Name of Work:- RMO Various E&M Services at 72 Nos. Delhi Govt. Officers Flat GK-1, New Delhi. (SH:-SITC of automation and management system with microprocessor based control panel ,online monitoring and wireless connectivity with SCADA software at GK-1. | Sl. No. | Item Description | |
| 1 | Supplying, installation, testing & Commissioning of PUMP House Automation Electrical Panel, wall mounted indoor cubical Panel duly powder coated having suitable size for switchgear and accessories. The panel has to be fabricated from 1.6 mm thick CRCA sheet duly compartmentalized suitable for 415 volt 50Hz A.C supply of suitable size with control wiring in channel, MCB, Relay card channel, Terminal Block, Panel Control Wiring & Panel Stand i/c supplying and fixing of following accessories in panel complete as regd. 1.1) Cooling fan 4\\" - 1 Nos.1.2) SPMCB 6-32 Amp. - 2 Nos.1.3) 32 Amp TPN - 1 Nos.1.4) Relay card 8 Channel - 3 Nos.1.5) Push Button Flush Head - 12 Nos.1.6) Contact Blocks - 30 Nos.1.7) Push Button & Selector Actuators © 22.5 mm - 3 Nos.1.8) SMPS 12 VDC 6 Amp. - 2 Nos.1.9) SMPS 24 VDC 4.5 Amp. - 1 Nos.1.10) Indicator Gen Next LED 8531 22.5 mm - 15 Nos.1.11) Panel Light. - 1 Nos.1.12) \\"Modular AC Box With 20A SP MCB, Plastic Enclosure8 Unbreakable Heavy Duty With ISI Plug Top - 1 No. | | 2 | 1.13) MMU (Master Microprocessor Unit) With Smart Graphical Display Size 7\\" Inbuilt Software Application with wireless connectivity for all wireless device communication & cloud communication with wireless connectivity, Current transformer to be installed in pump house with following accessories listed below: Micro Processor Unit shall have control, protection & live data devices up to 6 Pumps 10 Sensor Micro Processor Fast Fourier transformation to eliminate harmonics &, Surges True RMS measurements & simultaneous sampling of Volts, Amps 2 layer protection & each 1/0 controller protected with a single form factor for multiple technologies high performance & accuracy with real time clock wireless connectivity compatible,data backup, various functions high Speed mode with instant switches from one input to the other & can be controlled in slot for memory with conncoted to external devices like android/os/windows platform & Pe through software key - CGPS plug - in software. Software key should comprised of UDP/ FTP/HTTP open standard Internal Expansion Wireless CPUR: with an core ARM7 32- bit foating point (72 MIZ max) microprocessor, with integrated IDE & GPRS connection with Uptime - Minimum 95%, Download Speed up to -4 Mbps Transter unlimited of all measured parameters/ quantity/ Auto Scrolling Password protected user programmable Parameters Fault Indication at display Access Point etc. - 1 No. | | 3 | Supplying installation testing & commissioning of Ultrasonic Sensor status of water tank output analog approx. liquid Quantity in tank, made of ABS housing, detection range not less than 2 meters, output analog approx, liquid quantity in Tank, etc. complete as required. | | 4 | Supplying, installation, testing & commissioning of microprocessor, suitable with control & wireless connectivity device transmitter and receiver (To be installed nearby sensor & line pressure transmitters for wireless data Range upto 1000 meters i/c sending data from upward to downward) for sending status of water tank to Master Microprocessor unit of on real time basis, for sending/receiving data from SCADA. Made of ABS Housing, Control :- Relay Based output & Display at 50 Level Water in tank indicator with suitable control panel operated at SPMCB 6 AMP. 230V single phase 50 Hz AC supply etc. complete as required. | | 5 | Supplying, installation, testing and commissioning of One CPU One LED 55\\" Display with Complete SCADA (Supervisory Control & Data Acquisition Software System) With wireless connectivity for AUTOMATIZATION of Pump house , water tank level for on line Monitoring pump house , Over Head Tanks & Under Ground Tanks with following specification. Server application for monitoring and controlling of system Data receive and sent through central application, event log store in server and can be checked, different level Message to different installation uit and location Software can be breakup in to different level for checking whole pump house and Tank Levels according to the client needs. Data Recipient should be added or delete manually according to the need as per the office requirement .Online Monitoring application should be within System for tracking. Data storage should be at central server for proper backup and support. Gateway server will manage all the incoming and outgoing Data. Fault or any breakdown reported immediately to concerned person through mobile messaging (persons can be 2 number). Each operations log stored in server & can be checked later on. Software can be breakup in to different level for checking whole pump house according to the client needs. Report can be checked according to the predefined level. Pump House data of different units can be stored in the software and Data will be done according to the employees in the unit. On network failure message should resend the data again. Internet tracking of all the operation in pump house through Web Login . Please Enable Macros to View BoQ information |
|