| 1 | Construction of U.P. Sanskrit Shiksha Parishad New Building and U.P. Sanskrit Shiksha Nidesahalya New Building behind Campus Rajkiya Inter College, Nisatganj Lucknow Campus District-Lucknow (U.P.) |
| 2 | Council Building(Part A) |
| 3 | EARTHWORK |
| 4 | Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. |
| 5 | FILLING |
| 6 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 7 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. |
| 8 | PCC WORK |
| 9 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 10 | ANTI- TERMIDE |
| 11 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground. floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment of soil along external perimeter of building 7.5 liters/sqm. (5) Treatment of soil under apron along external perimter 5 liters/sqm. |
| 12 | DAMP PROOF COURSE |
| 13 | Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 14 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 15 | RCC WORK |
| 16 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 17 | RCC work in foundation |
| 18 | RCC work in column below the PL |
| 19 | All works above plinth level upto floor V level |
| 20 | RCC work in column |
| 21 | RCC work in beam |
| 22 | RCC work in slabe |
| 23 | BRICK WORK |
| 24 | M-150 brick work in one cement & six coarse sand 2.25 F.M. mortar in foundation and plinth including supply of all materials labour, tools and plants etc. required for proper completion of the work. |
| 25 | M-150 Brick work in super-structure above plinth level up to floor two level (up to two storeys) including necessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:4 cement & coarse sand) |
| 26 | Same as in item no. 10 but in 1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. |
| 27 | WATERPROOFING TREATMENT |
| 28 | Providing & laying \\"brick Coba\\" 120mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrylic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono lythic plaster wall upto 30cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour T & P etc complete for proper completion of work. |
| 29 | DOOR/WINDOW /VENTILATOR |
| 30 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 31 | (a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 32 | (b) Add extra for Double leaf shutter |
| 33 | Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) |
| 34 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. |
| 35 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 36 | Door / windows & Staircase grill. |
| 37 | Sypply & fixing of Z-section steel windows |
| 38 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 39 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R3 series with frame (98 mm & above) x (40 mm & above) & both glazed and fly screen sash (30 mm & above) x (55 mm & above) with zinc alloy (Zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m). |
| 40 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 41 | Providing and Fixing factory made uPVC door frame, made of uPVC exturded sections, of size 65 mm x 55 mm with wall thickness 2.0 mm (+ 0.2 mm), corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mm x 30 mm having wall thickness 2 mm (+0.2 mm), including providing & fixing 3 nos of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number & size of anchor dash fastners, all complete as per manufacturer’s specification and direction of Engineer-in-charge. |
| 42 | Providing and fixing 37 mm thick factory made PVC door shutter, styles and rails made of PVC hollow section of size 100 mm x 37 mm with wall thickness 2 mm (+ 0.2 mm), with inbuilt bead on one side, styles and rails mitered cut and joint at the corners by means of 2 nos of plastic brackets of size 75 mm x 220 mm at each corner and stainless steel screws, reinforcing the hinge side of style by inserting PVC profile of size 28 mm x 30 mm, with wall thickness 2 mm (+ 0.2 mm). Lockrail of size 100 mm x 37 mm, wall thickness 2 mm (+ 0.2 mm) will be fixed to the vertical styles. Providing with PVC snapfit beads and panel of size 100 mm x 20 mm, and inserting 2 nos tie bar of 6 mm dia and fastening with nuts and washers complete, all as per manufacturer’s specification and direction of Engineer-in-charge. |
| 43 | TMT FE-500 or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. |
| 44 | Fixing of Door, windows/ventilators chaukhats in position. |
| 45 | (a) Door |
| 46 | (b) Windows |
| 47 | (c) Ventilator chaukhats |
| 48 | 15 mm plinth plaster (1 cement :4 coarse sand) |
| 49 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1) 1 cement : 6 coarse sand. |
| 50 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand |
| 51 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 52 | 40 mm thick 1:2:4 plain cement concrete floor (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement. |
| 53 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Light shade pigment using white cement |
| 54 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the approved make & colours) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 55 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm |
| 56 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick. |
| 57 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 58 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. (Area of slab upto 0.50 sqm) |
| 59 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 60 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 61 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 62 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 63 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 64 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 65 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (Ceiling) |
| 66 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand & anufacturer, over the plastered wall surface to prepare the surface even & smooth complete. |
| 67 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 68 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : (a) 250mm x 16mm . |
| 69 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete: |
| 70 | (a) 250 mm x 10mm |
| 71 | (a) 200 mm x 10mm |
| 72 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : (a) 125 mm |
| 73 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 74 | Making of drain along with apron (Size 150*150mm) |
| 75 | Supply & filling of cinder in sunken portion of building including braking in to required sizes including supply of all material, T&P required size including of supply of all material , labour, T&P required for proper completion of work. |
| 76 | Providing and laying water proofing treatment in sunken portion of W.C., bathroom etc, by applying cement slurry mixed with water proofing cement compound consisting of applying :- (a) First layer of slurry of cement @ 0.488 Kg/Sqm mixed with water proofing cement compound @ 0.253 kg/Sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 Kg/Sqm mixed with water proofing cement compound @ 0.126 kg/Sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 77 | Expension joint teatment with 2 mm thick aluminium sheet and 4 cm thick bitumastic sheet with hot bitumen of approved aulity. (As per Rate analysis & specification attached) HORIZONTAL EXPANSION JOINT |
| 78 | Providing & fixing aluminium sheet 2 mm thick for Vertical expansion joint work including labour and all materials etc . Powder coated aluminium (minimum thickness of powder coating 50 micron) VERTICAL EXPANSION JOINT |
| 79 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 80 | (a) Foundations, footings, bases of columns, etc. for mass concrete |
| 81 | (b) Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
| 82 | (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 83 | (d) Columns, Pillars, Piers, Abutments, Posts and Struts |
| 84 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on inter-locking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6 mm reveal profile (white/ black),comprising of main-T runners of size 15x42 mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary ntermediate cross-T of size 15x42 mm of length 600 mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge |
| 85 | Providing and fixing glass reinforced cement panels |
| 86 | Providing and fixing glass reinforced cement shikhar small size |
| 87 | Finishing wall with rustic, stone, and smooth finishes on the surface such as a wall, involves a process of surface preparation, material application, and achieving the desired texture. This process typically includes cleaning the surface, applying a primer, mixing the texture coating, applying the coating, and allowing it to dry. Specific techniques and tools, like trowels, rollers, or sprayers, are used to create the desired texture.specification are primer sealed (MS sealed) should be 25 to 50 micron, texture paint(megatext) should be 1 mm min & top coat (dulux inspire exterior) should be 25 to 50 micron |
| 88 | Providing and fixing of façade at all heights with extruded hollow Clay / Terracotta ventilated rainscreen tiles of height 259/ 309/ 409 mm and lengthof 1190 mm of approved texture,design and pattern having Flexural Strength/ Modulus of Rupture of ≥ 14 N/m² and maximum water absorption of 10% tested as per ISO 10545-4:2004(E) and ISO 10545-3:1995 respectively in true level fixed to a supporting aluminium framework (Alloy 6063 T5/T6) consisting of vertical ‘T’ (for intermediates)/ ‘L’ (for ends/ termination)/ Tubular sections (at corners)of size 80x60x2 mm/ 40x60x2 mm/ 40x40x2 mm respectively, spaced at maximum spacing of 1200 mm c/c matching to the tile vertical grid, and horizontal aluminium ‘C’-clamps of size 56x34x2 mm thickness of length 150 mm at junction of tiles and of length 75 mm at wall ends/ corners fixed on top of the vertical sections at spacing of 250/ 300/ 400 mm c/c matching to the tile horizontal grid with two numbers of self-drilling / self-tapping SS screws of size 5.5x25 mm with EPDM washers. The vertical ‘T’/’L/ Tubular’ sections shall be fixed to the wall using HDG (hot-dip-galvanized) steel L-brackets (galvanizing thickness of minimum 80 microns) of size 110x80x6 mm at intermediate vertical aluminium profiles and of size 220x110x12 mm at outer corners and stainless steel grade 304,M10 full threaded anchor fasteners with nylon sleeve 100 mm long (for brick work) and M8 expansion anchor fasteners 75 mm long for concrete surface, spacing of brackets to be based on a structural/ static calculation. The brackets shall be of length 175 mm at junction of two vertical aluminium profiles and of length 100 mm at intermediate points of vertical profiles and shall be fixed to the vertical aluminium T / L / Tubular profiles using two numbers self-drilling/ self-tapping SS screws of size 5.5x25 mm with EPDM washers. EPDM gaskets to be fixed in between brackets and vertical profiles. The tiles shall be mounted on the ‘C’ clamps such that the tiles are supported at top and bottom at both ends. The tiles shall be mounted on the C-clamps with EPDM profiles in between such that the tiles are supported at top and bottom at both ends |
| 89 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. The vertical joint open groove between two adjacent tiles shall be 10 mm. The tiles and system shall be designed to resist wind load as per IS 875 (Part 3) according to different zones. The tiles shall be installed using the ventilated rain screen principle with provision for natural ventilation of the space between the façade tiles and the structural wall. The work shall be carried out as per specification, drawing and as per direction of the Engineer-in-Charge. With 24 mm thickness (+/- 10%) terracotta tiles of other than grey colors |
| 90 | BILL OF QUANTITY |
| 91 | EXTERNAL FIRE FIGHTING SYSTEM |
| 92 | Fire Pump Set : |
| 93 | Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads. |
| 94 | 2280 lpm at 88 m Head |
| 95 | (Note : The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point.) |
| 96 | Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : Diesel Driven Pump Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. |
| 97 | Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. |
| 98 | M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. |
| 99 | 2280 lpm at 88 m Head |
| 100 | (Note : The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point.) |
| 101 | Incoming : |
| 102 | 400A, 50kA 4 Pole MCCB, Ics=100% Icu Rating Digital Voltmeter 0-500V with selector switch, Ammeter (0-400 A) with selector swtich & CTs etc. |
| 103 | LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps. |
| 104 | Set of Copper Bus Bar 500A |
| 105 | Outgoings : |
| 106 | (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps). |
| 107 | Main Fire Pump : |
| 108 | 200 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 Set |
| 109 | Jockey Pump : |
| 110 | 100 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 Set |
| 111 | Diesel Engine Control : |
| 112 | Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons,start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication |
| 113 | Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine |
| 114 | System Controller : |
| 115 | Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification |
| 116 | Pipes & Accessories : |
| 117 | Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (Uderground) |
| 118 | 150 mm. Dia |
| 119 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 120 | 80 mm dia |
| 121 | 100 mm dia |
| 122 | 150 mm dia |
| 123 | 200 mm dia |
| 124 | Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : |
| 125 | 80 mm dia |
| 126 | 100 mm dia |
| 127 | 150 mm dia |
| 128 | 200 mm dia |
| 129 | Supplying, fixing, testing & commissioning of double flanged Sluice Valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : |
| 130 | 80 mm dia |
| 131 | 150 mm dia |
| 132 | 200 mm dia |
| 133 | Supplying and fixing Orifice Plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 134 | Providing, installation, testing and commissioning of Non-Return Valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : |
| 135 | 80 mm dia |
| 136 | 100 mm dia |
| 137 | Providing, installation, testing and commissioning of stainless steel Y-Strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. |
| 138 | 150 mm dia |
| 139 | Providing & fixing of Pressure Switch in M.S. pipe line including connection etc. as required. |
| 140 | Providing & fixing Flow Switch in following sizes M.S. pipe including connection etc as required. |
| 141 | 150mm dia |
| 142 | Providing, fixing, testing & commissioning of installation Control Valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : |
| 143 | 150 mm dia |
| 144 | Fire Extinguishers : |
| 145 | Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 146 | Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 147 | Fire Sand Bucket : |
| 148 | Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge. |
| 149 | Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules |
| 150 | Providing, fixing, testing & commissioning of resilient rubber lined single Arch Vibration Eliminators suitable for raw water up to 45oC temperature, working pressure 8.8 Kg/cm2 and test pressure 20 Kg/cm2 for :- |
| 151 | 150 mm dia |
| 152 | ADDRESSABLE FIRE DETECTION & ALARM SYSTEM |
| 153 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessedconduit as required.(rate taken from internal electrical DSR) |
| 154 | 25 mm dia. |
| 155 | Supplying, installation, testing & commissioning of heat detector operating at 54°C/57°C with rate of rise cum fixed tempreature (dual thermistor) type with mounting base complete with all connection etc. as required. |
| 156 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 157 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 158 | Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. |
| 159 | Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required.6 zone panel for fire alarm system100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required- 2 Nos. (one to act as standby)Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set.Announcement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set.Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFFswitch, fuse visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch -1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt, 30 AH each sealed maintenance free batteries -1 set. |
| 160 | Supplying instalation testing & comisioning of exit point directional sound speaker with voice and integral audio amplifier with selectable sound pulse patterns complete as required |
| 161 | supplying and laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000v rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 162 | Controle panel |
| 163 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: |
| 164 | 80 mm dia |
| 165 | 100 mm dia |
| 166 | 150 mm dia |
| 167 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required |
| 168 | 100 mm dia |
| 169 | 150 mm dia |
| 170 | Providing, installation, testing and commissioning of non-returnvalve of following sizes confirming to IS: 5312 complete with rubber gasket, Gl bolts, nuts, washers etc.as required : |
| 171 | 100 mm dia |
| 172 | 150 mm dia |
| 173 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. |
| 174 | 100 mm dia |
| 175 | 150 mm dia |
| 176 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63mm dia male and female couplings duly bound with GI wire, rivetsete. conforming to IS 636 (type-A) as required |
| 177 | Stainless Steel (Grade 304) |
| 178 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic. (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket |
| 179 | CO2 type fire existinguisher capacity : 4.5 k.g. |
| 180 | Water type fire extinguisher capacity 9 ltr. |
| 181 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. |
| 182 | Two Loop Panel. |
| 183 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 184 | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. |
| 185 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 186 | Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. |
| 187 | Supplying, installation, testing & commissioning of fault isolator complete with base as required. |
| 188 | Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. |
| 189 | Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. |
| 190 | Supplying, installation, testing & commissioning of addressable fire control module complete as required. |
| 191 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. |
| 192 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheathcomplete as required. |
| 193 | Supplying, installation, testing & commissioning of 6 zone,voice alarm controller with USB, MP3 player (including 6 zonebutton paging station) with seamless integration facility withmain fire alarm panel for voice evacuation complete asrequired. |
| 194 | Supplying, installation, testing & commissioning of 1.5/3/6Wmetal box ceiling/wall speakers complete as required |
| 195 | Supplying, installation, testing & commissioning of digitalaudio amplifier 75 Watt, 25V rms operating at 240 Volt ACSupply complete as required. |
| 196 | Supplying, installation, testing & commissioning of exit pointdirectional sound speaker with voice and integral audioamplifier with selectable sound pulse patterns complete asrequired. |
| 197 | Supplying, installation, testing & commissioning of voice command keypad 6 zone with microphone assembly complete as required |
| 198 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed Pvc conduit of following pairs, cores and size including connections and interconnections etc. as required. |
| 199 | speaker cable Three pair, 2-core, 1.5 sqmm |
| 200 | speaker cable Four pair, 2-core, 1.5 sqmm |
| 201 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 202 | 20mm dia PVC conduit |
| 203 | 25mm dia PVC conduit |
| 204 | 32mm dia PVC conduit |
| 205 | (COST OF EXTERNAL RAIN WATER HARVESTING WORKS) |
| 206 | RAIN WATER HARVESTING |
| 207 | In all kind of soil upto 1.5m to 3.0m. depth |
| 208 | In all kind of soil upto 3.0m to 4.5m. depth |
| 209 | In all kind of soil upto 4.5 m to 6.0m. depth |
| 210 | Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. |
| 211 | Class M-150 brick work in 1:4 cement coarse sand mortar in foundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. |
| 212 | Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. |
| 213 | Suspended floors, roofs, landings, balconies and access platform. |
| 214 | Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 215 | 12mm cement plaster on rough side of single or half brick wall mix |
| 216 | 1:3 (1 cement : 3 Coarse sand) |
| 217 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: |
| 218 | With 20x20mm square bar |
| 219 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 220 | M.D. -10- Circular shape 500mm internal diameter |
| 221 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. |
| 222 | Drilling of 300mm dia bore hole manually. |
| 223 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
| 224 | 150 mm nominal size dia |
| 225 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 226 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 227 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge. |
| 228 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 229 | DESILTING CHAMBER |
| 230 | In all kind of soil upto 1.5m to 3.0m. depth |
| 231 | Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. |
| 232 | Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. |
| 233 | Suspended floors, roofs, landings, balconies and access platform. |
| 234 | Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 235 | 12mm cement plaster on rough side of single or half brick wall mix |
| 236 | 1:3 (1 cement : 3 Coarse sand) |
| 237 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: |
| 238 | With 20x20mm square bar |
| 239 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 240 | M.D. -10- Circular shape 500mm internal diameter |
| 241 | DRAINAGE NETWORK |
| 242 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. |
| 243 | up to 1.50 m depth |
| 244 | Pipes 80 mm to 300 mm diameter |
| 245 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. |
| 246 | 150 mm. dia. RCC Pipes |
| 247 | 250 mm. dia. RCC Pipes |
| 248 | 600 mm. dia. RCC Pipes |
| 249 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design |
| 250 | 150 mm. dia. |
| 251 | 250 mm. dia. |
| 252 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. |
| 253 | Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). |
| 254 | With common burnt clay FPS (non modular) bricks of class designation 75 |
| 255 | (i) For Sewer Line |
| 256 | Extra for depth for manholes: |
| 257 | Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 |
| 258 | EXTERNAL PLUMBING WORKS |
| 259 | SUB HEAD - I - (SEWERAGE AND DRAINAGE) |
| 260 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : |
| 261 | All kinds of soil |
| 262 | Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm. |
| 263 | Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) |
| 264 | Depth not exceeding 1.5 meter |
| 265 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design |
| 266 | 150 mm. dia. RCC Pipes |
| 267 | 250 mm. dia. RCC Pipes |
| 268 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. |
| 269 | 150 mm. dia. RCC Pipes |
| 270 | 250 mm. dia. RCC Pipes |
| 271 | Providing and fixing square-mouth S.W. gully trap SP-1 complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design |
| 272 | 150 x 100 mm size P type |
| 273 | With common burnt clay FPS (non modular) bricks of class designation 75 |
| 274 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: |
| 275 | 100 mm diameter |
| 276 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. |
| 277 | Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). |
| 278 | With common burnt clay FPS (non modular) bricks of class designation 7.5 |
| 279 | Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :- |
| 280 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 281 | Extra for depth for manholes: |
| 282 | Size 90x80cm |
| 283 | With common burnt clay FPS (non modular) bricks of class designation 7.5 |
| 284 | Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 285 | SUB HEAD - II - EXTERNAL WATER SUPPLY |
| 286 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :- |
| 287 | All kinds of soil |
| 288 | Pipes, cables etc, not exceeding 80 mm dia. |
| 289 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. |
| 290 | 25 mm dia nominal bore |
| 291 | 32 mm dia nominal bore |
| 292 | 40 mm dia nominal bore |
| 293 | 50 mm dia nominal bore |
| 294 | 80 mm dia nominal bore |
| 295 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :- |
| 296 | 25 mm dia nominal bore |
| 297 | 32 mm dia nominal bore |
| 298 | 40 mm dia nominal bore |
| 299 | 50 mm dia nominal bore |
| 300 | 80 mm dia nominal bore |
| 301 | Providing and filling sand of grading zone V or coarser grade alround the G.I. pipes in external work. |
| 302 | 25 mm dia nominal bore |
| 303 | 32 mm dia nominal bore |
| 304 | 40 mm dia nominal bore |
| 305 | 50 mm dia nominal bore |
| 306 | 80 mm dia nominal bore |
| 307 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. |
| 308 | 25 mm dia nominal bore |
| 309 | 32 mm dia nominal bore |
| 310 | 40 mm dia nominal bore |
| 311 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required:- |
| 312 | 50 mm dia |
| 313 | 80 mm dia |
| 314 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 315 | 25 to 40 mm nominal bore |
| 316 | 50 to 80 mm nominal bore |
| 317 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design:- |
| 318 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 319 | Constructing masonry Chamber 60 x 60 x 75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 fine sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and180 mm deep (inside) with chain lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. |
| 320 | With F.P.S. bricks |
| 321 | (COST OF EXTERNAL SEWERAGE (SEPTIC TANK) WORKS) |
| 322 | SEPTIC TANK & SOAK PIT |
| 323 | Size :- Length = 7.50 M. Width = 2.65M Total Depth =3.00M |
| 324 | In all kind of soil upto 1.5m to 3.0m. depth |
| 325 | In all kind of soil upto 3.0m to 4.5m. depth |
| 326 | Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size) |
| 327 | Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. |
| 328 | Suspended floors, roofs, landings, balconies and access platform. |
| 329 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 330 | 12mm cement plaster on rough side of mix 1:3 (1 cement : 3 coarse sand) |
| 331 | Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. |
| 332 | Providing and fixing C.I. tee at the inlet and outlet of septic tank. |
| 333 | Providing & fixing 75mm dia vent pipes. |
| 334 | Providing & fixing of 75mm dia cast iron terminal guard. |
| 335 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 336 | M.D. -10- Circular shape 500mm internal diameter |
| 337 | M.D. -2.5- Circular shape 450mm internal diameter |
| 338 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. |
| 339 | With F.P.S. bricks |
| 340 | BILL OF QUANTITY OF PROPOSED UNDER GROUND WATER STORAGE TANK |
| 341 | Add to item no. 1 for every additional lead of 30 mt. or part of 30mt and for every additional lift of 1.50mt. or part of 1.50 mt. |
| 342 | 3.00 to 4.50 mtr. |
| 343 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 344 | Providing and laying water proofing treatment in underground structure by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry |
| 345 | Mechanical Motor System For Water Sump |
| 346 | HORIZONTAL EXPANSION JOINT |
| 347 | M-150 Brick work in super-structure above plinth level up to floor two level (up to two storeys) including necessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:6 cement & coarse sand). |
| 348 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1) 1 cement : 6 coarse sand. |
| 349 | Providing & fixing aluminium sheet 2 mm thick for Vertical expansion joint work including labour and all materials etc |
| 350 | For fixed portion |
| 351 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 352 | 4 cm thick bitumastic sheet with hot bitumen of approved quality, using stone chippings (60% with 12.5 mm nominal size and 40% with 10 mm nominal size) @ 2.60 cum per 100 sqm and coarse sand @ 2.60 cum per 100 sqm of road surface and with bitumen @ 56 kg/cum of stone chippings and @ 128 kg/cum of sand over a tack coat with hot straight run bitumen, including consolidation with road roller of 8 to 10 tonne etc. complete. (tack coat to be paid separately) : |
| 353 | With paving Asphalt grade VG - 10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt |
| 354 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than (M-20)(1 cement : 1.5 coarse sand : 3 stone aggregates) |
| 355 | Providing & laying Asphalt mix coarse sand with bitumen of grade 85/25 |
| 356 | FACADE WORKS |
| 357 | FAÇADE WORK |
| 358 | Ac Work |
| 359 | Part A |
| 360 | Supply of DAIKIN make 16.5 TR Ductable AC R-410 Gas |
| 361 | Supply of DAIKIN make 11.0 TR Ductable AC R-410 Gas |
| 362 | PART-B- INSTALLATION WORK |
| 363 | Installation Testing And Commissioning |
| 364 | Ductable AC installation 16.5 TR |
| 365 | Ductable AC installation 11.0 TR |
| 366 | Refrigrant Piping |
| 367 | Installation of Copper Piping with insulation 11 TR Ductable AC |
| 368 | Frame Work |
| 369 | MS base fabricated Frame And installation For odu |
| 370 | Drain Pipe |
| 371 | PVC Drain Pipe with insulation and installation |
| 372 | Communication Cable |
| 373 | Ductable ac 8x2.5 sq mm Copper PolyCab |
| 374 | Fabrication of GI Sheet Metal Rectungular Duct with Supports Vanes nuts bolts gasket Etc. |
| 375 | Fabrication of 22 Gauge Ducting |
| 376 | Fabrication of 24 Gauge Ducting |
| 377 | Canvas Connection of Ducted Units |
| 378 | Duct insulation |
| 379 | Duct insulation With 9 mm Nytril Rubber in Ducting |
| 380 | Acosting insulation With 9 mm Nytril Rubber in Ducting |
| 381 | Grill and Diffusers |
| 382 | AL. Powder Coated S/R Air Diffuser |
| 383 | MS Volume Control coller Dampers |
| 384 | Miscellanious work |
| 385 | Lifting Shifting & Placing of indoor & Outdoor Units |
| 386 | HIGH BACK CHAIR:Supplying and Placing in Position of rich/37819/hb : high back leatherette chair in black colour with matte finish specification : Durian - office seating - president chair , Type : High back 360° degre revolving chair sku : rich/37819/hb/xx, All over size is : 665mm(l)x 550mm(d)x 1200mm(h) , The chair made of full leatherette in black colour . It will comes in matte finsih in contemporary style . Details : Arms : pp arms with pu padding . Use of ply: 12 mm thick hot pressed bwr plywood (is grade - 303 for seat and back) . Seat: 40 ± 2 mm thick polyurethane foam with density 32 (±3) kg per cu meter for best quality cushioning in seat , Back : 40 ± 2 mm thick polyurethane foam with density 32 (±3) kg per cu meter for best quality cushioning in back . backrest support foam design based on symmetrical lumbar support mechanism : knee tilting mechanism . Only seat size is 665mm(l)x 500mm(d) & the back size is 665mm(l)x 580mm(h) |
| 387 | VISITOR'S CHAIR:Supplying and Placing in Position of rich/37819/lb/xx : low back leatherette chair in black colour with matte finish specification : Durian - office seating - president chair , Type : Low back 360° degre revolving chair sku : rich/37819/lb/xx, All over size is : 665mm(l)x 500mm(d)x 1090mm(h) , The chair made of full leatherette in black colour .It will comes in matte finsih in contemporary style . Details : Arms : pp arms with pu padding . Use of ply: 12 mm thick hot pressed bwr plywood (is grade - 303 for seat and back) . Seat: 40 ± 2 mm thick polyurethane foam with density 32 (±3) kg per cu meter for best quality cushioning in seat , Back : 40 ± 2 mm thick polyurethane foam with density 32 (±3) kg per cu meter for best quality cushioning in back . backrest support foam design based on symmetrical lumbar support mechanism : knee tilt mechanism. |
| 388 | BACK STORAGE: Supplying and Placing in Potition of arrow back unit back unit storage material : prelaminated particle board/veneer - mdf/steam beech veneer , Back unit size : 1600 mm (l)x 400 mm (d)x 770 mm (h). Colour : red - dark cherry & finish : glossy . Modular back unit top shall be made from 25 mm thick prelaminated particle board/veneer - mdf/steam beech veneer of grade ii type iii of is 12823/latest & confirm to din 68861.iso 9001- 2015. While rest of the sides as well as shelves and shutter to be made up of 18 mm thick prelaminated particle board/veneer - mdf/steam beech veneer p.u. polish. all edges to be provided with same matching veneer edge banding fixed with the hot melt glue. Storage unit with 4 shutters construction is 2 openable doors with 1 fixed shelve + 2 openable doors with 1 fixed shelve , in provided with 2 universal cam lock for security and handles are provided for easy of opening. over all height of product is @ 770 mm |
| 389 | 3 SEATER SOFA: Supplying and Placing in Potition of 3 seater modernist classic design blos/37930 sofa sku : blos/37930/3/l-46 size : 1940mm(l) x880mm(d)x 950mm(h). Material : premium leatherette / style : contemporary colour : brown-eerie black,beige-pebble beige,brown-burnt umber / finish : matte. Supplying and placing three seater exclusive premium leatherette modernist classic design lounge seating sofa size is 1940mm(l) x880mm(d)x 950mm(h) with kiln-dried wood framing makes it warp and scratch resistant,comfortable seat depth & height designed keeping modern indian lifestyle in mind,wrapped in buttery-soft premium leatherette, the panelled back and cushioned armrests encourage lounging,designed with modernity & elegance, choose the option that suits your home. |
| 390 | 1 SEATER SOFA: Supplying and Placing in Potision of 1 seater modernist classic design blos/37930 sofa sku : blos/37930/1/l-46 size : 965mm(l) x880mm(d)x 950mm(h). Material : premium leatherette / style : contemporary colour : brown-eerie black,beige-pebble beige,brown-burnt umber / finish : matte. Supplying and placing single seater exclusive premium leatherette modernist classic design lounge seating sofa size is 965mm(l) x880mm(d)x 950mm(h) with kiln-dried wood framing makes it warp and scratch resistant,comfortable seat depth & height designed keeping modern indian lifestyle in mind,wrapped in buttery-soft premium leatherette, the panelled back and cushioned armrests encourage lounging,designed with modernity & elegance, choose the option that suits your home. Combination construction structure are made in moisture content shall be less than (10-12)%. thickness of plywood used (mm) shall be 12 mm grade is 303 indian standard for commercial (common) and moisture proof plywood |
| 391 | CENTER TABLE:Supplying and Placing in Potition of Scarlet Solid Wood Coffee Table size : (W) 1200mm X (D) 455mm X (H) 460mm. |
| 392 | SIDE TABLE: Supplying and placing in position of Scarlet Solid Wood side Table size : (W) 650mm X (D) 500mm X (H) 460mm. The Scarlet collection celebrates the craftsmanship of skillful Marquetry artisans. Bringing dimension to veneer, checkered patterns travel seamlessly over the tabletop. Stained in dark Oak, the curved solid wood legs makes it a mid-century modern silhouette. Designed to elevate your modern Indian homes. Checkered designer veneer tabletop makes it a timeless accent. Shelf storage offers generous space for books or magazines. Steam Beech wood base makes it highly durable. Easy to clean table stays newer for longer. Made from sustainably sourced Beech wood. 5 years unmatched warranty for hassle free service. |
| 393 | ACCOUNTS/OFFICE/REGISTRATION ROOM/STAFF ROOM |
| 394 | TABLE: Supplying and Placing in Potision of product: director desk stellan sku is stellan/a director table structure of l shaped desk. Primary work surface over all size is 2400mm(l)x 900mm(d)x 750mm(h) 50mm thick table top made of high presure laminate post form with edge banding work surface with postforming edges made of same matte finish. designed modesty pannel with leather patch made of 25mm thick . Provision of side unit of size is 1200mm(l)x 500mm(d)x 740mm(h) ,(combination construction right side table top side unit construction is sliding door with 1 fixed shelve & from left side below table top 1 fixed pedestal . Fixed pedestal of size 450mm(l)x 400mm(d)x 630mm(h) , having 2 equal drawers + 1 filling drawer with in provided with cetnral lock for security and handles are provided for easy of opening. overall construction of pedestal is 18 mm along with fecia of drawers. All the mdf borad are is-14587-1998 with confirm to din 68861.iso 9001- 2015 quality certification confirming to astm d 4499 standards for viscosity and thermal stability . |
| 395 | TABLE: Supplying and Placing in Position of modern design dias table of Size : 3000mm(l)x 750mm(d)x 750mm(h) as per image. Providing & supplying modern design three seater dias table, tabletop offers you a generous workspace,desk primary work surface use premium quality materials over all size is 3000mm(l)x 750mm(d)x 750mm(h)table top made of 36mm thick prelaminated particle board with PVC edges. The understructure shall be made out of 36mm side panel and 18mm modesty panel finished with PVC edges. Our work surface furniture is finished with exposed edges and shall be finished with 2mm thick edge binding tape of matching colour and shade,fixed with hot melt glue. |
| 396 | Supplying and placing in position of high back 360° degre revolving chair sku : rich/37815/hb/xx, All over size is : 590mm(l)x 505mm(d)x 1280mm(h) , the chair made of full leatherette in black colour .It will comes in matte black finish finsih in contemporary style . Details :- Arms : chrome finish arms with pu padding . Use of ply: 12 mm thick hot pressed bwr plywood (is grade - 303 for seat and back) . Seat: 40 ± 2 mm thick polyurethane foam with density 32 (±3) kg per cu meter for best quality cushioning in seat . Back : 40 ± 2 mm thick polyurethane foam with density 32 (±3) kg per cu meter for best quality cushioning in back . backrest support foam design based on symmetrical lumbar support . Mechanism : knee tilt mechanism . Only seat size is 505mm(l)x 505mm(d)x 610mm(h) & the back size is 590mm(l)x 710mm(h) Seat maximum height is 610mm & minimum height is 510mm & back height from floor maximum height is 1280mm & minimum height is 1180mm ; Gas lift 100 mm telescopic haudraulic . Base : 650 mm chrome base with smooth castors |
| 397 | Supplying and placing in position of fix cantilever chair sku : Rich/37816/CN/A, All over size is : 610mm(L)x 505mm(D)x 990mm(H) ,The chair made of full leatherette in black colour . It will comes in matte black finish in contemporary style . Details : - Arms : chrome finish arms with pu padding . Use of ply: 12 mm thick hot pressed BWR plywood (IS Grade - 303 for seat and back) .Seat: 40 ± 2 mm thick polyurethane foam with density 32 (±3) kg per cu meter for best quality cushioning in seat , Back : 40 ± 2 mm thick polyurethane foam with density 32 (±3) kg per cu meter for best quality cushioning in back . backrest support foam , sign based on symmetrical lumbar support backrest support . Only seat size is 610mm(L)x 505mm(D)x 485mm(H) & the back size is 610mm(L)x 540mm(H) , Base : chrome finish tublar frame of cantilever type . |
| 398 | Supplying and placing in position of 3 seater modernist classic design berry/55001 sofa of size : 1905mm(l) x890mm(d)x 870mm(h) as per image. Material : premium leatherette / style : contemporary , colour : black-eerie black-coffee brown,brown-burnt umber / finish : matte. Supplying and placing three seater exclusive premium leatherette modernist classic design lounge seating sofa size is 1905mm(l) x890mm(d)x 870mm(h) |
| 399 | Supplying and Placing in Position of Molly Solid Wood Veneer Coffee Table in Wenge size : (W) 1200mm X (D) 600mm X (H) 460mm. With its epitome of craftsmanship, the Molly collection is destined to become a centerpiece of your modern Indian homes |
| 400 | BOARD ROOM |
| 401 | Supplying and Placing in Potition of 18 seater modern design conference table Material : prelaminated particle board Size : 4800mm(l)x 1800mm(d)x 750mm(h), Colour : brown-wenge / finish : laminated. Providing & supplying modern design ten seater conference table, tabletop offers you a generous workspace,desk primary work surface use premium quality materials over all size is 4800mm(l)x 1800mm(d)x 750mm(h) table top made of 36mm thick which give more surface area for work ,prelaminated particle board,tabletop supported with 75mm thick (6 mm + filler +6 mm) bsl steam beech veneer with sb-8 polish in brown-wenge colour on prelaminated particle board of grade ii type iii of is 12823/latest |
| 402 | Supplying and Placing in Position of rich/37826/hb : high back leatherette chair in black colour with matte finish specification : Durian - office seating - poise chair , Type : High back 360° degre revolving chair sku : rich/37826/hb , All over size is : 640mm(l)x 500mm(d)x 1210mm(h) , The chair made of full leatherette in black colour .It will comes in matte finsih in contemporary style . Details : Arms : fixed chrome finish arms with pu padding . |
| 403 | Supplying and Placing in Position of rich/37826/lb : low back leatherette chair in black colour with matte finish specification : Durian - office seating - poise chair , Type : Low back 360° degre revolving chair sku : rich/37826/lb, All over size is : 625mm(l)x 490mm(d)x 1135mm(h) , The chair made of full leatherette in black colour . It will comes in matte finsih in contemporary style . |
| 404 | CLASS ROOM |
| 405 | Supplying and Placing in Potision of product: office desk capital sku is capital office desk desk structure of rectangular shape . Primary work surface over all size is 1200mm(l)x 500mm(d)x 750mm(h) 18mm thick table top made of prelaminated particle board with metal pedestal work surface with the exposed edges shall be finished with 2mm thick edge binding tape of matching colour and shade with the hot melt glue . understructure made of ,metal-ms metal powder coated color with understructure 25mmx1.2mm rd. pipe.all metallic parts should be epoxy polyester powder coating to thickness of 50 micron (approx). Right side fixed pedestal 350mm(l)x 499mm(d)x 735mm(h) |
| 406 | Supplying and placing in position of fix cantilever back supported powder coated fix cantilever frame chair with all over size is : 520mm(L) x 470mm(D) x 930mm(H) . The chair made of full fabric in black colour .It will comes in matte finsih in contemporary style . Details :- Arms : fixed armrest padded armrest.; Use of ply: 12 mm thick hot pressed bwr plywood (is grade - 303 for seat and back) ; Seat: 40 ± 2 mm thick polyurethane foam with density 32 (±3) kg per cu meter for best quality cushioning in seat ; Back : 40 ± 2 mm thick polyurethane foam with density 32 (±3) kg per cu meter for best quality cushioning in back . backrest support foam design based on symmetrical lumbar support . |
| 407 | Benches for Primary Sections |
| 408 | Benches for Junior Sections |
| 409 | Benches for Primary Sections |
| 410 | Bill of Qty |
| 411 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on inter-locking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6 mm reveal profile (white/ black),comprising of main-T runners of size 15x42 mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary ntermediate cross-T of size 15x42 mm of length 600 mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge |
| 412 | IP 4MPX Colour night vision cameras |
| 413 | Networking of cameras |
| 414 | Cat-6 Wire Dlink |
| 415 | Network Video Recorder 16 Channel |
| 416 | Surveillance Harddrive 8/6 Tb |
| 417 | Wiring Charges |
| 418 | Wiring Clips/Clamps and all Accessories |
| 419 | Installation/commissionning of ip cameras |
| 420 | POE Box |
| 421 | U6 Networking Rack |
| 422 | Camera Housing |
| 423 | Cat-6 Connectors |
| 424 | 43'' Monitor for viewing |
| 425 | VIDEO SOLUTION |
| 426 | SITC of Indoor Led Display |
| 427 | Parameter + Specifications |
| 428 | Display Size 5120mm x 2560 mm |
| 429 | Pixel Pitch 2.5mm or less |
| 430 | Surface Coating Glue on Board |
| 431 | LED Configuration SMD 3 in 1 |
| 432 | Pixel Density 160000 Pix / Sq-Mtr or More |
| 433 | Half Gain Horizontal / Vertical Viewing Angle H 160 deg / V 160 deg or better |
| 434 | Refresh Rate ≥ 3840 Hz or better |
| 435 | Contrast Ratio 5000:1 or better |
| 436 | Gray Scale Processing 16 Bit or better |
| 437 | Dimming Capability 256 levels |
| 438 | Cabinet Material Die Cast Aluminium / Carbon Fibre / Magnesium Alloy/Mild |
| 439 | Cabinet Type Fan-less Design |
| 440 | Screen Depth (exclusive of structure) 125mm or less |
| 441 | Weight kg/ m2 32kg/m2 or less |
| 442 | Brightness (calibrated) 800 cd/m² or higher |
| 443 | Maximum Power Consumption (during LED startup) 700 w/sqm or lower |
| 444 | Average Power Consumption 300 w/sqm or lower |
| 445 | Power Input 100 ~ 240 VAC |
| 446 | Temp Range 0 to +40 Degrees C or better |
| 447 | Access For Maintenance Front Service only |
| 448 | IP Level IP20 Front and Back |
| 449 | Compliance Certification on OEM Name CE, FCC, BIS; Certifications are mandatory |
| 450 | Warranty 3 Years OEM’s Warranty certificate. |
| 451 | SITC of LED Controller |
| 452 | Parameter |
| 453 | Pixel Capacity 9.5 Million or More |
| 454 | LED Output 16x Ethernet |
| 455 | Input 3 x HDMI , 2x DVI,2 xDP,SDIx2 |
| 456 | Output 1xDP,1xDVI |
| 457 | Operating Temperature 0℃ ~ 50℃ |
| 458 | Maximum Power Consumption 100 W or less |
| 459 | SITC of Wall mount structure |
| 460 | SITC of Installation and programming charges |
| 461 | AUDIO SOLUTION |
| 462 | SITC of Indoor Led Display |
| 463 | Parameter + Specifications |
| 464 | Display Size 5120mm x 2560 mm |
| 465 | Pixel Pitch 2.5mm or less |
| 466 | Surface Coating Glue on Board |
| 467 | LED Configuration SMD 3 in 1 |
| 468 | Pixel Density 160000 Pix / Sq-Mtr or More |
| 469 | Half Gain Horizontal / Vertical Viewing Angl e H 160 deg / V 160 deg or better |
| 470 | Refresh Rate ≥ 3840 Hz or better |
| 471 | Contrast Ratio 5000:1 or better |
| 472 | Gray Scale Processing 16 Bit or better |
| 473 | Dimming Capability 256 levels |
| 474 | Cabinet Material Die Cast Aluminium / Carbon Fibre / Magnesium Alloy/Mild |
| 475 | Cabinet Type Fan-less Design |
| 476 | Screen Depth (exclusive of structure) 125mm or less |
| 477 | Weight kg/ m2 32kg/m2 or less |
| 478 | Brightness (calibrated) 800 cd/m² or higher |
| 479 | Maximum Power Consumption (during LED startup) 700 w/sqm or lower |
| 480 | Average Power Consumption 300 w/sqm or lower |
| 481 | Power Input 100 ~ 240 VAC |
| 482 | Temp Range 0 to +40 Degrees C or better |
| 483 | Access For Maintenance Front Service only |
| 484 | IP Level IP20 Front and Back |
| 485 | Compliance Certification on OEM Name CE, FCC, BIS; Certifications are mandatory |
| 486 | Warranty 3 Years OEM’s Warranty certificate. |
| 487 | SITC of LED Controller |
| 488 | Parameter |
| 489 | Pixel Capacity 9.5 Million or More |
| 490 | LED Output 16x Ethernet |
| 491 | Input 3 x HDMI , 2x DVI,2 xDP,SDIx2 |
| 492 | Output 1xDP,1xDVI |
| 493 | Operating Temperature 0℃ ~ 50℃ |
| 494 | Maximum Power Consumption 100 W or less |
| 495 | SITC of Wall mount structure |
| 496 | SITC of Installation and programming charges |
| 497 | AUDIO SYSTEM |
| 498 | SPEAKERS AND AUDIO FUNCTIONING CONTROL |
| 499 | SITC of Installation and control charges |
| 500 | LED PARrgbw54 LEDs 3W 4 digital display. There dimmer manual mode, running, strobe, speed adjustable, adjust the data with a power saving, boot automatically recover data. DMX 512 protocol - 6 DMX channels Main dimmer , RGB color changing , Strobe effect, Auto play with internal programs , Master/Slave function, Stand alone mode . Power supply: AC 100V-AC240V 50/60 Hz. Light power connect maximum range 15pcs to 30pcs. Consumption: 160W |
| 501 | LED PARSupply of 54LEDs 3W 15° (Warm white) portable, lightweight luminaries, high intensive light with low heat output, Very robust luminaries, suitable for indoor Public and commercial buildings, Music festivals, stadiums, theme parks, Stages, Exhibition halls. digital display, no fan required, light output: 4,200 lm , Up to 16.7 million colors, Dimming range: 0...100 % built-in control of statics, auto, sound,DMX512 monitoring, Strobe effect, Lifetime: up to 30,000 h with beam angle: 15°, 30°, 45°, 60°, IP20. Auto play with internal programs, aster/Slave function, Standalone mode. Power supply: AC 100V-AC 240V 50/60 Hz. Light power consumption: 162W. |
| 502 | 200W LED Profile Spot 19 Degree Light 200W LED Profile Spot 19 Degree Light complete with 3200K CCT Colour Tempreture, CRI & TLCI above 90, DMX512 dimming with 1or3 channel modes, Black finish housing IP20 protection having Lux@2 Mtrs above 27,000 suitable to illuminate the key presenter or talent on stage. |
| 503 | LED Moving Head Spot- 230W . LED Moving Head Spot-230W, Pan Range-540* & Tilt Range-180*, 8 Bit/16 Bit High Precision Movement, 1 Static Gobo Wheel-7 Fixed Metal Gobos, Motorized Zoom from 12* ~ 18*and complete as per direction of Engineer-In-Charge complete etc as reqd. |
| 504 | Blinder :4-Eyes white & warm white High-Power Warm white LED COB Lamps: 4 x 100W (400w) Optics: 80 degreeWide Flood Individual control of 2-EyesDMX operation – with 10 DMX channels Wireless DMX ready – using special 3-Pin XLR socket with 5vdc Vertically & Horizontally expansion possible to build 4/8-way or more… Possible to create larger MATRIX for Pixel mapping effects. Powercon IN & OUT for mains (supplied with 1xMains & 1xLink cables) Power: 90 – 260VAC – 50/60 Hz, 220 |
| 505 | DMX Splitter Supply and fixing of 1 in 8 Out DMX Splitter. |
| 506 | Light PointLight Point Wiring from Patch panel/ Distribution Board to be provided near stage to various stage light fixtures with1.5sq.mm 3core PVC Insulated and PVC sheathed Cable (ISI Mark) including 15amp socket to direct points with box at top. |
| 507 | Light Bar: Providing and Fixing of 42mm dia ms pipe light bar |
| 508 | Mini Pearl Lighting Controller2.Voltage:AC 110V-240V/50~60Hz. N.W(1piece):14 Kg Size(1piece):550×460×350 mm. Mini pearl 1024 can control 96fixtures at the same time. The controller can read the pearl's fixture library format(r20) Inside dozens of effect shapes,also can running 10 scenes |
| 509 | DMX interconnection cable |
| 510 | Light Clamp |
| 511 | Smoke machine |
| 512 | Add Lift (16 Persons) |
| 513 | CONSTRUCTION OF TUBE WELL |
| 514 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All Types of Soil 350 mm dia |
| 515 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. Rocky strata including Boulders 350 mm dia |
| 516 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. |
| 517 | 150 mm nominal size dia having minimum wall thickness 5.00 mm |
| 518 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. |
| 519 | 200 mm nominal size dia |
| 520 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 521 | Around Pipe (3.14*0.15*0.15*150.00) |
| 522 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 523 | (3.14*3.50*3.50*0.30) |
| 524 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 525 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: |
| 526 | 150 mm dia |
| 527 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. |
| 528 | 150 mm dia |
| 529 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I). |
| 530 | 150 mm dia |
| 531 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. |
| 532 | 80 mm dia nominal bore |
| 533 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 10 x 4 sq. mm |
| 534 | Supplying & installation of pumping motor pumpset ISI marked, making connection suitable for tube-well/D.C.B. The job includes screwing and welding of flanges on G.I. riser pipes (65 mm dia minimum) installation, complete fittings accessories with riser pipes jointing of electrical cables other connections making switch board electrical connections, all labour for testing of pumpset and supply of water to water mains complete in all respects. |
| 535 | PUMP HOUSE |
| 536 | Cost of Lan Network complete in all respect as per direction of engineer in charge |
| 537 | Directorate Building (PART B) |
| 538 | EARTHWORK |
| 539 | Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. |
| 540 | FILLING |
| 541 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 542 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. |
| 543 | PCC WORK |
| 544 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 545 | ANTI- TERMIDE |
| 546 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground. floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment of soil along external perimeter of building 7.5 liters/sqm. (5) Treatment of soil under apron along external perimter 5 liters/sqm. |
| 547 | DAMP PROOF COURSE |
| 548 | Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 549 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 550 | RCC WORK |
| 551 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. |
| 552 | Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 553 | RCC work in foundation and column |
| 554 | All works above plinth level upto floor V level |
| 555 | RCC work in column beam and slab |
| 556 | BRICK WORK |
| 557 | M-150 brick work in one cement & six coarse sand 2.25 F.M. mortar in foundation and plinth including supply of all materials labour, tools and plants etc. required for proper completion of the work. |
| 558 | M-150 Brick work in super-structure above plinth level up to floor two level (up to two storeys) including necessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:4 cement & coarse sand) |
| 559 | Same as in item no. 10 but in 1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. |
| 560 | WATERPROOFING TREATMENT |
| 561 | Providing & laying \\"brick Coba\\" 120mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrylic cement concrete water proofing compound filled gaps of |
| 562 | coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono lythic plaster wall upto 30cm higher and junction and corner shall be rounded by brick |
| 563 | ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour T & P etc complete for proper completion of work. |
| 564 | DOOR/WINDOW /VENTILATOR |
| 565 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 566 | (a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 567 | (b) Add extra for Double leaf shutter |
| 568 | Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) |
| 569 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. |
| 570 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 571 | Door / windows & Staircase grill. |
| 572 | Sypply & fixing of Z-section steel windows |
| 573 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 574 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. |
| 575 | Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 576 | Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R3 series with frame (98 mm & above) x (40 mm & above) & both glazed and fly screen sash (30 mm & above) x (55 mm & above) with zinc alloy (Zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m). |
| 577 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 578 | Providing and Fixing factory made uPVC door frame, made of uPVC exturded sections, of size 65 mm x 55 mm with wall thickness 2.0 mm (+ 0.2 mm), corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mm x 30 mm having wall thickness 2 mm (+0.2 mm), including providing & fixing 3 nos of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number & size of anchor dash fastners, all complete as per manufacturer’s specification and direction of Engineer-in-charge. |
| 579 | Providing and fixing 37 mm thick factory made PVC door shutter, styles and rails made of PVC hollow section of size 100 mm x 37 mm with wall thickness 2 mm (+ 0.2 mm), with inbuilt bead on one side, styles and rails mitered cut and joint at the corners by means of 2 nos of plastic brackets of size 75 mm x 220 mm at each corner and stainless steel screws, reinforcing the hinge side of style by inserting PVC profile of size 28 mm x 30 mm, with wall thickness 2 mm (+ 0.2 mm). Lockrail of size 100 mm x 37 mm, wall thickness 2 mm (+ 0.2 mm) will be fixed to the vertical styles. Providing with PVC snapfit beads and panel of size 100 mm x 20 mm, and inserting 2 nos tie bar of 6 mm dia and fastening with nuts and washers complete, all as per manufacturer’s specification and direction of Engineer-in-charge. |
| 580 | TMT FE-500 or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. |
| 581 | Fixing of Door, windows/ventilators chaukhats in position. |
| 582 | (a) Door |
| 583 | (b) Windows |
| 584 | (c) Ventilator chaukhats |
| 585 | 15 mm plinth plaster (1 cement :4 coarse sand) |
| 586 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1) 1 cement : 6 coarse sand. |
| 587 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand |
| 588 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 589 | 40 mm thick 1:2:4 plain cement concrete floor (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement. |
| 590 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Light shade pigment using white cement |
| 591 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the approved make & colours) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 592 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm |
| 593 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick. |
| 594 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 595 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. (Area of slab upto 0.50 sqm) |
| 596 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 597 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 598 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 599 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 600 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 601 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 602 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (Ceiling) |
| 603 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand & anufacturer, over the plastered wall surface to prepare the surface even & smooth complete. |
| 604 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 605 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : (a) 250mm x 16mm . |
| 606 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete: |
| 607 | (a) 250 mm x 10mm |
| 608 | (a) 200 mm x 10mm |
| 609 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : (a) 125 mm |
| 610 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 611 | Making of drain along with apron (Size 150*150mm) |
| 612 | Supply & filling of cinder in sunken portion of building including braking in to required sizes including supply of all material, T&P required size including of supply of all material , labour, T&P required for proper completion of work. |
| 613 | Providing and laying water proofing treatment in sunken portion of W.C., bathroom etc, by applying cement slurry mixed with water proofing cement compound consisting of applying :- (a) First layer of slurry of cement @ 0.488 Kg/Sqm mixed with water proofing cement compound @ 0.253 kg/Sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 Kg/Sqm mixed with water proofing cement compound @ 0.126 kg/Sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 614 | Expension joint teatment with 2 mm thick aluminium sheet and 4 cm thick bitumastic sheet with hot bitumen of approved aulity. (As per Rate analysis & specification attached) HORIZONTAL EXPANSION JOINT |
| 615 | Providing & fixing aluminium sheet 2 mm thick for Vertical expansion joint work including labour and all materials etc . Powder coated aluminium (minimum thickness of powder coating 50 micron) VERTICAL EXPANSION JOINT |
| 616 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 617 | (a) Foundations, footings, bases of columns, etc. for mass concrete |
| 618 | (b) Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
| 619 | (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 620 | (d) Columns, Pillars, Piers, Abutments, Posts and Struts |
| 621 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on inter-locking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6 mm reveal profile (white/ black),comprising of main-T runners of size 15x42 mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary ntermediate cross-T of size 15x42 mm of length 600 mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge |
| 622 | Providing and fixing of façade at all heights with extruded hollow Clay / Terracotta ventilated rainscreen tiles of height 259/ 309/ 409 mm and lengthof 1190 mm of approved texture,design and pattern having Flexural Strength/ Modulus of Rupture of ≥ 14 N/m² and maximum water absorption of 10% tested as per ISO 10545-4:2004(E) and ISO 10545-3:1995 respectively in true level fixed to a supporting aluminium framework (Alloy 6063 T5/T6) consisting of vertical ‘T’ (for intermediates)/ ‘L’ (for ends/ termination)/ Tubular sections (at corners)of size 80x60x2 mm/ 40x60x2 mm/ 40x40x2 mm respectively, spaced at maximum spacing of 1200 mm c/c matching to the tile vertical grid, and horizontal aluminium ‘C’-clamps of size 56x34x2 mm thickness of length 150 mm at junction of tiles and of length 75 mm at wall ends/ corners fixed on top of the vertical sections at spacing of 250/ 300/ 400 mm c/c matching to the tile horizontal grid with two numbers of self-drilling / self-tapping SS screws of size 5.5x25 mm with EPDM washers. The vertical ‘T’/’L/ Tubular’ sections shall be fixed to the wall using HDG (hot-dip-galvanized) steel L-brackets (galvanizing thickness of minimum 80 microns) of size 110x80x6 mm at intermediate vertical aluminium profiles and of size 220x110x12 mm at outer corners and stainless steel grade 304,M10 full threaded anchor fasteners with nylon sleeve 100 mm long (for brick work) and M8 expansion anchor fasteners 75 mm long for concrete surface, spacing of brackets to be based on a structural/ static calculation. The brackets shall be of length 175 mm at junction of two vertical aluminium profiles and of length 100 mm at intermediate points of vertical profiles and shall be fixed to the vertical aluminium T / L / Tubular profiles using two numbers self-drilling/ self-tapping SS screws of size 5.5x25 mm with EPDM washers. EPDM gaskets to be fixed in between brackets and vertical profiles. The tiles shall be mounted on the ‘C’ clamps such that the tiles are supported at top and bottom at both ends. The tiles shall be mounted on the C-clamps with EPDM profiles in between such that the tiles are supported at top and bottom at both ends |
| 623 | With 24 mm thickness (+/- 10%) terracotta tiles of other than grey colors |
| 624 | Providing and fixing glass reinforced cement panels |
| 625 | Providing and fixing glass reinforced cement shikhar |
| 626 | small size |
| 627 | large size |
| 628 | Finishing wall with rustic, stone, and smooth finishes on the surface such as a wall, involves a process of surface preparation, material application, and achieving the desired texture. This process typically includes cleaning the surface, applying a primer, mixing the texture coating, applying the coating, and allowing it to dry. Specific techniques and tools, like trowels, rollers, or sprayers, are used to create the desired texture.specification are primer sealed (MS sealed) should be 25 to 50 micron, texture paint(megatext) should be 1 mm min & top coat (dulux inspire exterior) should be 25 to 50 micron |
| 629 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. |
| 630 | BILL OF QUANTITY |
| 631 | INTERNAL ELECTRIFICATION WORK) |
| 632 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 633 | Group - C |
| 634 | Wiring for group controled (looped) light point/ fan point/ exhaust fan point/ call bell point (without independent switch etc) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 635 | Group - C |
| 636 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 637 | Wiring for light/power plug with 2x4 sqmm FRLS PVC insulated copper conductor single core cable in suface / recessd medium class PVC conduit along with 1 no 4 sqmm FRLS insulated copper condutor alongwith 2 nos 4sqmm FRLS PVC insulated copper conductor single core cable for loop earthing as required . |
| 638 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 639 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 640 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 641 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 642 | 2 X 6 sq. mm + 1 X 4 sq. mm earth wire |
| 643 | 4x10 sq. mm + 2x6 sq. mm earth wire |
| 644 | 4x16 sq. mm + 2x6 sq. mm earth wire |
| 645 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 646 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 647 | Supplying and drawing following pair 0.5 mm dia FSRL PVC insulated annealed copper conductor , unarmed telephone cable in the existing conduit.as required |
| 648 | Supplying and drying co-axial TV cable RG 6 grade 0.7 mm solid copper conductor PE insulated shielded with fine tinned copper braid and protected in existing conduit |
| 649 | Supply and lay PVC Conduit medium size of following sizes |
| 650 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excludingmodular plate etc. as required. |
| 651 | RJ 55 cat 6 with shutter |
| 652 | Telephone socket outlet |
| 653 | TV antenna socket outlet |
| 654 | Bell push |
| 655 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 656 | Supplying and fixing following module GI box with moduler base and pleate with plate cover |
| 657 | 1 or 2 modules |
| 658 | Supply and fixing suitable GI Box with moduler plate and cover in front on surface for fixing of 3 pin 5/6 amp moduler socket out let with moduler switch |
| 659 | Supply and fixing suitable GI Box with moduler plate and cover in front on surface for fixing of 6 pin 15/16 amp moduler socket out let with moduler switch |
| 660 | Installation , Testing and commissioning of wall /celing fitting of all sizes and shape containing up two GLS/ CFL/ LED lamp per fitting etc as required |
| 661 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 662 | Supplying and drying of UTP 4 Pair Cat 6 Lan Cable |
| 663 | 1 run of cable |
| 664 | Supply and fixing suitable size GI box with moduler plate and cover in front on surface or in recess including providing and fixing 2 nos 3 pin /6 amp moduler socket out let and 2 nos 5/6 a moduler switch all as directed in non residencial building |
| 665 | Supply and fixing suitable size GI box with moduler plate and cover in front on surface or in recess including providing and fixing 25 A moduler socket out let and 25 A moduler SP MCB including connection etc |
| 666 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 667 | 4 Way (4+12) Double door |
| 668 | 6 Way (4+18) Double door |
| 669 | 8 Way (4+24) Double door |
| 670 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 671 | Single pole |
| 672 | Double pole |
| 673 | Triple pole and neutral |
| 674 | Supply and fixing following rating double pole Single phase |
| 675 | 25 Amp |
| 676 | 63 Amp |
| 677 | Supply and fixing 63 Amp four pole (three Phase) |
| 678 | Supply and fixing 40/63 Amp four pole 10 ka c curve (three Phase) |
| 679 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 680 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 681 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 682 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 683 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 684 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required |
| 685 | Supplying and laying 25 mm X 5 mm Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 686 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 687 | Supplying and laying 25 mm X 5 mm Copper strip in 40 mm gi pipe from earth electrode including connection with brass nut, bolt spring washer excavation and refilling etc . |
| 688 | Supplying and laying 25 mm X 5 mm GI strip in 40 mm gi pipe from earth electrode including connection with brass nut, bolt spring washer excavation and refilling etc . |
| 689 | Supplying and laying 25 mm X 5 mm GI strip on surface for connection etc. |
| 690 | Supplying and laying 6 SWG GI wire for loop earthing . |
| 691 | Supply, fixing and testing round / squre 12/15 watt LED light fitting surface / flush type fitting including all accessories for fixing all as directed at site |
| 692 | Supply, fixing and testing round / squre 8/10 watt LED light fitting surface / flush type fitting including all accessories for fixing all as directed at site |
| 693 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 694 | supply fix and testing of water tight light 10 watt LED having pressure die cost housing with driver set cinfirming to IP 67 and above protection ,high purity yellowish difuser / reflector and detacheble driver set suitable for contineous opration complete in all respect |
| 695 | supply fixing and testing complete LED Batten Light 18/22 watt lumen efficiency >135 lm /watt powder coted |
| 696 | Supply and fixing of 36 Watt to 40 Watt indoor FLUSH/SURFACE LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect.(CAT AAA) |
| 697 | Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed |
| 698 | Recessed PIR Motion Sensor |
| 699 | Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required. 300mm EXHAUST FAN |
| 700 | Supplying. installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as peris. 10322 with drive as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , FRLS, PVC insulated copper conductor single core cable and earthing etc. as requiredLED Down Lighter SMD Type of Following Cap and Lumen Level >135 Ln |
| 701 | P. F.20.95, IP20, CRI>80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), tife time (LED,Driver & electrical circuitry). ife time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained illi le ends as per LMan extrapolation IES TM-21-1 1 report, CCT 3000'K /4000\\"K 5700\\"K/ 6000\\"K /6500\\"K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should nfot more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark' Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/ic connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as requiredLED Down Lighter SMD Type of Following Cap and Lumen Level >135 Ln |
| 702 | with Minimum 5 year OEM warranty. System lumen efficacy >135 Im/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shalbe as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). of following watts |
| 703 | 8 / 10 watt LED |
| 704 | 12/15 watt LED |
| 705 | ON LINE UPS :- Input supply 3 phase Output Supply : 3 Phase Supplying- installation,| Testing Commissioning of of following capacity at fullioad (Unity Power Factor) at operating temperature 0 to 40 deg C. Relative humidity 0 to 95%, Online double conversion true sine wave Uninterrupted hot swappable (fallow for the replacement or_addition of battery modules without shutting down the ertire system) modular Power Supply(UPS)system with N+1modules (N denotes total numberof moduels requird for rated capacity). The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Batlery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch alongwith provision for manual bypass, suitable isolation transformer for additional protection against neutral fauits etc. |
| 706 | UPS shall have inbult phase sequerce correction. he UPS systems offered are to be of the latest technology with Digital Control Microprocessor based for reliable operation using nasulated Gate Bipolar Transstor (IGBT)'s both for the rectifier & inverter(3 Level) with PWM (Pulse Width Modulation) The quality ofdesign. manufacturing and inspection process should confirm to the relevant inter- national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be -96%% while operating jon battery mode and delivering t a quality power to the 100% non-linear loads. |
| 707 | Current total harmonic effect(iTHD) on the inputgrid shallbe < 5% at 50%load. (Therequired LC( inductor (L) and a capacitor (C) fiters shall be included in UPS cost), extreme power tactor kit to be included to lim it the input power factor (PF) to 0.99 and output power factor shall be unity (i. e. kw rating of the UPS shallbe kvaratingx 1), howeverUPS.shallbe suitabletotake loadat0.7 lagingto0.7 leading power factor loads _ UPS shallb suitable for incoming supply AC : 3Phase 400V +/-20% 50 HZ +-5 HZ, AC Output voltlage: 3Phase 415 Volt, 50 Hz +1- 0.2Hz, Overload capacity of 120% for 10 mins, Sine wave output |
| 708 | Non condensing, noise levelless than60dbat 1 meterdistance, protectione- input Under voltage over voltage. abnormal out voltage, battery over 'charging, output over current, short circuit protection, battery deep idischarge protection, 10KV surge. UPS must comply with low voltage electromagnetic compatibilty (EMC)achieved as Denw 6204,EN6204 Part 1 and Part 2, tfshallbe a Voltage and Frequency Independent VFI)-type UPS. Communication RS232/RS485/SNMP port open protocol for BMS integration., all hardware & software for iOT Communication as per approved by Engineering in charge. |
| 709 | Required battery racks and interconnecting copper conductor cables of suitable size and connectors and all required accoseries are inclusive of the cost). This system must provide a means for logging and alarming of all onitored points plus email notification, Forced air-cooling with integral inbuiltl fans with redundancy (if one fan fall UPS should be able to handle at least 80% the joad. Noise Level 65 DB at 1 mf meter distance The system shall be in compliance IEC 62040- 1,2 & 3,IS: 16242 and CPVD Specification. |
| 710 | Display Panel (minimum) (In-build S inch or more LC Display/ LED ) to display a) input: Voltage, current Frequency. b) Bypass:|Voltage, Frequency. c)Output Voltage, frequency. Current.d) Battery: Voltage, Capacity. e) Load: KVA, KW, Percentage, fTemperature: STS, Inverter, PFC. g) Event Logging & Statistical Data (On LCDÆLED) UPS should capture and display up to 3000 events like: Over temperature / DC Bus Fail/ Fan Fail / Fuse Fail / Overtoad / Short-circuit / Device Fail / Inverter Fail / Rectifier Fail/ Bypass Fail, etc. h) Statistical Data: No. of power failures / Transfers to Bypass / Total Running time, etc. |
| 711 | i) Mains Mode of Operation /Battery Mode of Operation / Bypass feeding the load / UPS Fault /Battery charging and discharging, overload, battery voltage and battery capacity. j) Audible Alarms: Mains Failure, Battery Low Alarm, UPS Overioad, Faut, Shutdown, Input Over, Under Voltage, Output Over, Under Voltage, Battery Over, Under Voltage, Over Load and short circuit, Over Temperature. The UPS should have OR code which should contain drawing, testreport OEM manual,Geo- Tag of manufacturing location etc. |
| 712 | 40kva (Each power Module shall be < 10KVA) |
| 713 | SUBHEAD: - V : EARTHING |
| 714 | HT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad switchgear complete with Vacuum Circuit Breaker having rupturing capacity 250 MVA, overload and earth fault protection, ammeter, voltmeter and of rating upto 400 Amp. → for 11 KV incoming |
| 715 | Main Panel |
| 716 | SITC of LT swith gear panel suitable for 433 volt 3 phase 4 wire system use all draw out relese type type breaker as following |
| 717 | Incoming:- |
| 718 | 1 Nos 1600 amp TPN EDO ACB microprossesor based 25 Ka having s/c, o/c and earth fault relay |
| 719 | 2 nos 800 amp TPN EDO ACB 25 KA |
| 720 | BUSCOUPLER |
| 721 | 1 no 800 Amp TPN EDO ACB 25 KA |
| 722 | BUSBAR:- |
| 723 | 3 nos 2000 Amp and ! Nos 1000 amp bus bar o alluminim. |
| 724 | Auto opration of in coming / Buscoupler ACB by load manegement through PLC |
| 725 | Contactor gor load manegeent System |
| 726 | Auto Change over. |
| 727 | Buscoupler switchingElectrical and mechenical inter locking |
| 728 | OUT GOING :- |
| 729 | 1 no 800 Amp TPN EDO ACB 25 KA |
| 730 | 1 no 600 Amp TPN EDO ACB 25 KA |
| 731 | 4 nos 160 amp Fp MCCB |
| 732 | 2 nos 400 amp Fp MCCB |
| 733 | 2 nos 125 amp Fp MCCB |
| 734 | 6 Nos 63 Amp MCCB |
| 735 | Main Bldg LT Panel |
| 736 | SITC of LT swith gear panel suitable for 433 volt 3 phase 4 wire system use all draw out relese type type breaker as following |
| 737 | Incoming:- |
| 738 | 1 nos 400 amp MCCB 16 Ka havin s/c. E/F and O/l relays |
| 739 | BUSBAR:- |
| 740 | 3 nos 500 Amp and 1 Nos 250 amp bus bar of alluminim.alies |
| 741 | OUT GOING :- |
| 742 | 1 nos 400 amp FP MCCB 10 ka |
| 743 | 5 Nos 125 Amp FP MCCB 10 Ka including all type of protection relays |
| 744 | Office Bldg Floor Light LT Panel |
| 745 | SITC of LT swith gear panel suitable for 433 volt 3 phase 4 wire 50 HZ AC system use all draw out relese type type breaker as following |
| 746 | Incoming:- |
| 747 | 1 nos 125 amp FP MCCB 16 Ka havin s/c. E/F and O/l relays |
| 748 | BUSBAR:- |
| 749 | 1 set of 200 Amp and bus bar of alluminim.alies |
| 750 | OUT GOING :- |
| 751 | 7 nos 63 amp FP MCCB |
| 752 | Main Bldg LT Panel |
| 753 | SITC of LT swith gear panel suitable for 433 volt 3 phase 4 wire system use all draw out relese type type breaker as following |
| 754 | Incoming:- |
| 755 | 1 nos 400 amp MCCB 16 Ka havin s/c. E/F and O/l relays |
| 756 | BUSBAR:- |
| 757 | 3 nos 500 Amp and 1 Nos 250 amp bus bar of alluminim.alies |
| 758 | OUT GOING :- |
| 759 | 1 nos 400 amp FP MCCB 10 ka |
| 760 | 5 Nos 125 Amp FP MCCB 10 Ka including all type of protection relays |
| 761 | Supply of Power Cable Solid Aluminium conductor up to 10 sqmm |
| 762 | 6 sqmm 2 core |
| 763 | 16 sqmm 4 core |
| 764 | 25 sqmm 3.5 core |
| 765 | 70 sqmm 3.5 core |
| 766 | 95 sqmm 3.5 core |
| 767 | 300 sqmm 3.5 core |
| 768 | Supply and making end termination with with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1100 volt grade |
| 769 | 6 sqmm 2 core |
| 770 | 10 sqmm 4 core |
| 771 | 16 sqmm 4 core |
| 772 | 25 sqmm 3.5 core |
| 773 | 35 sqmm 3.5 core |
| 774 | 70 sqmm 3.5 core |
| 775 | 95 sqmm 3.5 core |
| 776 | 300 sqmm 3.5 core |
| 777 | Laying of1 no PVC insulated and PVC shethed / XLPE |
| 778 | Above 185 and and up to 400 sq mm |
| 779 | up to 35 sq mm clamped with 1 mm thick saddle |
| 780 | Above 35 sq mm up to 95 clamped with 1 mm thick saddle |
| 781 | Above 185 and and up to 400 sq mm |
| 782 | Supply fixing of RCC Pipe NP2 class |
| 783 | Supply layin of DWC HDPE Pipe 200 mm dia |
| 784 | Supply and Fixing of 7 Meter octogonal Pole |
| 785 | Supply and fixin of LED light fitting almn body |
| 786 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 787 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required |
| 788 | Supplying and laying 25 mm X 5 mm Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 789 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 790 | Supplying and laying 25 mm X 5 mm Copper strip in 40 mm gi pipe from earth electrode including connection with brass nut, bolt spring washer excavation and refilling etc . |
| 791 | ADDRESSABLE FIRE DETECTION & ALARM SYSTEM |
| 792 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessedconduit as required.(rate taken from internal electrical DSR) |
| 793 | 25 mm dia. |
| 794 | Supplying, installation, testing & commissioning of heat detector operating at 54°C/57°C with rate of rise cum fixed tempreature (dual thermistor) type with mounting base complete with all connection etc. as required. |
| 795 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 796 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 797 | Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. |
| 798 | Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required.6 zone panel for fire alarm system100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required- 2 Nos. (one to act as standby)Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set.Announcement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set.Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFFswitch, fuse visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch -1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt, 30 AH each sealed maintenance free batteries -1 set. |
| 799 | Supplying instalation testing & comisioning of exit point directional sound speaker with voice and integral audio amplifier with selectable sound pulse patterns complete as required |
| 800 | supplying and laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000v rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 801 | PUMP (A) Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required:(B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.(C) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(D) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(E) Suitable cement concrete foundation duly plastered with anti vibration pads. |
| 802 | 1620 lpm at 56 m Head |
| 803 | (A) Supplying, installation, testing and commissioning of diesel enginedriven main fire pump suitable for automatic operation and consistingof following, complete in all respects, as required : (Diesel DrivenPump)(B) Horizontal type, multistage, centrifugal pump of cast of iron bodyand bronze impeller with stainless steel shaft, mechanical sealconforming to 1520.(C) Suitable HP, 1500 RPM water cooled with radiator, diesel engineconforming to relevant IS standard complete with auto startingmechanism, 12 /24 volts electric starting equipment, diesel tank,exhaust pipe extended upto 10 m outside pump house duly insulatedwith 50 mm thick glass wool with 1.0 mm thick aluminium sheetcladding, residential silencer, instruments and protection as perstandard specification, stop solenoid for auto stop in the event of faultwith audio indications, painted with post office red colour etc. as required.(D) M.S fabricated, common base plate, coupling, coupling guard,foundation bolts etc. as required.(E) Suitable cement concrete foundation duly plastered and with antivibration pads. |
| 804 | 1620 lpm at 56 m Head |
| 805 | (A) Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Jockey Pump)(B) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS: 1520.(C) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS: 325.(D) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(E) Suitable cement concrete foundation duly plastered and with antivibration pads. |
| 806 | 300 lpm at 56 m Head |
| 807 | (A) Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS: 1520(C) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(D) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(E) Suitable cement concrete foundation duly plastered and with anti vibration pads. |
| 808 | 450 lpm at 35 m Head |
| 809 | Controle panel |
| 810 | Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears andaccessories, mountings and internal wiring, earth terminals,numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : |
| 811 | INCOMING250A, 50kA 4 Pole MCCB, Ics=100% Icu ratingDigital Voltmeter 0-500V with selector switchDigital Ammeter (0-250 A) with selector swtich & CTs etc.LED type RYB phase indicating lamps, ON, OFF, trip indicating lampsSet of Copper Bus Bar 300AOUTGOING(Note: All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)MAIN FIRE PUMP125 A, 50KA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.JOCKEY PUMP63 A, 50KA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROLControl for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indicationBattery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC AmmeterAll standard relays and accessories for automatic operation of diesel engine |
| 812 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: |
| 813 | 25 mm dia |
| 814 | 32 mm dia |
| 815 | 40 mm dia |
| 816 | 50 mm dia |
| 817 | 65 mm dia |
| 818 | 100 mm dia |
| 819 | 150 mm dia |
| 820 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required |
| 821 | 80 mm dia |
| 822 | 100 mm dia |
| 823 | 150 mm dia |
| 824 | 200 mm dia |
| 825 | Providing, installation, testing and commissioning of non-returnvalve of following sizes confirming to IS: 5312 complete with rubber gasket, Gl bolts, nuts, washers etc.as required : |
| 826 | 100 mm dia |
| 827 | 150 mm dia |
| 828 | 200 mm dia |
| 829 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. |
| 830 | 100 mm dia |
| 831 | 150 mm dia |
| 832 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63mm dia male and female couplings duly bound with GI wire, rivetsete. conforming to IS 636 (type-A) as required Stainless Steel (Grade 304) |
| 833 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic. (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket 30m |
| 834 | Supplying and fixing of fir brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: 4 way - 150 mm dia M.S. Pipe |
| 835 | Providing, fixing, testing & commissioning of 15mm dia quartzoidbulb type sprinklers of rating 68 degree centigrade with requiredaccessories. Pendent Sprinkler |
| 836 | Providing & fixing of pressure switch in M.S. pipe line includingconnection ete. as required. |
| 837 | Providing & fixing flow switch in following sizes M.S. pipe including ‘connection etc as required. |
| 838 | 100 mm dia |
| 839 | 150 mm dia |
| 840 | CO2 type fire existinguisher capacity : 4.5 k.g. |
| 841 | Water type fire extinguisher capacity 9 ltr. |
| 842 | FIRE ALARM SYSTEM |
| 843 | INTERNAL FIRE ALARM SYSTEM |
| 844 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. |
| 845 | Ten Loop Panel. |
| 846 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 847 | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. |
| 848 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 849 | Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. |
| 850 | Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required. |
| 851 | Supplying, installation, testing & commissioning of fault isolator complete with base as required. |
| 852 | Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. |
| 853 | Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. |
| 854 | Supplying, installation, testing & commissioning of addressable fire control module complete as required. |
| 855 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. |
| 856 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheathcomplete as required. |
| 857 | PUBLIC ADDRESS (PA) SYSTEM |
| 858 | Supplying, installation, testing & commissioning of 6 zone,voice alarm controller with USB, MP3 player (including 6 zonebutton paging station) with seamless integration facility withmain fire alarm panel for voice evacuation complete asrequired. |
| 859 | Supplying, installation, testing & commissioning of 1.5/3/6Wmetal box ceiling/wall speakers complete as required |
| 860 | Supplying, installation, testing & commissioning of digitalaudio amplifier 75 Watt, 25V rms operating at 240 Volt ACSupply complete as required. |
| 861 | Supplying, installation, testing & commissioning of exit pointdirectional sound speaker with voice and integral audioamplifier with selectable sound pulse patterns complete asrequired. |
| 862 | Supplying, installation, testing & commissioning of voice command keypad 6 zone with microphone assembly complete as required |
| 863 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed Pvc conduit of following pairs, cores and size including connections and interconnections etc. as required. |
| 864 | speaker cable Three pair, 2-core, 1.5 sqmm |
| 865 | speaker cable Four pair, 2-core, 1.5 sqmm |
| 866 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 867 | 20mm dia PVC conduit |
| 868 | 25mm dia PVC conduit |
| 869 | 32mm dia PVC conduit |
| 870 | RAIN WATER HARVESTING |
| 871 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge. |
| 872 | In all kind of soil upto 3.0m to 4.5m. depth |
| 873 | In all kind of soil upto 4.5 m to 6.0m. depth |
| 874 | Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. |
| 875 | Class M-150 brick work in 1:4 cement coarse sand mortar in foundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. |
| 876 | Suspended floors, roofs, landings, balconies and access platform. |
| 877 | Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 878 | 12mm cement plaster on rough side of single or half brick wall mix |
| 879 | 1:3 (1 cement : 3 Coarse sand) |
| 880 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: |
| 881 | With 20x20mm square bar |
| 882 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 883 | M.D. -10- Circular shape 500mm internal diameter |
| 884 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. |
| 885 | Drilling of 300mm dia bore hole manually. |
| 886 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
| 887 | 150 mm nominal size dia |
| 888 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 889 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 890 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge. |
| 891 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 892 | Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. |
| 893 | Suspended floors, roofs, landings, balconies and access platform. |
| 894 | Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 895 | 12mm cement plaster on rough side of single or half brick wall mix |
| 896 | 1:3 (1 cement : 3 Coarse sand) |
| 897 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: |
| 898 | With 20x20mm square bar |
| 899 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 900 | M.D. -10- Circular shape 500mm internal diameter |
| 901 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. |
| 902 | up to 1.50 m depth |
| 903 | Pipes 80 mm to 300 mm diameter |
| 904 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. |
| 905 | 150 mm. dia. RCC Pipes |
| 906 | 250 mm. dia. RCC Pipes |
| 907 | 600 mm. dia. RCC Pipes |
| 908 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design |
| 909 | 150 mm. dia. |
| 910 | 250 mm. dia. |
| 911 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line |
| 912 | Extra for depth for manholes: Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 |
| 913 | COST OF RAIN WATER HARVESTING |
| 914 | SUB HEAD - I - (SEWERAGE AND DRAINAGE) |
| 915 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm. |
| 916 | Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) |
| 917 | Depth not exceeding 1.5 meter |
| 918 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design |
| 919 | 150 mm. dia. RCC Pipes |
| 920 | 250 mm. dia. RCC Pipes |
| 921 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. |
| 922 | 150 mm. dia. RCC Pipes |
| 923 | 250 mm. dia. RCC Pipes |
| 924 | Providing and fixing square-mouth S.W. gully trap SP-1 complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design |
| 925 | 150 x 100 mm size P type |
| 926 | With common burnt clay FPS (non modular) bricks of class designation 75 |
| 927 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: |
| 928 | 100 mm diameter |
| 929 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. |
| 930 | Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). |
| 931 | With common burnt clay FPS (non modular) bricks of class designation 7.5 |
| 932 | Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :- |
| 933 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 934 | Extra for depth for manholes: |
| 935 | Size 90x80cm |
| 936 | With common burnt clay FPS (non modular) bricks of class designation 7.5 |
| 937 | Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 938 | SUB HEAD - II - EXTERNAL WATER SUPPLY |
| 939 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :- |
| 940 | All kinds of soil |
| 941 | Pipes, cables etc, not exceeding 80 mm dia. |
| 942 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. |
| 943 | 25 mm dia nominal bore |
| 944 | 32 mm dia nominal bore |
| 945 | 40 mm dia nominal bore |
| 946 | 50 mm dia nominal bore |
| 947 | 80 mm dia nominal bore |
| 948 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :- |
| 949 | 25 mm dia nominal bore |
| 950 | 32 mm dia nominal bore |
| 951 | 40 mm dia nominal bore |
| 952 | 50 mm dia nominal bore |
| 953 | 80 mm dia nominal bore |
| 954 | Providing and filling sand of grading zone V or coarser grade alround the G.I. pipes in external work. |
| 955 | 25 mm dia nominal bore |
| 956 | 32 mm dia nominal bore |
| 957 | 40 mm dia nominal bore |
| 958 | 50 mm dia nominal bore |
| 959 | 80 mm dia nominal bore |
| 960 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. |
| 961 | 25 mm dia nominal bore |
| 962 | 32 mm dia nominal bore |
| 963 | 40 mm dia nominal bore |
| 964 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required:- |
| 965 | 50 mm dia |
| 966 | 80 mm dia |
| 967 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 968 | 25 to 40 mm nominal bore |
| 969 | 50 to 80 mm nominal bore |
| 970 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design:- |
| 971 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 972 | Constructing masonry Chamber 60 x 60 x 75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 fine sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and180 mm deep (inside) with chain lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. With F.P.S. bricks |
| 973 | SEPTIC TANK & SOAK PIT |
| 974 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge. |
| 975 | In all kind of soil upto 1.5m depth |
| 976 | In all kind of soil upto 1.5m to 3.0m. depth |
| 977 | Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size) |
| 978 | Suspended floors, roofs, landings, balconies and access platform. |
| 979 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 980 | 12mm cement plaster on rough side of mix 1:3 (1 cement : 3 coarse sand) |
| 981 | Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. |
| 982 | Providing and fixing C.I. tee at the inlet and outlet of septic tank. |
| 983 | Providing & fixing 75mm dia vent pipes. |
| 984 | Providing & fixing of 75mm dia cast iron terminal guard. |
| 985 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 986 | M.D. -10- Circular shape 500mm internal diameter |
| 987 | M.D. -2.5- Circular shape 450mm internal diameter |
| 988 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks |
| 989 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 990 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 991 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class 150 in foundations and plinth in : cement mortar 1:4 (1 cement : 4 coarse sand) |
| 992 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 993 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 994 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-ironframe or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. |
| 995 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 996 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : |
| 997 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 998 | Columns,Pillars, Piers, Abutments, Posts and Struts. |
| 999 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 1000 | BOQ Road |
| 1001 | Providing and laying in position ready mixed or site batched design mix cementconcrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete.Concrete of M10 grade with minimum cement content of 220 kg /cum |
| 1002 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineerin- charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Cement concrete manufactured in automatic batching plant (RMC plant) including transportation to site in transit mixer |
| 1003 | Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade 'A' sealing compound. |
| 1004 | Providing and laying 200 Micron Dust proof waterproof Plastic Polythene Sheet. Please Enable Macros to View BoQ information |
| 1005 | Providing and laying 200 Micron Dust proof waterproof Plastic Polythene Sheet. Please Enable Macros to View BoQ information |