| 1 | Surface excavation n.exc (not exceeding) 30 cm deep and 15cm deep and getting out in soft/loose soil. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft loose soil. Complete all as specified. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. Complete all as specified. |
| 4 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point Complete all as specified. |
| 5 | M&L for PCC 1:4:8 type D-2 (40mm graded) as in fdn filling and mass concrete Complete all as specified. |
| 6 | M & L RCC M-30 (nominal mix) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 7 | M & L RCC M-30 (nominal mix) as in columns, pillars, piers, posts and struts complete all as specified and as directed. |
| 8 | M & L RCC M-30 (nominal mix) as in beams, tie beam, gable beam cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. |
| 9 | M & L RCC M-30 (nominal mix) as in chajjas complete all as specified and as directed. |
| 10 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter with rough finished surface flat complete all as specified and as directed. |
| 11 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions with square or rectangular rough finished surface complete all as specified and as directed. |
| 12 | Formwork to sides and soffits of floor or roof beams, tie beam, gable beam, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed. |
| 13 | Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed. |
| 14 | M & L for MS TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not les than 0.9 mm dia or securing with clips quality conforming to complete all as specified and directed. |
| 15 | M&L TMT bars 5 to 8 mm mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia as in stirrups complete all as specified and directed. |
| 16 | M&L precast cement concrete block masonry with solid block, exc 10cm in width in PCC type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:6) all as specified. |
| 17 | M&L for rendering 10mm thick on other than fair faces of brick work or concrete surfaces in CM 1:6 finished even smooth without using extra cement all as specified. |
| 18 | M&L for rendering 15mm thick cement plaster on fair faces of concrete block masnory in two layers, base layer 10mm thick in CM (1:6) and top layer 5mm thick in CM 1:4(with river sand) mixed with WPC as per manufacture' s instructions, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. Note :- WPC shall be measured and paid seperately Note : Water proofing compound shall be measured seprately. |
| 19 | Supply only Liquid water proofing compound |
| 20 | M&L preparing newly plastered surfaces of wall and applying two coats of oil emulsion distemper over a coat of primer complete all as specified & directed |
| 21 | M & L preparation of newly surfaces of wall for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as directed. |
| 22 | Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge |
| 23 | Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. |
| 24 | Powder coated aluminium grill of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge. |
| 25 | Supply only Sheet glass, 4.8 mm ordinary quality and glazing with oil putty in square in n.exc 0.5 sq.m in each pane complete all as specified and as directed |
| 26 | M&L for sand filling under floors, cushning under interlocking tiles or in foundations incl watering and consolidations complete all as specified and directed. |
| 27 | M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete as specified as directed. |
| 28 | M&L for PCC 1:4:8 type D-2, 100 mm thick using (40mm graded) as sub base Complete all as specified. |
| 29 | M&L for PCC 1:2:4 Type B-1 (using 12.5 mm graded aggregate), as in floor 40mm thick, with finishing concrete surfaces even and smooth using extra cemnet complete all as specified. |
| 30 | M & L aluminium dividing 38mm wide strips, 1.5mm thick, inserted in position,conform to design complete all as directed and as specified. |
| 31 | M&L for PCC 1:2:4 Type B-1 (using 12.5 mm graded aggregate), 40mm thick, with finishing concrete surfaces with spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green as in ramp complete all as specified. |
| 32 | M&L for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed. |
| 33 | S&F 2 mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with L or J type screw and washer in roof, wall etc complete all as specified. |
| 34 | M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed. |
| 35 | M & L aluminium wind tie of any size fixed with self tapping screws of size 50/75mm with integral EPDM washer in roof covering. |
| 36 | M & L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed. |
| 37 | M&L for 75mm thick plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate finished even and smooth without using extra cement as in plinth proteaction complete all as specified and directed. |
| 38 | Preparing new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer. |
| 39 | Steel rolling shutters, 1.25 mm lath thickness with gear operated type with bevel gear box and crank handle, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete all as specified and as directed. |
| 40 | Safety lever locks mild steel with 4 levers for rolling shutters |
| 41 | M & L hardcore of gauge n exc. 63mm, with broken stone aggregate deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified. |
| 42 | M&L for 100mm thick cement concrete 1:4:8 type D2 using 40mm graded stone aggregate in sub base in floors and paving ,laid in panels and finished even & fair compete. |
| 43 | M&L for 100mm thick plain cement concrete 1:2:4 type B-2 using 40mm graded crushed stone aggregate finished even and smooth without using extra cement as in plinth proteaction complete all as specified and directed. |
| 44 | Material & labour for sand filling under floor complete all as specified and directed. |
| 45 | M&L 80mm thick factory made colored mixed with pigment precast concrete interlocking paver block of grade M-40 confirming to IS 15658-2006 manufactured by vibratory process laid over sand cushioning complete all as specified & directed. |
| 46 | M & L for providing cement concrete with type B1 (20 mm graded stone aggregate ) as in coping complete all as specifed and directed. |
| 47 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point Complete all as specified. Please Enable Macros to View BoQ information |
| 48 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point Complete all as specified. Please Enable Macros to View BoQ information |