| 1 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES.(34.02)Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered),6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 2 | (i) a Wiring fan point (Without fan box) |
| 3 | (ii) Wiring light point |
| 4 | (iv) Wiring 6Amp. wall socket point |
| 5 | (vi) Wiring 16/20Amp. power plug control point |
| 6 | (viii) Wiring light point with double control switches. |
| 7 | (iii) Wiring call-bell point |
| 8 | 34.01 RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): (IX a) Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 9 | PVC INSULATED FR COPPER CONDUCTOR CABLES.(34.09) Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 10 | (i) Overall size 1 sq.mm (Un-sheathed) |
| 11 | (ii) Overall size 1.5 sq.mm (Un-sheathed) |
| 12 | (iii) Overall size 2.5 sq.mm (Un-sheathed) |
| 13 | (iv) Overall size 4 sq.mm (Un-sheathed) |
| 14 | 34.10 C XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- (ii) Overall size 10sq.mm (2Core) Un-armoured (On-Surface) |
| 15 | 34.12 PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 16 | (v) Heavy Gauge PVC Conduit Pipe 50mm dia.(On Surface) |
| 17 | (xi) Heavy Gauge PVC Conduit Pipe 32mm dia. (Flushed) |
| 18 | 34.12 (xxv) Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- (c) PVC Flexible Pipe 32 mm dia. |
| 19 | 34.16 A MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 20 | (ii) MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 21 | (iii) MCB Single Pole 40 amp. (10kA, Curve- C) |
| 22 | (viii) MCB Double Pole 50, 63amp. (10kA, Curve- C) |
| 23 | (xvi) MCB Four Pole 50, 63amp. (10kA, Curve- C) |
| 24 | 34.17 SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars,earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles andbonding to existing earth etc:- (xi) TP&N Vertical Double Door Distribution Board 12 way each |
| 25 | 34.16 B RCBO's: Supply and erection of RCBO (Residual Current Breaker Overload) for Earth leakage, overload and short circuit protection suitable for 240/415 volts 50 cycles AC supply with breaking capacity of 10kA as per IEC 61009 in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- (iii) RCBO Double Pole 40amp., Sensitivity 30mA |
| 26 | Providing and Fixing Chemical Earthing(copper type) with new Earthing Point,copper Wire including Testing and Labour Charges(2 METER) (Quotation) |
| 27 | Providing & Fixing Flood Light (120 W) (Quotation/market rate) |
| 28 | LED Tube Set 36 Watt (Quotation/market rate) |
| 29 | LED Tube Set 20 Watt (Quotation/market rate) |
| 30 | LED Tube Set 10 Watt (Quotation/market rate) |
| 31 | DISMANTLING WIRING POINTS & FITTINGS:Dismantling old wiring points including necessary repairs to wall etc:- (34.39) |
| 32 | (i) Fan, light or call bell point |
| 33 | (ii) Wall socket, power plug point Please Enable Macros to View BoQ information |