Indian Tenders

Tender Notice

TDR 55441412
Tendering Authority Nagar Palika Nigam
Tender No Electrical/2026/2902 DT 08/05/2026
Tender ID 2026_UAD_506749_1
Tender Brief Tender For Supply Of Electrical Materials For The Repair And Maintenance Of Street Light
City Ashoknagar
State Madhya Pradesh
Document Fees INR 2000 /-
EMD INR 25418.0 /-
Tender Value INR 33.89 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Supply Of Electrical Materials For The Repair And Maintenance Of Street Light , Details , T-5 Power/Energy Saver 2X24w Choke , T-5 Power/Energy Saver 24W Ftl Tuberod , 2X24 T5-Holder , T5 Power Saver 2X24 Fixture Acrylic Transparent Cover , T5 Power Saver 4X24 Fixture Acrylic Transparent Cover , 150W Hpsv Choke , 150W Hpsv Lamp , Capacitor 33Mfd 250Vac 50 Hz , Electronic Ignitor Suitable For 150W Hpsv Lamps , 150W Holder (Porcelain) , Led Driver 50W Bis Certified , Led Mcpcb Plate 60W , Led Mcpcb Plate 50W , Led Mcpcb Plate 150W , Supplyingof Isi Marked And Approved Make Of Moulded Case Circuit Breaker(Mccb) Suitable For 3Phase,3Pole,50Hz,415 Volts, Ac Supply With Respective Interrupting Capacity(Ka) At 415 Volts Cited Against Their Range Standard Conforming To Is - 8828: 8.1Mccb With Breaking Capacity 25 Ka At 415 V: Current Rating -125 Amps & 70% -100% Adjustable , Supply Of Sovp Device Should Have Single High Capacity Varistor In The L-N Plug And Encapsulated Spark Gap For N-Pe, L-N Sovp Should Have A Rated Voltage Of Minimum 320V Ac To Handle Indian Power Supply Conditions. Sovp Should Have Visual Indication On Replaceable Varistor And Spark Gap Modules As Well As A Potential Free Contact On The Socket For Remote Indication. Sovp Device Should Be Wired Up As Per Tt Configuration Of Wiring In Accordance With En 61643-11 Standards. Both The L-N And N-Pe, Spds Should Be Rated For Handling 30Ka Of Nominal 8/20 Μs Surge Current.: Sovp For Pole Light Sub Feeder Panels - Type 2 Pluggable Spd 3+1, Rating L-N/N-Pe Uc 255/320 V In 30/60Ka Ka, Lmax 30Ka/60 Ka, Up 1.5Kv , Supplying Of Isi Marked And Accepted Standard Of Miniature Circuit Breaker(Mcb)Ofcseries Suitable For 240/415Volts,50Cycle,10 Ka Value Ac Supply Confirming To Is:8828:1996,Iec:60898 :2002 But Without Enclosures: Single Pole 63 Amp. , Astronomical Timer With Dst Feature , Contactor 3 Pole 90 annual periodical maintenance 50Hz 415Volts With No-Nc Contacts , Tpn Connector 150A , Supply Of Approved Make Powder Coated Sheet Steel Encloser Spn Mcb Db Inclusive Of Busbar,Neutral Bar,Earth Bar & Two Earth Terminals Etc. Complete As Per Is:13032 (Exclusive Of Mcb & Isolator): 8 Way Double Door , Supply Of Sovp Device Should Have Single High Capacity Varistor In The L-N Plug And Encapsulated Spark Gap For N-Pe, L-N Sovp Should Have A Rated Voltage Of Minimum 320V Ac To Handle Indian Power Supply Conditions. Sovp Should Have Visual Indication On Replaceable Varistor And Spark Gap Modules As Well As A Potential Free Contact On The Socket For Remote Indication. Sovp Device Should Be Wired Up As Per Tt Configuration Of Wiring In Accordance With En 61643-11 Standards. Both The L-N And N-Pe, Spds Should Be Rated For Handling 30Ka Of Nominal 8/20 Μs Surge Current.: Sovp For Pole Light - Type 2 Pluggable Spd 1+1, Rating L-N/N- Pe Uc 230/400 V In 5 Ka, Imax 10 Ka, Up 1.2Kv , Led Batten Tubelight 20W , Supplying Of Approved Make Tpn Mcbdb Metal Double Door With Provision For Fpmcb/Isolator/Rccb/Rcbo As Incomer And Sp Mcbs As Outgoing Inclusive Of Busbar,Neutral Bar,Earth Bar & Two Earth Terminals Etc. Complete As Per Is:13032 (Exclusive Of Mcb & Isolator ): 8 Way (8+24) , 8 Sq.Mm Multistrand Pvc Insulated Copper Wire Bundle 90Mtr , 1.Sq.Mm Aluminium Single Core Wire Bundle Of 100Mtr. Isi Marked , Xlpe Insulated Power Cable( Conforming Is-7098 Part-1) 1100 Volt Grade 2-Core Isi Marked With Alu. Stranded/Solid Conductor: 16 Sq.Mm Unarmoured , Xlpe Insulated Power Cable( Conforming Is-7098 Part-1) 1100 Volt Grade 4-Core Isi Marked With Alu. Stranded/Solid Conductor: 16 Sq.Mm Unarmoured , Xlpe Insulated Power Cable( Conforming Is-7098 Part-1) 1100 Volt Grade 1-Core Isi Marked With Alu. Stranded/Solid Conductor: 25Sq.Mm Unarmoured , Wooden Ladder 21Ft , Toolkit Set Consisting Of Different Sizes L-Keys, Screw Drivers, Testers And Plier Set. , Taperoll Box Consisting Of 30Pcs (Conforms To Is: 7809 (Part 3, Sec 1),Self Extinguishing,Protects From Electrolytic Corrosion,Excellent Water Resistance,Suitable For Primary Insulation Up To 440V)

Key Dates

Publish Date 12-05-2026
Last Date of Bid Submission 11-06-2026
Tender Opening Date 13-06-2026

Contact Information

Company Name Nagar Palika Nigam
Contact Person Chief Municipal Officer
Address Nagar Palika Office Ashoknagar

BOQ Items

Name of Work:- Supply of Electrical materials for the repair and maintenance of street light
Sl. No. Item Description
1Details
2T-5 POWER/ENERGY SAVER 2X24W CHOKE
3T-5 POWER/ENERGY SAVER 24W FTL TUBEROD
42X24 T5-HOLDER
5T5 POWER SAVER 2X24 FIXTURE ACRYLIC TRANSPARENT COVER
6T5 POWER SAVER 4X24 FIXTURE ACRYLIC TRANSPARENT COVER
7150W HPSV CHOKE
8150W HPSV LAMP
9CAPACITOR 33MFD 250VAC 50 Hz
10ELECTRONIC IGNITOR SUITABLE FOR 150W HPSV LAMPS
11150W holder (porcelain)
12LED DRIVER 50W BIS CERTIFIED
13LED MCPCB PLATE 60W
14LED MCPCB PLATE 50W
15LED MCPCB PLATE 150W
16Supplyingof ISI Marked and approved make of Moulded Case Circuit Breaker(MCCB) suitable for 3phase,3pole,50Hz,415 Volts, AC supply with respective interrupting capacity(KA) at 415 Volts cited against their range standard conforming to IS - 8828: 8.1MCCB with Breaking Capacity 25 KA at 415 V: Current Rating -125 Amps & 70% -100% adjustable
17Supply of SOVP Device should have Single High Capacity Varistor in the L-N Plug and Encapsulated Spark Gap for N-PE, L-N SOVP should have a Rated Voltage of Minimum 320V AC to handle Indian Power Supply conditions. SOVP Should have Visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. SOVP device should be wired up as per TT configuration of wiring in accordance with EN 61643-11 Standards. Both the L-N and N-PE, SPDs should be rated for handling 30KA of nominal 8/20 μs surge current.: SOVP for Pole Light Sub Feeder Panels - Type 2 Pluggable SPD 3+1, Rating L-N/N-PE Uc 255/320 V In 30/60KA KA, lmax 30Ka/60 KA, Up 1.5KV
18Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker(MCB)of'C'series suitable for 240/415Volts,50Cycle,10Ka Value AC supply confirming to IS:8828:1996,IEC:60898 :2002 but without enclosures: SINGLE POLE 63 AMP.
19ASTRONOMICAL TIMER WITH DST FEATURE
20CONTACTOR 3 POLE 90 AMP 50HZ 415VOLTS WITH NO-NC CONTACTS
21TPN connector 150A
22Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of Busbar,Neutral bar,Earth bar & two earth terminals etc. complete as per IS:13032 (exclusive of MCB & isolator): 8 way double door
23Supply of SOVP Device should have Single High Capacity Varistor in the L-N Plug and Encapsulated Spark Gap for N-PE, L-N SOVP should have a Rated Voltage of Minimum 320V AC to handle Indian Power Supply conditions. SOVP Should have Visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. SOVP device should be wired up as per TT configuration of wiring in accordance with EN 61643-11 Standards. Both the L-N and N-PE, SPDs should be rated for handling 30KA of nominal 8/20 μs surge current.: SOVP for Pole Light - Type 2 Pluggable SPD 1+1, Rating L-N/N- PE Uc 230/400 V In 5 KA, Imax 10 KA, Up 1.2KV
24LED BATTEN TUBELIGHT 20W
25Supplying of approved make TPN MCBDB Metal Double Door with provision for FPMCB/Isolator/RCCB/RCBO as incomer and SP MCBs as outgoing inclusive of Busbar,Neutral bar,Earth bar & two earth terminals etc. complete as per IS:13032 (exclusive of MCB & isolator ): 8 way (8+24)
268 SQ.MM MULTISTRAND PVC INSULATED COPPER WIRE BUNDLE 90MTR
271.SQ.MM ALUMINIUM SINGLE CORE WIRE BUNDLE OF 100MTR. ISI MARKED
28XLPE INSULATED POWER CABLE( CONFORMING IS-7098 PART-1) 1100 VOLT GRADE 2-CORE ISI MARKED WITH ALU. STRANDED/SOLID CONDUCTOR: 16 SQ.MM UNARMOURED
29XLPE INSULATED POWER CABLE( CONFORMING IS-7098 PART-1) 1100 VOLT GRADE 4-CORE ISI MARKED WITH ALU. STRANDED/SOLID CONDUCTOR: 16 SQ.MM UNARMOURED
30XLPE INSULATED POWER CABLE( CONFORMING IS-7098 PART-1) 1100 VOLT GRADE 1-CORE ISI MARKED WITH ALU. STRANDED/SOLID CONDUCTOR: 25SQ.MM UNARMOURED
31WOODEN LADDER 21ft
32TOOLKIT SET CONSISTING OF DIFFERENT SIZES L-KEYS, SCREW DRIVERS, TESTERS AND PLIER SET.
33TAPEROLL BOX CONSISTING OF 30PCs (Conforms to IS: 7809 (Part 3, Sec 1),Self extinguishing,Protects from electrolytic corrosion,Excellent water resistance,Suitable for primary insulation up to 440V) Please Enable Macros to View BoQ information

Other Detail

Information Source https://mptenders.gov.in/nicgep/app
Download FileName File Description File Size
Download BOQ_610441.xls Tender Documents 0 KB
Download c1a0e9e4-e1ac-44f2-91f6-728d3a7fdc46.html Tender Documents 0 KB
Download Tendernotice_1 (9).pdf Tender Documents 0 KB
Download Tendernotice_2 (2).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.