Indian Tenders

Tender Notice

TDR 55355364
Tendering Authority Power Development Department
Tender No ED-III /06 of 2026-27, Dated - 05-05-2026
Tender ID 2026_PDD_309392_1
Tender Brief Corrigendum : Tender For Rate Contract For Carrying Out Restoration, Maintenance And Ht-Lt Network Improvement Works For The Year 2026-27 In Respect Of Esd Nawakadal, Esd Pather Masjid & Esd M.R Gunj, Ed-3Rd (Stage Contract).
City Srinagar
State Jammu And Kashmir
Document Fees INR 500 /-
EMD INR 10000.0 /-
Tender Value Refer document
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Rate Contract For Carrying Out Restoration, Maintenance And Ht-Lt Network Improvement Works For The Year 2026-27 In Respect Of Esd Nawakadal, Esd Pather Masjid & Esd M.R Gunj, Ed-3Rd (Stage Contract).

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 07-05-2026 BOQ Correction BOQ 21-05-2026

Key Dates

Publish Date 07-05-2026
Last Date of Bid Submission 21-05-2026

Contact Information

Company Name Power Development Department
Contact Person Executive Engineer, ED-3rd Srinagar
Address Office of Executive Engineer, ED-3rd Srinagar

BOQ Items

Name of Work:- Rate Contract for carrying out Restoration, Maintenance and HT-LT Network improvement Works for the year 2026-27 in respect of ESD Nawakadal, ESD Pather Masjid & ESD M.R Gunj, ED-3rd (Stage Contract).
Sl. No. Item Description
1Supply, Installation, Testing and Commissioning of
211 Mtr ST Pole ST-410 SP56 S.T. poles well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground level with earthing arrangement through bolt welded on pole of 14mm diameter, provided at height of 300mm above & bottom plate 35cm*35cm, 5mm thick fully welded.
39 Mtr ST Pole ST-410, SP-33 S.T. poles well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground level with earthing arrangement through bolt welded on pole of 14mm diameter, provided at height of 300mm above & bottom plate 35cm*35cm, 5mm thick fully welded.
48 Mtr ST Pole ST-410, SP-15 S.T. poles well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground level with earthing arrangement through bolt welded on pole of 14mm diameter, provided at height of 300mm above & bottom plate 35cm*35cm, 5mm thick fully welded.
59 Mtr. Long PCC Pole-WL-300Kg
68 Mtr. Long PCC Pole- WL-250Kg
7Installation, Testing and Commissioning (including loading, unloading and transportation upto 4 Km from Divisional store to different sites (including Manual Carriage upto 100 Mtr at site)-Material to be provided Departmentally) of
811 Mtr ST Pole ST-410 SP56
99 Mtr ST Pole ST-410, SP-33
108 Mtr ST Pole ST-410, SP-15
119 Mtr. Long PCC Pole- WL-300Kg
128 Mtr. Long PCC Pole-WL-200Kg
13Dismantling of damaged/Old Poles alongwith allied Materials and transportation of same to divisional store including loading and unloading
1411 Mtr ST Pole
1509 Mtr ST Pole
1608 Mtr ST Pole
179 Mtr PCC Pole
188 Mtr PCC Pole
199/8 Meter Wooden poles along with Fixtures
20Dismantling of damaged/Old Pole alongwith allied Materials excluding Transportation charges
2111 Mtr ST Pole
2209 Mtr ST Pole
2308 Mtr ST Pole
248 Mtr PCC Pole
259 Mtr PCC Pole
269/8 Meter Wooden poles along with Fixtures
27Re-erection of fallen/available Pole at site alongwith allied Materials of same within the radius of 50 Mtrs of initial site
2811 Mtr ST Pole
2909 Mtr ST Pole
3008 Mtr ST Pole
318 Mtr PCC Pole
329 Mtr PCC Pole
339/8 Meter Wooden poles along with Fixtures
34Re- Straightening of Tilted Poles complete job
35Manual Carriage Charges for Steel Tabular Pole 11Mtr/9mtr/8 mtr for every additional 50 mtr (including unloading/Loading)
36Manual Carriage Charges for PCC 9mtr/8 mtr for every additional 50 mtr (including unloading/Loading)
37Supply, laying, stringing, Testing and Commissioning of ACSR conforming with the Indian Standard specification IS: 398 (PLI)-1976 and IS : 398 (PL II)- 1976 or the latest version thereof.
3830 Sqmm ACSR
3950 Sqmm ACSR
40100 Sqmm ACSR
41Laying, stringing, Testing and Commissioning (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-(Material to be provided Departmentally) of ACSR conforming with the Indian Standard specification IS: 398 (PLI)-1976 and IS : 398 (PL II)- 1976 or the latest version thereof.
4230 Sqmm ACSR
4350 Sqmm ACSR
44100 Sqmm ACSR
45Dismantling of ACSR Conductor and transportation of same to divisional store including loading and unloading
4630 Sqmm ACSR
4750 Sqmm ACSR
48100 Sqmm ACSR
49Dismantling of ACSR Conductor excluding Transportation charges
5030 Sqmm ACSR
5150 Sqmm ACSR
52100 Sqmm ACSR
53Relaying/re-erection of available conductor at site or re- Straightening of loose Conductor/Fallen Conductor after opening of bindings and refixing thereof.
5430 Sqmm ACSR
5550 Sqmm ACSR
56100 Sqmm ACSR
57Supply, Installation, Testing and Commissioning of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nutbolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
58Installation, Testing and Commissioning of Galvanised Stay Set complete (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
59Supply, fabrication and fixing (including loading, unloading and transportation of Channel Iron X-arm/V cross Arm of different sorts (100x50x50x6 mm,75x40x6mm (Galvanized as per IS) including Top Bracket, Clamps & Braces of different sizes, (Galvanized as per IS)
60Fabrication and fixing (including loading, unloading and transportation of Channel Iron X-arm/V cross Arm of different sorts (100x50x50x6 mm,75x40x6mm (Galvanized as per IS) including Top Bracket, Clamps & Braces of different sizes, (Galvanized as per IS) (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
61Fixing of Channel Iron/ Angle Braces of different sizes available at site
62Dismantling of Channel Iron/ Angle Braces of different sizes including loading/unloading/transportation of same to divisional store including loading and unloading
63Dismantling of Channel Iron/ Angle Braces of different sizes excluding transportation charges
64Supply and Fixing of GI Pole Support Back Clamp/collar
6511 Mtr Pole with size - 50x8x376 mm
669 mtr pole with size - 50x8x376 mm
678 mtr with size 50x 8x 332 mm
688 mtr or 9 mtr PCC with size 50x8x441mm
69Fixing of GI Pole Support Back Clamp/collar (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
7011 Mtr Pole with size - 50x8x376 mm
719 mtr pole with size - 50x8x376 mm
728 mtr with size 50x 8x 332 mm
738 mtr or 9 mtr PCC with size 50x8x441mm
74Supply and Fixing of Cable tie 4.8 x 250 mm (each packet contains 100 Nos.)
75Fixing of Cable tie (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
76Supply and Fixing of Cable end caps
77Fixing of Cable end caps (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
78Supply, installation, testing and Commissioning of Insulating Piercing Connectors
79Installation, testing and Commissioning of Insulating Piercing Connectors (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
80Supply, installation, testing and Commissioning of 3 Phase SMDB (Service Main Distribution Box) IP54 made from 20 SWG CRCA MS sheetby Deep drawn method with connection terminals for R,Y, B & N as per specifications. Internal size of the box shall be 225mm x 285mm x 120mm used for connection through ABC line and for giving connections to the consumers 3phase-1 incoming 4 outgoing I/C- 1, O/G-2-4 (200 A, 0.415 kV) for RYB Phase. The DB should have Bottom entry of Cable with proper Glands/grommets-Safety Screws and Back Clamp suitable for 11/9/8 Mtr ST Pole or 9/8 mtr PCC poles with Nuts/bolts. The job also includes disconnection/reconnection of consumer energy meter including providing of aluminium lugs, if required.
81Installation, testing and Commissioning of SMDB (Service Main Distribution Box). The job also includes disconnection/reconnection of consumer energy meter including providing of aluminium lugs, if required. (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
82Dismantling of Damaged/old SMD Box and transportation of same to divisional store including loading and unloading
83Dismantling of Damaged/old SMD Box excluding transportation.
84Fixing of Old/available SMD Box at site
85Supply and fixing (including loading, unloading and transportation) of Nuts and Bolts full thread of sizes Galvanized as per IS
86Fixing (including loading, unloading and transportation) of Nuts and Bolts full thread of sizes Galvanized as per IS (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
87Supply, Installation, Testing and commissioning of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
88Installation, Testing and commissioning of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally
89Supply, Installation, Testing and Commissioning (including loading, unloading and transportation) of 11KV Pin Insulators with Pins (5KN)
90Installation, Testing and Commissioning (including loading, unloading and transportation) of 11KV Pin Insulators with Pins (5KN) (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
91Providing and laying of earthing of earthing complete by GI Pipe 40 mm or GI rod 20 mm 2.5 mtr long through GI Strip
92Laying of earthing of earthing complete by GI Pipe 40 mm or GI rod 20 mm 2.5 mtr long through GI Strip (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
93Providing and laying of Earthing of Substation---Excavation of earth pit of dia 650mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as per IS 1239. GI strip for neutral earthing of size 25mm*3mm for connection of transformer body, G.O Set & lightening Arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials & earth chamber made of brick masonry with RCC slab cover.
94Supply, Installation, Testing and Commissioning (including loading, unloading and transportation) of Danger Plate With Clamps as per Standards.
95Installation, Testing and Commissioning (including loading, unloading and transportation) of Danger Plate With Clamps as per Standards. (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
96Supply, Installation, Testing and Commissioning (including loading, unloading and transportation) of GI Barbed Wire.
97Installation, Testing and Commissioning of GI Barbed Wire (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
98Supply, Installation, Testing and Commissioning (including loading, unloading and transportation) of Anti-Climbing Device with Clamps
99Installation, Testing and Commissioning of Anti-Climbing Device with Clamps (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
100Supply and Painting of ST poles with one coat of Red Oxide primer and two coats of Aluminum paint.
101Painting of ST poles with one coat of Red Oxide primer and two coats of Aluminum paint. (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
102Providing of material and laying of Cement bottoming of poles
1031:2:4 Mix as per REC Standards 0.66 M3 per Pole
1041:2:4 Mix as per REC Standards 0.48 M3 per Pole
1051:2:4 Mix as per REC Standards 0.40 M3 per Pole
106Providing of material and laying of Stone pad (300x300x75 mm)
107Laying of Stone pad (300x300x75 mm) (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
108Supply, Installation, Testing and Commissioning (including loading, unloading and transportation) of 16 KN Polymer Shackle Insulator alongwith G.I. U-Clamps/pole collar for Shackle insulators
109Installation, Testing and Commissioning (including loading, unloading and transportation) of 16 KN Polymer Shackle Insulator alongwith G.I. U-Clamps/pole collar for Shackle insulators (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
110Supply and fixing of PG Clamps for
11130/ 50 mm² ACSR Conductor
112100 mm² ACSR Conductor
113150 mm² ACSR Conductor
114Fixing of PG Clamps (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
11530/ 50 mm² ACSR Conductor
116100 mm² ACSR Conductor
117150 mm² ACSR Conductor
118Supply, Laying, Installation, Testing and Commissioning of 11 kV, 3- Core XLPE flat strip Armoured, FRLS Cable
119120 mm²
120150 mm²
121185 mm²
122240 mm²
123300 mm²
124400 mm²
125Laying, Installation, Testing and Commissioning of 11 kV, 3- Core XLPE flat strip Armoured, FRLS Cable (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
126120 mm²
127150 mm²
128185 mm²
129240 mm²
130300 mm²
131400 mm²
132Dismantling of damaged/Old 11 kV, 3- Core XLPE Cable of different sizes and transportation of same to divisional store including loading and unloading
133Dismantling of damaged/Old 11 kV, 3- Core XLPE Cable of different sizes excluding transportation
134Re-erection of available 11 kV, 3- Core XLPE Cable of different sizes within the radius of 50 Mtrs
135Supply, Laying, Installation, Testing and Commissioning of 11 kV, Single core Aluminium Flat strip Armoured XLPE Cable, FRLS
136120 mm²
137150 mm²
138185 mm²
139240 mm²
140300 mm²
141400 mm²
142630 mm²
143Laying, Installation, Testing and Commissioning of 11 kV, Single core Aluminium Flat strip Armoured XLPE Cable, FRLS (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
144120 mm²
145150 mm²
146185 mm²
147240 mm²
148300 mm²
149400 mm²
150630 mm²
151Dismantling of damaged/Old 11 kV, 1- Core XLPE Cable of different sizes and transportation of same to divisional store including loading and unloading
152Dismantling damaged/Old 11 kV, 1- Core XLPE Cable of different sizes excluding transportation.
153Re-erection of available/Old 11 kV, 1- Core XLPE Cable of different sizes within the radius of 50 Mtrs
154Supply, Laying, Installation, Testing and Commissioning of 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS
15525 mm²
15635 mm²
15750 mm²
15870 mm²
15995 mm²
160120 mm²
161150 mm²
162185 mm²
163240 mm²
164300 mm²
165400 mm²
166500 mm²
167Laying, Installation, Testing and Commissioning of 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
16825 mm²
16935 mm²
17050 mm²
17170 mm²
17295 mm²
173120 mm²
174150 mm²
175185 mm²
176240 mm²
177300 mm²
178400 mm²
179500 mm²
180Dismantling of damaged/Old 3½ Core Cable,1.1kV Grade, Armoured, XLPE Cable of different sizes and transportation of same to divisional store including loading and unloading
181Dismantling of damaged/Old 3½ Core Cable,1.1kV Grade, Armoured, XLPE Cable of different sizes excluding transportation.
182Re-erection of available/Old 3½ Core Cable,1.1kV Grade, Armoured, XLPE Cable of different sizes within the radius of 50 Mtrs
183Supply, Laying, Installation, Testing and Commissioning of Single Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type including Lugs/Thimbles/Clamps
18470 mm²
18595 mm²
186120 mm²
187150 mm²
188185 mm²
189240 mm²
190300 mm²
191400 mm²
192500 mm²
193630 mm²
194Laying, Installation, Testing and Commissioning of Single Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
19570 mm²
19695 mm²
197120 mm²
198150 mm²
199185 mm²
200240 mm²
201300 mm²
202400 mm²
203500 mm²
204630 mm²
205Dismantling of damaged/Old 1- Core Cable,1.1kV Grade, Armoured, XLPE Cable of different sizes and transportation of same to divisional store including loading and unloading
206Dismantling damaged/Old 1- Core Cable,1.1kV Grade, Armoured, XLPE Cable of different sizes excluding transportation.
207Re-erection of available/Old 1- Core Cable,1.1kV Grade, Armoured, XLPE Cable of different sizes within the radius of 50 Mtrs
208Supply, Laying, Installation, Testing and Commissioning of Single Core Cable,1.1kV Grade, Un-Armoured, XLPE Insulated Stranded Conductor FRLS type including Lugs/Thimbles/Clamps
20935 mm²
21050 mm²
21170 mm²
21295 mm²
213120 mm²
214150 mm²
215185 mm²
216240 mm²
217300 mm²
218400 mm²
219500 mm²
220630 mm²
221Laying, Installation, Testing and Commissioning of Single Core Cable,1.1kV Grade, Un-Armoured, XLPE Insulated Stranded Conductor FRLS type (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
22235 mm²
22350 mm²
22470 mm²
22595 mm²
226120 mm²
227150 mm²
228185 mm²
229240 mm²
230300 mm²
231400 mm²
232500 mm²
233630 mm²
234Dismantling of damaged/Old 1- Core Cable,1.1kV Grade, Un-Armoured, XLPE Cable of different sizes and transportation of same to divisional store including loading and unloading
235Dismantling of damaged/Old 1- Core Cable,1.1kV Grade, Un-Armoured, XLPE Cable of different sizes excluding transportation
236Re-erection of available/Old 1- Core Cable,1.1kV Grade, Un-Armoured, XLPE Cable of different sizes within the radius of 50 Mtrs
237Supply, Installation, testing and commissioning of HT Air Bundled Cable on ST/PCC Poles including Lugs/Thimbles/Clamps
23835 mm² AB (HT) Cable (3x35+1x70 insulated) mm² XLPE (11 kV, 3C + Earth)
23935 mm² AB (HT) Cable (3x35+1x35 mm² insulated) mm² XLPE
24050 mm² AB (HT) Cable (3x50 + 1x70 insulated) mm² XLPE (11 kV, 3C + Earth)
24170 mm² AB (HT) Cable (3x70+1x70 insulated) mm² XLPE (11 kV, 3C + Earth)
24270 mm² AB (HT) Cable (3 x 70 + 1x95 insulated) mm² XLPE(11 kV, 3C + Earth)
24395 mm² AB (HT) Cable (3x95+1x95 insulated) mm² XLPE(11 kV, 3C + Earth)
244120 mm² AB (HT) Cable (3x120 + 1x95 mm² insulated) XLPE(11 kV, 3C + Earth)
245185 mm² AB (HT) Cable (3x185+1x120 insulated) mm² XLPE(11 kV, 3C + Earth)
246Installation, testing and commissioning of HT Air Bundled Cable on ST/PCC Poles (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
24735 mm² AB (HT) Cable (3x35+1x70 insulated) mm² XLPE (11 kV, 3C + Earth)
24835 mm² AB (HT) Cable (3x35+1x35 mm² insulated) mm² XLPE
24950 mm² AB (HT) Cable (3x50 + 1x70 insulated )mm² XLPE (11 kV, 3C + Earth)
25070 mm² AB (HT) Cable (3x70+1x70 insulated)mm² XLPE (11 kV, 3C + Earth)
25170 mm² AB (HT) Cable (3 x 70 + 1x95 insulated)mm² XLPE(11 kV, 3C + Earth)
25295 mm² AB (HT) Cable (3x95+1x95 insulated)mm² XLPE(11 kV, 3C + Earth)
253120 mm² AB (HT) Cable (3x120 + 1x95 mm² insulated) XLPE(11 kV, 3C + Earth)
254185 mm² AB (HT) Cable (3x185+1x120 insulated) mm² XLPE(11 kV, 3C + Earth)
255Dismantling of damaged/Old HT Air Bundled Cable of different sizes and transportation of same to divisional store including loading and unloading
256Dismantling of damaged/Old HT Air Bundled Cable of different sizes excluding transportation.
257Re-erection of damaged/Old HT Air Bundled Cable of different sizes within the radius of 50 Mtrs
258Supply, Installation, testing and commissioning of LT Air Bundled Cable on ST/PCC Poles including Lugs/Thimbles/Clamps
25935 mm² AB (LT) Cable ( 3 x 35 + 1 x 16 + 1 x 25 insulated) mm² XLPE (1.1kV, 3+1 C, Al)
26050 mm² AB (LT) Cable ( 3 x 50 + 1 x 16 + 1 x 35 insulated)mm² XLPE (1.1kV, 3+1 C, Al)
26170 mm² AB (LT) Cable ( 3 x 70 + 1 x 16 + 1 x 50 mm²) XLPE (1.1kV, 3+1 C, Al)
262120 mm² AB (LT) Cable ( 3 x 120 + 1 x 25 + 1 x 95 insulated) mm² XLPE (1.1kV, 3+1 C, Al)
263185 mm² AB (LT) Cable ( 3 x 185 + 1 x 16 + 1 x 95 insulated) mm² XLPE (1.1kV, 3+1 C, Al)
264Installation, testing and commissioning of LT Air Bundled Cable on ST/PCC Poles (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
26535 mm² AB (LT) Cable ( 3 x 50 + 1 x 16 + 1 x 35 mm²) XLPE (1.1kV, 3+1 C, Al)
26650 mm² AB (LT) Cable ( 3 x 50 + 1 x 16 + 1 x 35 mm²) XLPE (1.1kV, 3+1 C, Al)
26770 mm² AB (LT) Cable ( 3 x 70 + 1 x 16 + 1 x 50 mm²) XLPE (1.1kV, 3+1 C, Al)
268120 mm² AB (LT) Cable ( 3 x 120 + 1 x 16 + 1 x 70 mm²) XLPE (1.1kV, 3+1 C, Al)
269185 mm² AB (LT) Cable ( 3 x 185 + 1 x 16 + 1 x 95 mm²) XLPE (1.1kV, 3+1 C, Al)
270Dismantling of damaged/Old LT Air Bundled Cable of different sizes and transportation of same to divisional store including loading and unloading
271Dismantling of damaged/Old LT Air Bundled Cable of different sizes within the radius of 50 Mtrs
272Dismantling & re-erection of damaged/Old LT Air Bundled Cable of different sizes within the radius of 50 Mtrs of initial site
273Providing and fixing of Aluminum Lugs/Thimbles of sizes & types
27410 SQMM
27516 SQMM
27625 SQMM
27735 SQMM
27850 SQMM
27970 SQMM
28095 SQMM
281120 SQMM
282150 SQMM
283185 SQMM
284240 SQMM
285300 SQMM
286400 SQMM
287500 SQMM
288630 SQMM
289Providing and fixing of Heavy Duty Copper Lugs/Thimbles of sizes & types
29010 SQMM
29116 SQMM
29225 SQMM
29335 SQMM
29450 SQMM
29570 SQMM
29695 SQMM
297120 SQMM
298150 SQMM
299185 SQMM
300240 SQMM
301300 SQMM
302400 SQMM
303500 SQMM
304630 SQMM
305Fixing of Aluminum/copper Lugs/Thimbles of sizes & types
30610 SQMM
30716 SQMM
30825 SQMM
30935 SQMM
31050 SQMM
31170 SQMM
31295 SQMM
313120 SQMM
314150 SQMM
315185 SQMM
316240 SQMM
317300 SQMM
318400 SQMM
319500 SQMM
320630 SQMM
321Installation, Testing and Commissioning of Distribution Transformer (including loading, unloading and transportation from one site to different sites (store/workshop/sites) upto the radius of 4 KM) (which includes arrangement of crane/sleepers/Trucks etc)
32225 KVA
32363 KVA
324100 KVA
325200 KVA
326250 KVA
327400 KVA
328630 KVA
3291 MVA
330Dismantling of Distribution Transformer (including loading, unloading and transportation from one site to different sites (store/workshop/sites) upto the radius of 4 KM) (which includes arrangement of crane/sleepers/Trucks etc)
33125 KVA
33263 KVA
333100 KVA
334200 KVA
335250 KVA
336400 KVA
337630 KVA
3381 MVA
339Installation and Commissioning of Distribution Transformer available at site including integration with system by way of providing necessary material
34025 KVA
34163 KVA
342100 KVA
343200 KVA
344250 KVA
345400 KVA
346630 KVA
3471 MVA
348Supply, installation, testing and commissioning of LT Distribution Box for (As per the Specifications Enclosed).
34925 kVA DTR with 40 Amp MCCB 3P 16 kA for incomer & 25 Amp MCCB 3P 16 kA/10 kA 1 No each (=2No.) for Outgoing Circuits.
35063 kVA DTR with 100 Amp MCCB 3P 16 kA for incomer & 100 Amp MCCB 3P 16 kA 1 No. and 63 Amp MCCB 3P 16 kA 1 No.s for Outgoing Circuits.
351100 kVA DTR with 160 MCCB 3P 16 kA for incomer & 100 Amp MCCB 3P 16 kA 2 No.s for Outgoing Circuits
352200 kVA DTR with 315 Amp MCCB 3P 25 kA for incomer & 160 Amp MCCB 3P 16 kA 3 No.s for Outgoing Circuits.
353250 kVA DTR with 400 Amp MCCB 3P 36 kA for incomer & 200 Amp MCCB 3P 16 kA 1 No. and 160 Amp MCCB 3P 16 kA 2 No.s for Outgoing Circuits.
354400 kVA DTR with 630 Amp MCCB 3P (36 KA) adjustable 1 No. for incomer & 200 Amp 3 P (16 KA) 4 No.s fixed for Outgoing Circuits
355630 kVA DTR with 1000 Amp MCCB 3P (36 KA) adjustable 1 No. for incomer & 250 Amp MCCB 3 P (25 KA) 2 No.s fixed & 200 Amp MCCB 3 P (25 KA) 3 No.s for Out going.
356Installation, testing and commissioning of LT Distribution Box (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally) for
35725 kVA DTR with 40 Amp MCCB 3P 16 kA for incomer & 25 Amp MCCB 3P 16 kA/10 kA 1 No each (=2No.) for Outgoing Circuits .
35863 kVA DTR with 100 Amp MCCB 3P 16 kA for incomer & 100 Amp MCCB 3P 16 kA 1 No. and 63 Amp MCCB 3P 16 kA 1 No.s for Outgoing Circuits.
359100 kVA DTR with 160 MCCB 3P 16 kA for incomer & 100 Amp MCCB 3P 16 kA 2 No.s for Outgoing Circuits
360200 kVA DTR with 315 Amp MCCB 3P 25 kA for incomer & 160 Amp MCCB 3P 16 kA 3 No.s for Outgoing Circuits.
361250 kVA DTR with 400 Amp MCCB 3P 36 kA for incomer & 200 Amp MCCB 3P 16 kA 1 No. and 160 Amp MCCB 3P 16 kA 2 No.s for Outgoing Circuits.
362400 kVA DTR with 630 Amp MCCB 3P (36 KA) adjustable 1 No. for incomer & 200 Amp 3 P (16 KA) 4 No.s fixed for Outgoing Circuits
363630 kVA DTR with 1000 Amp MCCB 3P (36 KA) adjustable 1 No. for incomer & 250 Amp MCCB 3 P (25 KA) 2 No.s fixed & 200 Amp MCCB 3 P (25 KA) 3 No.s for Out going.
364Supply, installation, laying, testing and commissioning of LT Distribution Box for1600 Amp 4P ACB Drawal type , Breaking Capacity 50kA with enclosure
365Installation, testing and commissioning of LT Distribution Box for 1600 Amp ACB Drawal type 36 kA with enclosure for 1 MVA DT (including loading, unloading and transportation from Divisional store to different sites-Material to be provided Departmentally)
366Supply, installation, laying, testing and commissioning of LT Distribution Box for MCCB 630 Amp adjustable type 4P 36 KA with Box for 1 MVA DT
367Installation, testing and commissioning of LT Distribution Box for MCCB 630 Amp adjustable type 4P 36 KA with Box for 1 MVA DT (including loading, unloading and transportation from Divisional store to different sites upto 4 Km-Material to be provided Departmentally)
368Supply, installation, commissioning and Testing of LT Fuse Set (Customised) for Distribution Transformers as per KPDCL Drawing no. CE/P&P/DRG/2023/LTFS/001 (enclosed)
36925 KVA
37063 KVA
371100 KVA
372200 KVA
373250 KVA
374400 KVA
375630 KVA
3761 MVA
377Installation, commissioning and Testing of LT Fuse Set (Customised) for Distribution Transformers (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
37825 KVA
37963 KVA
380100 KVA
381200 KVA
382250 KVA
383400 KVA
384630 KVA
3851 MVA
386Dismantling of damaged/Old LT Fuse Set of different sizes and transportation of same to divisional store including loading and unloading
387Dismantling of damaged/Old LT Fuse Set of different sizes excluding transportation.
388Installation/Re-erection of available Old LT Fuse Set of different sizes
389Supply, installation, commissioning and Testing of G.I Pipe of 150 mm dia 3 mtr long for Pole Butts (6\\")
390Fixing of G.I Pipe of 150 mm dia 3 mtr long for Pole Butts (6\\") (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
391Dismantling of G.I Pipe of 150 mm dia 3 mtr long for Pole Butts (6\\") and transportation of same to divisional store including loading and unloading
392Supply, Installation, Testing and Commissioning of 11 KV Horn, Gap (fuse 3-phase 200A) as per Relevant IS
393Installation, Testing and Commissioning of 11 KV Horn Gap (fuse 3-phase 200A) as per Relevant IS (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally)
394Dismantling of 11 KV Horn Gap and transportation of same to divisional store including loading and unloading
395Dismantling of 11 KV Horn Gap excluding transportation
396Fixing and commissioning of of available/ old 11 KV Horn Gap
397Supply,Installation, Testing and Commissioning of Gapless Surge Arrestor, 9 KV, 10 KA, Lighting Arrestor Set Heavy duty with Polymer Housing, Station type conforming to IEC-99-4 Capable of withstanding Maximum continuous operating voltages (M.C.O.V)
398Installation, Testing and Commissioning of Gapless Surge Arrestor, 9 KV, 10 KA, Lighting Arrestor Set Heavy duty with Polymer Housing, Station type conforming to IEC-99-4 Capable of withstanding Maximum continuous operating voltages (M.C.O.V) (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally)
399Dismantling of 11 KV Gapless Surge Arrestor and transportation of same to divisional store including loading and unloading
400Dismantling of 11 KV Gapless Surge Arrestor excluding transportation
401Fixing and commissioning of of available/ old 11 KV Gapless Surge Arrestor
402Supply, Installation, Testing and Commissioning of 11KV 200 Amperes, Triple pole switches Gang Operated (G.O. Set) conforming: IS-2544, IS: 5340 (Part-III) and SS: 9921 (Part-I -V)
403Installation, Testing and Commissioning of 11KV 200 Amperes, Triple pole switches Gang Operated (G.O. Set) conforming: IS-2544, IS: 5340 (Part-III) and SS: 9921 (Part-I -V) (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally)
404Dismantling of 11KV 200 Amperes, Triple pole switches Gang Operated (G.O. Set) and transportation of same to divisional store including loading and unloading
405Dismantling of 11KV 200 Amperes, Triple pole switches Gang Operated (G.O. Set) excluding transportation
406Fixing and commissioning of of available/ old 11KV 200 Amperes, Triple pole switches Gang Operated (G.O. Set)
407Supply, Installation, testing and commissioning of Suspension/Tension Clamp with eye hook
408Installation, testing and commissioning of Suspension/Tension Clamp with eye hook (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally)
409Supply and Fixing of Mid Span Straight Through Jointing Kit for 11 kV ABC 50-95mm2
410Fixing of Mid Span Straight Through Jointing Kit for 11 kV ABC 50-95mm2 (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
411Supply and Fixing of Mid Span Straight Through Jointing Kit for 11 kV ABC 120-185mm2
412Fixing of Mid Span Straight Through Jointing Kit for 11 kV ABC 120-185mm2 (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
413Supply and Fixing of Straight Through Joints for Straight Through Jointing Kit for 70-120 mm², 11 KV Single Core Cable
414Fixing of Straight Through Joints for Straight Through Jointing Kit for 70-120 mm², 11 KV Single Core Cable (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
415Supply and Fixing of Straight Through Joints for Straight Through Jointing Kit for 150-185 mm², 11 KV Single Core Cable
416Fixing of Straight Through Joints for Straight Through Jointing Kit for 150-185 mm², 11 KV Single Core Cable (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
417Supply and Fixing of Straight Through Joints for Straight Through Jointing Kit for 240-300 mm² mm², 11 KV Single Core Cable
418Fixing of Straight Through Joints for Straight Through Jointing Kit for 240-300 mm² mm², 11 KV Single Core Cable (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
419Supply and Fixing of Straight Through Joints for Straight Through Jointing Kit for 400-500 mm², 11 KV Single Core Cable
420Fixing of Straight Through Joints for Straight Through Jointing Kit for 400-500 mm², 11 KV Single Core Cable (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
421Supply and Fixing of Straight Through Joints for Straight Through Jointing Kit for 630-800 mm², 11 KV Single Core Cable
422Fixing of Straight Through Joints for Straight Through Jointing Kit for 630-800 mm², 11 KV Single Core Cable (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
423Supply and Fixing of Straight Through Jointing Kit upto 50-95 mm², 11 KV Three Core Cable
424Fixing of Straight Through Jointing Kit upto 50-95 mm², 11 KV Three Core Cable (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
425Supply and Fixing of Straight Through Jointing Kit upto 120-185 mm², 11 KV Three Core Cable
426Fixing of Straight Through Jointing Kit upto 120-185 mm², 11 KV Three Core Cable (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
427Supply and Fixing of Straight Through Jointing Kit upto 240-300 mm², 11 KV Three Core Cable
428Fixing of Straight Through Jointing Kit upto 240-300 mm², 11 KV Three Core Cable(including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
429Supply and Fixing of Straight Through Jointing Kit upto 400- 500 mm², 11 KV Three Core Cable
430Fixing of Straight Through Jointing Kit upto 400- 500 mm², 11 KV Three Core Cable (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
431Supply and Fixing of Straight Through Jointing Kit upto 25-50 mm², 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS
432Fixing of Straight Through Jointing Kit upto 25-50 mm², 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
433Supply and Fixing of Straight Through Jointing Kit upto 70-95 mm², 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS
434Fixing of Straight Through Jointing Kit upto 70-95 mm², 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
435Supply and Fixing of Straight Through Jointing Kit upto 120-150 mm², 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS
436Fixing of Straight Through Jointing Kit upto 120-150 mm², 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
437Supply and Fixing of Straight Through Jointing Kit upto 185-240 mm², 3½ Core Cable, 1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS
438Fixing of Straight Through Jointing Kit upto 185-240 mm², 3½ Core Cable, 1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
439Supply and Fixing of Straight Through Jointing Kit for 300 mm², 3½ Core Cable, 1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS
440Fixing of Straight Through Jointing Kit for 300 mm², 3½ Core Cable, 1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS(including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
441Supply and Fixing of Straight Through Jointing Kit upto 400 mm², 3½ Core Cable, 1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS
442Fixing of Straight Through Jointing Kit upto 400 mm², 3½ Core Cable, 1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
443Supply and Fixing of Straight Through Jointing Kit upto 500 -630 mm², 3½ Core Cable, 1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS
444Fixing of Straight Through Jointing Kit upto 500 -630 mm², 3½ Core Cable, 1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
445Supply & Fixing of Straight Through Cable Jointing Kit for50 mm² AB (LT) Cable ( 3 x 50 + 1 x 16 + 1 x 35 insulated) mm² XLPE (1.1kV, 3+1 C, Al)
446Fixing of Straight Through Cable Jointing Kit for 70 mm² AB (LT) Cable ( 3 x 70 + 1 x 16 + 1 x 50 insulated) mm² XLPE (1.1kV, 3+1 C, Al) (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
447Supply & Fixing of Straight Through Cable Jointing Kit for 70 mm² AB (LT) Cable ( 3 x 70 + 1 x 16 + 1 x 50 insulated) mm² XLPE (1.1kV, 3+1 C, Al)
448Fixing of Straight Through Cable Jointing Kit for 50 mm² AB (LT) Cable ( 3 x 50 + 1 x 16 + 1 x 35 insulated) mm² XLPE (1.1kV, 3+1 C, Al) (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
449Supply & Fixing of Straight Through Cable Jointing Kit for 120 mm² AB (LT) Cable ( 3 x 120 + 1 x 25 + 1 x 95 insulated) mm² XLPE (1.1kV, 3+1 C, Al)
450Fixing of Straight Through Cable Jointing Kit for 120 mm² AB (LT) Cable ( 3 x 120 + 1 x 25 + 1 x 95 insulated) mm² XLPE (1.1kV, 3+1 C, Al) (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
451Supply and Fixing of 11 kV Heat Shrinkable Outdoor Cable End termination for 3C, 70 - 95 mm²
452Fixing of 11 kV Heat Shrinkable Outdoor Cable End termination for 3C, 70 - 95 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
453Supply and Fixing of 11 kV Heat Shrinkable Outdoor Cable End termination for 3C, 120 mm²
454Fixing of 11 kV Heat Shrinkable Outdoor Cable End termination for 3C, 120 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
455Supply and Fixing of 11 kV Heat Shrinkable Outdoor Cable End termination for 3C, 150 - 185 mm²
456Fixing of 11 kV Heat Shrinkable Outdoor Cable End termination for 3C, 150 - 185 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
457Supply and Fixing of 11 kV Heat Shrinkable Outdoor Cable End termination for 3C, 240 - 300 mm²
458Fixing of 11 kV Heat Shrinkable Outdoor Cable End termination for 3C, 240 - 300 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
459Supply and Fixing of 11 kV Heat Shrinkable Outdoor Cable End termination for 3C, 400 mm²
460Fixing of 11 kV Heat Shrinkable Outdoor Cable End termination for 3C, 400 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
461Supply and Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 70 mm² to 95 mm²
462Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 70 mm² to 95 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
463Supply and Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 120 mm²
464Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 120 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
465Supply and Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 150 mm² to 240 mm²
466Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 150 mm² to 240 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
467Supply and Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 300 mm²
468Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 300 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
469Supply and Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 400 mm²
470Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 400 mm²
471Supply and Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 630 mm²
472Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 630 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
473Supply and Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 800 mm²
474Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 800 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
475Supply and Fixing of Heat Shrinkable Outdoor Cable Termination Kit for 11 kV ABC 50-95 mm²
476Fixing of Heat Shrinkable Outdoor Cable Termination Kit for 11 kV ABC 50-95 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
477Supply and Fixing of Heat Shrinkable Outdoor Cable Termination Kit for 11 kV ABC 120-185 mm²
478Fixing of Heat Shrinkable Outdoor Cable Termination Kit for 11 kV ABC 120-185 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
479Supply and Fixing of Heat Shrinkable End termination for 3½ C, 35-50 mm²
480Fixing of Heat Shrinkable End termination for 3½ C, 35-50 mm²(including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
481Supply and Fixing of Heat Shrinkable End termination for 3½ C, 70-150 mm²
482Fixing of Heat Shrinkable End termination for 3½ C, 70-150 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
483Supply and Fixing of Heat Shrinkable End termination for 3½ C, 35-50 mm²
484Fixing of Heat Shrinkable End termination for 3½ C, 35-50 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
485Supply and Fixing of Heat Shrinkable End termination for 3½ C, 35-50 mm²
486Fixing of Heat Shrinkable End termination for 3½ C, 35-50 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
487Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.
488All kinds of soil
489Ordinary Rock
490Providing of Stone Soling (Supplying, Laying, spreading and compacting stone aggregate of 90 mm to 45 mm
491Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
492Centering and shuttering including strutting, propping etc. and removal of form work
493Engaging labour for carrying out pruning/ branch cutting of trees
494Unskilled
495Semi-Skilled
496Skilled
497Shifting of Street Lights
498Disconnection of Power Connections of Street Light from Bare Conductor and reconnection to LT AB Cable by use of Piercing Connectors including providing of IPCs.
499Disconnection of Power Connections of Street Light from Bare Conductor and reconnection to LT AB Cable by use of Piercing Connectors excluding the supply cost of IPC.
500Disconnection of Power Connections of Street Light from Bare Conductor and reconnection to SMD Box. The job includes providing of I/Y thimbles/lugs/nuts/bolts etc.
501Relocation of Street Light from old Pole to new pole equipped with LT AB cable. The job includes diconnection from old pole, shifting of light to new pole and connecting to LT AB Cable by use of Piercing Connectors including providing of IPCs.
502Relocation of Street Light from old Pole to new pole equipped with LT AB cable. The job includes diconnection from old pole, shifting of light to new pole and connecting to LT AB Cable by use of Piercing Connectors excluding the supply cost of IPC.
503Relocation of Street Light from old Pole to new pole equipped with LT AB cable. The job includes diconnection from old pole, shifting of light to new pole and connecting to SMD Box. The job includes providing of I/Y thimbles/lugs/nuts/bolts etc.
504Installation/Fixing of new Street light to SMD Box. The job includes providing of thimbles/lugs/nuts/bolts etc.
505Installation/Fixing of new Street light to LT AB Cable by use of Piercing Connectors (excluding the cost of IPC).
506Supply, laying, testing and commissioning of 3x1.0 mm² PVC insulated multistrand flexible copper wire for service connections from connection plate to the LED luminary individual circuit including loop & earthings laid properly.
507Supply, Installation, testing & commissioning of Pre fabricate galvanized single way top bracket (1000 mm long with 48.3 OD GI Pipe) along with complete accessories/mountings
508Installation, testing & commissioning of Pre fabricate galvanized single way top bracket (1000 mm long with 48.3 OD GI Pipe)
509Dismantling of galvanized single way top bracket of street light along with complete accessories/mountings
510Illumination/Decoration of Govt Buildings
511Installation of LED String lights having LEDs distributed to form the Indian tricolor Flag Saffron (Top side), White (middle) & Green (Bottom end) for decoration / illumination of Govt Buildings. The job is inclusive of interconnection of strings, controllers and extention boards/wire if required along with watch and ward (LED Strings will be provided departmentally).
512Providing on Hire basis - Proper rated MCB, Power cable with thimbles/lugs, extension cords/boards for connecting LED strings per building. The job also incudes laying, installation, testing and commissioning inclusive of watch and ward.
513Installation, Testing & Commissioning (including Transportation, loading and unloading from Divisional store to different sites) of Single Phase Energy Meter including Clamps/Collar(Energy Meter to be provided Departmentally)
514Installation, Testing & Commissioning (including Transportation, loading and unloading from Divisional store to different sites) of 3 phase Smart Energy Meter including Clamps/Collar(Energy Meter to be provided Departmentally)
515Disconnection of Power Connections of Energy Meter(1 Phase / 3 Phase)/MSD Box from Bare Conductor and reconnection to LT AB Cable by use of Piercing Connectors including the providing of IPC
516Disconnection of Power Connections of Energy Meter(1 Phase / 3 Phase)/MSD Box from Bare Conductor and reconnection to LT AB Cable by use of Piercing Connectors excluding the cost of IPC
517Disconnection of Power cable of Energy Meter(1 Phase / 3 Phase) from Bare conductor and reconnection to SMD Box including providing of I/Y type lugs, thimbles of sizes etc
518Connecting of New Energy Meters (Smart/Conventional) to MSD Box including providing of I/Y type lugs, thimbles of sizes etc
519Relocation (Dismantling and re-fixing) of Energy Meters (1 Phase / 3 Phase) (Smart/Conventional) from one Pole to another incl mounting structure/back clamps & Nuts and Bolts.
520Supply and fixing of Mounting arrangement of Single Meter as per the KPDCL Approved drawing no. CE/P&P/Dwg./2023/LTMA/001, Dated : 10-04-2023
521Supply and fixing of Mounting arrangement of Double Meters as per the KPDCL Approved drawing no. CE/P&P/Dwg./2023/LTMA/002 or 3, Dated : 10-04-2023
522Supply and fixing of Mounting arrangement of Three Meters as per the KPDCL Approved drawing no. CE/P&P/Dwg./2023/LTMA/004, Dated : 10-04-2023
523Supply and fixing of Mounting arrangement of Four Meters as per the KPDCL Approved drawing no. CE/P&P/Dwg./2023/LTMA/005, Dated : 10-04-2023
524Supply and fixing of Polypropylene weather proof outdoor type Meter Box for Single Phase Meter along withZinc plated clamps
525Fixing of Polypropylene weather proof outdoor type Meter Box for Single Phase Meter along withZinc plated clamps including loading and unloading from Divisional Stores to Different Sites
526Supply and fixing of Polypropylene weather proof outdoor type Meter Box for Three Phase Meter along with Zinc plated clamps
527Fixing of Polypropylene weather proof outdoor type Meter Box for Three Phase Meter along with Zinc plated clamps
528Supply, installation, testing and commissioning of Polypropylene weather proof outdoor type Meter Box for 4 Single Phase Meter along with Zinc plated clamps
529Installation, testing and commissioning of Polypropylene weather proof outdoor type Meter Box for 4 Single Phase Meter along with Zinc plated clamps including loading and unloading from Divisional Stores to Different Sites
530Supply, installation, testing and commissioning of 16 mm² Cable (2C), 1.1k V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type including Aluminum Lugs/thimbles of sizes
531Installation, testing and commissioning of 16 mm² Cable (2C), 1.1 kV Grade, Armoured, PVC Insulated Stranded Conductor FRLS type including Aluminum Lugs/thimbles of sizes (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally)
532Supply, installation, testing and commissioning of 10 mm² Cable (2C), 1.1 kV Grade, Armoured, PVC Insulated Stranded Conductor FRLS type including Aluminum Lugs/thimbles of sizes
533Installation, testing and commissioning of 10 mm² Cable (2C), 1.1 kV Grade, Armoured, PVC Insulated Stranded Conductor FRLS type including Aluminum Lugs/thimbles of sizes (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally)
534Supply, installation, testing and commissioning of 35 mm² Cable (2C), 1.1kV Grade, Armoured,XLPE Insulated Stranded Conductor FRLS type
535Installation, testing and commissioning of 35 mm² Cable (2C), 1.1kV Grade, Armoured,XLPE Insulated Stranded Conductor FRLS type (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally)
536Supply, installation, testing and commissioning of 16 mm² Cable (4C), 1.1 kV Grade, Armoured, PVC Insulated Stranded Conductor FRLS type including Aluminum Lugs/thimbles of sizes
537Installation, testing and commissioning of 16 mm² Cable (4C), 1.1 kV Grade, Armoured, PVC Insulated Stranded Conductor FRLS type including Aluminum Lugs/thimbles of sizes (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally)
538Supply, installation, testing and commissioning of 10 mm² Cable (4C) from LT Line to meter ,1.1k V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type including Aluminum Lugs/thimbles of sizes
539Installation, testing and commissioning of 10 mm² Cable (4C), 1.1kV Grade, Armoured, PVC Insulated Stranded Conductor FRLS type including Aluminum Lugs/thimbles of sizes (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally)
540Supply, installation, testing and commissioning of 35 mm² Cable (4C), 1.1kV Grade, Armoured,XLPE Insulated Stranded Conductor FRLS type
541Installation, testing and commissioning of 35 mm² Cable (4C), 1.1kV Grade, Armoured,XLPE Insulated Stranded Conductor FRLS type (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally)
542Supply, installation, testing and commissioning of 16 mm² Cable (2C), 1.1k V Grade, Un-Armoured, PVC Insulated Stranded Conductor FRLS type including Aluminum Lugs/thimbles of sizes
543Installation, testing and commissioning of 16 mm² Cable (2C), 1.1k V Grade, Un-Armoured, PVC Insulated Stranded Conductor FRLS type including Aluminum Lugs/thimbles of sizes (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally)
544Supply, installation, testing and commissioning of 10 mm² Cable (2C), 1.1k V Grade, Un-Armoured, PVC Insulated Stranded Conductor FRLS type including Aluminum Lugs/thimbles of sizes
545Installation, testing and commissioning of 10 mm² Cable (2C), 1.1k V Grade, Un-Armoured, PVC Insulated Stranded Conductor FRLS type including Aluminum Lugs/thimbles of sizes (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally)
546Supply, installation, Testing and commissioning of 11kV Pilfer resistant metering cubicle for 3phase 4 wire metering system made of MS Sheet steel thickness not less than 2mm duly power coat painted suitable for indoor as well as outdoor as per the site requirement. The cubicle shall be painted through 7-tank process. The External dimensions should be adequate. Panel having two compartments upper Meter compartment and lower CT/PT compartment. Provided with synthetic or semi synthetic gasket firmly glued to the sufrace, Dust, weather and Vermin proof and shall comply degree of protection IP 65 both the chambers having one sided hinged door arrangments. The metering panel shall be provided with two No MS channels of size 100 x 50 mm on the front and rear sides duly welded and 4 No of lifting hooks. It should be possible to take meter reading manually, through CMRI and computer without opening the LV chamber door.
547Supply, installation, Testing and commissioning of Single Phase, Single core, single ratio, Epoxy resin Cast Current Transformers suitable for 11kV, copper wound primary type with rated burden 5VA and accuracy class 0.5 or better and conforming to IS2705 (part-I & II) amended upto date. ISF shall be upto 5. The CT ratio shall be as under:
5482.5 /5 for 25kVA DT
5495/5 for 63kVA DT
5507.5/5 for 100 kVA DT
55115/5 for 200 kVA DT
55220/5 for 250 kVA DT
55325/5 for 400 kVA DT
55450/5 for 630 kVA DT
55575/5 for 1 MVA DT
556100 /5
557Supply, installation, Testing and commissioning of 11kV/ 110 V, Three phase epoxy resin cast PT with rated burden 15VA per phase and accuracy class 0.5 or better and conforming to IS:3156 (part-I&II) amended upto date with proper colour coded identification. PTs shall be of uniform insulating and withstand separate source 23kV pf for one minute.
558Supply and Fixing of Bus Bar details:CTs bus bar:- 40x6 mm copper strip or adequate size PTs bus bar: Copper wire 8 SWG or 30x0.6mm copper flat strip to connect PT terminal or adequate size duly insulated by the monoplast tape
559Supply, installation, testing and commissioning of PVC Copper wire flexible multi-strand of required size for secondary connections for CT wiring the minimum wire size shall be 4 mm2 (RYB) and for PT wiring minimum wire size shall be 2.5 mm2 (RYB).
560Supply and fixing of Copper Lugs preferably ring type duly crimped for termination of wires and tapes
561Supply and fixing of Grounding bus of minimum 40mm copper, 25cm long fixed to the unit in HV chamber. TheCTs, PT meter and 11kV Cable sheath shall be grounded to the bus through groundingwire (green) of min size 10mm2
562Supply, installation, testing and commissioning of 3Ph, 3 Wire HT CT/PT operated Fully static Smart Tri-Vector Energymeters DLMS CompliantCategory 'C' with RS232 port for modem compatibility. 11kV/110V, Ph-Ph (3P,3W) metersfor measurement of different electrical parameters including Active Energy (kWh/ MWh), Reactive Energy (kVArh/MVArh), Apparent Energy (kVAh/ MVAh) etc. (make L&T, Secure,ABB)
563Supply and fixing of Independent flexible PVC pipes for CT wiring and PT wiring of appropriate size from HTcompartment to meter compartment
564Supply and fixing of Pedestal made out of MS Channel of size 75 x 40 mm or angle iron of size 65 x 65 x 5 mm,duly painted as per site requirement for mounting of metering panel including concretefoundation wherever required including cost of nuts and bolts
565Supply and fixing of 3 Core 11 kV Aluminium cable XLPE armoured 35 mm2 including cost of clamp for its fixingwhere ever required.
566Supply and fixing of Cable termination kits suitable for 3 x 35 mm2 XLPE Cable(indoor/outdoor)
567Installation, Testing and commissioning of 11kV Pilfer resistant metering cubicle for 3phase 4 wire metering system made of MS Sheet steel thickness not less than 2mm duly power coat painted suitable for indoor as well as outdoor as per the site requirement. The cubicle shall be painted through 7-tank process. The External dimensions should be adequate. Panel having two compartments upper Meter compartment and lower CT/PT compartment. Provided with synthetic or semi synthetic gasket firmly glued to the sufrace, Dust, weather and Vermin proof and shall comply degree of protection IP 65 both the chambers having one sided hinged door arrangments. The metering panel shall be provided with two No MS channels of size 100 x 50 mm on the front and rear sides duly welded and 4 No of lifting hooks. It should be possible to take meter reading manually, through CMRI and computer without opening the LV chamber door. (Including unloading/loading/transportation from store to site)
568Installation, Testing and commissioning of Single Phase, Single core, single ratio, Epoxy resin Cast Current Transformers suitable for 11kV, copper wound primary type with rated burden 5VA and accuracy class 0.5 or better and conforming to IS2705 (part-I & II) amended upto date. ISF shall be upto 5The CT ratio shall be as under:(Including unloading/loading/transportation from store to site)
5692.5 /5 for 25kVA DT
5705/5 for 63kVA DT
5717.5/5 for 100 kVA DT
57215/5 for 200 kVA DT
57320/5 for 250 kVA DT
57425/5 for 400 kVA DT
57550/5 for 630 kVA DT
57675/5 for 1 MVA DT
577100 /5
578Installation, Testing and commissioning of 11kV/ 110 V, Three phase epoxy resin cast PT with rated burden 15VA per phase and accuracy class 0.5 or better and conforming to IS:3156 (part-I&II) amended upto date with proper colour coded identification. PTs shall be of uniform insulating and withstand separate source 23kV pf for one minute. (Including unloading/loading/transportation from store to site)
579Fixing of Bus Bar details:CTs bus bar:- 40x6 mm copper strip or adequate size PTs bus bar: Copper wire 8 SWG or 30x0.6mm copper flat strip to connect PT terminal or adequate size duly insulated by the monoplast tape (Including unloading/loading/transportation from store to site)
580Installation, testing and commissioning of PVC Copper wire flexible multi-strand of required size for secondary connections for CT wiring the minimum wire size shall be 4 mm2 (RYB) and for PT wiring minimum wire size shall be 2.5 mm2 (RYB). (Including unloading/loading/transportation from store to site)
581Installation, testing and commissioning of 3Ph, 3 Wire HT CT/PT operated Fully static Smart Tri-Vector Energymeters DLMS CompliantCategory 'C' with RS232 port for modem compatibility. 11kV/110V, Ph-Ph (3P,3W) metersfor measurement of different electrical parameters including Active Energy (kWh/ MWh), Reactive Energy (kVArh/MVArh), Apparent Energy (kVAh/ MVAh) etc. (make L&T, Secure,ABB) (Including unloading/loading/transportation from store to site)
582Laying, installation, testing and commissioning of 3 Core 11 kV Aluminium cable XLPE armoured 35 mm2 including cost of clamp for its fixingwhere ever required. (Including unloading/loading/transportation from store to site)
583Fixing of Cable termination kits suitable for 3 x 35 mm2 XLPE Cable(indoor/outdoor) (Including unloading/loading/transportation from store to site)
584Supply, Installation, Testing and commissioning of 11 KV Heavy duty 600 Amp Link Set
585Installation, Testing and commissioning of 11 KV Link Set (Including unloading/loading/transportation from store to site)
586Dismantling of old/damaged 11 KV Link Set and transportation of same to divisional stores
587Fixing & commissioning of available 11 KV Link Set excluding transportation charges
588Supply, Installation, Testing and commissioning of G.I Mukey for Shackle Insulators with bolt of (50x6)mm
589Installation, Testing and commissioning of G.I Mukey for Shackle Insulators with bolt of (50x6)mm (Including unloading/loading/transportation from store to site)
590Supply, Installation, Testing and commissioning of G.I Pole Collars for different sizes
591Installation, Testing and commissioning of G.I Pole Collars for different sizes
592Supply & Fixing of GI Wire 6 SWG & 8 SWG
593Fixing of GI Wire 6 SWG & 8 SWG (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally
594Supply & Fixing of GI Strip
595Fixing of GI Strip (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally
596Supply, installation, commissioning and Testing of MCB's \\"C\\" Curve
59710 A SP
59816 A SP
59932 A SP
60032 A TPN
601Installation, commissioning and Testing of MCB's \\"C\\" Curve (Material to be provided Departmentally)
60210 A SP
60316 A SP
60432 A SP
60532 A TPN
606Supply, installation, commissioning and Testing of MCCB's
60740/63/100 Amps,36 kA, 4P adjustable
608160 Amps, 36 kA, 4P adjustable
609200 Amps, 36 kA, 4P adjustable
610250 Amps, 36 kA, 4P adjustable
611400 Amps, 36 kA, 4P adjustable
612630 Amps, 36 kA, 4P adjustable
613Installation, commissioning and Testing of MCCB's (Material to be provided Departmentally)
61440/63/100 Amps,36 kA, 4P adjustable
615160 Amps, 36 kA, 4P adjustable
616200 Amps, 36 kA, 4P adjustable
617250 Amps, 36 kA, 4P adjustable
618400 Amps, 36 kA, 4P adjustable
619630 Amps, 36 kA, 4P adjustable
620Dismantling of MCCB's and transportation of same to divisional stores
621Dismantling, Repairing and reinstallation of MCCB's of various types/ratings
622Installation and Commissioning of available MCCB
623Boring by HDD Drilling (The job includes arrangement of Boring machine and other arrangements)
624Providing and laying of GI Pipe with required no of collars for road crossing including termination points.
625150 mm (6'')
626100 mm (4\\")
62750 mm (2\\")
628Providing and laying of HDPE Pipe
629180 mm Inner Dia 152 mm
630160 mm Inner Dia 148 mm
631120 mm Inner Dia 108 mm
63290 mm Inner Dia 78 mm
63350 mm Inner Dia 38 mm
634Supply and laying of HDPE Pipe including excavation, Back filling and laying
635Outer Dia 180 mm Inner Dia 152 mm
636Outer Dia 160 mm Inner Dia 148 mm
637Outer Dia 120 mm Inner Dia 108 mm
638Outer Dia 90 mm Inner Dia 78 mm
639Outer Dia 50 mm Inner Dia 38 mm
640Supply, intallation, testing & Commissioning of 11 kV Isolator, Double Break,3-pole, 630 Amp, horizontal mounting Type, with Earth Switch
641Intallation, testing & Commissioning of 11 kV Isolator, Double Break,3-pole, 630 Amp, horizontal mounting Type, with Earth Switch (including integeration with system, & loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally)
642Dismantling of 11 kV Isolator, Double Break,3-pole, 630 Amp, horizontal mounting Type, with Earth Switch and transportation of same to divisional stores
643Installation & commisioning of available 11 kV Isolator, Double Break,3-pole, 630 Amp, horizontal mounting Type, with Earth Switch including integeration with system,
644Providing and laying of Guard netting with Span length of 41 mtrs
645Providing and laying of Chemical Earthing (50mm dia G.I Pipe with Chemical bags) complete
646Supply and installation of LT Line Spacers
6473 P, 4 wire
6482 P, 3 wire
649Supply and installation of Aluminum Jointing Sleeves
65050 mm²
651100 mm²
652150 mm²
653Supply, installation, testing and commissioning of Bulb Holder
654E27(Screw type) Light Bulb Holder for Wall, 2 Amp 220-240 Volts Holder for Led/Electric Bulb
655E27(Screw type) Light Bulb pendant holder, 2 Amp 220-241 Volts Holder for Led/Electric Bulb
656Supply, Installation, testing and commissioning of Screw type LED bulbs
65730 watt
65815 watt
6599 watt
6607 watt
661Installation, testing and commissioning of Screw type LED bulbs (Material to be provided departmentally)
66230 watt
66315 watt
6649 watt
6657 watt
666Providing and commissioning of Switch Socket Combine 16 Amp
667Supply, installation, laying, testing and commissioning of
6681.0 sq.mm Copper Wire Multi Strand, Class 2, Heat Resistant & Flame Retardant
6691.5 sq.mm Copper Wire Multi Strand, Class 2, Heat Resistant & Flame Retardant
6702.5 sq.mm Copper Wire Multi Strand, Class 2, Heat Resistant & Flame Retardant
6714.0 sq.mm Copper Wire Multi Strand, Class 2, Heat Resistant & Flame Retardant
6722.5 mm 3 core Copper Cable, Class 2, Heat Resistant & Flame Retardant
673Transportation charges for material (including ST/PCC Poles/ACSR/DT etc) beyond 4 Km from store to different sites
674Hiring of the DG set of various capacities. The job includes loading, unloading and transportation to & fro. The fuel charges will be paid as per actual fuel price & consumption of DG Set.
67510 kVA
67625 kvA
67750 kVA
67863 kVA
679100 kVA
680Hiring of the vehicle (Pick Up etc) for whole day (fuel to be provided departmentally) for Carriage/Transportion of Material including loading and unloading from Divisional Stores to Different Sites or From one location to another Please Enable Macros to View BoQ information

Other Detail

Information Source https://jktenders.gov.in
Download FileName File Description File Size
Download 4a67767d-0ee2-4785-afb7-aa90d9a6ff38.html Tender Documents 0 KB
Download BOQ_1001524.xls Tender Documents 0 KB
Download Combineapprovedkpdcl.pdf Tender Documents 0 KB
Download SBD06.pdf Tender Documents 0 KB
Download Tendernotice_1 (6).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.