Indian Tenders

Tender Notice

TDR 55425250
Tendering Authority Military Engineer Services
Tender No GE/LDH-08/2026-27
Tender ID 2026_MES_764199_1
Tender Brief Corrigendum : Tender For Repair And Maintenance To Summer Appliances And Misc E/M Items At Baddowal, Moga, Cg Complex And Doraha Under Ge Ludhiana
City Ludhiana
State Punjab
Document Fees INR 500 /-
EMD INR 60000.0 /-
Tender Value INR 30 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Repair And Maintenance To Summer Appliances And Misc E/M Items At Baddowal, Moga, Cg Complex And Doraha Under Ge Ludhiana

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 30-05-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-06-2026
2 18-05-2026 Corrigendum_1 Other 30-05-2026

Key Dates

Publish Date 30-05-2026
Last Date of Bid Submission 06-06-2026
Tender Opening Date 08-06-2026

Contact Information

Company Name Military Engineer Services
Contact Person Garrison Engineer Ludhiana
Address Garrison Engineer Military Engineer Services Near Jagraon Bridge Ludhiana-141001 (Punjab)

BOQ Items

Name of Work:- REPAIR AND MAINT TO SUMMER APPLIANCES AND MISC E/M ITEMS AT BADDOWAL, MOGA, CG COMPLEX AND DORAHA UNDER GE LUDHIANA
Sl. No. Item Description
1Sch 'A'
2Supply and replacement of PCB for BLDC ceiling fan 1200/1400 mm complete all as specified and directed.
3Supply and replacement of Rotor for BLDC ceiling fan 1200/1400 mm complete all as specified and directed.
4M&L for Painting of ceiling fans completeds in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed.
5M&L for taking down ceiling fan for repair of any make/model of sweep 1200/1400 mm by removing burnt/heated winding from stator and rewinding the stator coils with super enamelled copper wire of suitable size including providing insulation material, varnishing and provision of cotton tape, re-assembling and testing including replacement of spring washer and two core flexible wire of size 0.50 sq mm with copper conductor of suitable upto 1.50 m length from fan terminal to ceiling rose including replacement of gun metal bush, bearing set and capacitor & refiixing the same after repair complete all as specified and directed.
6M&L for taking out exhaust fan for repair of any make/ model of sweep 250 mm to 300 mm by removing burnt / heated winding from stator and rewinding the stator coils with super enamelled copper wire of suitable size including providing insulation material, varnishing and provision of cotton tape, re-assembling and testing including replacement of shaft and bearing of suitable size (ISI marked), mounting lugs and two core flexible wire of size 0.50 sq mm with copper conductor of suitable upto 1.50 m length from fan terminal to ceiling rose gun metal bush, bearing set and capacitor & refiixing the same after repair complete all as specified and directed.
7All as per item No. 5 above but exhaust fan 380 mm to 450 mm sweep size complete all as specified and directed.
8S&F in replacement Socket outlet 15 Amps, flush type complete all as specified and directed.
9Supply and fixing Heavy duty, exhaust fans steel body of 300 mm sweep with blades, and frame and louvers,1400 RPM ISI Marked suitable for SP 230/250V 50 Hz AC supply complete including fixing/grouting of frame in wall and cutting opening complete and connectin with and including 3 core 1.5 sq mm single core, PVC insulated but unsheathed FRLS cable with multistranded copper conductors from ceiling rose to fan complete all as specified and directed.
10Material and labour taking down ceiling fan of any make and model having sweep 1200mm/ 1400mm fixed in buildings at various locations for minor repair as opening fan rotor, cleaning with kerosine oil, greasing and re-fixing in existing location including replacement of cotter pin/ split pins, capacitor, canopies, refixing the same after repair complete all as specified and directed.
11Material and labour taking down exhaust fan having sweep 250 mm to 450 mm fixed in buildings at various locations for minor repair as opening fan rotor, cleaning with kerosine oil, greasing and re-fixing in existing location including replacement of mounitng legs, louving shutter, capacitor, ball bearing, gun metal bush, rubber vibrating pads & refixing the same after repairs complete all as specified and directed.
12Supply and replacement of fan capacitor 3.15 mfd complete all as specified and directed.
13Supply and replacement of fan capacitor 4.0 mfd complete all as specified and directed.
14S& F in replacement of set of blades for ceiling fan 1200/1400mm sweep duly screwed with spring washers of make as per existing one complete all as specified and directed.
15S&F in replacement of light grade down rod for ceiling fan size 60 cm length with connected nut bolt washe complete all as specified and directed.
16S&F Anti-Suicide fan rod for the following fuatures Automatic Safety Release, Safe Landing Mechanism,prevention of fan impact, Easy Removal of Restraints and Electrical safety complete all as specified and directed..
17S&F louver shutter iron body of superior quality for exhaust fan any size any type complete all as specified and directed.
18S&F in replacement of electronic stepped fan regulator 230 volts suitable for ceiling fan of size 1200mm/1400mm sweep complete all as specified and directed.
19Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep.including remote control system with cell Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor ( BLDC) all including connection with three core 1.5 sqmm PVC insulated but unsheathed FRLS cable with multistranded copper conductors from celing rose to fan complete all as specified and directed.
20M&L for taking down wall mounted fan for repair of any make/model of sweep upto 450 mm by removing burnt / heated winding and rewinding with super enamelled copper wire of suitable size including providing insulation material, varnishing and provision of cotton tape, re-assembling and testing including replacement of spring washer, bearing, bush, and two core flexible wire of size 1.5 sq mm with copper conductor of suitable upto 1.50 m length & refixing the same after repair complete all as specified and directed.
21S&F Exhaust Fan blade made out of metal , sweep size 250-450 mm duly screwed with spring washers of make as per existing one including taking down existing complete all as specified and directed.
22AIR CONDITIONERTaking down carefully window / Split Air Conditoner unit capacity of 1.5/2.0 Ton from the fixtures, disconnecting power cables, drain pipes & accessories and cleaning by removing dust with suitable pressure system, cleaning of air filters, tightening of loose wire, nuts, bolts, washers, servicing of condenser motor & blower motor by greasing including minor repairs, required welding or brazing to prevent leakages of gas, replacement of worn out rubber bushes of condensor motor, setting of grill alignment & knobs, Checking for any leakages, provision of tharmocol,Brass nut, flair nuts, backelite connector and refixing the AC unit and connecting up complete after carrying out necessary repair/servicing to the entire satisfaction of the engineer in charge. Note : Spare parts will be measured and paid under relevent items of schedule.
23S&F wall split units electrically operated indoor and outdoor air conditioner complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum BEE 5 star rated with invertor technology 1.5 ton of Make; Voltas,Panasonic,Hitachi, Blue star all as specified and directed. The unit shall including an indoor air distribution module and an outdoor heat exchange asssembly interconnected through insulated piping and suitable electrical connections complete all as specified and directed.
24M& L for recharging R-22/R-32/R-410 gas as required or as per manufacurer recommendations in air conditioners split or window type 1.5 Ton & 2 Ton capacity any make or model including testing and prevention of leakage for satisfactory performance complete, all as specified. Please Enable Macros to View BoQ information
25M& L for recharging R-22/R-32/R-410 gas as required or as per manufacurer recommendations in air conditioners split or window type 1.5 Ton & 2 Ton capacity any make or model including testing and prevention of leakage for satisfactory performance complete, all as specified. Please Enable Macros to View BoQ information

Other Detail

Information Source https://defproc.gov.in/nicgep/app
Download FileName File Description File Size
Download 5ab655c1-356a-42a2-8c08-dc5405a8978c.html Tender Documents 0 KB
Download BOQ_855953.xls Tender Documents 0 KB
Download Tender08202627.pdf Tender Documents 0 KB
Download Tendernotice_1 (1).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.