Indian Tenders

Tender Notice

TDR 55339445
Tendering Authority Rural Engineering Department
Tender No 3513/SE RED Ayodhya/Ayodhya/25-26 Dt 30/03/2026
Tender ID 2026_REDUP_1145316_1
Tender Brief Tender For Under District Ayodhya, Construction Work Of 250 Capacity Boys Hostel At Main C Us Of Acharya Narendra Development University Of Agriculture And Technology At District Ayodhya (U.P) ,Lot No 1
City Ayodhya
State Uttar Pradesh
Document Fees INR 2354 /-
EMD INR 3783000.0 /-
Tender Value INR 18.91 Crore /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Under District Ayodhya, Construction Work Of 250 Capacity Boys Hostel At Main C Us Of Acharya Narendra Development University Of Agriculture And Technology At District Ayodhya (U.P) ,Lot No 1

Key Dates

Publish Date 05-05-2026
Last Date of Bid Submission 25-05-2026
Tender Opening Date 25-05-2026

Contact Information

Company Name Rural Engineering Department
Contact Person SE RED Ayodhya Circle
Address SE RED AYODHYA CIRCLE, BADA RAMANA, REEDGANJ, AYODHYA

BOQ Items

Name of Work:- Under District Ayodhya, Construction Work Of 250 Capacity Boys Hostel At Main C us Of Acharya Narendra Dev University Of Agriculture And Technology At District Ayodhya (U.P) ,Lot No 1
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge, DSR 2.8.1
2Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials., DSR 2.26.1
3All kinds of soil, 2.26.1
4Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m, DSR 2.25
5Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift., DSR 2.25a
6Diluting and injecting chemical emulsion for POST CONSTRUCTIONAL anti-termite treatment, DSR 2.35
7Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:, 2.35.2
8With Chlorpyriphos/Lindane E.C. 20% with 1% concentration, 2.35.2.1
9Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:, DSR 2.35.3
10With Chlorpyriphos/Lindane E.C. 20% with 1% concentration, 2.35.3.1
11Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete., 2.27
12Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources), DSR 4.1.8
13Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources), DSR 4.10
14Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil., DSR 4.13
15Centering and shuttering including strutting, propping etc. and removal of form for :, DSR-5.9
16Foundations, footings, bases of columns, etc. for mass concrete., DSR-5.9.1
17Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc., DSR-5.9.2
18Suspended floors, roofs, landings, balconies and access platform., DSR-5.9.3
19Shelves (Cast in situ), DSR-5.9.4
20Lintels, beams, plinth beams, girders, bressumers and cantilevers, DSR-5.9.5
21Columns, Pillars, Piers, Abutments, Posts and Struts., DSR-5.9.6
22Stairs, (excluding landings) except spiral-staircases., DSR-5.9.7
23Weather shed, Chajjas, corbels etc., including edges, DSR-5.9.19
24Edges of slabs and breaks in floors and walls, DSR-5.9.16
25Under 20 cm wide, DSR-5.9.16.1
26Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured)., DSR-5.11
27Suspended floors, roofs, landing, beams and balconies (Plan area to be measured), DSR-5.11.1
28Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more, (DSR 5.22.6)
29Upto P.L, (a)
30Above P.L, (b)
31Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete., DSR-5.33
32Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
33All works upto plinth level., DSR-5.33.1
34Concrete of M25 grade with minimum cement content of 330 kg /cum, DSR-5.33.1.1
35All works above plinth level upto floor V level., DSR-5.33.2
36Concrete of M25 grade with minimum cement content of 330 kg /cum, DSR-5.33.2.1
37Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level.Concrete of M30 grade with minimum cement content of 350 kg /cum, DSR-5.33.2.2
38Add for using extra cement in the items of design mix over and above the specified cement content therein., DSR-5.35
39Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections., DSR-5.30
40Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand, (DSR .6.1.2)
41Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in 230 mm wall Cement mortar 1:6 (1 cement : 6 coarse sand), 6.4.2
42Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in 115 mm wall Cement mortar 1:4 (1 cement : 4 coarse sand), 6.4.1
43Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels., 8.2.2.1
44Granite stone slab of colour black, Cherry/Ruby red, 8.2.2
45Area of slab over 0.50 sqm, 8.2.2.2
46Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete., 8.4
47Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. Fixing Ceramic floor tiles with cement based high polymer modified quickset tile adhesive (Water based) conforming to IS: 15477,ANSI: A 118.4 ET, EN12004/ISO 13007: C2TE, in average 3mm thickness.Adhesive Make: Laticrete 315 plus/Capa/kerakoll, 8.31+11.43
48Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:, 9.21
4935 mm thick including ISI marked SS butt hinges with necessary screws ., 9.21.1
50Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters, 9.23
5125 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws, 9.21.3
52Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters, 9.23
53Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:, 9.21
54On both side, 9.22.1
5530 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places forfixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge., 9.122.2
56Extra for cutting rebate in flush door shutters, 9.26
57Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.With 2nd class teak wood beading 62X19 mm, 9.135.1
58Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge., 9.147.A4
59Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body., 9.147.A4
60Using R3 series with frame (98mm & above) x (40mm & above) & both glazed and fly screen sash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m)., 9.147.A4.2
61Ventilator Casement window single panel with or without fixed panel with S.S. 304 friction hinges as per size and weight of sash, single point locking zinc alloy (zamak) powder coated handles., 9.147.D1
62Using R1 series with frame (33mm & above ) x (35mm & above) & sash /mullion (33mm & above) x (50 mm & above). (Height upto 0.90 metre)., 9.147.D1.1
63Providing & fixing 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm)., 9.7.7.2
64Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378), 9.66
65125 mm, 9.66.1
66100 mm, 9.66.2
67Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378), 9.62
68300x16 mm, 9.62.1
69250x16 mm, 9.62.2
70Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378), 9.63
71250x10 mm, 9.63.1
72200x10 mm, 9.63.2
73Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete., DSR-9.101.1
74Single rubber stopper, i
75Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete., DSR-9.79.2
76Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge., DSR-9.170.1
77200 mm
78Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer., 10.15
79Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), 10.15.1
80Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6mm for diagonal braces and central cross piece, 10.5.2
81Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. asrequired.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works, 10.25.2
82Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mmflat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge., 10.31
83Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing therailing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steelmembers shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)., 10.28
84Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete., 10.16.1
85Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based highpolymer modified quick set tile adhesive (water based) conforming to IS : 15477, ANSI: A 118.4 ET, EN12004/ISO 13007: C2TE in average 6 mm thickness, including grouting of joints Adhesive make: Laticrete 315 plus/Capa/kerakoll, 11.49
86Size of Tile 600x600 mm, 11.49.2
87Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately)., 11.47
88Size of Tile 600x600 mm, 11.47.2
89Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :, 11.26
9025 mm thick, 11.26.1
91Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete., 11.27
92Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. Deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4 coarsesand) bedding in laying of floor tiles and jointing with grey cement slurry@ 3.3 kg/ sqm.Fixing Ceramic floor tiles with cement based high polymer modified quickset tile adhesive (Water based) conforming to IS: 15477,,ANSI: A 118.4 ET, EN12004/ISO 13007: C2TE in average 3mm thickness.Adhesive Make: Laticrete 315 plus/Capa/kerakoll, 11.37-11.42+11.43
93Cement concrete flooring 1:2:4 finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate, 11.3.1
9418mm thick Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement., 11.6.1
95Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge., 11.56
96Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent., 11.56.1
97Extra for pre finished nosing to treads of steps of marble stone., 11.24
98Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4coarse sand) :Light shade pigment using white cement, 11.19.1
99Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :, DSR-12.21
100In 75x75 mm deep chase, DSR-12.21.1
101Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete., DSR 12.22
102Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required., 12.5
103Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :, 12.51
104Ridges plain (500 - 600mm), 12.51.1
1056 mm cement plaster in ceiling of mix : 1:3 (1 cement : 3 fine sand), 13.16.1
10615 mm cement plaster on rough side of single or half brick wall of mix:, 13.5
1071:4 (1 cement: 4 coarse sand), 13.5.1
10812 mm cement plaster of mix :, 13.4
1091:6 (1 cement: 6 coarse sand), 13.4.2
11015 mm cement plaster of mix :, 13.5
1111:6 (1 cement: 6 coarse sand), 13.5.2
112Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof., 13.22
113Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm), 13.47.1
114Two coats wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour., 13.83.2
115Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre, 13.85.1
116Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete., 13.8
117Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :, 13.61
118Two or more coats on new work, 13.61.1
119Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/ pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-incharge.(Only weight of grill to be measured for payment)., 21.17
120Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of :, DSR- 22.1
121(i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound.
122(ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. (iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.
123Using rough kota stone., 22.1.1
124Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge :
125Using rough Kota stone, 22.2.1
126Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of:, DSR-22.3
127Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface., (i)
128IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface., (ii)
129IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area., (iii)
130IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/ sqm)., (iv)
131Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:, CPWD 22.7
132Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645-2003, IS:9103, ASTMC 494 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.Water proofing compound Make:- Mykarment/Pidlite/BASF, (i)
133Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs., (ii)
134After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge., (iii)
135Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep., (iv)
136The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :, (v)
137With average thickness of 120 mm and minimum thickness at khurra as 65 mm., DSR 22.7.1
138Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage., DSR 22.23.1
139For vertical surface two coats @ 0.70 kg per sqm per coat, 22.23.1
140For horizontal surface one coat @1.10 kg per sqm., 22.23.2
141Providing and fixing white vitreous china pedestal type water closet (EuropeantypeW.C.pan)with seat and lid,10litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete,including cutting and making good the walls and floors wherever required :, 17.2.1
142Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required, 17.1
143White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests, 17.1.1
144Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe andC.P.brass spreaders with brass union and G.I clamps complete,including painting of fittings and brackets, cutting and making good the walls and floors wherever required, 17.4.1
145Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-, 17.7.4
146(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer .
147Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the wallswherever required :, 17.1
148Kitchen sink without drain board610x510 mm bowl depth 200 mm, 17.10.2.1
149Providing and fixing HEP Nahni-trap of Indian make HCI 100x75mm 4 Kg, SOR Ch-22 Item-52
150Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge., 17.16A
151Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe32 mm dia, 17.28.2.1
152Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete., 17.31
153Providing and fixing soil, waste and vent pipes :, 17.35
154150 mm dia
155Centrifuggally cast iron(spun) socket & spigot (s&s)pipe as per IS 3989, 17.35
156100 mm dia, 17.35.1.2
157Centrifuggally cast iron(spun) socket & spigot (s&s)pipe as per IS 3989, 17.35.2.2
15875 mm dia, 17.35.2.2
159Hubless centrifugally cast (spun) iron pipesepoxy coated inside & outside IS:15905100 mm dia, 17.35.1.3
160Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes :, 17.36
16175 mm dia pipe, 17.36.1
162100 mm dia pipe, 17.36.2
163Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),including cost of cutting holes and making good the walls etc. :, 17.37
164For 100mm dia pipe, 17.37.1
165For 75 mm dia pipe, 17.37.2
166Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete., 17.38
167100 mm dia, 17.38.1
168Sand cast iron S&S as per IS - 3989, 17.38.1.2
16975 mm dia, 17.38.2
170Sand cast iron S&S as per IS - 3989, 17.38.2.2
171Providing and fixing plain bend of required degree:, 17.39
172100 mm dia, 17.39.1
173Sand cast iron S&S as per IS - 3989, 17.39.1.2
17475 mm dia, 17.39.2
175Sand cast iron S&S as per IS - 3989, 17.39.2.2
176Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete., 17.43
177100x100x100 mm, 17.43.1
178Sand cast iron S&S as per IS - 3989, 17.43.1.2
17975x75x75 mm, 17.43.2
180Sand cast iron S&S as per IS - 3989, 17.43.2.2
181Providing and fixing single equal plain junction of required degree :, 17.44
182100x100x100 mm, 17.44.1
183Sand cast iron S&S as per IS - 3989, 17.44.1.2
18475x75x75 mm, 17.44.2
185Sand cast iron S&S as per IS - 3989, 17.44.2.2
186Providing and fixing single unequal plain junction of required degree :, 17.48
187100x100x75 mm, 17.48.1
188Sand cast iron S&S as per IS - 3989, 17.48.1.2
189Providing and fixing single equal plain invert branch of required degree :, 17.5
190100x100x100 mm, 17.50.1
191Sand cast iron S&S as per IS - 3989, 17.50.1.2
19275x75x75 mm, 17.50.2
193Sand cast iron S&S as per IS - 3989, 17.50.2.2
194Providing and fixing sand cast iron S&S off sets as per IS: 1729, 17.53
195114 mm off sets, 17.53.2
196With 75 mm dia pipe, 17.53.2.1
197With 100 mm dia pipe, 17.53.2.2
198Providing and fixing terminal guard :, 17,56
199100 mm, 17,56.1
200Sand cast iron S&S as per IS - 3989, 17.56.1.2
20175 mm, 17.56.2
202Sand cast iron S&S as per IS - 3989, 17.56.2.2
203Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter :, 17.58
204100 mm, 17.58.1
20575 mm, 17.58.2
206Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :, 17.6
207100 mm inlet and 100 mm outlet, 17.60.1
208Sand cast iron S&S as per IS - 3989, 17.60.1.2
209100 mm inlet and 75 mm outlet, 17.60.1
210Sand cast iron S&S as per IS - 3989, 17.60.2.1
211Providing and fixing PTMT Bottle Trap for Wash basin and sink., 17.7
212Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms, 17.70.2
213Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge., 18.7
214Internal work - Exposed on wall
21520 mm nominal dia Pipes, 18.7.2
21625 mm nominal dia Pipes, 18.7.3
21732 mm nominal dia Pipes, 18.7.4
21840 mm nominal dia Pipes, 18.7.5
21950 mm nominal dia Pipes, 18.7.6
220Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with onestep CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge., 18.8
22115 mm nominal dia Pipes, 18.8.1
22220 mm nominal dia Pipes, 18.8.2
22325 mm nominal dia Pipes, 18.8.3
224Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge., 18.9
22565 mm nominal dia Pipes, 18.9.7
22680 mm nominal dia Pipes, 18.9.8
227C.P BRASS FITTINGS
228Providing and fixing C.P brass bib cock of approved quality :, 18.49
22915 mm nominal bore, 18.49.1
230BRASS FITTINGS
231Providing and fixing brass bib cock of approved quality :, 18.15
23220 mm nominal bore, 18.15.2
233Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :, 18.17
23425 mm nominal bore, 18.17.1
23520 mm nominal bore, 18.17.1A
23632 mm nominal bore, 18.17.2
23740 mm nominal bore, 18.17.3
23850 mm nominal bore, 18.17.4
239Providing and fixing gun metal non- return valve of approved quality (screwed end) :, 18.19
24025 mm nominal bore, 18.19.1
241Horizontal, 18.19.1.1
24250 mm nominal bore, 18.19.4
243Horizontal, 18.19.4.1
24465 mm nominal bore, 18.19.5
245Horizontal, 18.19.5.1
24680 mm nominal bore, 18.19.6
247Horizontal, 18.19.6.1
248Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support Including fittings & fixtures for tank shall be paid separately, 18.48A
249Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :, 18.22
250150 mm diameter, 18.22.2
251Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required., 1.10
252Group C, 1.10.3
253Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required., 1.11
254Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required, 1.14
2552 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire, 1.14.1
2562 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire, 1.14.2
2572 X 4 sq. mm + 1 X 4 sq. mm earth wire, 1.14.3
2584x 10 sqmm+ 2x 6 sqmm earth wire, 1.7.10
2594x 16 sqmm+ 2x 6 sqmm earth wire, 1.7.11
260Supply & fixing of following sizes of medium class PVC conduit along with accessories in surface / recessed including cutting the wall & making good the same in case of recessed conduit as required., 1.21
26125mm, 1.21.2
26232mm, 1.21.3
263Supplying and fixing of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required., 1.24
2645/6 Amps switch, 1.24.1
2652 way 5/6 Amp switch, 1.24.2
26615/16 Amp switch, 1.24.3
2673 pin 5/6 Amp socket outlet, 1.24.4
268Telephone socket outlet, 1.24.6
269TV antenna socket outlet, 1.24.7
270Bell push, 1.24.8
271Supplying and fixing of Stepped type 2 module electronic fan regulator on the existing modular plate & switch box including connections but excluding modular plate etc. as required., 1.25
272Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required., 1.26
273Supplying and fixing of following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required., 1.27
2741or 2 module (75mmx 75mm), 1.27.1
2753 module (100mmx 75mm), 1.27.2
2764 module (125mmx 75mm), 1.27.3
2778 module (125mmx 125mm), 1.27.4
278Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required., 2.2
279125 Amp, 16 KA,TP MCCB, 2.2.2
280Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator), 2.4
2818 way (4+24),Double door, 2.4.3
282Supplying and fixing of following ways surface/ recess mounting,vertical type, 415 V, TPN MCB distribution board of sheet steel,dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.), 2.5
2834 way (4+12), Double door, 2.5.1
284Supplying & fixing 5 amps to 32 amps rating 240/415 volts, 10 kA, \\"C\\" curve Miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required., 2.1
285Single Pole, 2.10.1
286Supply & fixing of single pole blanking plate in the existing MCB DB complete etc. as required, 2.11
287Supplying and fixing of following rating four pole 415 V MCB in the existing MCB DB complete with connections ,testing and commissioning etc as required., 2.13
28840A, 2.13.1
28963A, 2.13.2
290Supplying & Fixing of following rating double pole (single phase and neutral) 240 volts, Residual Current Circuit Breaker (RCCB), having a sensitivity current upto 30 milli-amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required., 2.14
29140 Amps, 2.14.2
29263 Amps, 2.14.3
293Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing., civil dsr-10.18
294Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required., 1.31
295Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required., 1.33
296Supplying and fixing brass batten/ angle holder including connection etc. as required., 1.34
297Installation, Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required., 1.35
298Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required., 1.38
299Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored), 1.48
300Extra for fixing the Louvers/ shutters complete with frame for exhaustfans of all sizes., 1.51
301Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required., 1.56
302Fixing of lightning conductor finial (single prong) withbase plate including holes etc. complete as required., 6.2
303Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc asrequired., 6.3
304Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor and external lighting complete as required. (For Horizontal run), 6.7
305Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface ofwall for lightning conductor complete as required. (For vertical run), 6.8
306Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required., 6.12
307Earthing with G.I. earth plate 600 mm X 600 mm X 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required., 5.4
308Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc.with charcoal/ coke and salt as required., 5.6
309Supply and laying of 25mm x 5mm G.I. strip from earth electrode directly in the ground as required complete in all respect., 5.11
310Supply and laying of 25mm x 5mm copper strip at 0.50 meter below ground as strip earth electrode including connection / terminating with nut ,bolt spring washer etc. jointing shall be done by overlaping and with 2 sets of brass nut bolt&spring washer spaced at 50mm), 5.8
311LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) Supplying, Installation, Testing & Commissioning ofLED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following bodymaterial with PMMA and prismatic diffuser andconstruction as per IS: 10322 with driver as per therequirement with Driver efficiency >85%, Operatingvoltage AC 140-270 Volt, frequency 50/60 hz,Operating temp range -5°C to 40°C, internal surgeprotection of 2.5 KV with Short & Open circuitprotection, THD < 10%, P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) ≤ 19, Flicker free (flickershould be below 5%), life time (LED, Driver &electrical circuitry), of minimum 50000 BurningHours with 70% of initial Lumen maintained tilllife ends, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (StandardDeviation Colour Matching) <3, Maximum powerconsumption should not more than the specifiedrating and Fixture shall be confirming to relevant BISstandards. Manufactures Word Mark/ NameEngraved/ Embossing/ Screen printing on housingComplete in all respect i/c external connectionswith 1.5 sq.mm FRLS/HFFR, PVC insulatedcopper conductor single core cable and earthing etc.as required with Minimum 5 year OEM warranty.System lumen efficacy ≥105 and <120 lm/Wattoutput. LM79 & LM80 Test report and all testingrequired for LED fixtures as per BIS shall besubmitted. Shape size and CCT shall be asapproved by Engineer-in-Chargeas perrequirement. (Thermal management: heat sink ofaluminiumhousing such that LED junctiontemperature shall not rise above 90°C) Powder coated die cast /Extruded aluminiumBody including trim, 8.1
3128 - 10 watt, 8.1.2
31312 -15 watt, 8.1.3
314LED Batten light (System lumen efficacy ≥120 <135 Im/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI ≥80, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 Im/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C)., 8.1
315Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
31624-26watt, 8.10.2
317LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt).Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 135 Im/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C)., 8.14
31836 watt, 8.14.9
319Brush Less Direct Current (BLDC) Fan without Remote, 9.2
320Supply, Installation, Testing and Commissioning ofceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. metal( Aluminiumalloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance asper IS : 374-2019), THD (Total Harmonic Distortion)less than 10%, suitable for operation with regulatorfor speed control and all remaining accessoriesincluding safety pin, nut bolts, washers, temperaturerise=75 0C (max.), insulation resistance more than 2mega ohm, suitable for 230 V, 50 Hz, single phase ACsupply, Ceiling Fan compliant to IS 374:2019 fan i/cexternal connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cableand earthing etc. as required.
3211200mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 210 CM/Min (Minimum), 9.2.3
322Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required., 12.3
323Above 4.5 Meter and upto 6.5 Meter, 12.3.1
324Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications., 28.2
325Two loop panel, 28.2.1.2
326Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required., 28.2.2
327Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required., 28.2.3
328Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required., 28.2.4
329Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required., 28.2.5
330Supplying, installation, testing & commissioning of fault isolator complete with base as required., 28.2.7
331Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required., 28.2.9
332Supplying, installation, testing & commissioning of addressable fire control module complete as required., 28.2.10
333Supplying, installation, testing & commissioning of addressable manual call point complete as required., 28.2.14
334Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required., 28.2.15
335Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required., 28.2.17
336Supplying, installation, testing & commissioning of fire fighter phone jack complete as required., 28.2.19
337Supplying & laying of 2x1.5 sqmm fire survival armouredcable, 600/1000V rated with annealed copper conductorhaving glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR)insulation and LSZH inner bedding,steel wire armouring &LSZH outer sheath complete as required.., 28.5.1
338Supplying, installation, testing & commissioning of 6 zone,voice alarm controller with USB, MP4 player (including 6zone button paging station) with seamless integration facilitywith main fire alarm panel for voice evacuation complete asrequired., 28.3.1
339Supplying, installation, testing & commissioning ofceiling/wall mounted loud speaker, 3/1.5 Watt in ABSenclosure complete as required, 28.3.4
340Supplying, installation, testing & commissioning of digitalaudio amplifier 50 Watt, 25V rms operating at 240 volt AC supply complete as required, 28.3.6
341Supplying, installation, testing & commissioning of Voicecommand keypad 6 zone, with microphone assemblyc omplete as required., 28.3.9
342Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and sizeincluding connections and interconnections etc. as required, 28.5.3
343speaker cable Two pair, 2-core, 1.5 sqmm, 28.5.3.2
344Supplying, installation, testing and commissioning of electric driven terrace pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump), 27.4
345900 lpm at 35 m Head, 27.4.1
346Poviding laying , testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding ,fitting like elbow, tees, flanges,tapers, nuts bolts , gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint required shade complete as required :, 27.7
34725 mm dia, 27.7.1
34880 mm dia, 27.7.6
349150 mm dia, 27.7.8
350Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required, 27.9
351Single headed Stainless steel, 27.9.2
35227.11 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts,washers, gaskets conforming following sizes as required :to IS 13095 of, 27.11
35380 mm dia, 27.11.4
354150 mm dia, 27.11.6
355Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber washers etc.as required : gasket, GI bolts, nuts,, 27.14
356150 mm dia, 27.14.7
357Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets conforming to IS 636 (type-A) as required :, 27.16
358Stainless Steel (Grade 304), 27.16.2
359Supplying and fixing first - aid Hose Reel with MS construction spray painted in post office red, conforming ti IS 884 complete with the following as required :, 27.17
360(a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced ) type-2 as per IS: 12585
361(b) 20 mm nominal internal dia gun metal globe valve & nozzle.
362(c ) Drum and brackets for fixing the equipments on wall.
363(d) Connections from riser with 25 mm dia stop gun metal valve & M.S. pipe and socket.
36430m, 27.17.1
365Supplying and fixing 63 mm dia, gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confoming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :, 27.18
366Stainless Steel (Grade 304), 27.18.2
367Supplying and fixing of fire brigade connection of cat iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :, 27.19.
3682-way -100 mm dia M.S. Pipe, 27.19.1
369Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required., 27.22
370Supply and fixing of CO2 type fire extinguisher 4.5kg capacity (ISI marked IS:2878 & TAC approved) complete with initial chargeb and wall bracket along with supply of all materials and labour for proper completion of work, UPPWD 1132
371Make Ansul/Aska/Minimax/Ceasefire
372Supply and fixing of Fire extinguishr ABC type 6.0 kg capacity (ISI marked IS: 15683 & TAC approved) complete with initial charge and wall bracket along with supply of all materials and labour for proper completion, UPPWD 1131A
373Make Firecon/LifeGuard/Fire Fit/Excell
374Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil., DSR 2.8.1
375Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift., DSR 2.25A
376Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete., DSR 2.27
377Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources), DSR 4.1.8
378Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :, DSR 2.35
379Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration, 2.35.3.1
380Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum, 5.33.1.1
381Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum
382Lintel Band, 5.33.2.1
383Slabs, 5.33.2.1
384Add for using extra cement in the items of design mix over and above the specified cement content therein., DSR 5.35
385Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand), DSR 6.1.2
386Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources), DSR 4.10
387Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil., DSR 4.13
388Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 ( 1 cement : 4 coarse sand), DSR 6.4.1
389Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more., DSR 5.22.6 & 5.22A.6
390Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:, DSR 9.21
39135 mm thick including ISI marked Stainless Steel butt hinges with necessary screws, 9.21.1
392Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured)., 9.23
393Mild steel or iron work
394Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works, DSR-10.25.2
395Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works, DSR-10.25.2
396Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works, DSR-10.25.2
397Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge., DSR-10.31
398Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes, DSR 10.30.1
39912 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand), DSR 13.4.2
40015 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement: 6 coarse sand), DSR 13.5.2
40115 mm cement plaster in single coat on plinth 1 cement: 4 course sand in plinth., DSR 13.5.1
402Add for plaster groove in plastered surface or moulding to R.C.C. projections., DSR 5.30
403Making drip course in sun shade or facia as per direction of Engineer incharge including supply of all materials, labour T & P etc for proper completion of the work., DSR 5.30
404Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate, DSR 11.3.1
405Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, ANSI: A 118.4 ET, EN12004/ISO 13007: C2TE in average 6 mm thickness, including grouting of joints Adhesive make: Laticrete 315 plus/Capa/kerakollSize of Tile 600x600 mm, DSR 11.49.2
406Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. Fixing Ceramic floor tiles with cement based high polymer modified quickset tile adhesive (Water based) conforming to IS: 15477,,ANSI: A 118.4 ET, EN12004/ISO 13007: C2TE in average 3mm thickness.Adhesive Make: Laticrete 315 plus/Capa/kerakoll, DSR 11.37+11.43-11.42
40725 mm thick Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :, DSR 11.26.1
408Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm), DSR 13.47.1
409Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre, DSR 13.41.1
410Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete., DSR 13.80
411Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture, DSR 13.48.3
412Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture, DSR 13.48.2
413Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
414(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
415(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm., DSR 22.7.1
416Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm, 9.96.1
417Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
418300x10 mm., 9.97.1
419Providing and fixing Stainless Steel handles, approved quality & make with necessary screws etc all complete. : 125 mm., DSR 9.165.1
420Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required, 17.1
421White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests, 17.1.1
422Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-, 17.7.4
423(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer .
424Providing and fixing HEP Nahni-trap of Indian make HCI 100x75mm 4 Kg, SOR Ch-22 Item-52
425Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe32 mm dia, 17.28.1
426Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm, 17.32.2
427Providing and fixing soil, waste and vent pipes :, 17.35
42875 mm dia, 17.35.2
429Centrifuggally cast iron(spun) socket & spigot (s&s)pipe as per IS 3989, 17.35.2.2
430Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes :, 17.36
43175 mm dia pipe, 17.36.1
432100 mm dia pipe, 17.36.2
433Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),including cost of cutting holes and making good the walls etc. :, 17.37
434For 100mm dia pipe, 17.37.1
435For 75 mm dia pipe, 17.37.2
436Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete., 17.38
437100 mm dia, 17.38.1
438Sand cast iron S&S as per IS - 3989, 17.38.1.2
43975 mm dia, 17.38.2
440Sand cast iron S&S as per IS - 3989, 17.38.2.2
441Providing and fixing plain bend of required degree:, 17.39
442100 mm dia, 17.39.1
443Sand cast iron S&S as per IS - 3989, 17.39.1.2
44475 mm dia, 17.39.2
445Sand cast iron S&S as per IS - 3989, 17.39.2.2
446Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete., 17.43
447100x100x100 mm, 17.43.1
448Sand cast iron S&S as per IS - 3989, 17.43.1.2
44975x75x75 mm, 17.43.2
450Sand cast iron S&S as per IS - 3989, 17.43.2.2
451Providing and fixing single equal plain junction of required degree :, 17.44
452100x100x100 mm, 17.44.1
453Sand cast iron S&S as per IS - 3989, 17.44.1.2
45475x75x75 mm, 17.44.2
455Sand cast iron S&S as per IS - 3989, 17.44.2.2
456Providing and fixing single unequal plain junction of required degree :, 17.48
457100x100x75 mm, 17.48.1
458Sand cast iron S&S as per IS - 3989, 17.48.1.2
459Providing and fixing single equal plain invert branch of required degree :, 17.5
460100x100x100 mm, 17.50.1
461Sand cast iron S&S as per IS - 3989, 17.50.1.2
46275x75x75 mm, 17.50.2
463Sand cast iron S&S as per IS - 3989, 17.50.2.2
464Providing and fixing sand cast iron S&S off sets as per IS: 1729, 17.53
465114 mm off sets, 17.53.2
466With 75 mm dia pipe, 17.53.2.1
467With 100 mm dia pipe, 17.53.2.2
468Providing and fixing terminal guard :, 17.56
469100 mm, 17.56.1
470Sand cast iron S&S as per IS - 3989, 17.56.1.2
47175 mm, 17.56.2
472Sand cast iron S&S as per IS - 3989, 17.56.2.2
473Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :, 17.6
474100 mm inlet and 100 mm outlet, 17.60.1
475Sand cast iron S&S as per IS - 3989, 17.60.1.2
476100 mm inlet and 75 mm outlet, 17.60.1
477Sand cast iron S&S as per IS - 3989, 17.60.2.1
478Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge., 18.7
479Internal work - Exposed on wall
48020 mm nominal dia Pipes, 18.7.2
481BRASS FITTINGS
482Providing and fixing brass bib cock of approved quality :, 18.15
48315 mm nominal bore, 18.15.1
484Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :, 18.17
48520 mm nominal bore, 18.17.1A
486Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support Including fittings & fixtures for tank shall be paid separately, 18.48A
487Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required., 1.10
488Group C, 1.10.3
489Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required, 1.14
4902 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire, 1.14.1
4912 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire, 1.14.2
492Supply & fixing of following sizes of medium class PVC conduit along with accessories in surface / recessed including cutting the wall & making good the same in case of recessed conduit as required., 1.21
49325mm, 1.21.2
494Supplying and fixing of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required., 1.24
4955/6 Amps switch, 1.24.1
4963 pin 5/6 Amp socket outlet, 1.24.4
497Telephone socket outlet, 1.24.6
498TV antenna socket outlet, 1.24.7
499Supplying and fixing of Stepped type 2 module electronic fan regulator on the existing modular plate & switch box including connections but excluding modular plate etc. as required., 1.25
500Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required., 1.26
501Supplying and fixing of following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required., 1.27
5021or 2 module (75mmx 75mm), 1.27.1
5038 module (125mmx 125mm), 1.27.4
504Supplying & fixing 5 amps to 32 amps rating 240/415 volts, 10 kA, \\"C\\" curve Miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required., 2.1
505Single Pole, 2.10.1
506Supply & fixing of single pole blanking plate in the existing MCB DB complete etc. as required, 2.11
507Supplying & Fixing of following rating double pole (single phase and neutral) 240 volts, Residual Current Circuit Breaker (RCCB), having a sensitivity current upto 30 milli-amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required., 2.14
50840 Amps, 2.14.2
509Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing., civil dsr-10.18
510Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required., 1.31
511Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required., 1.33
512Supplying and fixing brass batten/ angle holder including connection etc. as required., 1.34
513Installation, Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required., 1.35
514Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored), 1.48
515Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required., 1.56
516Earthing with G.I. earth plate 600 mm X 600 mm X 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required., 5.4
517Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc.with charcoal/ coke and salt as required., 5.6
518Supply and laying of 25mm x 5mm G.I. strip from earth electrode directly in the ground as required complete in all respect., 5.11
519Supply and laying of 25mm x 5mm copper strip at 0.50 meter below ground as strip earth electrode including connection / terminating with nut ,bolt spring washer etc. jointing shall be done by overlaping and with 2 sets of brass nut bolt&spring washer spaced at 50mm), 5.8
520LED Batten light (System lumen efficacy ≥120 <135 Im/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI ≥80, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 Im/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C)., 8.1
521Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
52224-26watt, 8.10.2
523Brush Less Direct Current (BLDC) Fan without Remote, 9.2
524Supply, Installation, Testing and Commissioning ofceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. metal( Aluminiumalloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance asper IS : 374-2019), THD (Total Harmonic Distortion)less than 10%, suitable for operation with regulatorfor speed control and all remaining accessoriesincluding safety pin, nut bolts, washers, temperaturerise=75 0C (max.), insulation resistance more than 2mega ohm, suitable for 230 V, 50 Hz, single phase ACsupply, Ceiling Fan compliant to IS 374:2019 fan i/cexternal connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cableand earthing etc. as required.
5251200mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 210 CM/Min (Minimum), 9.2.3
526Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil., 2.8.1
527Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete., 2.27
528Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources), 4.1.8
529Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum, 5.33.1.1
530Add for using extra cement in the items of design mix over and above the specified cementcontent therein., 5.35
531Centering and shuttering including strutting, propping etc. and removal of form for :, 5.9
532Foundations, footings, bases of columns, etc. for mass concrete, 5.9.1
533Lintels, beams, plinth beams, girders, bressumers and cantilevers, 5.9.5
534Columns, Pillars, Piers, Abutments, Posts and Struts, 5.9.6
535Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more., 5.22.6 & 5.22A.6
536Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern., 16.91.2
537Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture, 13.48.3
538Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes., 12.41
539110 mm diameter, 12.41.2
540Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete., 12.43
541110 mm, 12.43.2
542Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion., 12.42
543Bend 87.5°, 12.42.5
544110 mm bend, 12.42.5.2
545Shoe (Plain), 12.42.6
546110 mm Shoe, 12.42.6.2
547Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams., 12.44
548Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes, 10.16.1
549Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required., 12.5
550Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :, 12.51
551Gutter (600 mm over all girth), 12.51.6
552Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil., 2.8.1
553Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources), 4.1.8
554Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum, 5.33.1.1
555Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum, 5.33.2.1
556Add for using extra cement in the items of design mix over and above the specified cement content therein., 5.35
557Centering and shuttering including strutting, propping etc. and removal of form for :, 5.9
558Foundations, footings, bases of columns, etc. for mass concrete, 5.9.1
559Lintels, beams, plinth beams, girders, bressumers and cantilevers, 5.9.5
560Columns, Pillars, Piers, Abutments, Posts and Struts, 5.9.6
561Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more., 5.22.6 & 5.22A.6
562Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works, 10.25.2
563Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand), 6.1.2
564Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) 230mm wall, 6.4.2
565Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) 115mm wall, 6.4.2
56612 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand), 13.4.2
56715 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement: 4 coarse sand), 13.5.1
568Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm), 13.47.1
569Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete., 13.8
570Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture, 13.48.3
571Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches., 2.8.1
572Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors., 4.1.8
573Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement.All works upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum, 5.33.1.1
574Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shallbe payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design themix or bear the cost of extra cement.All works above plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum, 5.33.2.1
575P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks., 5.22.6
576Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand), 6.1.1
57715 mm cement plaster on rough side of single or half brick wall at plinth lvl of mix:1:4 (1 cement: 4 coarse sand), 13.5.1
578Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete., 13.8
579Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby redArea of slab upto 0.50 sqm, 8.2.2.1
580Mild steel or iron work in heavy sizes such as trusses built up gates, door frames, record racks, roof work gates etc. wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing., 10.25.2
581Painting or varnishing work in small areas or new wood work with one coat upto one square metre of ready mixed priming paint and one coat of approed superior quality ready mixed paint or varnish including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used should fonfirm the ISI no. 103-1950 (M.S. works), 13.62.1
582Centering and shuttering including strutting, propping etc. and removal of form for
583Foundations, footings, bases of columns, etc. for mass concrete, 5.9.1
584Columns, Pillars, Piers, Abutments, Posts and Struts, 5.9.6
585Earth work in excavation in trenches or drains(not exceeding 1.5m in width or 10 sqm on plan) including dressing of side sand ramming of bottoms, lift upto 1.5 m,including getting out the excavated soil and disposal of surplus excavated soil as directed,with in alead of 50 m., 2.8.1
586Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors., 4.1.8
587Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering-All work upto plinth level.
588(a) 1:2:4 (1 cement : 2 course sand : 4 graded stone aggregate 20 mm nominal size ) 4.1.3, 4.1.3
589Providing and fixing T-iron frames for doors,windows and ventilators of mild steel Tee-sections,joints mitered and welded with 15*3mm lugs 10 cm long embededded in cement concrete blocks 15*10*10 cm of 1:3:6 ( 1 cement : 3 course sand :6 graded stone aggregate 20 mm nominal size ) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary but hinges and screws and applying a priming coat of approved steel primer. (10.13.1), 10.13.1
590ANGLE IRON 90*90*6 mm
591T-SECTION 50*50*6
592HOLD FAST 40*6 FLAT
593G.I. Pipe (80 MM DIA) 18.12.8, 18.12.8
594Prepration and consolidation of sub grade with power road roller of 8 to12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead up to 50 meters. DSR 16.1, 16.1
595Earth work in excavation. (DSR-2.8.1), 2.8.1
596Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-III (size range 26.5 mm to 0.075 mm ) having CBR Value-20DSR-16.78.3, 16.78.3
597Construction of granular sub base by providing close graded material conforming to specifications , mixing in mechanical mix plant at OMC , carriage of mixed material by ippers to work site, For all leads & lifts , spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density , complete as per specification and directions of engineering - charge with material conforming to grade II (size range 53mm to 0.075 mm ) having CBR value 25.DSR-16.78.2, 16.78.2
598Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineerin- charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars tobe paid separately). DSR-16.43, 16.43
599B/W in Toe wall (1 cement : 4 coarse sand )DSR-6.1.1, 6.1.1
600Cement plaster 1:3 (1 cement :3 coarse sand ) finished with a floating coat of neat cement 20 mm cement plaster. DSR-13.9.2, 13.9.2
601Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared., DSR-2.31
602Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches., DSR-2.8.1
603Prepration and consolidation of sub grade with power road roller of 8 to12 tonne capacity after excavating earth to an average of 22.5 cm depth , dressing to camber and consolidating with road roller including making good undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead up to 50 meters., DSR 16.1
604Construction of granular sub base by providing close graded material conforming to specifications , mixing in mechanical mix plant at OMC , carriage of mixed material by ippers to work site, For all leads & lifts , spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density , complete as per specification and directions of engineering - charge with material conforming to grade II (size range 53mm to 0.075 mm ) having CBR value 25., DSR. 16.78.2
605Construction of granular sub base by providing close graded material conforming to specifications , mixing in mechanical mix plant at OMC , carriage of mixed material by ippers to work site, For all leads & lifts , spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density , complete as per specification and directions of engineering - charge with material conforming to grade III (size range 26.5mm to 0.075 mm ) having CBR value 20., DSR. 16.78.3
606Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath,parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern., DSR-16.91.2
607Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil., DSR 2.8.1
608Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources), DSR 4.1.8
609Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand), DSR 6.1.2
610Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster., DSR 13.9.2
611Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster., DSR 13.9.2
612Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate, DSR 11.3.1
613Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100 mm c/c on both ways, neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick, 100 mm wide MS sheet duly painted over priming coat, reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc including cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge., DSR 16.93
614Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
615In all kind of soil, DSR 2.8.1
616Extra additional lift above 1.5 m, DSR 2.26.1
617Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominalsize derived from natural sources), DSR 4.1.3
618Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand), DSR 6.1.2
619Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster., DSR 13.9.2
620Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M25 grade with minimum cement content of 330 kg /cum All works upto plinth level, DSR 5.33.1.1
621Add for using extra cement in the items of design mix over and above the specified cement content therein., 5.35
622Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more., DSR 5.22.6 & 5.22A.6
623Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars., DSR 19.15.1
624Providing and fixing 150 mm S.C.I. tee at the inlet and outlet of septic tank., DSR 7087
625Providing & fixing 75mm dia vent pipes., DSR 17.35.2.2
626Providing & fixing of 75mm dia cast iron terminal guard., DSR 17.56.2.2
627Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality., DSR
628Rectangular shape 600x450 mm internaldimensions, 19.19.2.2
629Earth work in excavation
630DSR 2.8.1
631Depth above 1.50 to 3.0 Mtr.
632DSR 2.26.1
633P.C.C. in Foundation
634DSR 4.1.8
6351st Class B/W in foundation
636DSR 6.1.2
637R.C.C. work (1:1.5:3)
638DSR 5.3
639SHUTTERING IN SLAB
640DSR 5.9.3
641M.S. work in R.C.C.
6425.22.6
643Providing & filling of brick bat inside of upper layer in soak pit.
644DSR 0362
645Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil., 2.8.1
646Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
647from Lvl. 1.5 Mt.m to 3.0 Mt, 2.26.1
648from Lvl. 3.0 Mt.m to 4.50 Mt, 2.26.1 X 2
649Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources), 4.1.8
650Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift., 2.25
651Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.Concrete of M30 grade with minimum cement content of 330 kg /cumAll works upto plinth level, 5.33.1.2
652Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of thespecified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.Concrete of M25 grade with minimum cement content of 330 kg /cumAll works above plinth level, 5.33.2.1
653Add for using extra cement in the items of design mix over and above the specified cement content therein., 5.35
654Centering and shuttering including strutting, propping etc. and removal of form for :, 5.9
655Foundations, footings, bases of columns, etc. for mass concrete, 5.9.1
656Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc., 5.9.2
657Suspended floors, roofs, landings, balconies and access platform, 5.9.3
658Lintels, beams, plinth beams, girders, bressumers and cantilevers, 5.9.5
659Edges of slabs and breaks in floors and wallsUnder 20 cm wide, 5.9.16.1
660Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more., 5.22.6
661Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand), 6.1.1
662Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 ( 1 cement : 6 coarse sand), 6.4.2
663Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 ( 1 cement : 4 coarse sand), 6.4.1
664Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works, 10.25.2
665Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:, 9.21
666Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes, 10.30.1
667Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378)300X16 mm, 9.62.1
668Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378), 9.63
669250x10 mm., 9.63.1
670150x10 mm, 9.63.3
671Providing and fixing Stainless Steel handles, approved quality & make with necessary screws etc all complete. : 125 mm., 9.165.1
67212 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand), 13.7.2
67312 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand), 13.4.2
67415 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement: 6 coarse sand), 13.5.2
675Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs., 22.7.1
676(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
677(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
678Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre, 13.41.1
679Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm), 13.44.1
680Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture, 13.48.2
681Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate, 11.3.1
682Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of :, 22.1.1
683(i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. (iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. Using rough kota stone.
684Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge, 22.2.1
685Using rough kota stone.
686Supplying and fixing C.I. cover without frame for manholes : 560 mm diameter C.I. cover (heavy duty), 19.18.3
687the weight of the cover to be not less than 108 kg
688Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design, 19.15.1
689: With 20x20 mm square bar
690Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required., 1.10
691Group C, 1.10.3
692Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required, 1.14
6932 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire, 1.14.1
6942 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire, 1.14.2
695Supply & fixing of following sizes of medium class PVC conduit along with accessories in surface / recessed including cutting the wall & making good the same in case of recessed conduit as required., 1.21
69625mm, 1.21.2
697Supplying and fixing of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required., 1.24
6985/6 Amps switch, 1.24.1
69915/16 Amp switch, 1.24.3
7003 pin 5/6 Amp socket outlet, 1.24.4
701Supplying & fixing 5 amps to 32 amps rating 240/415 volts, 10 kA, \\"C\\" curve Miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required., 2.1
702Single Pole, 2.10.1
703Supply & fixing of single pole blanking plate in the existing MCB DB complete etc. as required, 2.11
704Supplying & Fixing of following rating double pole (single phase and neutral) 240 volts, Residual Current Circuit Breaker (RCCB), having a sensitivity current upto 30 milli-amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required., 2.14
70540 Amps, 2.14.2
706Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required., 1.31
707Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required., 1.33
708Supplying and fixing brass batten/ angle holder including connection etc. as required., 1.34
709Installation, Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required., 1.35
710Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored), 1.48
711Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required., 1.56
712Earthing with G.I. earth plate 600 mm X 600 mm X 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required., 5.4
713Supply and laying of 25mm x 5mm G.I. strip from earth electrode directly in the ground as required complete in all respect., 5.11
714Supply and laying of 25mm x 5mm copper strip at 0.50 meter below ground as strip earth electrode including connection / terminating with nut ,bolt spring washer etc. jointing shall be done by overlaping and with 2 sets of brass nut bolt&spring washer spaced at 50mm), 5.8
715Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50M., 2.13
716Ordinary rock, 2.13.1
717Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia, 2.13.1.2
718Extra for excavating trenches for pipes, cables, etc. in ordinary/hard rock exceeding 1.5 m in depth but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre), 2.14
719Ordinary rock, 2.14.1
720Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia, 2.14.1.1
721Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
722150 mm dia. R.C.C. pipe, 19.6.2
723250 mm dia. R.C.C. pipe, 19.6.3
724Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design, 19.7
725Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg)., 19.7.1
726With FPS bricks of class designation 75
727(i) For Sewer Line, 19.7.1.1
728Extra for depth of man hole size 90x80 cm, 19.8.1.1
729Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design., 19.16
730Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:, 19.15
731With 20x20mm square bar, 19.15.1
732Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
733M.D. -10- Circular shape 500mm internal diameter, 19.19.2.2
73419.27 Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :, 19.27
735With common burnt clay F.P.S. (non modular) bricks of class designation 7.5, 19.27.1
736Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement: 4 coarse sand) 1) with precast R.C.C. vertical grating complete as per standard design, 19.28
737With common burnt clay F.P.S. (non modular) bricks of class designation 7.5, 19.28.1
738Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work), 18.12
739a) 25mm nominal bore., 18.12.3
740a) 80mm nominal bore., 18.12.8
741Providing & fixing sand of grading zone V or coaser grade alround the G.I. Pipes in external work., 18.41
742a) 25mm nominal bore., 18.41.3
743a) 80mm nominal bore., 18.41.8
744Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :, 18.18
745a) 25mm nominal bore., 18.18.3
746Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 finesand) including testing of joints etc. complete, 19.35
747450 mm dia RCC pipes. (Laying by manual/ machenical means), 19.35.1
748Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m.
749In all kind of soil upto 1.5m depth, 2.6.1
750In all kind of soil upto 1.5m to 3.0m. depth, 2.6.1 + 2.26.1
751In all kind of soil upto 3.0m to 4.5m. depth, 2.6.1 + 2 x 2.26.1
752Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors., 4.1.3
753Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand), 6.1.1
754Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement., 5.1.2
755Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform., 5.9.3
756Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more., 5.22.6
75712mm cement plaster on rough side of single or half brick wall mix
7581:3 (1 cement : 3 Coarse sand), 13.9.1
759Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:, 19.15
760With 20x20mm square bar, 19.15.1
761Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
762M.D. -10- Circular shape 500mm internal diameter, 19.19.2.2
763Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level., 23.2
764Drilling of 300mm dia bore hole manually., 23.2.1.1
765Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge., 23.4
766150 mm nominal size dia, 23.4.2
767Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge., 23.5
768Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge., 23.6
769Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge., 23.7
770Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge., 23.8
771Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
772150 mm nominal size dia, 23.15.2
773Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m.
774In all kind of soil upto 1.5m depth, 2.6.1
775In all kind of soil upto 1.5m to 3.0m. depth, 2.6.1 + 2.26.1
776Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand:4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors., 4.1.3
777Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand), 6.1.1
778Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement., 5.1.2
779Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform., 5.9.3
780Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more., 5.22.6
78112mm cement plaster on rough side of single or half brick wall mix
7821:3 (1 cement : 3 Coarse sand), 13.9.1
783Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:, 19.15
784With 20x20mm square bar, 19.15.1
785Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
786M.D. -10- Circular shape 500mm internal diameter, 19.19.2.2
787Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :, 2.1
788All kinds of soil, 2.10.1
789Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm., 2.10.1.2
790Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered), 2.2
791Depth not exceeding 1.5 meter, 2.20.1
792Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design, 19.3
793150 mm. dia. RCC Pipes, 19.3.2
794250 mm. dia. RCC Pipes, 19.3.4
795300 mm. dia. RCC Pipes, 19.3.5
796Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete., 19.6
797150 mm. dia. RCC Pipes, 19.6.2
798250 mm. dia. RCC Pipes, 19.6.3
799300 mm. dia. RCC Pipes, 19.6.4
800Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design., 19.7
801Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg)., 19.7.1
802With common burnt clay FPS (non modular) bricks of class designation 7.5, 19.7.1.1
803Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design., 19.16
804Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., PWD(20a.2)
805120 sqmm 3 core, 20a.2.3
806Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required, 11.2
807120 sqmm, 11.2.11
808Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required., 11.3
809120 sqmm, 11.3.11
810DISTRIBUTION TRANSFORMERS
811Supply, installation, testing and commissioning offollowing capacity (continuous loading) BEE 3 Starrated (Corresponding Level as per BIS amended uptodate of receipt of tender) , 11/0.433 KV step down, 3Phase, 50 Hz, Dyn 11 vector group, ONAN (OilNatural Air Natural) copper wound transformer(Electrolytic grade 99.9% pure copper, Core made offirst grade Cold Rolled Grain Oriented (CRGO) Coregrade MOH or better, suitable for out door/indoorapplications with Offload Tap Changer/ On Load TapChang (OLTC) ( below 500 KVA offload and above500 KVA On Load Tap Changer) on HV side havingAVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automaticoperation of OLTC and facility for remote and manualoperation of OLTC HV side in range of +5% to -15%in steps of 2.5%, having cable end boxes on HV sidesuitable for 3x300 sq.mm XLPE cable of 11 KV grade, 24.7
812including bus trunking arrangement on LV side
813including supplying and laying of copper conductor
814multicore control cable from transformer to HT
815breaker/panel for safety tripping, complete with all
816accessories and safety provisions as per relevant IS
817Code including first filling of filtered dehydrated oil, i/c
818supplying and grouting of suitable M.S. Channel withall accessories and transformer shall be confirming toIS : 2026 (Part 1 to Part 5), IS : 1180 and as perCPWD specifications complete in all respects etc asrequired at site. The maximum flux density in any partof the core and yoke at rated voltage and frequencyshall be such that the flux density with + 12.5 percentcombined voltage and frequency variation from ratedvoltage and frequency does not exceed 1.9 Tesla. Thepermissible temperature-rise shall not exceed 35 0Cfor oil and 40 0C up to 200 KVA and 40 0C for oil and45 0C for above 200 KVA for winding. Inside of tankshall be painted with varnish or liquid resistant paint.For external surfaces one coat of thermo settingpowder paint or one coat of epoxy primer followed bytwo coats of polyurethane base paint shall be used.IS: 1180 (Part 3) shall be referred to for paintthickness fornormal to medium corrosive atmosphere.For highly polluted atmosphere and special applicationexternal paint work shall be as per direction ofEngineer-in-Charge. Design ambient condition : a) airtemperature 50 0C, b) Relative Humidity 90 % Max,c) Seismic Zone as per location of site, d) Altitude as
819per location/site. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard. Thetransformer should have QR code which shouldcontain drawing, test report OEM manual, Geo- Tag ofmanufacturing location etc. Marking Each transformershall be provided with rating plate made of anodizedaluminium/ stainless steel material securely fixed onthe outer body, easily accessible, as per IS: 1180Part-3. The entries on the rating plate shall beindelibly marked.
820Fitting and Accessories : The following fittings shallbe provided:- a) Two earthing terminals with theearthing symbol b) Oil level gauge indicating oil levelat minimum, 30°C and maximum operatingtemperature; c) Air release device (for non-sealedtype transformers) d) Rating and terminal markingplates; e) Silica gel breather f) Drain-cum-samplingvalve (¾″ nominal size thread, IS 554) preferably steelwith plug for three phase transformers; g)Thermometer pocket with cap; h) Oil filling holeshaving (1¼″ nominal size thread) with cover (forsealed type transformers without conservator); i)Lifting lugs for the complete transformer as well as forcore and winding assembly; j) Pressure relief device
821or explosion vent above 200 kVA; k) One filter valveon the upper side of the tank (for transformers above200 kVA); l) Unidirectional flat rollers (for transformersabove 200 kVA); m) Inspection hole (for transformersabove 200 kVA); n) HV side neutral grounding strip(where one of the HV bushing terminal is connected toearth); o) Buchholz relay for transformers above 800kVA. p) Arcing horns or suitable rating lightningarrestors for HT side – 3 Nos. q) Bird guard; r) Oiltemperature indicator and winding temperatureindicators for transformers above 200 kVA withsuitable tripping mechanism above permissible limit s)Jacking pads (for transformer above 1 600 kVA); tAdditional Neutral separately brought out on bushingfor earthing. u) Magnetic oil level gauge (fortransformer above 1600 kVA) with low oil level alarmcontact; v) Non return valve (for conducting pressuretest); w) Pressure relief device or explosion vent x).Monogram Plate y) Inspection cover z). Detachabletype radiators with top and bottom shutoff valve. aa)Oil Conservator with Oil level indicator, minimum levelmarking and drain plug for all transformers of capacity50 KVA and above. bb) Necessary hardware, clamps,lugs etc. for termination on HV/MV etc. for alltransformers.
822Transformer described as above.
823400KVA = 1 Nos., 24.7.4
824DG SET-
825Supplying, Installation, Testing & Commissioning of‘Silent Type Diesel Generating set as per CPCB IV +or better norms along with having Prime Power Ratingof KVA as below, 415 volts at 1500 RPM, 0.8 laggingpower factor at 415 V suitable for 50 Hz, 3 phasesystem & for 0.85 Load Factor, including testing atfactory and site with fuel, load for test and othernecessary arrangements Complete as per CPWDspecifications, should have QR code which shouldcontain drawing, test report OEM manual,Geo- Tag ofmanufacturing location, rating plate as per relevant ISCode etc. and consisting of the followings:(A) Diesel Engine:Tourbocharged Diesel engine 4 stroke water cooled,multi cylinder, dynamically balanced fly wheel, electricstart of suitable BHP at 1500 RPM suitable for aboveoutput of alternator at 40 0C, 50% RH & at 1000 MeterMSL , capable of taking 10% over loading for one hourafter 12 hours of continuous operation. The engine willbe with Electronic governor, Dry type Air filter withservice indicator, first filling of engine fuel (aftercommissioning) lubricating Oil, Coolant and otherconsumables complete with all the requiredaccessories, the Electronic governor shall be as perISO 8528.The engine shall comply to the latest CPCBnorms (CPCB IV + or better) and Conforming to BS5514, BS 649, IS 10000, IS 10002, IS 130and asper CPWD specifications.(B) Engine mounted Instrument Panel fitted with andhaving digital dis Plate for following:, 29.1
826(i) Start-stop switch with key(ii) Water temperature indication(iii) Lubrication oil pressure indication(iv) Lubrication oil temperature indication(v) Battery charging indication and Voltage indication(vi) RPM indication(vii) Over speed indication(viii) Low lubricantion Oil trip indication(ix) Engine Running Hours indication(x) Fuel Level
827(C) Alternator:Synchronous alternator rated of appropriate KVA, 415volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8lagging power factor at 40 0C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balancerotor, capable of taking 10% over loading for one hourafter 12 hours of continuous operation, selfcooled, self-excited and self-regulated through AVRconforming to IS13364(Part 2)/IS: 4722/BS 2613suitable for tropical conditions and with class- Hinsulation.
828(D) Base Frame & Foundation
829Both the engine and alternator shall be mounted onsuitable base frame made of MS channel with necessary reinforcement which shall be installed onsuitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.
830(E) FUEL TANK:
831Daily service fuel tank of suitable liters capacity as perCPWD Specifications, fabricated out of 3 mm thickM.S. sheet complete with all standard accessories andfuel piping between fuel tank and diesel engine withMS class ‘C’ pipes of suitable dia. Complete withvalves, level indications & accessories as required asper specifications.
832(F) Exhaust System:
833Dry exhaust manifold with hospital type exhaustsilencer and catalytic convertor.
834(G) Starting System:
83512V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set.
836(H) 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set.
837(I) AMF Panel:
838Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following:
8391. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip.
8402. Auto/Manual/Test/Off selector switch
8413. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay).
8424. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering
8435. Energy analyser unit to indicate current, Voltage( LN & L_L), kW, kVA (Phase & Total), Frequency, KWH, PF.
8446. LED Indicating lamps for load on mains and load on set
8457. Fuse/ MCB for instruments
8468. Battery charger, complete with transformer/ rectifier,
847D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.
8489. Main supply failure monitor
84910. Supply failure timer
85011. Restoration timer
85112. Control unit with three impulse automatic engine
852start/stop and failure to start lockout.
85313. Impulse counter with locking and reset facility.
85414. ON/OFF/Control circuit switch with indicator
85515. Audio/Video annunciation for
856(i) High water temperature
857(ii) Low lubricating oil pressure
858(iii) Engine over speed
859(iv) Engine fails to start
860(v) Full load/maximum load warning
86116. Protection for over/under Frequency, Loss of AC
862sensing, Over Current, Unbalancing load with suitable
863number of relays and accessories
86417. Maintenance notification based on Engine Run Hour & due date.
86518. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring.
866250 KVA 1 NOS., 29.1.11
867LT Cable
868Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc., PWD(20a.1)
8696 sq. mm 2 core, 20a.1.1
87010 sq. mm 2 core, 20a.1.2
87110 sq. mm 4 core, 20a.1.8
87225 sq. mm 3-1/2 core, 20a.1.10
87350sq. mm 3-1/2 core, 20a.1.12
874185 sq. mm 3-1/2 core, 20a.1.17
875400 sq. mm 3-1/2 core, 20a.1.20
876Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required, 11.1
8776 sq. mm 2 core, 11.1.1
87810 sq. mm 2 core, 11.1.2
87910 sq. mm 4 core, 11.1.32
88025 sq. mm 3-1/2 core, 11.1.21
88150sq. mm 3-1/2 core, 11.1.22
882185 sq. mm 3-1/2 core, 11.1.27
883400 sq. mm 3-1/2 core, 11.1.31
884LED Smart Street light fixture, powder coated pressure die cast aluminium (System. System lumen efficacy >135 lm/Watt)., 8.19
885Supplying, installation, Testing & Commissioning of Smart Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement ( < 700ma), Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P.F.≥0.95, IP-66,IK- 08, CRI >70, under voltage and over voltage protection, EMI- EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVCinsulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall besubmitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 900C)
886Smart inbuilt controller shall have following features.
8871. Control and monitor LED luminaries with bi directional control( Status, Fault, Alarm, dimming level, wattage, energy)2.to measure voltage, current, power, power factor,apparent energy, active energy, operating hours3.Inbuilt ambient light sensor, motion sensor basedon Passive Infra Red (PIR).4. Wi-Fi LoRA/Zigbee/Powerline with ethernetnetwork based IOT feature as per site requirementor engineer in charge.5.should be controlled through auto/ manual6. Programmable level of not less than 48 differentlight intensity settings,7. inbuilt repeater & relay signals function to othercontrollers
88850 watt, 8.20.2
889Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift., 2.25A
890Earth work in excavation, DSR-2.8.1
891P.C.C. 1:4:8, DSR-4.1.8
892Brick work in 1:4 in foundation., DSR-6.1.1
89315 MM thick plaster (1:4), DSR (13.5.1)
894cement : Coarse sand, DSR (13.5.1)
89525 MM thick flooring, DSR-11.3.1
896Earth work in excavation, DSR-2.8.1
897P.C.C. 1:4:8, DSR-4.1.8
898Brick work in 1:4 in foundation., DSR-6.1.1
89915 MM thick plaster (1:4), DSR (13.5.1)
900cement : Coarse sand, DSR (13.5.1)
90125 MM thick flooring, DSR-11.3.1
902(A) Boring 150 dia bore hole including labour, T & P etc. required for proper complete of the work, AS PER MAINPURI UPPWD SOR
903(B) Lowering 110 dia mm PVC pipe in bore hole including labour, T & P etc. required for proper compelete of the work., AS PER MAINPURI UPPWD SOR
904(C) Providing and fixing 110 mm dia PVC pipe 6KG/cm², AS PER MAINPURI UPPWD SOR
905(D) Surrounding and packing graded coarse sand between bore wall & strainer including supply of coarse sand, labour, T&P etc requried for proper compeletion of work., DSR-23.7*0.757*1
906(E) Providing and fixing G.I. pipe 32mm dia complete with G.I. fitting, DSR-18.23.3*0.757*1
907Supplying, Installation, Testing and Commissioning ofthree phase openwell ISI Marked submersible pumpset of 7.5 H.P. capacity suitable for operation on415V(+-10%), 3- phase AC supply compatible foroperations on dynamic variable frequency / speedhaving IP 68 Protection including providing requiredno's of heavy duty M.S clamps made of flat iron andsuitable size top cover made of suitable thick MSsheet as required. and making of flexible IP68 cableconnections etc. complete as required., DSR_EM-2025 20.19*0.789*107/110
908(J) 2.5 mm sq cable for submersible motor pump, AS PER MAINPURI UPPWD SOR
909(K) Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.100 mm clamp, DSR-23.14.1*0.757*1
910(L) 100 mm dia PVC end cap, AS PER MAINPURI UPPWD SOR
911(M) Solution for jointing PVC pipe (250 gram), AS PER MAINPURI UPPWD SOR
912(N) 32 mm CPVC pipe, DSR-18.9.4
913(O)Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of useable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approvedmethod, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, including disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge., DSR-23.12*0.757
914(P) Nylon cloth for strainer including plastic rope, cutting holes in PVC pipe etc complete., AS PER MAINPURI UPPWD SOR Please Enable Macros to View BoQ information

Other Detail

Information Source https://etender.up.nic.in
Download FileName File Description File Size
Download 06715300-ec36-4538-951a-a162f0690e04.html Tender Documents 0 KB
Download Ayodhya_SBD.pdf Tender Documents 0 KB
Download BOQ_2140758.xls Tender Documents 0 KB
Download Tendernotice_1 (15).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.