Indian Tenders

Tender Notice

TDR 55466578
Tendering Authority Local Self Government Department
Tender No ET02/DPEKM/AE/LSGD/26-27
Tender ID 2026_LSGD_850603_1
Tender Brief Corrigendum : Tender For Annual Plan-Ekm Dp - Malayattoor Division- Completion Of Kalarikkal Chira Drinking Water Supply Scheme In Manjapra Gp-To Replace Defective Motor Pump Sent And Other Electrical/Piping Accessories.-General Electrical Work
City Ernakulam
State Kerala
Document Fees INR 555 /-
EMD INR 4973.0 /-
Tender Value INR 1.98 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Annual Plan-Ekm Dp - Malayattoor Division- Completion Of Kalarikkal Chira Drinking Water Supply Scheme In Manjapra Gp-To Replace Defective Motor Pump Sent And Other Electrical/Piping Accessories.-General Electrical Work

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 20-05-2026 Date Extended Date 21-05-2026

Key Dates

Publish Date 20-05-2026
Last Date of Bid Submission 21-05-2026
Tender Opening Date 21-05-2026

Contact Information

Company Name Local Self Government Department
Contact Person Executive Engineer
Address O/o the Executive Engineer, LSGD Division, Kakkanad, Ernakulam

BOQ Items

Name of Work:- Annual Plan-EKM DP - Malayattoor Division- Completion of Kalarikkal chira drinking water supply scheme in Manjapra GP-To replace defective motor pump sent and other electrical/piping accessories.-General Electrical Work
Sl. No. Item Description
1Electrification
290.14.1.1:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)
390.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
490.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
590.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
690.14.7:Supply and providing copper earth bus in the panel board
790.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
82.1.1:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N
92.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
10OD466468/2025-2026:Supply of 20A HRC Fuse Holder with 5 to 10 Amps fuse links
11OD466458/2025-2026:Supply of Blue colour LED indicator, AC/DC, 22.5 mm cut out dia
12OD466459/2025-2026:Supply of Red, Green, Black, Yellow, Orange colours LED indicator, AC/DC, 22.5 mm cut out dia
13OD466455/2025-2026:Supply and install three numbers of Current Transformer (CT) 100/5 suitable for 3 phase multifunction meter L&T WL440510OOOO or equivalent.
14OD466456/2025-2026:Supply and install V, A, F, PF, KW, KVA Multifunction meter 50 - 520 Volts, CT 1/5A, Flush mounting 96x96 mm, Accuracy Class 1.0, 0.5 L&T WL440510OOOO or equivalent.
15OD466596/2025-2026:Supply of 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
16OD466595/2025-2026:Supply of 16 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
17OD466561/2025-2026:Internal wiring of MV panel board using 1.5 to 10 Sqmm FRLS cable (Cables not included) using adequate cable terminals, properly dressing and using required cable protection etc,
1890.14.24.4:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.4 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Cylinderical Capacitor suitable for direct connection to motors.
1990.14.28.6:S & F Motor starters of the following ratingsFully automatic star delta starter for 15HP motor
2090.14.28.10:S & F Motor starters of the following ratingsSubmersible pump controllers with ammeter,DPMCB for single phase 0.5HP submersible motor pumps (DOL)
21OD466715/2025-2026:Supply of Monobloc Pump, 10 HP, Three Phase, 2900 rpm, 415 Volts, Size 100mm X 100mm, Head 18 to 29 meters, Discharge 15 to 28 lps, Cast iron body, Carbon steel shaft, CI/Noryl impellor Kirloskar KDS 1030++ or exact equivalent.
22OD255660/2025-2026:Installation of 10 HP mono block motor pump set on the existing concrete foundation, after properly fixing mounting bolts onto the concrete, aligning motor base to the mounting bolts correctly, using required set of nuts and washers, including handling of the pump set, including connecting and terminating the electrical power cables, test running the pump set satisfactorily, as per OEM specification, ensuring no leakage of water and adequate delivery of pump.
23OD467686/2025-2026:Supply of 100 mm dia. G.I. pipe (medium class)
24OD467758/2025-2026:Supply of GI 4 inch butt weld Bend
25OD467757/2025-2026:Supply of MS FLANGE TABLE 'E' 11MM THK, 100 NB
26OD467815/2025-2026:Supply of GI 4 inch butt weld TEE
27OD468638/2025-2026:Supply of 1 inch UPVC MTA
28OD468639/2025-2026:Supply of 1 inch UPVC Ball valve
29OD468640/2025-2026:Supply of 4 inch UPVC MTA
30OD255388/2025-2026:Supply of 12 mm Nylone rope
31OD467760/2025-2026:Supply of 100 mm C.I. SLUICE VALVE FLANGED PN1.0 AS PER IS: 14846, Make KARTAR or equivalent.
32OD255389/2025-2026:Supply of 4 inch PP Foot valve
33OD255390/2025-2026:Supply of 4 inch heavy duty GI Clip
34OD255391/2025-2026:Supply of 4 inch PP Hose Collar
35OD255392/2025-2026:Supply of 4 inch Green Hose, Duraflex or equivalent.
36OD255393/2025-2026:Supply of Shellak and Teflon
37OD255394/2025-2026:Supply of packing sheet
38OD467821/2025-2026:Supply of 110 mm UPVC tail end
39OD467761/2025-2026:Supply of M16/75 GI Bolt, Nut, washers set
4014.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
4114.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
4214.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
43OD255659/2025-2026:Inlet and delivery GI/PVC pipe work of already erected 10 HP motor pump set including fitment of all plumping accessories of suction and delivery lines, connecting the delivery to the main delivery line etc, including cutting welding, finishing , alignments etc. as required.
44OD257587/2025-2026:Supply installation testing and commissioning of 0.50 HP self-priming single phase motor pump set, Kirloskar MINI JALSENA-II (Gold), 0.5 HP, Single Phase, 220 Volts or equivalent, with suitable length suction and delivery side flexible hose, 25mm foot valve, hose connectors, hose clamp and accessories for priming arrangements.
4590.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point
46OD257599/2025-2026:Supply and providing LED bulb 9/12watts Philips/equivalent
471.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
481.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
491.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
501.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
511.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
521.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
531.17.33:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 6 sq. mm
541.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
5590.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
561.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
57OD468416/2025-2026:Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.(with charcoal/ coke and salt) as required
585.16:Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
595.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
6090.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
6190.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
6290.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
6390.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
6490.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
6590.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
66OD259722/2025-2026:Supply and providing 25x3 mm brass nut and bolt etc. as required.
672.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door
682.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
692.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
702.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
712.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
72OD259789/2025-2026:Supply and install weatherproof, outdoor, SMC meter box with MCB 430x215x150 Sintax GSMB 4422-1 or equivalent on the existing wall bracket near the KSEB post.
73OD259788/2025-2026:Supplying and fixing 63A, HRC Fuse Base with HRC Fuse link in the existing SMC meter box complete with connections, testing and commissioning etc. as required.
74OD259790/2025-2026:Supplying and fixing 63 amps amps rating, 240/415 volts, neutral link of two poles in the existing Meter box complete with connections, testing and commissioning etc. as required.
75OD467851/2025-2026:Preparation of drawings and copies, following up application procedures and liaising to obtain single phase KSEB connections, per pole. Please Enable Macros to View BoQ information

Other Detail

Information Source https://etenders.kerala.gov.in
Download FileName File Description File Size
Download BOQ_1437255.xls Tender Documents 0 KB
Download Requisitionfore-payment.pdf Tender Documents 0 KB
Download Tendernotice_1 (9).pdf Tender Documents 0 KB
Download viewsbd.pdf Tender Documents 0 KB
Download 886e0d22-3e4a-4e7a-85fc-d47de450b682.html Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.