Tender Brief Corrigendum : Tender For Repair And Maintenance Of Certain Cooling Appliances Of Zone-I Under Ge (A) Jaisalmer
City Jaisalmer
State Rajasthan
Document Fees INR 500 /-
EMD INR 80000.0 /-
Tender Value INR 40 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Repair And Maintenance Of Certain Cooling Appliances Of Zone-I Under Ge (A) Jaisalmer

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 30-05-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-06-2026

Key Dates

Publish Date 30-05-2026
Last Date of Bid Submission 06-06-2026
Tender Opening Date 08-06-2026

Contact Information

Company Name Military Engineer Services
Contact Person GE Army Jaisalmer
Address GE Army Jaisalmer - 345001

BOQ Items

Name of Work:- REPAIR AND MAINT OF CERTAIN COOLING APPLIANCES OF ZONE-I UNDER GE (A) JAISALMER
Sl. No. Item Description
1Taking down the desert cooler of any capacity from stand/slab for painting, clean the inner and outer surface of desert cooler with wire brush and made free from dust and sludge with wire brush in and including applying two coat of synthetic enamel paint over a coat of primer complete all as specified & directed by the Engineer-in-charge.
2Taking out fan motor single phase 230 Volts, 1400 RPM 3 speed 1/8 HP from desert cooler and rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with 'E' class varnish, including replacement of gun metal bushes and reassembling and fixing in position complete all all as specified & directed by the Engineer-in-charge.
3S&F in repair fan motor single phase 230 Volts, 1400 RPM 3 speed 1/8 HP copper wire winding for desert cooler complete all all as specified & directed by the Engineer-in-charge.
4S&F in repair, top of desert cooler , of any capacity, fabricated out of 1 mm thick mild steel galvanised iron sheet including gas welding at joints in and including applying two coat of synthetic enamel paint over a coat of primer complete all as specified & directed by the Engineer-in-charge.
5S&F in repair, front side grill of desert cooler of any capacity, fabricated out of 1 mm thick mild steel galvanised iron sheet including gas welding at joints in and including applying two coat of synthetic enamel paint over a coat of primer complete all as specified & directed by the Engineer-in-charge.
6S&F in repair, side/back shutter fabric item made out of 1 mm thick galvanised iron sheet of size suitable for desert cooler of air delivery capacity 4000/5000 Cum/hour in and including applying two coat of synthetic enamel paint over a coat of primer complete all as specified & directed by the Engineer-in-charge.
7S&F in repair, corner of the desert cooler made out of 1 mm thick galvanised iron sheet of size suitable for desert cooler height as per the existing (up to 1.2 M) including applying two coat of synthetic enamel paint over a coat of primer complete all as specified & directed by the Engineer-in-charge.
8S&F in repair, bottom tank of desert cooler , of any capacity, fabricated out of 1 mm thick mild steel galvanised iron sheet with gas welding at joints in and including applying two coat of synthetic enamel paint over a coat of primer complete all as specified & directed by the Engineer-in-charge.
9S&F in repair, Front panel on which Desert cooler motor mounted on inner side and grill will be mounted on front side of panel including the empty switch & regulator box of desert cooler of any capacity, fabricated out of 1 mm thick mild steel galvanised iron sheet including gas welding at joints in and including applying two coat of synthetic enamel paint over a coat of primer complete all as specified & directed by the Engineer-in-charge.
10S &F in repair, Front plate of desert cooler complete all as specified & directed by Engineer-in-charge.
11S&F in repair, PVC flexible pipe of 16 mm outer dia complete for desert cooler all as specified & directed by Engineer-in-charge.
12S &F in repair, desert cooler selector switches three way 230 volts single phase complete all as specified & directed by Engineer-in-charge.
13S &F in repair, wood wool pad size of 36\\" x 24\\" (Set of three) fixed in three sides panel of desert cooler including the iron wire cage cover to hold the wood pool in panels complete all as specified & directed by Engineer-in-charge.
14S&F in repair, plug top 3 pin 5 amps, 230 volts (ISI marked) complete all as specified & directed by Engineer-in-charge. Make C&S/ Anchor/Legrand/L&T or equivalent
15S&F in repair,switch piano type 240 volts, single pole one way 5 amps complete all as specified & directed by Engineer-in-charge. Make- Anchor/Wipro/Havells or equivalent
16S&F in repair PVC insulated and PVC sheathed round flexible three core copper conducter cable suitable for upto 10 Amp with plug top and 1.5 mtr length minimum complete all as specified & directed by Engineer-in-charge.Make-Anchor/Havells/Staranded or equvalent
17S&F in repair, capacitor suitable for 4000/5000/6000 cfm for fan motor of desert coolers complete all as specified & directed by Engineer-in-charge. Make-Epcos/Bajaj/ Havells/CG
18S&F in repair, submersible pump PVC body 230 volts, 18 W, 1.6 m head.0.025HP of desert cooler complete all as specified & directed by Engineer-in-charge. Make- khaitan zolta
19S&F in repair, MS fan blade, powder coated for fan motor of desert cooler 20 inch swee, 5mm thickness complete all as specified & directed by Engineer-in-charge.
20S&F in repair, legs of desert cooler including of nuts& bolts suitable for desert coolers complete all as specified & directed by Engineer-in-charge.
21S&F in repair, cast iron ring for desert cooler fan motor with clamps & nuts& bolts suitable for desert coolers complete all as specified & directed by Engineer-in-charge.
22S&F in repair, Flexible copper wire of 1.5 sqmm for connection of different item of desert cooler complete including connecting and testing all as specified & directed by Engineer-in-charge.
23S&F in repair, PVC 2 way elbow distributor suitable for 15 mm flexble pipe with nuts and screws for desert coolers complete all as specified & directed by Engineer-in-charge.
24S&F in repair, PVC 3 way distributor suitable for 15 mm flexble pipe with nuts and screws for desert coolers complete all as specified & directed by Engineer-in-charge.
25S&F in repair fan motor suitable for water cooler of capacity 40/80 ltr to 150/180 ltr, copper wound complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
26S&F in repairs fan blade suitable for water cooler of capacity 40/80 Ltr to 150/180 liters complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
27S&F in repair, Capacitor of any capacity and any type (suitable or as per existing sample) for water coolers/refrigerator/deep freezer complete all as specified & directed by Engineer-in-charge. Make-As per existing make and model
28S&F in repairs float valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for 15 mm bore iron pipe, weight not less than 140 grams/each, suitable for water/desert coolers complete all as specified & directed by Engineer-in-charge. Make- Prayag or equivalent as approved by GE
29S&F in repairs any size water tap, cast copper alloy, chromium plated push type suitable for water cooler of any capacity complete all as specified & directed by Engineer-in-charge. Make- (Existing make or equivalent)
30S&F in repair, relay and over load protector set suitable for water cooler/refrigerator/split ac/deep freezer of any capacity complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
31M&L for cutting and removing unservicable freezer unit of refrigerator capacity 150 to 284 Litres of any make, and supply and fix new freezer unit including jointing, brazing, recharging of refrigerant gas and testing for smooth functioning complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
32M&L for cutting and removing unservicable freezer unit of refrigerator capacity 285 to 400 Litres of any make, and supply and fix new freezer unit including jointing, brazing, recharging of refrigerant gas and testing for smooth functioning complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
33S&F in repairs thermostat suitable for refrigerator/water cooler/deep freezer of ANY capacity complete all as specified & directed by Engineer-in-charge. Make-Make- As per existing make and model
34M&L for servicing of spilt type AC of capacity 1.5/2TR of any make by opening the condenser unit fixed on outside and cooling unit fixed inside the building,and cleaning (Including complete pressurized chemical washing with pressure pump and plastic bag covering avoid dust & water spreading) the complete condensor unit and cooling unit including fins and checking/testing of all parts for its serviceability, and rectification of unusual noise of motors, checking of refrigerant standing pressure, replacement of minor parts such as nut/bolt washers etc and reassembling of complete unit including testing for smooth functioning complete all as specified & directed by Engineer-in-charge.
35M&L for shifting of spilt type AC of capacity 1.5/2TR of any make by opening the indoor and outdoor unit complete with accessories and fittings including filling of drilled hole of wall using high quality plaster and transporting the AC to the site where it is to be installed, installing the AC at site in and including making necessary drilling in wall making electrical connections indoor/outdoor unit and checking/testing of all parts for its serviceability and rectification of unusual noise of motors, checking of refrigerant standing pressure, topping of refrigerant upto the required level, replacement of minor parts such as nut/bolt washers etc and reassembling of complete unit including testing for smooth functioning complete all as specified & directed by Engineer-in-charge.
36S&F in repair single pole contactor of any capacity suitable for 1.5/ 2 TR split / window ac of both type AC /DC complete including testing commissioning complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
37S&F in repair outdoor / blower fan motor of any capacity and type of copper wound suitable for split type AC1.5 /2 TR, AC/DC complete including testing commissioning complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
38S&F in repair capacitor any capacity and any type (3/ 4 pin/6 pin or existing) suitable for split AC and window ac of both type AC and DC of capacity 1.5/2 TR complete all as specified & directed by Engineer-in-charge. Make-As per existing make and model
39S&F in repair Stand of outdoor unit of split ac with complete nut bolt etc. , suitable for any type of split ac as avaliable on site complete all as specified and directed by engg-in-charge.
40Repair/Replacement of refrigerator fan motor suiable of capacity upto 400 ltr complete including testing complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model.
41S&F in repair, drain out pipe of split AC of PVC, heavy duty of 15 mm dia and 1.5 mm wall thickness complete with fittings,spacer and saddles etc complete all as specified & directed by Engineer-in-charge.
42S&F in repair, blower/ outdoor fan blade of any type split type AC 1.5/2 TR capacity complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
43S&F in repairs remote control (Micro processor) unit suitable for split type AC 1.5/2 TR capacity complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
44S&F in repair, of thermostat suitable for split/window type AC 1.5/2 TR capacity complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
45Cutting and taking out compressor of split type AC of 1.5 TR and supply and fixing the compressor with jointing of copper refrigent pipe line in and including charging of refrigerant gas to required level , NRV VALVE ,RELAY AND OVERLOAD RALAY AND CAPILLARY, FILTER AND BRIZING complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
46Cutting and taking out compressor of split type/ Cassette AC of 2TR and supply and fixing the suitable compressor with jointing of copper refrigerant pipe line in and including charging of refrigerant gas to required level , NRV VALVE ,RELAY AND OVERLOAD RALAY AND CAPILLARY, FILTER AND BRIZING complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
47S&F in repair, copper condenser coil suitable for split/Cassete type AC of capacity 1.5 TR complete including top up gas charging and checking all as specified & directed by Engineer-in-charge. Make- As per existing make and model
48S&F in repair, copper condenser coil suitable for split/Cassete type AC of capacity 2 TR complete including top up gas charging and checking all as specified & directed by Engineer-in-charge. Make- As per existing make and model
49S&F in repair, plug top three pin 15/16 Amps 230 volts AC complete all as specified & directed by Engineer-in-charge.
50S&F in repair, Air Filter for Air conditioner split type having capacity1.5/2.0 ton (Set of 3 pieces) complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
51S&F in repair, PCB suitable to Split/Cassette type AC 2 TR complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
52S&F in repair, PCB suitable to Split/Cassette type AC 1.5 TR complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
53S&F in repair, INDOOR PCB suitable for DC invertor type Split/Cassette type AC 2 TR complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
54S&F in repair,INDOOR PCB suitable for DC invertor type Split/Cassette type AC 1.5TR complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
55S&F in repair,OUTDOOR PCB suitable for DC invertor type Split/Cassette type AC 2 TR complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
56S&F in repair,OUTDOOR PCB suitable for DC invertor type Split/Cassette type AC 1.5TR complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
57S&F in repair, PCB suitable to invertor refrigerator to any capacity complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
58S&F in repair copper tube size 1/4\\" of split AC having capacity 1.5/2 ton complete with PUF insulation all as specified & directed by Engineer-in-charge.
59S&F in repair copper tube size 1/2\\" of split AC having capacity 1.5/2 ton complete with PUF insulation all as specified & directed by Engineer-in-charge.
60S&F in repair insulation for copper tube suitable for split AC 1.5/2 TR complete all as specified & directed by Engineer-in-charge.
61S&F in repair for indoor motor of any type and any capacity for suitable of split AC of both type AC and DC any make any type all as per sample all as specified & directed by Engineer-in-charge
62S&F in repair for split AC valve of ½” dia all as per sample all as specified & directed by Engineer-in-charge
63S&F in repair for split AC valve of ¼” dia all as per sample all as specified & directed by Engineer-in-charge
64S&F in repair, fan motor for deep freezer of any type and any capacity complete suitable for deepfeezer all as specified & directed by Engineer-in-charge. Make- As per existing make and model
65Cutting and taking out compressor of deep freezer of capacity 150 to 210 Ltr and supply and fixing the compressor with jointing of copper refrigent pipe line in andincluding charging of refrigerant gas to required level , NRV VALVE ,RELAY AND OVERLOAD RALAY AND CAPILLARY, FILTER AND BRIZING complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
66Cutting and taking out compressor of deep freezer of capacity 215 to 380 Ltr and supply and fixing the compressor with jointing of copper refrigent pipe line in andincluding charging of refrigerant gas to required level , NRV VALVE ,RELAY AND OVERLOAD RALAY AND CAPILLARY, FILTER AND BRIZING complete all as specified & directed by Engineer-in-charge.. Make- As per existing make and model
67Cutting and taking out compressor of water cooler of capacity 40/80 Ltr and supply and fixing the compressor with jointing of copper refrigent pipe line in and including charging of refrigerant gas to required level , NRV VALVE ,RELAY AND OVERLOAD RALAY AND CAPILLARY, FILTER AND BRIZING complete all as specified & directed by Engineer-in-charge. . Make- As per existing make and model
68Cutting and taking out compressor of water cooler of capacity 60/120 Ltr and supply and fixing the compressor with jointing of copper refrigent pipe line in and including charging of refrigerant gas to required level , NRV VALVE ,RELAY AND OVERLOAD RALAY AND CAPILLARY, FILTER AND BRIZING complete all as specified & directed by Engineer-in-charge. . Make- As per existing make and model
69Cutting and taking out compressor of water cooler of capacity 150/180 Ltr and supply and fixing the compressor with jointing of copper refrigent pipe line in and including charging of refrigerant gas to required level , NRV VALVE ,RELAY AND OVERLOAD RALAY AND CAPILLARY, FILTER AND BRIZING complete all as specified & directed by Engineer-in-charge. . Make- As per existing make and model
70Cutting and taking out compressor of refrigerator(ordinary/invertor type) of capacity 285 to 400 litres of any make, & replacing the same compressor with new of same make of model complete, re-installing in original position with all accessoriesincluding charging of refrigerant gas to required level , NRV VALVE ,RELAY AND OVERLOAD RALAY AND CAPILLARY, FILTER AND BRIZING complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
71Cutting and taking out compressor of refrigerator(ordinary/invertor type) of capacity 150 to 215 litres of any make, & replacing the same compressor with new of same make of model complete, re-installing in original position with all accessories including charging of refrigerant gas to required level , NRV VALVE ,RELAY AND OVERLOAD RALAY AND CAPILLARY, FILTER AND BRIZING complete all as specified & directed by Engineer-in-charge. . Make- As per existing make and model
72Cutting and taking out compressor of refrigerator (ordinary/invertor type)of capacity 220 to 280 litres of any make, & replacing the same compressor with new of same make of model complete, re-installing in original position with all accessories including charging of refrigerant gas to required level , NRV VALVE ,RELAY AND OVERLOAD RALAY AND CAPILLARY, FILTER AND BRIZING complete all as specified & directed by Engineer-in-charge. . Make- As per existing make and model
73S&F in repair, capillary tube with filter suitable for any make & capacity water cooler/refrigerator/ AC complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model.
74Supply & charging of refrigerant gas R-22 (freon) for charging in Refrigerator/water cooler/DF/ window/split type AC of 1.5/2 TR capacity complete and checking of leakage, testing for proper functioning all as specified & directed by Engineer-in-charge.
75Supply & charging of refrigerant gas R-410A for charging in Refrigerator/water cooler/DF/ window/split type AC of 1.5/2 TR capacity complete and checking/testing for proper functioning all as specified & directed by Engineer-in-charge.
76Supply & charging of refrigerant gas R-134C (freon) for rRefrigerator/water cooler/DF/ window/split type ACs of any capacity complete and checking/testing for proper functioning all as specified & directed by Engineer-in-charge.
77Supply & charging of refrigerant gas R-32 (freon) for Refrigerator/water cooler/DF/ window/split type ACs of any capacity complete and checking/testing for proper functioning all as specified & directed by Engineer-in-charge.
78Supply & charging of refrigerant gas 600A for refrigarator/water cooler /deep freezer of any capacity complete and checking/testing for proper functioning all as specified & directed by Engineer-in-charge.
79S&F in repair MCB SP 25 Amps protected plug top & socket, Ac Box , 240 Volts complete all as specified & directed by Engineer-in-charge.
80S&F in repair NRV VALVE for Refrigerator/water cooler/DF/ window/split type AC of any capacity complete all as specified and directed by Engineer-in charge.
81S&F in repair voltage stablizer of 5-KVA suitable for split/ window ac of 1.5/2 TR complete all as specified and directed by Engineer-in-charge. Make- V-GUARD/MICROTECH/PIXELS
82S&F in repair flexible copper cable of 2.5 sqmm 3- core complete suitable for split ac all as specified and directed by Engineer-in-charge.
83S&F in repair FAIR NUTS of any size for window/split type AC of any capacity complete all as specified and directed by Engineer-in charge.
84M&L in replacement indoor unit suitable for 1.5 ton split air conditioner complete.
85M&L in repair/servicing for voltage stablizer including removing from the wall and after repairing fixing the same at same location as specified and directed by engg-in-chagre.
86Labour only for attending split ac/ refrigrator/deep freezer/ water cooler etc complaints.including minor repair such as leakage recitfication of copper condensor tubes and copper tubes, brizing etc .complete all as specified and directed by engg-in-chagre.
87M&L in repair for outdoor unit (casing) suitable for 1.5 tone split AC (with out compressor). MS body, self standing.including condensor, suction & dischage valve, fan motor, fan blade, connecting copper tube and connector with connecting wiring kit, flair nut and valve of different size as required complete all as specified and directed by Engineer-in charge. Please Enable Macros to View BoQ information
88M&L in repair for outdoor unit (casing) suitable for 1.5 tone split AC (with out compressor). MS body, self standing.including condensor, suction & dischage valve, fan motor, fan blade, connecting copper tube and connector with connecting wiring kit, flair nut and valve of different size as required complete all as specified and directed by Engineer-in charge. Please Enable Macros to View BoQ information

Other Detail

Information Source https://defproc.gov.in/nicgep/app
Download FileName File Description File Size
Download BOQ_856319.xls Tender Documents 0 KB
Download c41b9ab8-2812-42be-a8fb-e58116269983.html Tender Documents 0 KB
Download TenderDocuments8593.pdf Tender Documents 0 KB
Download Tendernotice_1 (1).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.