| 1 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in any type of soil & removing from site complete all as specified & directed. |
| 2 | Excavation over area not exceeding 1.5m deep and getting out in any type of soil complete all as specified & directed. |
| 3 | Excavation over area exceeding 1.5 m & not exceeding 3 m deep and getting out in any type of soil complete all as specified & directed. |
| 4 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation or for shafts, wells, cesspits, manholes, pier holes not exceeding10 Sqm on plan and not exceeding 1.5 m in depth and getting out in hard & dense soil complete all as specified & directed. |
| 5 | Material & Labour PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundations fillings & mass concrete complete all as specified & directed. |
| 6 | Material & Labour treating the bottom / side / top surface of excavated / filled at the rate of 5 litres of emulsion per Sqm of surface area complete all as per specified & dirceted. |
| 7 | Material & Labour Hardcore of broken stone of gauge not exceeding 63 mm deposited, spread & levelled in layers not exceeding 15 cm thick watered and rammed to a true surface complete all as specified & directed. |
| 8 | Material & Labour providing RCC M-25 (Design Mix) using 20 mm graeded crushed stone aggregate as in foundations / footings including rafts, foundation beams, plinth beams, bases for columns and mass concrete complete all as specified & directed. |
| 9 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified & directed. |
| 10 | Material & Labour providing RCC M-25 (Design Mix) using 20 mm graeded crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified & directed. |
| 11 | M&L for formwork to sides of coloumns / pillars / posts / struts / piers and stanchions vertical or to batter complete all as specified & directed. |
| 12 | Material & Labour providing RCC M-25 (Design Mix) using 20 mm graeded crushed stone aggregate as in Beams, cantilevers, bressummers & lintels over 1.5m clear span complete all as specified & directed. |
| 13 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs also splays between floors and beams complete all as specified & directed. |
| 14 | Material & Labour providing RCC M-25 (Design Mix) using 20 mm graeded crushed stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified & directed. |
| 15 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified & directed. |
| 16 | Material & Labour for moorum / red bajri filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled and well rammed in true surface including watering complete all as specified & directed. |
| 17 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thickness complete all as specified & directed. |
| 18 | Removing earth or excavated material exceeding 50m upto 100 m lead and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed. . |
| 19 | M&L for PCC 1:2:4 type B2 using 40 mm graded stone aggreagate as in surface channel or drains complete all as specified & directed. |
| 20 | M&L for forming fair finished drain or channel upto 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified & directed. |
| 21 | M&L for 100 mm thick PCC 1:4:8 type D2 using 40 mm graded stone aggreagate as in sub base of flooring complete all as directed. |
| 22 | Material & Labour providing precast RCC 1:2:4 using 20 mm crushed stone aggregate as in landing, cover slab (man hole cover or drain cover), chajja, shelves set in cement mortar in 1:4 complete all as specified & directed. |
| 23 | Material & Labour Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed. |
| 24 | Material & Labour Mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with steel clips complete all as specified & directed. |
| 25 | Material & Labour for 75mm thick PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in plinth protection laid in alternate panels not less than 3 m in length, laid to slope 1:30 including forming joints 10 mm wide and upto full depth of PCC and filled with bitumen mastic (1:3) 1 part bitumen 85/25 and 3 parts of river sand finsihed top surface even & smooth without extra cement complete all as specified and directed. Note :-Rate is deemed to be inclusive of materials against forming & filling of joints. |
| 26 | S&F Roof trusses (framed work) trusses, purlins, crane / gantries, rails and fastening & heavy brackets in framing (using angle iron or channel or flat section or hollow sections ERW) including distance pieces, MS plates / gusset plates, cleats, hold fast etc. conforming to Gde of steel Fe 290 Gde E-165 complete all as specified & directed. |
| 27 | Material & Labour for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified & directed. |
| 28 | Supply & Fixing for pre-painted 0.5mm thick Gavalume Aluminium Zinc coating GI based corrugated steel sheet of any colour having tensile strength 550 MPa and AZ 150 grade as in roof covering/cladding to walls, fixed with self tapping screws of required size complete all as specified & directed. |
| 29 | Supply & Fixing for pre-painted 0.5mm thick Gavalume Aluminium Zinc coating GI based plain steel sheet of any colour having tensile strength 550 MPa and AZ 150 grade as in ridge / valley gutter, drip & straight flashing / cladding to walls, fixed with self tapping screws of required size complete all as specified & directed. |
| 30 | Material & Labour brick work with subclass ‘B’ bricks, straight or curved on plan exceeding 6m mean radius, built in CM 1:4 complete all as specified and directed. |
| 31 | Material & Labour brick work with subclass ‘B’ bricks, straight or curved on plan in half brick thick wall, built in CM 1:4 complete all as specified and directed. |
| 32 | Material & Labour 12mm thick sand face plaster with fine granular sand mixed with admixture (adhesive based) & pasted in wall surface with steel towel and plastered surface shall be finsished even & smooth on brick or concrete surfaces complete all as directed. |
| 33 | Material & Labour 15mm thick rendering on brick or concrete surfaces in CM 1:4 finished plastered surface even & fair complete all as specified and directed. |
| 34 | Material & Labour 10mm thick rendering on fair faces of brick or concrete surfaces in CM 1:4 finished plastered surface even & fair and applying 3 mm thick wall care putty of approved make apply putty with steel towel, rubbing with sand or emery paper of required grade to achive smooth surface for using finishing coat complete all as specified and directed. |
| 35 | Material & Labour 5mm thick rendering on fair faces of concrete surfaces on Ceilingin CM 1:3 finished plastered surface even & fair complete all as specified and directed. |
| 36 | Supply only Liquid water proofing compound ISI marked |
| 37 | Material & Labour preparion of new plastered surface of wall and applying two coats of weather coat exterior paint over and including one coat of cement alkali based primer complete all as specified & directed. |
| 38 | Material & Labour preparion of newly plastered surface of wall and applying two coats of oil bound distemper (Acrylic Emulsion) over one coat of primer of same make smooth complete all as specified and directed |
| 39 | Material & Labour preparion of newly plastered surface on Ceilingsand applying two coats of oil bound distemper (Acrylic Emulsion) over one coat of primer of same make smooth complete all as specified and directed |
| 40 | Supply & Fixing pressed steel door frame of size 105mmx60mm for doors with one or more rebates including necessary butt hinges, lock strike plate etc as per IS requirement complete all as specified & directed. |
| 41 | Supply & Fixing pressed steel door frame of size 125mmx60mm for doors with one or more rebates including necessary butt hinges, lock strike plate etc as per IS requirement complete all as specified & directed. |
| 42 | Supply & Fixing solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube fixed in opening as per specification & drawings complete all as specified & directed. |
| 43 | Supply & Fixing factory made solid PVC moulded door shutter with particle with wood board core 28-30 mm thick style with 2 / 4 / 6 raised panel design wit h2 mm thick moulded prelam PVC sheet on the front face & 2 mm thick palin colour PVC sheet on back face supply & fixing in frame at site as per specification & drawing complete all as specified & directed. |
| 44 | Supply & Fixing 30 mm thick single peice coloured ABS (Acrylonitrile Brutadine Styrene) coated PUF filled door shutters with PUF (Poly Unethane Foam) insulation of minimum density 40 Kg per Cum filled in between two ABS sheets of thickness 1.2 (minimum) border covered with insitu pasted ABS strips of width equal to thickness of door shutters, 1.2 mm thickness reinforced with two number 10 mm CTD bars, pre-embeded wit hwooden blocks of suitable sizes for receiving hinges tower bolt / sliding bolts tower rails handles etc with embossed pateren complete all as specified & directed. |
| 45 | Supply & Fixing factory made UPVC white colour casement (Openable) window area exceeding 1 Sqm & not exceeding 2 Sqm each made of extruded profile with wall thickness of 2.3 mm (± 0.2 mm) window profile with hollow section with multi chamber frame (60x58 mm), sash (60x73mm), T profile one vertical length in between two shutter (60x74 mm), glazing beads (35x20mm) will be mitered cut and fusion welded at all corners including drilling of holes for fixing hardware and making arrangement for drainage system of rain water, making arrangement of fixing of hardware EPDM gasket 1.2 mm thick, galvanuised steel frame (28x21.5mm) sash (31x27.5mm), T profile (27x17mm) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100 mm long fasteners, hardware (Casement handle made if zinc alloy whilt colour powder coated, butt hinges of zinc alloyed whilte colour powder coated, transmission gear made of mile steel with multi point locking system and including 5 mm thick tinted glass glazing with seclected quality glass complete all as specified & directed.Note : Rate quoted by bidder is includes cost of glass, beading, fixing accessories, necessary hardware. Net opening shall be measured for paymens. |
| 46 | Supply & Fixing Powder coated (minimum thickness of coating 50 micron) aluminium window / ventilator side hung type shutters (adequate track) without sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, necessary powder coated hardware ie. handles 150mm, 100mm barrel tower bolts, hinges 100mm type B-21, powder coated aluminum snap beading fixed with screws complete all as specified & directed.Note : Rate quoted by bidder is includes cost of 4 mm thick glass, snap beading, 6 mm thick fibre boards, SS wire mesh of 0.36 mm & fixing accessories, necessary hardware. Net opening shall be measured for paymens. |
| 47 | Material & Labour PCC 1:2:4 type B0 using 12.5mm crushed stone aggregate as in coping / fixing of hold fasts & filling in pressed steel door frame including necessary form work complete all as specified & directed. |
| 48 | Material & Labour 5 mm thick rubber sheet with fabric with fabric backing or insert and plain coloured of marbled textured topping, matt or glossey finished laid in floors fixed with approved adhesive complete all as specified & directed. |
| 49 | Material & Labour for 18-20 mm thick machine cut kota stone slab in flooring of size ( 550x550mm) laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the colour or shade of the stone slab including rubbing and polishing (mirror polishing) over and including 15 mm thick screed bed or bedding layer in CM 1:6 complete all as specified & directed. |
| 50 | Material & Labour 16-18 mm thick granite stone slab (of any type) of any size, table top, machine cut, duly polishing grinding / rounding outer / exposed edges of stone, moulding all outer / exposed edges / sharp corners, duly fixed in steps, window cills, cooking platforms and like including 20 mm thick screed bed or bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match the colour / shade of stone slab complete all specified & directed. |
| 51 | Supply & Fixing exposed frame seamless false ceiling system comprising with GI powder coated GI frame grid channel 0.55 mm thick with two un-equal flanges of 20 mm & 30 mm and web 27 mm fixed to surrounding wall using nylon rubber sleeves and screws @ 450 mm c/c, intermediate channel 0.9 mm thick having two equal flanges of 15 mm and web 45 mm suspended from soffits at approx 900 mm c/c with GI cleats and steel expansion fasteners wit h& including ceiling setion (not exceeding 1200 mm length) of 0.55 mm thick having kurled web of 50 mm and flanges 26 mm with lips of 10.5 mm fixed to the intermediate channel with concealing clips across the intermediate channel at 457 mm c/c including hangers 6 mm dia GI upto 1200 mm wire adjusted & fixed to roof slab by means of ceillings cleats made with GI flat 40x3 mm size 600 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete fixed 10 mm thick POP ceiling (Gypsum anhydrous boards) designer type of size 595x595mm over second class hard wood fillets fixed in ceiling frame work complete all as specified & directed. |
| 52 | M&L for cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10 cm girth & making good with cement mortar 1:4 complete all as specified & directed. |
| 53 | M&L for vitrified tiles 8-10 mm thick double charged (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, laid in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over & including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed. |
| 54 | M&L for Glazed ceramic colour tiles 300x450x6-7 mm thick, on vertical surfaces such as skirting, dados and risers to steps etc set and jointed in neat cement slurry and pointed in white or Coloured cement to match fixed over & including 10mm thick redering or backing layer in CM 1:4 on wall complete all as specified & directed. |
| 55 | Supply & fixing on aluminium door 4 mm thick selected quality sheet glass plain/figured in squares not exceeding 0.5 Sqm each pane complete all as specified & directed. |
| 56 | Supply & Fixing stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4 mm fixed with tinned tacks or steel wire or steel clips/ staples complete all as specified & directed |
| 57 | Supply & Fixing butt hinges medium weight cold rolled, mild steel and fixed 100 mm size fixed with steel screws complete all as specified & directed. |
| 58 | Supply & Fixing Stainless Steel handles cast type anodised 150 mm size fixed with steel screws complete all as specified & directed. |
| 59 | Supply & Fixing Stainless steel tower bolts 150 mm long, extruded section & fixed in position fixed with steel screws complete all as specified & directed. |
| 60 | Supply & Fixing 300 mm long Stainless Steel sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections complete all as specified & directed. |
| 61 | Supply & Fixing 600x450mm size and 4mm thick beveled edge looking mirror of selected quality glass, mounted on 4mm thick PVC board with and incl fixing accessories complete all as specified & directed. |
| 62 | Supply & Fixing Vitreous China wash down water closet pan (pedestal pattern) EWC, wall hang EWC premium quality white/Ivory colour (Closed pattern) including necessary accessories like rag bolts / gel gasket including health faucet steel chromium plated 1200 mm long flexible pipe including CP jet system with & including plastic seat cover matching colour complete all as specified & directed. |
| 63 | Supply & Fixing PVC low level flushing cistern 10 lts capacity with ball valve float and handle, syphonic action type including brackets and flush pipe of polythelene of low or high density or PVC 32 mm dia low level flushing cistern fixed in position complete all as specified & directed. |
| 64 | Supply & Fixing of premium quality vitreous china wash hand basin white/Ivory colour flat back of oval shape for counter type of size 550x400mm complete including CP swan neck pillar tap of best quality / necessary cutting and pinning in ends of brackets with and including wall brackets, PVC waste pipe of 750mm long, CP waste coupling of 32mm dia size fixed over & including granite top having rounding outer exposed edge fixed on walls complete all as specified and directed. |
| 65 | Supply & Fixing rotational moulded polyethylene cylindrical vertical with closed top water storage tank triple layered white colour 1000 Ltr capacity with connecting nipple, hoisted and fixed in position and making GI tubing inlet or outlet connection complete all as specified & directed. |
| 66 | Supply & Fixing 20 mm dia of Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iorn pipe and fixed in position (minium weight 20 mm-210 gms) complete all as specified & directed. |
| 67 | Supply & Fixing 20 mm bore Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed in position complete all as specified & directed. |
| 68 | Supply & Fixing 40 mm bore Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed in position complete all as specified & directed. |
| 69 | Drilling & tapping from existing CI water mains in position for making branch connection for 40 mm dia pipe including FI clamps etc complete all as specified & directed |
| 70 | Supply & Fixing vitreous China Urinal, Half stall type, white colour (flat back or corner type) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:3, screwing urinal to plug with & including 600 mm longbrass screw pointing around urinal back in cement (excluding flushing cistern) with mild steel brackets or steel fasteners, flush pipe, CP grating along with waste coupling & union for discharge pipe including waste pipe complete all as specified & directed. |
| 71 | Supply & Fixing 15 mm bore Galvanized Steel tubes, medium grade fixed to walls (with steel clamps or fixing clips) and ceilings or laid in floors, concealed or open including cutting / chasis of grooves including necessary fittings & connections complete all as specified & directed. |
| 72 | Supply & Fixing 20 mm bore Galvanized Steel tubes, medium grade fixed to walls (with steel clamps or fixing clips) and ceilings or laid in floors, concealed or open including cutting / chasis of grooves including necessary fittings & connections complete all as specified & directed. |
| 73 | Supply & Fixing 25 mm bore Galvanized Steel tubes, medium grade fixed to walls (with steel clamps or fixing clips) and ceilings or laid in floors, concealed or open including cutting / chasis of grooves including necessary fittings & connections complete all as specified & directed. |
| 74 | Supply & Fixing 40 mm bore Galvanized Steel tubes, medium grade fixed to walls (with steel clamps or fixing clips) and ceilings or laid in floors, concealed or open including cutting / chasis of grooves including necessary fittings & connections complete all as specified & directed. |
| 75 | Supply & Fixing of ringfit PVC (SWR) pipe of 110 mm nominal dia size, wall thickness of 3.5 mm, type-A, in any length, single socketed as per IS : 13592-1992 with latest amendment, having one end of the pipe as plain and other end as self socketed with an integral groove to hold the rubber gasket, with and including rubber tighten gaskets, ringfit sockets etc, complete pipe duly fixed to walls with FI clamps used as rain / waste water pipes including all fittings any size and pattern complete all as specified & directed. |
| 76 | Supply & Fixing 110 mm bore PVC (SWR) bends of any radius jointed with adhesive complete all as specified & directed. |
| 77 | Supply & Fixing 110 mm bore PVC (SWR) floor trap, jointing to waste pipe complete all as specified & directed. |
| 78 | Supply & Fixing 110 mm bore PVC (SWR) Gully trap, jointing to pipe setting and jointing with solvent cement or adhesive complete all as specified & directed. |
| 79 | Supply & Fixing PVC connection 15mm bore with PTMT nuts and 600 mm long complete all as specified & directed. |
| 80 | Supply & Fixing long body bib tap, 15 mm dia with wall flange made of cast copper alloy, chromium plated with capstan head handle or lever screwed down screwed for iron pipe or brass ferrule complete all as specified & directed. |
| 81 | Supply & Fixing stop cock / angle valve 15 mm dia fancy type made of cast copper alloy, chromium plated with crutch or butterfly handle or lever half or full turn, screwed bot ends for iron pipe or for unions complete all as specified & directed. |
| 82 | Supply & Fixing concealed stop valve 15 mm dia fancy type made of cast copper alloy, chromium plated with long shank with capstan head handle or lever half or full turn, screwed bot ends for iron pipe or for unions complete all as specified & directed. |
| 83 | Supply & Fixing 125 mm Brass chromium plated shower rose with or without swivel joints, including fixing of steel pipe or union and fixed complete all as specified & directed. |
| 84 | Supply & Fixing of 25 mm tubular towel rail 600 mm long D type between flange and wall bracket made of cast copper alloy chromium plated fixed to walls with suitable fasteners complete all as specified & directed. |
| 85 | Supply & Fixing SS grating of squre or round shape, overall size of 150x150mm with hinge type openable jali of 100 mm dia size with and including fixing in floor/nahani traps complete all as specified & directed. |
| 86 | Supply & Fixing PVC waste pipe 32 mm dia 700 mm long for wash hand basin or kitchen sink complete all as specified & directed. |
| 87 | Material & Labour water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane centre core 100mm micron HMHDPE outer film 20 micron each having thickness 3mm weight not less than 3Kg per Sqm as per manufacturer’s instructions laid with torch application complete all as specified & directed by Engineer-in-Charge with following course of action/description below:-(a) 10 mm thick plaster in CM 1:4 with WPC (liquid water proofing compound @ 200 ml per bag (50 Kg Bag)) will be applied over the roof slab (subjected to condition as mentioned in notes). After the plaster is cured the roof will be tested for water tightness by ponding with water for seven days for any seepage observed the rectification will be carried out by pressure grouting under the pressure of 5Kg per Sqcm using cement based grout. After the surface is repaired the slab will be tested for water tightness again before proceeding further treatment. |
| 88 | (b) Surface of roof, parapet and gutters, drain mouths etc over which water-proofing treatment is to be applied shall be cleaned of all foreign matter such as fungus, moss, dust etc by wire brushing and remove all loose dust particles. For cast iron drain outlets a groove shall be cut around to tuck in the treatment. Concrete angle-fillets shall be provided at junctions between roofs and vertical faces of walls (parapet and other walls) around obstacles such as pipes, chimney stacks etc and other similar situation to ease up about corners.(c) Bitumious based primer confiorming to IS: 3384 @ 0.3 Kg per Sqm to be applied on prepared surface, till the surface is propely impregnated. Please Enable Macros to View BoQ information |
| 89 | (b) Surface of roof, parapet and gutters, drain mouths etc over which water-proofing treatment is to be applied shall be cleaned of all foreign matter such as fungus, moss, dust etc by wire brushing and remove all loose dust particles. For cast iron drain outlets a groove shall be cut around to tuck in the treatment. Concrete angle-fillets shall be provided at junctions between roofs and vertical faces of walls (parapet and other walls) around obstacles such as pipes, chimney stacks etc and other similar situation to ease up about corners.(c) Bitumious based primer confiorming to IS: 3384 @ 0.3 Kg per Sqm to be applied on prepared surface, till the surface is propely impregnated. Please Enable Macros to View BoQ information |