| 1 | Excavation in Foundation in ordinary soil (loam, clay or sand) including lift upto 1.5 M and lead upto 50M filling watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and disposal of surplus earth upto a distance of 50M from centre of the foundation trenches. |
| 2 | Earth work filling |
| 3 | Concrete with cement, coarse sand & 40 mm nominal size40 mm stone ballast in proportion of 1:5:10 in foundations including supply of all materials, labour, T&P etc. required for proper completion of the work. |
| 4 | R.C.C. work with cement, coarse sand and 20 mm gauge stone ballast in proportion of (1:1.5:3) in Plinth Beam |
| 5 | R.C.C. work with cement, coarse sand and 20 mm gauge stone ballast in proportion of (1:1.5:3) in Column |
| 6 | R.C.C. work with cement, coarse sand and 20 mm gauge stone ballast in proportion of (1:1.5:3) in slab |
| 7 | Mild steel or iron in plain work such as in reinforced concrete or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage. Bend hooks and authorized overlapping shall be measured (@ 10% of Concrete) |
| 8 | 4.0 cm thick damp proof course with cemant approved c-sand 1:1.5 and including water proofing material as per |
| 9 | Ist class brick work in 1:6 cement & coarse sand mortar in foundation and plinth including supply of all materials, labour, T&P etc. required for proper completion of the work. |
| 10 | First Class brick work in 1:4cement and coarse sand mortar in super structure including necessary cutting and moulding of bricks as required and also including supply of materials, labour, T&P etc. required for proper completion of the work thickness of wall not be less than one brick. |
| 11 | 12mm thick plaster with cement mortar in proportion of 1:4 consisting of cement and coursesand (F.M. not less than 2.25 mm) over brick work including supply of all materials, labour, T&P etc. required for proper completion of the work. |
| 12 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 13 | Finishing wall with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied a 1.43 ltri 10 sqm over and including priming coat of exterior primer applied a 2.20 10 sqm) |
| 14 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement:4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 15 | Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. |
| 16 | Supply of 80mm. Thick zig zag Shaped mechanicaly compressed interlocking cement concrete pavers block manufactured by high pressure and controlled vibration machine having minimum 5mm. Thick topping cp cement mixed 20% marble powder the compressive strength of concrete paver blocks shall not be less than 30MPa. & 4.5Kg./No. and ISI marked and as per drawing and confiming IRC-SP-63-2004 including cost of material, labour, T&P etc. required for proper completion of work as directed by E/I. |
| 17 | Mild steel or iron work such as small size and section as per |
| 18 | Painting on iron work |
| 19 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: 2/21 (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over theRCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm Engineer-in-charge.of cement admixed with water proofing compound conforming to IS : 2645 and approved by(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.\\"All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 20 | Providing and fxing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished,machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment,epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high glossnish etc. complete at all levels. |
| 21 | saintaray fitting |
| 22 | Electrificatoin charge |
| 23 | Add 18 GST Above of coast Please Enable Macros to View BoQ information |