| 151 | Supply and fixing of sheet metal enclosure double door for DBs single pole and neutral for 08 way 240 volt complete all as specified and directed by Engineer-in-Charge |
| 152 | Supply and fixing of sheet metal enclosure double door for DBs single pole and neutral for 12 way 240 volt complete all as specified and directed by Engineer-in-Charge |
| 153 | Supply & fix exhaust fans AC single phase 230/ 240 V of size 450 mm sweep with louver all as specified and directed by Engr-in-Charge |
| 154 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.(i) SP 5 to 32 Amp |
| 155 | (iii) SPN 63 AMP |
| 156 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated 10 sqmm two core aluminium solid conductor , served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular |
| 157 | Supply and fixing House service bracket(hook type complete with 3,0m long GI pipe (40mm dia Med Grade) with two nos of suitable size of clamp,nuts,bolts and washers etc fixed to GI sheet roof complete all as secified and directed |
| 158 | M & L for Earthing complete with galvanised earth plate electrode of size 600x600x6 mm thick burried directly in ground earth pit not less than 2.25 m below ground level connected to 4 mm dia GI earth wire as earth lead by means of bolts,nuts,washers of Gl all as shown in electrical plate No 3 of SSR part I connected to earth test point including earth work excavation in any type of soil PCC (1:3:6) type C1 bed and chamber RCC (1:2:4) type B1 cover 40mm thick including 6 mm dia reinforcement and funnel watering pipe etc all as specified and directed. |
| 159 | Supply and fixing of Socket outlet 2 in 1, 3 pin, 5 and 15amp flush type single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 160 | Supply and fix in replacement LED Batten 20W , 4 ft (Approx) length ultra slim square profile with extruded polycabonate, enviromenental friendly, energy efficient , connected with 23/.0076 twin core PVC flexible cable complete all as specified and directed. Make- Havells / Philips / Crompton |
| 161 | Supply and fixing 9 watts LED backup lamp of 4 hours backup, with auto switch on mechanism in case of power failure, works as regular 9w lamp in normal mode and a 4w lamp in backup mode all as specified and directed by Engg-in-Charge. Make: Havells |
| 162 | Supply & Fixing bulk head light with 10 W LED Lamp complete. Make Bajaj Cat No BIBWP 10W LED or equivalent of Wipro and CG/Philips |
| 163 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated 16 sqmm two core aluminium solid conductor , served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular all as specified and directed. |
| 164 | Supply and fixing House service bracket (hook type complete with 3.0m long G.I. pipe 40mm dia Med. Grade), with two nos of suitable size of clamp,nuts, bolts and wahers etc fixed to GI sheet roof complete all as specified and directed. |
| 165 | Schedule of Credit Please Enable Macros to View BoQ information |