Indian Tenders

Tender Notice

TDR 55331093
Tendering Authority Indian Institute Of Technology
Tender No IIT/IW/EM/NIT/05/2026-27
Tender ID 2026_IITKG_907264_1
Tender Brief Tender For Estimate For Electrical Work (Phase-Ii) In The Left Bay Of Old Smst Basement Complex Ee Dept. Opposite To Kalidas Auditorium And Others Of New Academic Complex And Others At Iit Kharagpur.
City Kharagpur
State West Bengal
Document Fees Refer document
EMD INR 17974.0 /-
Tender Value INR 8.98 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Estimate For Electrical Work (Phase-Ii) In The Left Bay Of Old Smst Basement Complex Ee Dept. Opposite To Kalidas Auditorium And Others Of New Academic Complex And Others At Iit Kharagpur.

Key Dates

Publish Date 04-05-2026
Last Date of Bid Submission 25-05-2026
Tender Opening Date 26-05-2026

Contact Information

Company Name Indian Institute Of Technology
Contact Person Sr. Executive Engineer (EW)
Address Office of the Sr. Executive Engineer (EW), Estate (EM) Works Section, Old Building IIT KGP

BOQ Items

Name of Work:- Estimate for Electrical Work (Phase-II) in the left bay of OLD SMST Basement Complex EE Dept. opposite to Kalidas Auditorium and others of New Academic Complex and others at IIT Kharagpur.
Sl. No. Item Description
1Wiring for light point / ceiling fan point /wall fan point including 6 amp 3 pin socket/call bell point / exhaust fan point with 1.5 sq mm FRLS /HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable size GI box and earthing the point with 1.5 sq mm,1.1 kV, FRLS/HFFR PVC insulated copper conductor single core cable etc as required.Preferred Make ( Wire,1.1 kV ):-Finolex/RR Kabel/Polycab/Havells/KEI/Equivalent approvedby Engineer-in ChargePreferred Make (Switch,Socket,Blank plate etc):-Crabtree Athena range/Hager Insysta/Legrand Myline range/MK (Wraparound Plus)/Equivalent approved by Engineer-in ChargePreferred Make ( MMS Pipe):-Prestoplast/Precision/AKG/ Anchor/Equivalent approved by Engineer-in Charge
2Upto 6 metres.( Group A )
3Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor , single core cable in surface / recessed medium class PVC conduit as required .Preferred Make ( Wire,1.1 kV):- Finolex/RR Kabel/Polycab/Havells/KEIPreferred Make ( MMS Pipe):- Presto plast/Precision/AKG/ Anchor/Equivalent approved by Engineer-in Charge
42 X 1.5 sq mm + 1 X 1.5 sq mm for earth wire
52 X 2.5 sq mm + 1 X 2.5 sq mm for earth wire
62 X 4 sq mm + 1 X 4 sq mm for earth wire
72 X 6 sq mm + 1 X 6 sq mm for earth wire
84 X 2.5 sq mm + 2 X 2.5 sq mm for earth wire
94 X 4 sq mm + 2 X 4 sq mm for earth wire
104 X 6 sq mm + 2 X 6 sq mm for earth wire
114 X 10 sq mm + 2 X 6 sq mm for earth wire
124 X 16 sq mm + 2 X 6 sq mm for earth wire
13Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required.Preferred Make (MMS Pipe):-Presto plast/Precision/AKG/Anchor/Equivalent approved by Engineer-in Charge
1420 mm
1525 mm
16Supplying and drawing following sizes of FRLS/ PVC insulated 1.1 kV grade copper conductorsingle core cable in the existing surface /recessed steel / PVC conduit as required.Preferred Make (Wire):- Finolex/RR Kabel/Polycab/Havells/KEI/Equivalent approved by Engineer-in Charge
172 X 1.5 sq mm +1 X 1.5 sq mm for E.C.C
182 X 2.5 sq mm +1 X 2.5 sq mm for E.C.C
192 X 4 sq mm +1 X 4.0 sq mm for E.C.C
20Supplying and fixing following sizes / modules ,GI box along with modular base & cover plate for modular switches in recess etc as required.Preferred Make:- Crabtree Athena range/Hager Insysta/Legrand Myline range/MK (Wraparound Plus)/Equivalent approved by Engineer-in Charge.
211 or 2 Module (75 mm X 75 mm )
223 Module (100 mm X 75 mm )
234 Module (125 mm X 75 mm )
246 Module (200 mm X 77 mm )
2512 Module (200 mm X 150 mm )
26Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.Preferred Make:- Crabtree Athena range/Hager Insysta/Legrand Myline range/MK (Wraparound Plus)/Equivalent approved by Engineer-in Charge.
275 /6 Amps Switch
2815 /16 Amps Switch
293 pin 5 /6 Amps Socket Outlet
306 pin 15 / 16 Amps Socket Outlet
31Supplying and fixing Two Module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.Preferred Make:-Crabtree Athena range/Hager Insysta/Legrand Myline range/MK (Wraparound Plus)/Equivalent approved by Engineer-in Charge
32Supplying & Fixing suitable size GI box with modular plate and cover in front on surface or in recess,including providing and fixing 25 Amps modular socket outlet and 25 Amps modular SP MCB, \\"C\\" curve including connections,painting etc.as required.Preferred Make:-Crabtree Athena range/Hager Insysta/Legrand Myline range/MK (Wraparound Plus)/Equivalent approved by Engineer-in Charge
33Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required Preferred Make:- Crabtree/Hager Insysta/Legrand Myline range/MK/Equivalent approved by Engineer-in Charge.
34Installation , testing and commissioning of pre- wired, fluorescent fitting /compact fluorescent fitting/LED fittings of all types complete with all accessories and tube etc. directly on false ceiling / wall including connection with 3 X1.5 sq mm FRLS PVC insulated copper conductor single core cable and earthing etc as required.
35Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on Wall Surface as required incl. S+F of 1 X 10 SWG rust free GI wire for E.C.C making holes and manding good the damages to original finish incl painting.( Cable Dept supply)
36Upto 35 sq mm (rust free clamped with 1 mm thick rust free saddle)
37Above 35 sq mm and upto 95 sq mm (rust free clamped with 25 X 3 mm rust free MS flat clamp)
38Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on Cable Tray along with S+F of 10 SWG GI wire as earth wire as required.
39Upto 35 sq. mm (clamped with 1mm thick saddle @ 3 sets per metre.)
40Above 35 sq. mm and upto 95 sq. mm (clamped with 25 X 3mm MS flat clamp @ 3 sets per metre.)
41Supplying and making End Termination with brass compression gland and lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 kV grade as required.Preferred Make:-ARUN/Dowells/3M /Equivalent approved by Engineer-in Charge
422 X 10 sq mm (19 mm )
432 X 16 sq mm ( 22 mm )
444 X 10 sq mm (25 mm )
454 X 16 sq mm (28 mm )
463.5 X 25 sq mm (28 mm )
473.5 X 35 sq mm (32 mm )
48Supplying and Fixing DP/4P Sheet Steel Enclosure on surface/recess complete with connection,testing and commissioning etc.as required with out MCB/MCCB Preferred Make:- Legrand /Hager/L&T/Siemens/Schneider/ABB/Equivalent approved by Engineer-in Charge
49Two Pole Enclosure for MCB
50Four Pole Enclosure for MCB
51Supplying and fixing following way, Single Pole and Neutral, IP- 43, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) Preferred Make:-Legrand/Hager/L&T/ABB/Equivalent approved by Engineer-in Charge
528 Way , Double door
5312 Way Double door
54Supplying and fixing of following ways surface/ recess mounting, Horizontal type, IP-43,415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 Amps, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. Preferred Make:-Legrand/Hager/L&T/Siemens/ABB/Equivalent approved by Engineer-in Charge
558 Way (4 + 24), Double door
56Supplying and fixing of following ways surface/ recess mounting, Vertical Type,IP-43, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 Amps, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TP DB is normally used where 3 phase outlets are required.) Preferred Make:-Legrand/L&T/Hager/Siemens/Equivalent approved by Engineer-in Charge
574 Way (4 + 12), Double door
58Supplying and fixing 5 Amps to 32 Amps rating, 240/415 V,10 kA,“C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Preferred Make:- Legrand/Hager/L&T/Siemens/Schneider/ABB/Equivalent approved by Engineer-in Charge
59Single Pole
60Double Pole
61Triple Pole
62Triple Pole and Neutral
63Supplying and fixing 40 Amps to 63Amps rating, 240/415 V,10 kA,“C”curve, MiniatureCircuit breaker suitable for inductive load of following poles in the existing MCB DB or inenclosure complete with connections, testing and commissioning etc. as required. Preferred Make:-Legrand /Hager/L&T/Siemens/Schneider/ABBEquivalent approved by Engineer-in Charge
64Single Pole
65Double Pole
66Triple Pole
67Four Pole
68Supplying and fixing 100 Amps rating, 240/415 V, 10 kA, “C” curve, Miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB or in enclosure complete with connections, testing and commissioning etc. as required. Preferred Make:-Legrand /Hager/L&T/Siemens/Schneider/ABB/Equivalentapproved by Engineer-in Charge
69Four Pole
70Supplying and fixing of Molded Case Circuit Breaker,415 Volt, of Breaking capacity 25 kA/35kAwith Icu = Ics (for 1 sec),adjustable overload setting (Thermal Magnetic) with two sets copper spreader terminals suitable for inductive load of following poles in the existing MCB/MCCB DB/SMDB or in enclosure complete with connections, testing and commissioning etc. as required.Preferred Make:- Legrand /Hager/L&T/Siemens/Schneider/ABBEquivalent approved by Engineer-in Charge
71125 Amps, Four Pole Please Enable Macros to View BoQ information

Other Detail

Information Source https://eprocure.gov.in/eprocure/app
Download FileName File Description File Size
Download 39a47622-6857-48a3-8f74-3c95dd7343fd.html Tender Documents 0 KB
Download BOQ_953603.xls Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.