| 1 | Earth Work in excavation in Foundation Trenches in Ordinary soil (vide classification of soil item -B) and disposal of excavated earth as obtained to a distance upto50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I HALL AND ROOM COLUMN and COMMON TOILET COLUMN |
| 2 | Extra for earth work in hard soil as per specification & direction of engineer in charge (Vide classification of soilitem B) 50% item no-1 |
| 3 | Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted) 70% ITEM NO-1 HALL, C. Toilet |
| 4 | Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer In charge (Mode of measurementcompacted volume) |
| 5 | Providing and laying in position cement concete of soecified grade excluding the cost of centering andshuttering - All work up tp plinth level 1:4:8 (1 cement :4 coarse sand (Zone -III) :8 graded stoneaggregrate 40 mm normial size) |
| 6 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) All works uptp plinth level |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 9 | Providing Tor steel reinforcement as per approved design& drawing ITEM NO 6+7+8= 248.47*100=24847.00 =24.87 MT |
| 10 | Centering and shutteing including struting, propping etcand removal of form for Foundations, footings, bases for columns, etc for mass concrete |
| 11 | Suspended floors, roof , landings , balconies and accessplatform |
| 12 | Lintels, beams, plinth beams, girders, bressumers andcantilevers |
| 13 | Columns, Pillars, Piers, abutments, Posts and struts Column upto NGL |
| 14 | providing designation 75 B brickwork in C M ('1 :6 ) in foundation and Plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing. taxes and royalty all complete as per building specification and direction of E/l. |
| 15 | Providing Designation 100A B/W with Fly Ash Lime Brick (FALB) conforming to IS 12894-1990 (9\\"x4.5\\"x3\\") in cement mortar (1:6) in Superstructure with clean coarse sand of F.M. 2 to 2.5 including 10mm thick mortar joints,cost of screening, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 16 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. |
| 17 | Supplying fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both side decorative veneered with black board core bended with high quality phenol formal clehydes synihetic resin of standard make with Aluminium fittings :such as hinges, tower bolts, hendle, cleats and sand blocks and laxes all conrplete as pe building specrfication and direction of E/l. |
| 18 | Supplying fitting and fixing 35mm thick soltd core type decorative double leaf flush door sltutter with both side decorative veneered with black board core bended with high quality phenol formal clehydes synihetic resin of standard make with Aluminium fittings :such as hinges, tower bolts, hendle, cleats and sand blocks and laxes all conrplete as pe building specrfication and direction of E/l. |
| 19 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. |
| 20 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 21 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 22 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mmthickness |
| 23 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steeletc. as required. |
| 24 | Providing and fixing factory made single extruded WPC (Wood PolymerComposite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (SuspensionGrade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100gms) fabricated with miter joints after applying PVC solvent cement andscrewed with full body threaded star headed SS screws having minimumframe density of 750 kg/cum, screw withdrawal strength of 2200 N (Face)& 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulusof elasticity 900 N/mm2 and resistance to spread of flame of Class Acategory with property of being termite/borer proof, water/moistureproof and fire retardant and fixed in position with M.S hold fast/lugs/SSdash fasteners of required dia and length complete as per direction ofEngineer-In- Charge Frame size 65 x 125 mm |
| 25 | Supplying,frtting and fixing M.S. grill made of 20x6cmmM.S. flat as per approved design and drawing, properly fabrlcated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/1 |
| 26 | providing and laying, Doublecharge vitrified floor tiles in different sizes (thickness to be specified by lhe manufacturer) with water absorption less than 0.08% and conforming to lS 15622/ISO 13009 of approved make in all cotours and shades, laid on 20mm thick cement mortar 1 4 (1 cement:4 coarse sand) jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of tile600x600 mm |
| 27 | Providing and fixing granite 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for flooring, kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete atall levels. Granite of any colour and shade Area of slab over 0.50SQM |
| 28 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by theEngineer-in-Charge Polished Granite stone slab colour of Black, Cherry/RubyRed or equivalent |
| 29 | Providing edge moulding to 18 mm thick marble/granite stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 30 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc.complete. |
| 31 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer in-charge and finished smooth.Granite Stone of approved shade |
| 32 | Providing and laying 1st quality Ceramic glazed wall tiles thickness to be specified by the manufacturer) in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing polishing and cost of curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 33 | Providing and laying 25mm. thick kotah stone slab flooring of approved size, texture and colour over 19 mm thick base of lime morter (1:l:1) ( Lime putty : surkhi: coarse sand ) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to granolithic finish with approved quailty of carborandum stone including cost of curring, taxes and royalty all complete as per building specification direction of E/I. 600x600mm Size. |
| 34 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 35 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 36 | Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 37 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete |
| 38 | Finishing walls with Acrylic Smooth exterior paint of required shade,New work (Two or more coat applied @1.67 ltr/10 sqm over and including priming coat of exteriorprimer applied @ 2.20 kg/10 sqm) |
| 39 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and m anufacture, including applying additional coats wherever required, to achieveeven shade and colour. |
| 40 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately): |
| 41 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of leadfree uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extrudedprofiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and designduly reinforced with galvanized mild steel section made of required shape & size as perCPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (whereever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fastenersof minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 gradesleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plasticcaps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required)shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, includingdrilling of holes for fixing hardware and drainage of water etc. After fixing frame the gapbetween frame and adjacent finished wall shall be filled with weather proof silicon sealant overbacker rod of approved size and quality, all complete as per approved drawing conformingto CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcementand cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without highperformance coatings as per design requirements |
| 42 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse send : 6 graded stone aggregate 20 mm nominal size ) over 75 mm thick bed of dry brick ballast 40 mm nominal size ,wall rammed and consolidated and grouted with fine sand including necessary excavation, levelling & dressing & finishing the top smooth. |
| 43 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (basemetal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on bothside of the sheet and polyester top coat 15-18 microns. Sheet should have protective guardfilm of 25 microns minimum to avoid scratches during transportation and should be suppliedin single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixedusing self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete uptoany pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters andtrusses and including cutting to size and shape wherever required. |
| 44 | Providing valleys of 90 cm wide overall in plain G.S. sheet fixed with polymer coated J, or Lhooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete : 1.60 mm thick with zinc coating not less than 350 gm/m |
| 45 | Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymercoated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.12.4.1 0.80 mm thick with zinc coating not less than 275 gm/m² |
| 46 | 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibreconforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woventissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mmresin bonded glass wool backing. |
| 47 | Providing and fixing factory made single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising ofvirgin polymer of K value 58-60 (Suspension Grade), calcium carbonateand natural fibers (wood powder/ rice husk/wheat husk) and non toxicadditives (maximum toxicity index of 12 for 100 gms) having minimumdensity of 650 kg/cum and screw withdrawal strength of 1800 N (Face)& 900 N (Edge), minimum compressive strength 50 N/mm2, modulusof elasticity 850 N/mm2 and resistance to spread of flame of Class Acategory with property of being termite/borer proof, water/moisture proofand fire retardant and fixing with stainless steel butt hinges of requiredsize with necessary full body threaded star headed counter sunk S.Sscrews, all as per direction of Engineer-In- Charge.35 mm thick |
| 48 | Carriage Cement upto 8 KM |
| 49 | Carriage Sand upto 35 KM |
| 50 | Carriage Stone chips upto 8 KM |
| 51 | Carriage Bricks upto 8 KM |
| 52 | Metal av lead 20 K M |
| 53 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40 mm nominal outer dia .Pipes. |
| 54 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall 20 mm dia. nominal bore |
| 55 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall 25 mm dia. nominal bore |
| 56 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore |
| 57 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 58 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 59 | Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required :Single squatting plate with 5 litre P.V.C. automatic flushing cistern |
| 60 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern |
| 61 | Providing and fixing uplasticised PVC connection pipe with brass unions :30 cm length 15 mm nominal bore |
| 62 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete Semi rigid pipe 40 mm dia |
| 63 | Providing and fixing PTMT pillar cock of approved quality and colour.15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms |
| 64 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore |
| 65 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 110 mm diameter |
| 66 | Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 75 mm diameter |
| 67 | Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single tee with door 110x110x110 mm |
| 68 | Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend |
| 69 | Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single tee with door 75x75x75 mm |
| 70 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore. |
| 71 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. |
| 72 | Providing and fixing water closet squatting pan (European W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 73 | Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : |
| 74 | Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling, ramming the foundation trenches, removing roots of trees shurbs all complete as per approved design building specification and direction of E/I. |
| 75 | Extra for earth work in hard soil as per specification and direction ofE/I. (vide classfication of soil item - B) |
| 76 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume) |
| 77 | Providing designation 75Bwork in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.m. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials ranking out joints to 15mm depth, curing taxes and royalty all complete as per building specification and direction of E/I. |
| 78 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size) |
| 79 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns,etc. for mass concrete |
| 80 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 81 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders,bressumers and cantilevers |
| 82 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 |
| 83 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconiesand access platform |
| 84 | Providing Toe steel reinforcement of 10mm to 16mm dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL, TATA Steel, JSPL, Electro Steel Ltd. and VizalSteel) 10 mm dia |
| 85 | Providing Toe steel reinforcement of 10mm to 16mm dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL, TATA Steel, JSPL, Electro Steel Ltd. and VizalSteel) 12 mm dia |
| 86 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as perbuilding specification & direction of E/I |
| 87 | Bricks Lead = (1 K+7 P)8 km |
| 88 | SAND av.LEAD 10 K.M |
| 89 | Stone chips lead = 22 km |
| 90 | Carriage Cement upto 8 KM |
| 91 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. (a) From 0.00 M to 50.00 M below G.L. |
| 92 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. (b) From 51.0 M to125.00 M |
| 93 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. (c) From126.0 M to150.00 M |
| 94 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in charge.200 mm nominal size dia |
| 95 | Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge |
| 96 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia |
| 97 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp |
| 98 | Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages2 HP |
| 99 | Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes , all complete jobas per direction of E/I. |
| 100 | Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job asper direction of E/I. |
| 101 | Supply fitting and fixing lowering 40 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I. |
| 102 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 103 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 104 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 |
| 105 | Reinforced cement concrete work 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20 mmnominal size) |
| 106 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 107 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 108 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 109 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 110 | Steel reinforcement |
| 111 | Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 112 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 113 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 114 | 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) |
| 115 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:ew work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 116 | Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 117 | Carriage Cement upto 8 KM |
| 118 | Carriage Sand upto 35 KM |
| 119 | Carriage Stone chips upto 8 KM |
| 120 | Carriage Bricks upto 8 KM |
| 121 | Metal av lead 20 K M |
| 122 | Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box etc as required: Group A |
| 123 | Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box etc as required: Group B |
| 124 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required: 5/6 amps one way switch |
| 125 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required: 5/6 amp 3 pin socket outlet |
| 126 | Wiring for circuit/submain wiring alongwith earth wire with the 2 x 4 sq mm + 1x 4 sq mm earthwire of FR PVC insulated copper conductor, single core cable in surface /recessed PVC conduit as required |
| 127 | supplying & fixing suitable Gl box with modular plac & cover infront on surface of in recess, including providing & fixing 6 pin 15/16 Amps modular socket outlet & 15/16 Amps modular switch. Connection, painting. etc as required (for light plugs to be used in non residential buildings) |
| 128 | Wiring for circuit/submain wiring alongwith earth wire with the 2 x 2.5 sq mm 1x 2.5 sq mm earthwire of FR PVC insulated copper conductor, single core cable in surface /recessed PVC conduit as required. |
| 129 | Wiring for circuit/submain wiring alongwith earth wire with the 2 x 10 sq mm + 1x 6.0 sq mm earthwire of FR PVC insulated copper conductor, single core cable in surface /recessed PVC conduit as required. |
| 130 | Wiring for circuit/submain wiring alongwith earth wire with the 2 x 16 sq mm + 1x 6.0 sq imm earthwire of FR PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required. |
| 131 | Wiring for circuit/submain wiring alongwith earth wire with the 2 x 6 sq min + 1x 6.0 sq mm-earthwire of FR PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required. |
| 132 | Supplying and fixing 6 amps to 32 amps rating. 240 volt, 10kA 'C' series MCB suitable for inductive load of single pole in the existing MCB DB complete with connections. testing and commissioning etc, as required. |
| 133 | Supplying & Fixing brass batten/angle holder including connection etc. as required. |
| 134 | Supplying & Fixing 2 pin 5 amp ceiling rose oin the existing Junction box/wooden block including connection etc as required |
| 135 | Supplying & Fixing brass batten/angle holder including connection etc. as required. |
| 136 | S.LT C of 12W LED round down light rating reccess/surface mounted LED round/square shape down light luminarie with pressure die cast housing for single phase supply voltage. Luminane shall be confirm to IS: 10322 part-5/section-2 or IEC:62722 with all neccessary accessiories as required |
| 137 | Providing and fixing 25 x 5 min G.I. strip on surface or in recess for connecton etc as required |
| 138 | suppliying and fixing stepped type electronic fan regulator modular type) on the existing modular plate & switch box including connecton but excluding modular plate etc. as required |
| 139 | Supplying and fixing 40amps(DP MCB) rating, 240 volt, 10kA C series MCB suitable for inductive load of double pole in the existing MCB DB complete with connections, testing and commissioning etc, as required. |
| 140 | Supplying and fixiing of 16 way double door single pole & neutral, sheet steel, MCB distribution board, 240%, on surface/recess. complete with tinned coper bus bar, neutral bus bar earth bar, din bar, interconnections, powder painted including earthing, etc as required(but without MCB/RCCB/Isolator) |
| 141 | Supplying and fixing of 4 way single door single pole & neutral, sheet steel, MCB distribution board, 240V, on surface/recess, complete with tinned coper bus bar, neutral bus bar earth bar, din bar, interconnections. powder painted including earthing, etc as required( but without MCB/RCCB/Isolator) |
| 142 | Supplying and fixing 63 amps(DP MCB) rating, 240 volt, 10kA 'C' series MCB suitable for inductive load of double pole in the existing MCB DB complete with connections, testing and commissioning etc, as required |
| 143 | Earthing with G.I. earth pipe 4.5m long 40 mm dia including accessories and providing masonry enclosure with cover pipe having locking arrangement andd watering pipe etc with charcoal and salt as required |
| 144 | 10 sq mm 2 core PVC/XLPE insulated PVC sheathed Heavy Duty, armoured electrical cable with aluminium conductor for working voltage upto & including 1100 V (IS: 15554) |
| 145 | providing and fixing 200amp.capacity busbar chamber with 4 strips of length 300mm made of copper suitable for following capacity complete with all accessories including connection earthing the body etc. as required |
| 146 | providing and fixing 100amp capacity 4 pole ON-load panel mounted changeover switches in existing cubical panel board, making connection earthing the body etc. as required |
| 147 | Supply of 95 sq.mm, 3.5 core PVC/XLPE insulated PVC sheathed heavy duty armoured electrical cable with aluminium conductor for working voltage up to and including 1100volts is: 1554 |
| 148 | supplying and fixing 20 amp 240 volts SPN industrial type socket oulet with 2 pole and earth metal enclosed plug top alongwith 20 amps \\"C\\" chained metal cover for the socket out let and complete with connections, testing and commissioning etc, as required |
| 149 | Supply & fixing TPN main switch 200 Amp |
| 150 | laying at one number PVC insulated and PVC scheathed XLPE power cable of 1.1 KV grade of size upto 35 sq mm direct in ground in the same trench in 1 tier horizontal formation including excavation & refilling the trench as etc as required but excluding sand cushioning & Protective covering |
| 151 | supply & erection of RCC/PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on lop with including excavation & refilling etc as required, Above 8.0 m and upto 11.0 m |
| 152 | SITC of 70/72W LED street lighting luminarie with pressure the die cast housing and toughened glass cover(IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz Luminarie shall be confirm to 10:10322 ал-5/estion-3 and shall be complete with all neccssary accessories as required |
| 153 | Laying of one number PVC insulated and PVC sheathed XLPE power cable of 1.1 KV grade of size 15 sq mim direct in groundin the same trench in 1 tier hortzontal forma chabag excavation & relling the Vanches as required, but excluding sand cushioning & protective covering |
| 154 | Add GST @ 18% |
| 155 | Add Labour Cess @1% Please Enable Macros to View BoQ information |