Indian Tenders

Tender Notice

TDR 55365154
Tendering Authority Rajcomp Info Services Limited
Tender No F3.3(572)/RISL/Pur/2026/213
Tender ID 2026_RISL_556685_1
Tender Brief Tender For Request For Proposal (Rfp) Interior Works Of The Premises In Jeevan Nidhi-I Building, Jaipur
City Jaipur
State Rajasthan
Document Fees INR 7500 /-
EMD INR 250000.0 /-
Tender Value INR 1.25 Crore /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Request For Proposal (Rfp) Interior Works Of The Premises In Jeevan Nidhi-I Building, Jaipur

Key Dates

Publish Date 06-05-2026
Last Date of Bid Submission 12-05-2026
Tender Opening Date 12-05-2026

Contact Information

Company Name Rajcomp Info Services Limited
Contact Person MD, RISL
Address First Floor, Yojana Bhawan, Tilak Marg c Scheme Jaipur

BOQ Items

Name of Work:- Request for Proposal (RFP) Interior Works of the premises in Jeevan Nidhi-I Building, Jaipur
Sl. No. Item Description
1CIVIL AND ALLIED FINISHING WORKS
2Demolishing/dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material .All lead and lift from site up to 25 km outside the site (dispose of the material) at safe place. Scope as per civil demolishion works drawing attacched inlcuding walls, plaster, floor/ wall tiling/ skirting, toilet fittings & fixtures, door windows etc. ( The drawing for dismantling is shown. the contractor should see site for quoting this item before bid )
3Providing and laying Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. 75mm thick with 20mm thick nominal size aggregate.
4Providing & fixing 300mmx300mm & 6mm thick anti skid ceramic tile flooring of approved size and shade in 12mm thick CM 1:3, with cement slurry, pointing of tiles with Tile mate or equivalent to match the colour of the tiles, Proper slope to be maintained, curing ,oxalic acid wash etc., complete. no extra charge payable for cutting borders, cutting for drain holes etc.)
5Providing and fixing Wall tiles of 300mmx450mm with vitrified tile on a backing plaster of CM 1:4 including slurry,12 mm thick including pointing with matching Cement grout , including acid washing, complete as per specifications and as per the sizes and pattern given by engineers. Rate to include cost of all materials and labour required for the finished job.
6Providing and fixing Granite stone slab mirror polished and machine edge cut in pantry Counters, Floors etc. laid on 20mm thick kota stone/wooden pantry top with means of approved chemical adhesive including base preparation on Kota stone/Wood and silicon sealing of edges. Granite of approved shade and specification not less than 16mm thick of base rate up to Rs. 200/sqft.
7Finishing of existing walls with new coat of putty in line and level by scrapping of old paint, making walls rough and adding two or more coats of putty as base surface for final finish as per design
8Plumbing works for toilets/ pantry inlcuding Providing and fixing of W.C. pan (any type including WC cover,SS jali, health Facuets,cistern 10 liters etc all accessories), Urinals and wash hand basin/ SS sinks for pantry (double bowl with drain board) including pillar cock,angle valve,connection pipe,outlet pipe,ss jali of all sizes with care including all necessary fittings P or S trap. Cost to include if any repair of pipe work or new pipe to be installed in all manners. Toilets to be handed over in working conditions (men's toilet - 2 nos & Ladies toilet - 2 nos & officer's toilet -2 nos )
9Providing and fixing of single bowl 304grade matt SS for Pantry area under counter sink with drain board, floor trap, long neck pillar cock counter mounted, PVC connection with angle valves, provision for R.O., geyser etc complete with all sanitary and Cp fittings as per sanitary & plumbing drawings attached complete with Fresh water supply lines/ Waste water pipe connection in working order.
10Providing and laying of Vinyl Flooring of approved make and shade, confirming to relevant IS standards, of thickness 2 mm / 3 mm (as specified), in approved pattern and design, laid over properly prepared sub-base including cleaning, leveling with self-leveling compound wherever required. Fixing shall be done using recommended adhesive, including cutting, fitting, jointing, and finishing complete in all respects as per manufacturer’s specifications and Engineer-in-charge directions.
11Providing and fixing False Ceiling as per India Gypsum Specifications made of standard G.I. Sections and 12.5mm thick gyp board sheets inclusive of all hangers, edge members and other clips complete, with sheets fixed with proper screws by power drills and joints duly finished ensuring level in line and plumb to take final paint. All inclusive of detailed cut-outs for light fixtures, AC grilles. All Vertical drops will be measured extra as per actuals.The cost to be inclusive of surface preparation as per INDIA GUPSUM STANDARDS ( MODE OF MEASUREMENT L x B) .
12Providing and applying of acrylic emulsion paint finish to walls, blocked partitions, and plasterboard ceiling surfaces of approved shade, texture. Existing wall and ceiling surfaces to be prepared by scraping away any loose particles, dust, etc by washing and scrubbing and 1 coat of primer approved by manufacturer applied. Surfaces are then sandpapered to achieve a smooth finish and two or more coats of paint are applied as per manufacturer's specification.
13Providing and applying Painting (two or more coats) on door and windows with synthetic enamel/Enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. Colour to be taken approval from engineer-in-charge
14Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @0.253 kg//sqm .This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for 4 hours followed by water curing for 48 hours. The rates includes preparation of surface treatment & sealing of all joints ,corners, junction with polymer mixed slurry.
15PARTITIONS AND FIXED FURNITURE WORKS
16Providing and fixing Full glass wall partitions made of 12mm Toughened glass with frame-less structure. Proper structure shall be made to ensure the fixing of glass from RCC slab above false ceiling and flooring. Straight and vertical structural members shall not be visible. custom printed Privacy film shall be applied on the glass as per design selected. All joints, edges and gaps to be sealed neatly with clear silcon not more than 4-5mm wide. NOTE: - The nature of installation should be replaceable, expandable and flexible to cater the future.
17Providing & fixing Single leaf/ double leaf Flush shutter door with door frame 150mm*75mm and - 32mm th. door finished with laminate on both sides and glazed panel in between. Shutter to have 35mm wide and 12mm thick lipping beading allround finished with enamel paint of approved brand, colour and shade., Cost to include necessary hardwares door closer, hinges, handle lock etc., complete. Size 3.5'x7'.Details to be followed as per engineer in charge.
18Providing and fixing CNC cut letters ranging in size from 200mm to 375mm, in 12mm MDF fixed to walls as per design and location to form wall quotes/ panels. Finished in duco paint with wall suspending hatrdware prefixed at the rear. Front Area to be measured for panel size.
19Providing and fixing Wall cladding with custom printed venyl sheet pasted over 3mm Sunboard and laminated with matt finish protective clear film. To be mounted to wall with the help of silicon such that it appears snug fit and leaving no gaps on the side. Incase the maximum size exceeds the available size of venyl sheet, the print to be created in such a manner so that the joint is overlapped and not visible clearly. Rate to include purchase/ procurement of High resolution image from shutterstock or similar website.
20Providing and fixing Beveled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers.it is to be installed as per size given by engineer in charge.
21LOOSE FURNITURE AND WORKSTATIONS
22Supply & installation workstations of size 900(L) X 600(W) X 750(H) , Base System (Sole Type Workstation) having 25 mm thick pre-laminated particle board top with edge banding and 120mm x 120mm anodized grommet, including 25 mm thick magnetic fabric main spine (750mm wide for sharing / 860mm wide for non-sharing with aluminium section), complete with aluminium powder coated sole base, die-cast connectors, MS powder coated legs and beams, MS powder coated metal modesty panels (450mm ht with 300mm floor clearance at required locations), and MS powder coated wire management system with cable tray, switch plate provision and vertical cable management, all complete as per approved design, drawing and direction of Engineer-in-Charge.
23Supply, fabrication, installation, testing and fixing of modular workstation partitions made of MDF board / soft board (pin-up board) with required framing, finished with fabric / laminate as approved, complete in all respects as per drawings, specifications and direction of Engineer-in-Charge.
24Supply & installation Modular storage works for pantry and store areas as per design. Base structure for carcass and shutters/ drawers made in Boiling water proof & termite proof plywood and blockboard and finished with 1mm laminate. Rate to include internal shelves/ partitions/ 304 grade SS mongeries/ Hardware like drawer channels/ Autoclose hinges complete as per design drawing attached in RFP. Front facia to be measured
25Supply & installation of Manual Roller blinds having Aluminum Roller tube along with fabric pasted on it with glue having control unit for manual operations and bottom bar Aluminum powder coated for weight purpose, including fabric, fitting & accessories of approved make & colour etc. complete.
26Providing and fixing of fabric based wallpaper of approved shade and brand not less than 220 GSM on specified areas wherever mentioned by means of suitable adhesive. Air gaps and wrinkles to be taken care of with proper alignment. Cost to include necessary scaffolding if required. Mode of measurement LengthxBreadth (application area).
27Providing and fixing of Logo in reception made up of laser cut 2+2mm acrylic sheet size 1mtr by 1mtr .details given by engineer in charge. Cost to include graphical drafting on suitable software supported by CNC machine.
28Providing and fixing Name plate for individual cabin and rest of the area. Signage's are made up of laser cut acrylic sheet of 2mm thicksheet with laser cut method for impression.Approx. Dimensions: 300 mm X 170 mm X 2 mm.Design and detailing provided by as per engineer in charge. Cost to include graphical drafting on suitable software supported by CNC machine.
29SITC of Chair (Workstation Chair)Medium Back, Mesh Back, Silver Epoxy Backbone, Synchronized Mechanism,Adjustable Armrest, Gaslift for Seat height adjustment, Standard 5-prong nylon Base, Seat - Fabric and mesh backrest, Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
30SITC of Industrial Grade Water Cooler of approved make, having cooling capacity not less than 120 LPH, stainless steel body, heavy-duty compressor, eco-friendly refrigerant, air-cooled condenser, automatic temperature control, and storage tank of SS-304, complete with inlet/outlet connections, float valve, drain arrangement, electrical fittings, earthing, and all accessories, including necessary civil works, testing and commissioning, complete as per manufacturer specifications and direction of Engineer-in-Charge.
31Providing and fixing White Board (1200mm x 900 mm)of approved make, having writing surface of high-quality magnetic ceramic/laminated steel with smooth finish, backed by soft board/MDF for rigidity, aluminium anodized frame with rounded corners, complete with pen tray, wall mounting arrangement with necessary screws, fasteners and accessories, all complete as per approved specifications and direction of Engineer-in-Charge.
32Providing and fixing Notice Board (1800mm x 600mm)of approved make, having soft board surface (fabric/pin-up type) over suitable backing, framed in anodized aluminium section with rounded corners, complete with wall mounting arrangement including screws, fasteners and all accessories, finished in approved colour and shade, all complete as per specifications and direction of Engineer-in-Charge.
33Providing and fixing of hoardings outside the building as per size give by engineer in chargeApprox. Dimensions:1500mm(W) X 900mm(H) with provision of backlight
34Providing labour and materials for repair, refurbishment, and maintenance of existing furniture including chairs, tables, workstations, cabinets, wardrobes, etc., complete as per site requirements.
35Supply, Installation, Testing & Commissioning of RO Water Purifier System of capacity 50 LPH, including pre-filtration unit (sediment & carbon filters), RO membrane, high-pressure pump, UV/UF post-treatment, food-grade storage tank, TDS controller, and all allied components, complete with piping, valves, fittings, electrical connections, drain arrangement, mounting structure, etc., as required for proper functioning
36Architechtural and MEP cunsultant charges for submission of working drawings as per BOQ of CVIL, MEP and conceptual drawings enclosed in RFP.
37Providing and fixing double scaffolding system on the exterior side, upto five story made with 4\\" wooden member 1.5 m c/c horizontal and vertical direction joining with rassi, clamps, challies. The scaffolding system shall be stiffened with bracing, runner, connection of building if necessary with all essential safty features for the workmen etc complete as per direction of EI.The lavation area of the scaffolding shall be measured for payment. The payment will be made once irrespective of duration of scaffolding.
38Providing and carrying out machine polishing of existing marble/Granite flooring, including thorough cleaning of surface, removal of stains, scratches and unevenness, grinding with suitable grades of carborundum/diamond pads, application of marble polish/oxalic acid as required, buffing to obtain smooth, uniform and glossy finish, complete in all respects, including all materials, labour, tools, consumables and disposal of waste, as directed by Engineer-in-Charge.
39Supply and placing of artificial indoor plants consisting of high-quality UV-resistant synthetic leaves with natural finish, fixed in decorative FRP/ceramic planter filled with thermocol/pebbles/artificial soil for proper stability, complete as per approved size, shape and location including all leads, lifts, handling and placement as directed by Engineer-in-Charge.Size (3' to 4')
40upply and placing of approved variety indoor live plants (such as Areca Palm, Snake Plant, Money Plant, etc.) of healthy growth, minimum height 600 mm to 1200 mm, planted in suitable size decorative pot made of ceramic/FRP/plastic of approved colour and finish, filled with good quality soil, manure and base layer (pebbles/aggregate) for proper drainage, including watering, initial maintenance for 7 days, handling, transportation and placing at designated locations as directed by Engineer-in-Charge, complete in all respects.
41WIRING (supplying and fixing following items)
42Wiring of light point/ fan point/ exhaust fan point/ call bell point as per specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it's all accessories( J.B. , Bends etc.) , round tiles,18 SWG Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / lamp Holder/ 3 pin connector , screws etc, making connections,all as per pre approved by Engineer in charge, testing etc. complete as required as per recommended makes of RFP.
43Short point (up to 3 mtr.)
44Medium point (up to 6 mtr.)
45Long point (up to 10 mtr..)
46Wiring of 3 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) of approved make in surface / recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's accessories, 18 SWG 175 mm x 100 mm x 60 mm M.S. box with earth terminal, 6 A switch, 6 A socket, 3.0 mm thick ISI marked phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required.
47On board
48Supplying and fixing of power plug point with Modular accessories as per specification for electrical Works, on hot dipped galvanized modular box of 18 SWG with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 3/5 pin 16 amp. socket outlet (IS:1293) , making connection , testing , etc. as required. All as per pre approved by Engineer in charge. as per recommended makes of RFP.
49P & F 3 Way, 4 Conductors with current rating 16 Amp. Connector
50S&F following sizes of ISI marked DLP U-PVC mini trunking systems along with accessories like end cap, internal angle, external angle ,Flat angle, Flat junction etc. on surface with screws, expansion fasteners as required. (make: legrand)
51Mini-Trunking -32 x 12 mm
52Finishing Accessories
53End cap right or left
54Changeable internal-external angle from 600 to 1200
55Changeable flat angle from 850 to 950
56Flat junction
57White 32 x 10/12.5 cover joint
58Supply, Installation, Testing and Commissioning of Flush mounted Pop-Up Box equipped with following items alongwith installation kits for table top. (i) 2 Nos. 6/16 Amp Socket(ii) Two LAN outlets(iii) 1 Nos. RJ-45 connector(iv) 1 Nos. HDMI outlets.Boxes should be in slim design for perfect integration into the furniture . (Make : Legrand)
59S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit as per specification for electrical Works along with its accessories (IS: 3419 ) as required in recess including cutting the wall, covering conduit and making good the same as required. All relative and latest acceptance tests reports by any NABL accredited lab for the conduit shall be submitted before execution & All as per pre approved by Engineer in charge .as per recommended makes of RFP.
6020 mm
6125 mm
6232 mm
63Supply and installation of fabricated 14 SWG G.I race ways for drawing wires for Raw power, UPS power and communication. The race ways shall be complete with base and cover, junction boxes as required, extension pieces, couplers, end plates, earthing including mechanically cutting chases in floor/ wall etc & making the same good. The race way shall be surface / Concealed type to brick wall / flooring with necessary fixing accessories. All the raceway will have required compartments and all complete as per drawings, specifications, relevant standards, and direction of Engineer in charge.as per recommended makes of RFP.
64Supply, Installation testing and commissioning of GI floor raceway of Height of 1.6 mm thickness with Including PCC cutting , Fixing bracket,coupler,Riser & accessories of civil works if required complete as required . Make:Legrand,MK
65100X38mm (Single Compartment )
6660X38mm (Single Compartment )
67Supply, Installation testing and commissioning of GI junction box it should be positioned directly on the slab to providesaccess to cables at the intersection of trunkings or changes ofdirection. The junction box allows deviation of power and data cables.Screed height should be between 50 to 70 mm. Junction boxes aresupplied with a base with flyovers and a lid. A disposable coverprotection is available as an option. Side plates are pierced to suitRaceways.
68Supply, Installation testing and commissioning of Height adjustable junction box 50 - 70 mm 150 x 150 x 50 - 70 mm GI Floor junction boxwith Metal cover Complete in all respect as required
69Supply, Installation testing and commissioning of Height adjustable junction box 50 - 70 mm 100 x 100 x 50 - 70 mm GI Floor junction boxwith Metal cover Complete in all respect as required
70Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. as per recommended makes of RFP.
713x 1.5 sq.mm
722 x 2.5 sq. mm. + 1x1.5sqmm
732 x 4.0 sq. mm. + 1 x 2.5 sq. mm.
742 x 6.0 sq. mm. + 1 x 2.5 sq. mm.
754 x 6.0 sq. mm. + 1 x 4.0 sq. mm. (DB supply)
764 x 10.0 sq. mm. + 1 x 6.0 sq. mm. (DB supply)
774 x 16.0 sq. mm. + 1 x 6.0 sq. mm.
78DISTRIBUTION BOARDS
79P&F Recessed/ Surface mounting heavy duty horizontal type prewired sheet steel Distribution board phophatised / powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, loose wire box, terminal block , duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks conforming to IS:13032 & IS:8623 including making internal DB terminations with copper lugs , testing etc. as required.
80Double door (Three phase)
816 Way
82Double door (Three phase) Per phase isolation
832+8 Way
842+12 Way
85P & F Recessed / Surface mounting heavy duty horizontal type 16 swg sheet steel cable end box phophatised / powder painted complete with cover plate, nut bolt, to be fixed at top / bottom of the DB to keep extra cable in the end box etc as required to cover the entire lenght of distribution board as mentioned in the above items.
86Suitable for TPN DB
87Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work as per recommended makes of RFP.
88Single pole MCB
896 A to 32 A rating
90Double pole MCB
916 A to 32 A rating
92Triple pole MCB
9340 A- 63 A rating
94Four pole MCB
9540 A rating
9663 A rating
97Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) as per specification for electrical Works with ISI marked (IS:12640-1) / conforming to IEC 61008 -1 , rated conditional s/c current of 10 KA, truly current operated and shall operate on CBCT mechanisum, provision for pad lock, min. operation 10,000 upto 63 A rating and 5000 for 100 A rating, minimum phase termination capacity of 50 sq.mm. rigid wire , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work as per recommended makes of RFP.
98Two pole 100/300mA sensitivity
9940 A rating
100Four pole 100/300 mA sensitivity
10140 A rating
10263 A rating
103P&F recessed/ surface mounting heavy duty Vertical type 16 SWG sheet steel Distribution board with provision of incomer suitable for MCCB and SP / TP MCB as outgoing , phophatised ,powder painted complete with insulated suitable rating copper bus bar , neutral link, earth link and din bar, masking sheet & conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as required.
104Double door with provision ,supply and fixing of Incomer MCCB 100 A Rating
1056 Way
106Providing & Fixing of following modular accessories as per specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. as per recommended makes of RFP.
107Blanking plate
108Providing & Fixing of following size mounting grid plates with cover plates as per specification for electrical Works, made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work as per recommended makes of RFP.
1091/2 Module
1103 Module
1118 Module
112Providing & Fixing of following size hot dip galvanized M.S. box of 18 SWG as per specification for electrical Works, with earthing terminal in recess/ surface suitable for modular accessories as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work as per recommended makes of RFP.
1131-2 Module
1143 Module
1158 Module
116Providing & Fixing of ISO certified company made vergin material PVC trunking system as per specification for electrical Works, with double lock feature for cable management including finishing accessories like corners, tee, adjustable angles, junction etc. as required . The trunking system shall have adaptable system for modular type RJ 45 data socket/ wiring accessories/ power sockets and shall be covered with peal off plastic cover. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work as per recommended makes of RFP.
11780mm x 50mm
118LED Lights and Fixtures
119Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. All as per pre approved by engineer in charge .As per recommended makes of RFP
12024 -32 W LED light fixture 2'x2' with acrylic / prismatic front cover.
121Providing & Fixing of IP40 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Back lit SMD Mid Power LED Downlight with die-cast aluminum housing & Heat Sink for heat dissipation with UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% and in compliance to IEC standards. System Lumen efficacy of ≥ 120 lm / watt, THD < 10 % ,p.f.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. All as per pre approved by engineer in charge .As per recommended makes of RFP.
122Recessed Mounting
123LED Downlight 18/20W
124EARTHINGS
125SITC of chemical Gel earthing system of Dual Pipe Technology made of with \\"B\\" Class G I Pipe as per IS 1239 ( part-1):2004 of Medium duty of following sizes as per points mentioned (a), (b), [c), (d), (e) below :- (a) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 35- 40 KA for withstanding 1 second . (b) To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts(c)Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm.(d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.(e) All as per pre approved by Engineer in charge as per recommended makes of RFP
126With Pipe in Pipe Technology (Outer pipe dia. / Inner pipe dia. ) Minimum 100 mm dia borewell
127GI pipe 3000 mm long, 80 / 50 mm, Terminal 50 mm x 6 mm GI Strip
128S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess on SMC insulator including riveting, soldering, saddles, making connection etc. as required.
1298 SWG Cu wire
13025mm x 3mm copper strip
13132mm x 6mm GI strip
132CABLING WORK
133P/Laying P.V.C. insulated & P.V.C. sheathed armoured cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I on cable tray, including cable termination, cable luges, cable gland, making connection, testing etc. as per specification, drawing & recommended make.
1344 core 10 sqmm
1354 core 16 sqmm
1363.5 core 35 sqmm
1373.5 core 50 sqmm
138Supply, Fabricating & installing following sizes of perforated GI cable trays including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with M.S. suspenders and including painting
139150mm x 50mm x 1.6mm
140300mm x 50mm x 1.6mm
141Providing & Fixing of heavy duty, copper wound , Double ball bearing and with metal sturdy mesh guard; Aluminium alloy one piece blade wall mounting oscillating type air circulator as per specification for electrical Works, conforming to IS:2997, including fixing with anchor bolts, regulator making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work as per recommended makes of RFP.
142450 mm sweep With wall Mounting and three speed regulator
143Providing & Fixing of Heavy duty capacitor start, copper woind Double ball bearing 900/1400 RPM single phase Exhaust fan as per specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge. .As per recommended makes of RFP
144300 mm sweep(900/1400 RPM)
145MEDIUM VOLTAGE PANELS
146First Floor Panel
147Supply, installation, testing & commissioning of cubicle type totally enclosed free standing dust & vermin proof L T metering panel made out of 2.0 mm thick and partition made out of 1.6 mm MS sheet steel, suitable for 3 phase , 4 wire , 415 V , 50 Hz , AC supply complete with incoming MCCB & outgoing MCB/ MCCB, All the MCCB should be with Rotary handle, Dual source electronic energy meter, Electrolytic grade Al busbar of required capacity, indication lamp etc complete as per drawing & enclosed specifications recommended makes. INCOMER : 160 Amp, FP,25 KA, MCCB having Thermal Magnetic release with short circuit and adjustable overload (0.7 to 1In ) protection - 1 no3P+N Type2 SPD with inbuilt health indicator, response time < 25 ns, Imax (8/20 µs) 8 KA, Voltage Protection Level 1.2 KV, shall be used at the incomer side of the panel with 32 Amp FP C curve MCB. - 1 noBUSBAR: 300 Amp, FP, Electrolytic grade Al busbar for main MCB outing & feeders distribution, The Bus Bar section should be covered with withdrawable Acrylic sheet for protection.OUTGOING : 100 Amp, TP, 25 KA, MCCB with neutral link, having Thermal Magnetic release with adjustable overload , & short circuit protection. ON/OFF TRIP, indication lamp - 2 nos40 Amp, FP, 10KA, MCB, - 3 no63 Amp, FP, 10KA, MCB, - 2 noFOR SPARE63 Amp, FP, 10KA, MCB, - 1 no40 Amp, FP, 10KA, MCB, - 1 noMETERING SECTION DIGITAL LED Energy meter (32 samples/cycle) of rating with 3 nos 200/5A class 1 as per IEC 62053-21, CTs as per SLD, The Digital meter shall measure V /I /F /PF /KW / KVA /KVAR / KWH / KVAH / KVARH / MD / %THD parameters. The energy meter should have communication modbus RS 485 port & required hardware & software for communication, duly protected by 2A MCB - 1 nosLED type RYB indication lamp duly protected by 2A MCB– 3 Nos.
148Terrace Floor AC Outdoor Panel
149Supply, installation, testing & commissioning of outdoor cubicle type totally enclosed free standing double door type dust & vermin proof IP65 Kiosk Panel for outdoor application made out of 2.0 mm thick and partition made out of 1.6 mm MS sheet steel, suitable for 3 phase , 4 wire , 415 V , 50 Hz , AC supply complete with incoming ACB / MCCB / SFU & outgoing MCB / MCCB / SFU , All the MCCB should be with Rotary handle, Four Pole Electrolytic grade Al busbar of required capacity, indication lamp etc complete as per drawing, enclosed specifications and recommended makes. INCOMER100 Amp, FP,25 KA, MCCB having Thermal Magnetic release with short circuit and adjustable overload (0.7 to 1In ) protection - 1 noBUSBAR200 Amp, FP, Electrolytic grade Al busbar for main MCB outing & feeders distribution, The Bus Bar section should be covered with withdrawable Acrylic sheet for protection. OUTGOING40 Amp, FP, 10KA, MCB, - 1 no63 Amp, FP, 10KA, MCB, - 3 noFOR SPARE63 Amp, FP, 10KA, MCB, - 1 no40 Amp, FP, 10KA, MCB, - 1 noAll the accessories should be mounted on 6 mm thick bakelite sheet - 1 setMETERING SECTION FOR INCOMERDIGITAL LED Energy meter (32 samples/cycle) of rating with 3nos 150/5A class 1 as per IEC 62053-21, CTs as per SLD, The Digital meter shall measure V /I /F /PF /KW / KVA /KVAR / KWH / KVAH / KVARH / MD / %THD parameters. The energy meter should have communication modbus RS 485 port & required hardware & software for communication, duly protected by 2A MCB - 1 nosLED type RYB indication lamp duly protected by 2A MCB– 3 Nos.
150FIRST FLOOR 40 KVAR APFC PANEL
151SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as per specification for electrical Works, made out of CRCA sheet . Other parameters required as per point (a) ,(b), (c) below:-(a)Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure(b)panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware, separate detachable gland plate M.S. base channel (min75mm) , hinged door with locking arrangement for equipment/switchgear [c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 125 amp ) and by solid bus bar (>125 amp ) . All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. All as per drawing pre approved by Engineer in charge. as per recommended makes of RFP .
152Including supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar 6012 grade as per specification for electrical Works, by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge and as per recommended makes of RFP .
153Including Providing & Fixing of BIS approved 3 Nos. Current Transformer of rating C T Class 1, Ratio upto 200/5, Burden 5 VA as per specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge
154Including Providing & Fixing of ISO certified company made UL listed , IP 65 110/220 V, unibody LED Indicating lamp(Red/yellow/Green colour) IEC 60947 , CSA 22.2 with integral circuit, IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge and as per recommended makes of RFP
155Including Providing & Fixing of IP 51 Multi function meter as per specification for electrical Works, ISI marked (IS 16444)/ Confirming to IEC 61557 & IEC 62052 with LCD/ LED 3/4 line display capable of measuring electrical parameters like V, I, F, PF, KW, Kva, Kvar, Kwh, Kvah, Kvarh display with 1A/5A CT input for LV/ HV network, with /without RS 485 communication port etc. All as per pre approved by Engineer in charge and as per recommended makes of RFP
156SITC of IP 40 quick make and quick break 4 pole current limiting Moulded case circuit breaker (MCCB) of rating 100 Amp (Incomer) , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings as per specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders, etc. as required. as per recommended makes of RFP .
157The details of capacitor/capacitor duty contractor/ APFC Relay/Indication lamp/ventilating fans/ selector switches /selector switches/ MCB/ control wiring is as follows
158Capacitor Bank – 40 KVAr (1-2-2-5-10-10-10)Capacitor steps: (a) First steps - 1 KVAr(b) Next two - 2 KVAr(c) Next one - 5 KVAr(d) Next three - 10 KVAr
159SWITCHING3 P, 440 V capacitor switching contactor duty AC - 6b of required rating with suitable rating MCB as per SLD(a) 1 KVAr with 6 Amp D curve TP MCB(b) 2 KVAr with 10 Amp D curve TP MCB(c) 5 KVAr with 16 Amp D curve TP MCB(d) 10 KVAr with 32 Amp D curve TP MCB
1608 stage Microprocessor based APFC relay of sensitivity less than 50 ma - 1Nos
161LED type ON indication lamp –14 Nos
162Ventilation Fans with thermostat & On/Off selector switch – 2Nos
163Auto /Manual /off Selector Switch (3 position) – 7 Nos
164The CT sensing of the APFC relay shall be from the incomer side of contacotr (JVVNL supply).All control wiring from Bus bar to MCB, capacitor duty Contactor & Capacitor bank will be of required Ratings PVC insulated flexible copper wire.
16530 kVAR APFC Panel For Ground Floor
166SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as per specification for electrical Works, made out of CRCA sheet . Other parameters required as per point (a) ,(b), (c) below:-(a)Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure(b)panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware, separate detachable gland plate M.S. base channel (min75mm) , hinged door with locking arrangement for equipment/switchgear [c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 125 amp ) and by solid bus bar (>125 amp ) . All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. All as per drawing pre approved by Engineer in charge. as per recommended makes of RFP .
167Including supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar 6012 grade as per specification for electrical Works, by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge and as per recommended makes of RFP .
168Including Providing & Fixing of BIS approved 3 Nos. Current Transformer of rating C T Class 1, Ratio upto 200/5, Burden 5 VA as per specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge
169Including Providing & Fixing of ISO certified company made UL listed , IP 65 110/220 V, unibody LED Indicating lamp(Red/yellow/Green colour) IEC 60947 , CSA 22.2 with integral circuit, IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge and as per recommended makes of RFP
170Including Providing & Fixing of IP 51 Multi function meter as per specification for electrical Works, ISI marked (IS 16444)/ Confirming to IEC 61557 & IEC 62052 with LCD/ LED 3/4 line display capable of measuring electrical parameters like V, I, F, PF, KW, Kva, Kvar, Kwh, Kvah, Kvarh display with 1A/5A CT input for LV/ HV network, with /without RS 485 communication port etc. All as per pre approved by Engineer in charge and as per recommended makes of RFP
171SITC OF 63 A FP MCB FOR INCOMER
172The details of capacitor/capacitor duty contractor/ APFC Relay/Indication lamp/ventilating fans/ selector switches /selector switches/ MCB/ control wiring is as follows
173Capacitor Bank – 30 KVAr (1-2-2-5-10-10)Capacitor steps: (a) First steps - 1 KVAr(b) Next two - 2 KVAr(c) Next one - 5 KVAr(d) Next two - 10 KVAr
174SWITCHING3 P, 440 V capacitor switching contactor duty AC - 6b of required rating with suitable rating MCB as per SLD(a) 1 KVAr with 6 Amp D curve TP MCB(b) 2 KVAr with 10 Amp D curve TP MCB(c) 5 KVAr with 16 Amp D curve TP MCB(d) 10 KVAr with 32 Amp D curve TP MCB
1758 stage Microprocessor based APFC relay of sensitivity less than 50 ma - 1Nos
176LED type ON indication lamp –12 Nos
177Ventilation Fans with thermostat & On/Off selector switch – 2Nos
178Auto /Manual /off Selector Switch (3 position) – 6 Nos
179The CT sensing of the APFC relay shall be from the incomer side of contacotr (JVVNL supply).All control wiring from Bus bar to MCB, capacitor duty Contactor & Capacitor bank will be of required Ratings PVC insulated flexible copper wire.
18030 kVAR APFC Panel
181Supply, Installation, Testing and Commissioning (SITC) of VRLA/SMF batteries suitable for 20 KVA UPS system to provide minimum 15 minutes backup at full load, complete with interconnecting cables, battery terminals, connectors, battery rack/stand, and all necessary accessories as per technical specifications.
182LAN Services:
183DATA & TELEPHON WORK
184Supply , Installation, Testing and Comissioning of Wall mounted Communication rack with glass doors, handles ,lock , Top and Bottom Cable entries, Supports for mounting rack on wall , Cable managers, one Fan, Equipment mounting hardware, power supply box for supplying power to switches, fans etc along with earth continuity kit, Mcb, indicator, moulded power supply cable
18512 U(44 mm ) wall mounted
186Supply, Installation, & Testing of 19\\" 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, multimode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirement complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work as per recommended makes of RFP.
187Multi Mode LIU 6 Ports
188Supply, Installation, & Testing of Indoor duplex Multimode patch cord (50/125 µm made of glass fiber optic with LSZH jacket, Multimode G652.D Mounted on both sides with ST/E-2000/SC/LC/MT-RJ/PC type Duplex connectors in acc. with IEC 61754-20 as per latest ammendments of TIA/EIA 569B.3, as per requirements complete in all respect. All as per pre approved by Engineer in charge as per recommended makes of RFP.
1893 Mtr
190Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic, should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc. with IEC 61754-20, as per latest ammendments of TIA/EIA 569 Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work as per recommended makes of RFP.
191Supply, Drawing and Testing, of stranded Multi mode (50/125 µm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC 11801:2011/ IEC 60794-1-2 E1, E3,E11, F1/ EN 50173-1/ EN 187 000/ IEC 60974-2, 2-20, 2-21/ ITU G.652D, construction of LSZH outer sheath cable, cable should be used for LAN and WAN back bones, . With its LSZH sheathing these cables should be ideal for indoor/outdoor installations in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect. All as per pre approved by Engineer in charge. as per recommended makes of RFP. (10 -G Cable)
1926 core 10G glass optic fiber Cable)
193SITC of FM Connector (specifically designed for tool less connection for CAT6 FTP / Outdoor cabling system, can be usable for multiple times) required for both end connectivity to take care for Data connectivity as well as Power for the cameras, The FM connector shall be used for earth connectivity at both end
194Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors as per ANSI/TIA/EIA 568 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568, minimum requirement for 1G BASE-T/ 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, Minimum 750 to 1000 mating cycles in plug contacts for long durability complete in all respect. All as per pre approved by Engineer in charge. as per recommended makes of RFP.
195Cat 6, UTP (Un-sheilded Twisted Pair) Patch Cord
1961 Mtr
1972 Mtr
198SITC of 42U Closed Network Rack with min 60% hexagonal perforation Front & Rear Spilt Door., castor wheels, 2 Equipment Shelf, 15 Amp, AC power supply Vertical with 16 sockets- 2 nos, 4 fans at top Mounted, with atleast 15 1U cable managerseach rack, earthing kit and Mounting Accessories.
199Supply, Installation, Testing and Comissioning of Rack mounted 19\\" 1U, 24 Port Unloaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panels (without I.O.) with Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel, . There should be a provision for each port/jack on the panel and reusable removable on field from the panel complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work as per recommended makes of RFP.
200SITC of Intelligent Ethernet POE Switches providing 24x 10/100/1000 Fast Ethernet POE ports- 370W or better and 4 dual purpose uplink (provision for Copper / Fiber Giga connectivity) with provision of minimum Stacking of 06 Switches with related LAN Base Software . For additional technical parameters of products/ work as per recommended makes of RFP.
201Supply, Installation, Testing and Comissioning of Rack mounted , 48 x 10/100/1000 Ethernet ports Gigabit Switch with 4 mini Gigabit Interface Converter slots(shared with 4 Ethernet ports) for Gigabit Ethernet expansion , Switching capacity 96 Gbps nonblocking , . As per recommended makes of RFP.
202Supply, Installation, Testing and Comissioning of 1G SFP (small form-factor pluggable) transceivers as per recommended makes of RFP.
203Supply, Installation, Testing and Comissioning of 10G SFP (small form-factor pluggable) transceivers as per recommended makes of RFP.
204Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work as per recommended makes of RFP.
205Supply and Installation of unsheilded/ sheilded Information outlets made of high impact plastic body with ABS, FR Grade with provision for protection against dust in jack/ FP, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact punch termination on reliable copper tin plated Insulation displacement contact, It complied with ANSI/TIA/EIA 568 standard. In existing modular/MS Boxes along with necessory connections as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work as per recommended makes of RFP.
206Cat 6, Un-sheilded Information Outlet
207Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture , material should be PC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. Dimensions should be 86mm X 86mm as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work as per recommended makes of RFP.
208Single Aperture
209Interactive Display65' with mounting kit Approved Makes:- , samsung, Sony .For additional technical parameters of products/ work as per recommended makes of RFP.
210Fire Detection Services:
211Supplying and drawing FRLS PVC insulated & unsheathed flexible copper conductor as per specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228. FRLS PVC insulation which provides better fire retardant properties then normal PVC & also emits Low Smoke in case of fire & use type A insulation PVC, in existing conduit including , all as per pre approved by Engineer in charge,making connections, etc. as required. As per recommended makes of RFP
2122 x 1.5 sq.mm
213SITC Conventional Optical type Smoke Detector with mounting base, LED etc. as required.
214SITC of conventional type Manual call point complete with Glass, hammer and chain etc. as required.
215SITC 6 watt Speaker mounted in M S sheet box with perforated front mesh for PA and Emergency System.
216SITC of wall / floor type following zone (each zone accessing minimum 20 units (detectors/ devices ) Conventional Type 4 zone microprocessor based with LCD display main control panel/ floor panel fabricated from 16 SWG CRCA sheet steel sealed maintenance free (SMF) batteries of min2X7AH of 12 V or as required . All specifications of panel enclosed in RFP . Panel should be installed as per engineer in charge and as per recommended makes of RFP
2174 zone
218Supply & Fixing of ABC Type (MAP 50) type powder Fire Extinguisher (Stored Pressure type) of following capacity duly current and valid BIS certification conforming to IS: 15683:2006, with Dry chemical powder used as extinguishing agent should be Mono Ammonium Phosphate 50% concentration conforming to IS 14609:1999.Serial no. and date of manufacturing should be embossed or printed on the body of the fire extinguisher. All as per pre approved by Engineer in charge.
219Providing, supplying, installation, testing & commissioning of Heavy Duty Projector of approved make, having minimum brightness of 4000–5000 lumens, full HD resolution, suitable for ceiling mounting, with HDMI/VGA connectivity, built-in speaker, complete with ceiling mount kit, necessary power and signal cabling, accessories, alignment, testing & commissioning, all complete as per specifications and direction of Engineer-in-Charge. Make ;- BenQ / Epson / Optoma or equivalent approved
220Providing, supplying, installation, testing & commissioning of 16 Channel Network Video Recorder (NVR) of approved make, supporting minimum 16 IP cameras, H.265/H.264 compression, 4K recording capability, with minimum 8 TB storage (expandable), HDMI/VGA output, USB ports, remote viewing facility, complete with suitable HDD, power supply, necessary mounting, networking accessories, interconnections, configuration, testing & commissioning, all complete as per specifications and direction of Engineer-in-Charge. Make: CP Plus / Dahua / UNV / Honeywell or equivalent approved
221Providing, supplying, installation, testing & commissioning of Internal IP Dome Camera of approved make, having minimum 2 MP (1080p) resolution with progressive scan CMOS sensor, fixed lens (2.8mm/4mm), IR illumination up to 20–30 m for night vision, supporting H.265/H.264 compression, Wide Dynamic Range (WDR), Digital Noise Reduction (DNR), and IP66 protection, complete with PoE support, necessary mounting accessories, junction box, interconnection with Cat6 cable, configuration, testing & commissioning, all complete as per specifications and direction of Engineer-in-Charge.
222SITC of 4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation from 50 to 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle ( to be paid extra) , including making connections etc. as required. OEM shall have submit NABL / CPRI / ERDA/ Intertek accrediated lab type test certificate.
2234 pole MCCB With Thermal Magnetic release
224up to 100 Amp , 25 kA, adjustable O/L & Fixed S/C setting,
225SITC of IP-20 LED Recessed / Surface Mounted, Round / Square backlit & SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS compliance 4.0 KV surge protected Isolated driver, with Short & Open circuit protection input 320VAC-48 hr protection, input 350VAC-2 hr protection), having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt,at CW (5700K to 6500K) , THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
226Minimum lumen output 600 lm (lumen efficacy ≥ 100 lm / watt)
227SITC of IP20, 1'X1' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution.operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
228Minimum lumen output 2880 lm
229Providing services for careful dismantling, shifting, and reinstallation of existing air conditioning units (Split / Window AC) including all accessories, complete as per site requirements. Scope of Work:Dismantling of existing indoor and outdoor AC units without damageSafe recovery of refrigerant gas (if required)Disconnecting electrical connections, drain piping, and copper tubingProper handling, packing, and shifting within site / designated locationReinstallation of AC units at new location including mounting of indoor & outdoor unitsRefixing/laying of copper piping, drain pipe, and electrical wiringVacuuming, gas charging/top-up (if required)Testing, commissioning, and trial run to ensure proper functioningMinor civil works (core cutting, patch repair) if requiredAll tools, tackles, consumables, clamps, sleeves, insulation, etc. included
230Providing Comprehensive / Non-Comprehensive Annual Maintenance Contract (AMC) for Air Conditioning Systems (Split / Window / Cassette / Ductable / VRV/VRF units) for a period of 12 months, complete as per specifications and site requirements. Please Enable Macros to View BoQ information

Other Detail

Information Source https://eproc.rajasthan.gov.in
Download FileName File Description File Size
Download 3fff02ed-c7c8-4094-8760-9173958034bf.html Tender Documents 0 KB
Download BOQ_991109.xls Tender Documents 0 KB
Download RFP.pdf Tender Documents 0 KB
Download Tendernotice_1 (16).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.