Indian Tenders

Tender Notice

TDR 55425377
Tendering Authority Military Engineer Services
Tender No GE/JHA/TOK/16 OF 2026-27
Tender ID 2026_MES_764371_1
Tender Brief Corrigendum : Tender For Repair/Replacement And Maintenance Of Ac Plant, Air Conditioners, Refgn, Deep Freezer, Walk In Cooler & Water Cooler, Desert Cooler And Their Connected Works At Jhansi Cantt, Aau & Caleb Vihar Area Under Age E/M At Ge Jhansi
City Jhansi
State Uttar Pradesh
Document Fees INR 500 /-
EMD INR 74000.0 /-
Tender Value INR 37 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Repair/Replacement And Maintenance Of Ac Plant, Air Conditioners, Refgn, Deep Freezer, Walk In Cooler & Water Cooler, Desert Cooler And Their Connected Works At Jhansi Cantt, Aau & Caleb Vihar Area Under Age E/M At Ge Jhansi

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 30-05-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-06-2026

Key Dates

Publish Date 30-05-2026
Last Date of Bid Submission 06-06-2026
Tender Opening Date 08-06-2026

Contact Information

Company Name Military Engineer Services
Contact Person Maj Rajesh Rathore
Address Garrison Engineer Jhansi

BOQ Items

Name of Work:- REPAIR/REPLACEMENT AND MAINT OF AC PLANT, AIR CONDITIONERS, REFGN, DEEP FREEZER, WALK IN COOLER & WATER COOLER, DESERT COOLER AND THEIR CONNECTED WORKS AT JHANSI CANTT, AAU & CALEB VIHAR AREA UNDER AGE E/M AT GE JHANSI
Sl. No. Item Description
1M&L for Servicing of window type AC 1.5 / 2.0 TR capacity, any type/make, by carefully taking down from window / wall, removing power connection, front PVC grill, air filters and applying air blower to remove all dust, washing, cleaning, removing dirt, including cleaning and washing of cooling and condenser coil, re-assembling the dismantled components, refixing to its original position and testing for proper functioning complete all as specified and directed by Engineer-in-Charge.
2M&L for servicing of split type AC of 1.5 / 2.0 TR capacity, any type/make, in situ at installed location, removing power connection, carefully opening the indoor and outdoor unit, removing filters, applying blower in both the units to remove all dust, cleaning, washing, removing dirt, including cleaning and washing of evaporator coil of indoor cooling unit and condenser coil of outdoor unit, re-assembling the dismantled components, refixing to its original position and testing for proper functioning complete all as specified and directed by Engineer-in-Charge.
3Supply and fix in replacement of set of PVC filters suitable for window type AC 1.5 Ton / 2.0 TR capacity of existing model complete all as specified and directed and by Engineer-in-Charge.
4Supply and fix in replacement of set of PVC filters suitable for indoor unit of split type AC 1.5 Ton / 2.0 TR capacity of existing model complete all as specified and directed and by Engineer-in-Charge.
5Supply and fix in replacement of following spare parts suitable for indoor unit of split type AC 1.5 Ton / 2.0 TR capacity of existing model complete all as specified and directed and by Engineer-in-Charge.
6Blower bush
7Blower fan blades
8Blower motor
9Display unit
10Swing motor
11Capacitor 1.0 mdf to 2.5 mfd suitable for blower motor
12Supply and fix in replacement of suction / discharge valve, brass, of size 1/4'' to 3/4'' suitable for outdoor unit of split type AC 1.5 Ton / 2.0 TR capacity / suction / discharge valve of package type AC plant of existing model suitable for 5.5 TR / 11 TR capacity / walk-in-cooler of capacity 2.0 TR complete all as specified and directed and by Engineer-in-Charge.
13Supply and fix in replacement of thermostat temperature sensor suitable for indoor unit of split type AC / window type AC 1.5 Ton / 2.0 TR capacity of existing model / package type AC plant of existing model suitable for 5.5 TR / 11 TR capacity / walk-in-cooler of capacity 2.0 TR complete all as specified and directed and by Engineer-in-Charge.
14Supply and fix in replacement of PCB with display unit suitable for window type AC 1.5 TR / 2.0 TR capacity of existing model complete all as specified and directed and by Engineer-in-Charge.
15Supply and fix in replacement of following spare parts suitable for window type / outdoor unit of split type Air conditioners of existing model complete all as specified and directed and by Engineer-in-Charge.
16Hermetically sealed reciprocating type / rotary type compressor unit 1.5 TR capacity including gas charging complete
17Hermetically sealed reciprocating type / rotary type compressor unit 2.0 TR capacity including gas charging complete
18Running capacitor 35 mfd to 60 mfd
19Fan motor, copper wound
20Fan blades
21Fan capacitor 4.0 mfd to 6.0 mfd
22Flair nuts of suitable sizes of existing unit
23Supply and fix in replacement of copper condenser coil suitable for outdoor unit of 1.5 / 2.0 TR capacity split type / window type Air conditioners of existing model complete all as specified and directed and by Engineer-in-Charge.
24Supply and fix in replacement of single phase contactor suitable for 1.5 / 2.0 TR capacity split type Air conditioners / Walk-in-cooler of existing model complete all as specified and directed and by Engineer-in-Charge.
25Supply and fix in replacement of window AC Kit, company made, consist of metal sheet enclosure / housing, cooling coil, condenser coil, PVC front grill, wiring kit, Fan motor, condenser fan and blower, PCB and remote hand set etc complete, suitable for air conditioner of 1.5 TR capacity complete all as specified and directed by Engineer-in-Charge.
26M&L for gas charging of Air Conditioner window / split type / walk-in-cooler of capacity 1.5 / 2.0 TR with R - 22 / R-32 /R-410a or any other recommended refrigerant gas, including detecting of leakage, repairing using welding/brazing, pressure testing, replacement of connection lead, tin coated copper thimbles etc and testing for proper cooling including six month top up warranty etc complete all as specified and directed and by Engineer-in-Charge.
27Supply and fix in replacement of copper tube of size 1/4'' to 1/2'' suitable for 1.5 / 2.0 TR capacity split type Air conditioners / walk-in-cooler / Central / package type AC of existing model complete all as specified and directed and by Engineer-in-Charge.
28Supply and fix in replacement of nitrile rubber foam insulation of size 1/4'' to 1/2'' suitable for 1.5 / 2.0 TR capacity split type Air conditioners of existing model complete all as specified and directed and by Engineer-in-Charge.
29Supply and fix in replacement of PVC front grill suitable for 1.5 / 2.0 TR capacity window type Air conditioners of existing make / model complete all as specified and directed and by Engineer-in-Charge.
30Supply and testing in replacement of remote control unit with batteries suitable for 1.5 / 2.0 TR capacity split type / window type Air conditioners of existing model complete all as specified and directed and by Engineer-in-Charge.
31Supply and fix in replacement of PVC insulated and PVC sheathed 3 core x 2.5 sqmm stranded copper conductor conforming to IS:694 complete all as specified and directed by Engineer-in-Charge.
32Supply and fix in replacement of indoor cooling unit invertor/non inverter complete with evaporator coil, blower motor with fan, PCB with display and remote control unit suitable for split air conditioner of 1.5 TR capacity with and including making connection etc complete all as specified and directed by Engineer-in-Charge.
33All as per item No. 18.00 here-in-before but of capacity 2.0 TR.
34Supply and fix in replacement of 20A rated metal clad plug, 2 pin plus earth suitable for metal clad plug & socket board, 230V, AC complete all as specified and directed by Engineer-in-Charge.
35Supply and fix in replacement of 20A rated metal clad socket, 2 pin plus earth suitable for metal clad plug & socket board, 230V, AC complete all as specified and directed by Engineer-in-Charge.
36Supply and fix in replacement of MCB, SP, 6-32A, 'C' curve complete all as specified and directed by Engineer-in-Charge.
37Supply and fix in replacement of Plug top, 3 pin, 20 Amps, single phase, 230 volts, 50 Hz complete all as specified and directed.
38Supply and fix in replacement of heavy duty Mild Steel powder coated wall mount bracket with grouting bolts complete set suitable for wall mounting of outdoor unit of 1.5 / 2.0 TR capacity split type AC complete all as specified and directed by Engineer-in-Charge.
39Supply and fix in replacement of PVC drain pipe 1/2'' size including proper clamping on wall surfaces suitable for 1.5 / 2.0 TR capacity split type AC complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information
40Supply and fix in replacement of PVC drain pipe 1/2'' size including proper clamping on wall surfaces suitable for 1.5 / 2.0 TR capacity split type AC complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information

Other Detail

Information Source https://defproc.gov.in/nicgep/app
Download FileName File Description File Size
Download 2f8a148a-9edc-4513-80d5-bf82954f1b1e.html Tender Documents 0 KB
Download BOQ_856135.xls Tender Documents 0 KB
Download TenderDocuments16.pdf Tender Documents 0 KB
Download Tendernotice_1 (1).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.