Indian Tenders

Tender Notice

TDR 55354498
Tendering Authority Military Engineer Services
Tender No 801247/E8
Tender ID 2026_MES_763525_1
Tender Brief Corrigendum : Tender For Provn Of Guest House At 16 Hect Land At Icgs Mayabunder.
City Diglipur
State Andaman And Nicobar Islands
Document Fees INR 1000 /-
EMD INR 260000.0 /-
Tender Value INR 1.80 Crore /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Provn Of Guest House At 16 Hect Land At Icgs Mayabunder.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 22-05-2026 Corrigendum1 Other 09-06-2026

Key Dates

Publish Date 22-05-2026
Last Date of Bid Submission 09-06-2026

Contact Information

Company Name Military Engineer Services
Contact Person HQ CE ANZ Sri Vijaya Puram
Address HQ CE ANZ Brichgunj Military Station Sri Vijaya Puram 744103

BOQ Items

Name of Work:- Provn of Guest House at 16 hect land at ICGS Mayabunder.
Sl. No. Item Description
1SCHEDULE ‘A’ PART-I(BUILDING & STRUCTURE WORKS)Details of prepriced schedule is given in tender documents.
2SCHEDULE \\"A\\" PART-II (EXCAVATION, EARTHWORK, SITE CLEARANCE & SITE DEVELOPMENT) Details of prepriced Schedule is given in tender documents.
3SCHEDULE \\"A\\" PART-III (INTERNAL ELECTRIC SUPPLY)Details of prepriced Schedule is given in tender documents.
4SCHEDULE \\"A\\" PART-IV (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
5SCHEDULE \\"A\\" PART-V (EXTERNAL WATER SUPPLY )Details of prepriced Schedule is given in tender documents.
6SCHEDULE \\"A\\" PART-VI (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
7SCHEDULE \\"A\\" PART-VII (ROAD/ PATH/ CULVERT) Details of prepriced Schedule is given in tender documents.
8SCHEDULE \\"A\\" PART-VIII (SEWAGE DISPOSAL)Details of prepriced Schedule is given in tender documents.
9SCHEDULE \\"A\\" PART-IX (AREA DRAINAGE)Details of prepriced Schedule is given in tender documents.
10SCHEDULE \\"A\\" PART-X (RETAINING WALL)Details of prepriced Schedule is given in tender documents.
11SCHEDULE \\"A\\" PART-XI (D G SET)Details of prepriced Schedule is given in tender documents.
12SCHEDULE \\"A\\" PART-XII (A C & REFRIGERATION)Details of prepriced Schedule is given in tender documents.
13SCHEDULE \\"A\\" PART-XIII (HOT WATER SUPPLY)Details of prepriced Schedule is given in tender documents.
14SCHEDULE \\"A\\" PART-XIV (RAIN WATER HARVESTING) Details of prepriced Schedule is given in tender documents.
15SCHEDULE \\"A\\" PART -XII (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col.' E ' signifies this fact only.
16Supply and fixing LED type security light fitting 1 x 25 watts pressure die cast housing with aerodynamically shaped body, high grade powder coating finish, good aesthetics and corrosive protection toughened glass & high power LEDs IP66 protection inlcuding mounting arrangements like bracket made out of galvanized iron tubing 'light grades' of suitable dia of pipe up to a length of 1.5m bent to shape fixed to wall with mild steel flat iron clamps 40 x 5mm duty painted and connecting with 1.5 Sqmm three core weather proof PVC cable copper conductor multistranded from terminal point to fitting complete all as specified and as directed.Make-: Crompton Cat No LSTS 25-CDL-M or equivalent in Philips/Bajaj.
17Supply and fixing vertical Distribution box TPN 4 Way, Double door complete all as specified and directed.Make-: Havells Cat No DHDPTVODRW04 or equivalent in Philips/Bajaj.
18Supply and fix refrigerator, electric driven (single phase), Whirlpool 5 Star frost free multi door refrigerator capacity 260 Litres all as specified and directed.
19S&F wall mounted type voltage stabilizer for automatic operation naturally air cooled indoor type 4 KVA capacity single phase- 220 Volts 50 HZ AC supply for voltage correction up to 170-260 Volts with accuracy of +/- 2.5% tolerance and with provision of protection relays including fixing accessories connection testing etc complete all as directed.
20S&F wall mounted type voltage stabilizer for automatic operation naturally air cooled indoor type 1 KVA capacity single phase- 220 Volts 50 HZ AC supply for voltage correction up to 170-260 Volts with accuracy of +/- 2.5% tolerance and with provision of protection relays including fixing accessories connection testing etc complete all as directed.
21Supply, installation and testing of portable type silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete DG set of capacity 20 KVA with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB IV norms including PCC foundation, single EB Automtic Mains Failure board for 3 phase dg set.
22(a) Prime Rating at rated rpm : (i) frequency -50 Hz (ii) Power Factor- 0.8 lagging (iii) Voltage 415V (iv) Governing Class (As per ISO 8528 Part-V-G2 (v) DG Set noise level at 1 meter- <75 dB(Genset with Canopy) (vi) Fuel Tank Capacity-up to 40 ltrs (vii)Electrical Battery Starting Voltage-12 Volts-DC.
23(b) ENGINE: (i) Rated output (prime Continuous rating as per ISO 8528-1-18.8kW/25.5kVA (ii) Cooling System-Liquid (iii) No.of Cylinder-03 Nos (iv) Cubic Capacity-1.65 ltrs (v) Bore x Stroke 86 x 94 mm (vi) Rated Speed-1500 RPM (vii) Aspiration-TA (viii) Lube Oil change Period-500 hrs (ix) Lube oil sump capacity (max)-5.95 ltrs. (x) Coolant Capacity( Engine+ Radiator)-5 Ltrs. Make :- Kirloskar Green. Direct Injection, water / Air Cooling Engine, 2 Cylinder, in-line, 4 Stroke, rated at 1500 RPM conforming to BS-5514 and having following specification: (i) In-line fule pump with Eletronic Governor for KVA.(ii) Turbocharger. (iii) Stinless steel Exhaust Flexible Coupling and Exhaust Pipe duly insulated with Glass Fire Wool and Plain GI sheet Cladding & Extended outside the building. (iv) Silencer (v) Radiator (vi) Collant Inhibitor. (vii) Plate type Lub Oil Cooler, (viii) Spin-On-Fillers-Coolant, Fuel, Fuel & Lub Oil. (ix) Dry type, Heavy Duty, Replaceable Paper Element Air Cleaner with Restricatin Indicator, (x) Flywheel Housing and Flywheel to suit Single Bearing Alternator (xi) Electical Strater Motor (xii) Battery Charging Alternator (xiii) 1 x 12 Volts Batteries, 88 Ah capacity with multistranded copper cable for connecting leads and terminals (xiv) First fill of Lub Oil.
24(c) ALTERNATOR: (i) Insulation Class-Class H. (ii)Alternator Efficiency (at 100% load)0.8 pf-88.6 (iii) Max Voltage Dip at Full Load 0.8 pf leg< 20% (iv) Max Time to build up rated voltage at rated RPM-<2 sec , provided engine reach the rated speed. Make :- Kirloskar Green (i) Self Excited & Sell Regulated (ii) Voltage Regulation 19% (ii) class insulation (iv) Salient Pole revolving Field, (v) Digital Automatic Voltage Regulator [part of FCC 13011] (vi) Standard Enclosure IP-23, (vii) Telephone interference Gactor-50 (viii) Total Harmonic Factor. Better than 2% (ix) Supplying power to variable electrical load for unlimited hours Prime power (FRP) is in with 150 8528. 10% over capacity for one hour every 12 Hours of operation and will be siutable for tropical condition.
25(d) Automatic Mains Failure Panel: 20KVA industrial, Automatic ON and OFF process. NOTE :- i) Including installation, commission and testing all parts. (ii) Prior approval by GE of the detailed specifications, wiring circuit diagram before placing order to firm.
26(e) ENGINE CONTROL WITH AMF PANEL : Standard AMF Control Panel along with DG Set Cubicle with CRCA Sheet and angle iron structure including following accessories (i) AMF controller-1 No (ii) MCCB, FP, 25 Amps-1 No with over load, short circuit protection (iii) Contactor, FP, 25 Amps capacity-2 Nos (iv) Microprocessor based LED type Multifunctional intelligent panel Meter for showing Current, Voltage, frequency, Power Factor, Energy Consumed, Speed, Temperature of Egine, Oil Level, Battery Voltage etc-1 No (v) Hooter Fault Notice (vi) Auxiliary Relays 12 Voltage DC operated with 2 Nos + 2 NC-6 Nos. (vii) Suitable Terminals-11 Nos (Viii) indicating Lamps for DG ON & LOAD ON\\"-6 Nos. (ix) Push Button Momentary Operated - 2 Nos (x) Emergency Stop - 1 No. (xi) Control Fuse 6/10 Amps-11 Nos (xii) Selector Switches 2P, 2 way, 16 Amps-2 (xiii) Selector Switches Spring Retum-1 Nos (xiv) Control Wiring with suitable size copper conductors with pre-printed ferules. (xv) Battery Charger 12 Volts, 10 Amps, SMPS Automatic Float cum Boost Charge - 1 Nos (xvi) Current Transformer 50/5, Copper -3 Nos.
27(f) FUEL TANK (i) Fuel Tank of suitable capacity for minimum 12 Hours run with provision for Supply and Return Lines, Level indicator, Drain Valve, Cleaning Cover Vent Pipe & Locking Device. (ii) MS Fuel Pipeline from Fuel Tank to FIP of suitable size. (iii) Fuel Tank shall be mounted/located outside the cubicle with suitable mounting with angle iron supports.
28(g) ACOUSTIC ENCLOSURE: (i) Desgned to meet stringent MOEF/CPCB norms 75 dBA @ 1 m at 75% load under free filed conditions. (ii) Air Inlent Louvers shall be designed to operate at rate load even at 50 c Air Inlet Temperature. (iii) Cubicle shall be power coated for long lasting service life and super finish with UV Resistant Powder Coating and shall withstand extreme environment Stainless steel hardware shall be used.
29(h) ACCESSORIES: (i) Periodical Maintenance Tools as per Manufacture (ii) Operational, Spare Parts, & installation Guidelines and Catalogue NOTE: Rate quoted is also deemed to be including the following: (i) Testing of DG set shall be carried out by the IEM in presence of the OEM Representative. (ii) Artificial load i.e. strip heaters of suitable capacity and Diesel required for testing shall be made available duing tst by the contractor. (iii) Extended terminals with tinned copper has to be provied for terminating the incoing & out going cable with suitbale Panel[Changeover Panel] all as specified as directed. (v) Provision of cable gland & Aluminium lugs of suitable size lugs for ACB's/MCCB's if required (Iv) /G cable shall be laid / connected to DG set Cubicle Panel to AMF Control for terminating the cable at both end.
30NOTE:- (i) Including istallatin, commission and testing all parts. (ii) Prior approval by GE of the detailed specifications, wiring circuit diagram before placing order to firm.
31Supply and laying of DWC (Double corrugated)< HDPE pipe ISI marked IS-14390 part-II, of oter dia 50mm and inner dia 38mm with smooth internal and profiedl externl surface for non pressure under ground cable including all connected accessories like coupler \\"O\\" ring etc. for protection of cable complete all as specified and directed by Engr-in-Charge
32Supply and fix LT junction box for street light, sheet moulding compound (SMC) type with hinged type door and locking arrangement, off white colour, of size 130 x 180 x 77mm (internal) Make:HENSEL comprising 6 Amps MCB, 01 No bakelite base neutral link and 01 No earthing terminal bolt and nut and connecting up cables with aluminium terminal lugs incl fixing arrangements all as specified and as directed.
33S&F medium grade GI pipe bracket 40mm bore of length not less than 1.20M, bent to shape and fixed to poles/ wall with two No MS flat clamps etc. duly painted with two coats of aluminium paint over a coat of zinc chrome primer complete all as specified and directed
34S&F 100 Amps On Load changeover switch I-O-II, Euroload changeover, 4 Pole,with ss enclosure complete all as specified and directed.
35M&L for RCC Septic tank for 25 users :-RCC Septic tank Conventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., with effective depth of 1.5 meter and overall depth of 3 meter complete all as shown on drawing CE/TD/2022/16 Sht 1/1 as directed and specified.
36Soakage well 1.5 M dia X 1.5 M effective depth :- M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of suitable size complete all as shown on drawing CE/TD/2022/17 Sht 1/1 as directed and specified. Please Enable Macros to View BoQ information

Other Detail

Information Source https://defproc.gov.in/nicgep/app
Download FileName File Description File Size
Download 97ca741f-5dfe-457e-b57c-406b66ba8457.html Tender Documents 0 KB
Download BOQ_855274.xls Tender Documents 0 KB
Download Drawings1.pdf Tender Documents 0 KB
Download Drawings2.pdf Tender Documents 0 KB
Download Tender.pdf Tender Documents 0 KB
Download Tendernotice_1 (1).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.