| 1 | Wiring for light point fan point exhaust fan point call bell point with 1.5 sq.mm | FRLS PVC insulated copper conductor single core cable in surface recessed medium class PVC conduit |
| 2 | Earth Wire | 2 X 2.5 SQ.MM + 1 X 2.5 SQ.MM Earth Wire |
| 3 | Earth Wire | 2 X 4.0 SQ.MM + 1 X 4.0 SQ.MM Earth Wire |
| 4 | Earth Wire | 4 X 6.0 SQ.MM + 2 X 6.0 SQ.MM Earth Wire |
| 5 | Earth Wire | 4 X 16.0 SQ.MM + 2 X 6.0 SQ.MM Earth Wire |
| 6 | Supplying and drawing following sizes of PVC conduit as required 1.5MM | Supplying and drawing following sizes of PVC conduit as required 1.5MM |
| 7 | modular plate | 5x6 amps switch |
| 8 | modular plate | 3 pin 5x6 amp socket outlet |
| 9 | modular plate | 15x16 A switch |
| 10 | modular plate | 6 pin 15x16 A socket outlet |
| 11 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate | switch box including connections but excluding modular plate etc. as required. |
| 12 | Supplying and fixing modular blanking plate on the existing modular plate | and switch box excluding modular plate as required |
| 13 | Supplying and fixing following size | Supplying and fixing following size |
| 14 | 3 Module 100mmX75mm | Supplying and fixing following size |
| 15 | 4 Module 125mmX75mm | Supplying and fixing following size |
| 16 | 6 Module 200mmX75mm | Supplying and fixing following size |
| 17 | 8 Module 125mmX125mm | Supplying and fixing following size |
| 18 | 12 Module 200mmX150mm | Supplying and fixing following size |
| 19 | Supplying and fixing suitable size GI box | with modular plate and cover in front on surface or in recess |
| 20 | 15x16 amps | Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface |
| 21 | a exhaust fan of all sizes. | Extra for fixing the louvers shutters complete with frame for |
| 22 | modular plate and cover in front on surface or in recess | Supplying and fixing suitable size GI box with |
| 23 | providing and fixing 25 A | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including |
| 24 | MCB distribution board | Supplying and fixing following way horizontal type three pole and neutral sheet steel |
| 25 | Single Pole 6 to 32 Amp | Supplying and fixing following rating 240x415 V 10 kA C curve |
| 26 | Single pole and neutral 6 to 32 Amp | Supplying and fixing following rating 240x415 V 10 kA C curve |
| 27 | Single pole and neutral 63 Amp | Supplying and fixing following rating 240x415 V 10 kA C curve |
| 28 | Triple pole and neutral 32 Amp. | Supplying and fixing following rating 240x415 V 10 kA C curve |
| 29 | 63 A TPN MCB 10 Ka C Curve | Supplying and fixing following rating Four pole 415 V 10 Ka M.C.B in the existing MCB DB complete with connections |
| 30 | MCB DB complete etc as required | Supplying and fixing single pole blanking plate in the existing |
| 31 | 32 A 415 V C curve TP MCB | Supplying and fixing TP sheet steel enclosure on surface recess along with |
| 32 | 600 mm X 600 mm X 6 mm thick watering pipe of 2.7 Meter long etc. | Earthing with G.I. earth plate with charcoal coke and salt as required. |
| 33 | Providing and fixing 25 mm X 5 mm GI | strip on surface or in recess for connections etc. as required. |
| 34 | Providing and fixing 6 SWG dia GI | wire on surface or in recess for loop earthing as required. |
| 35 | LED Batten light 40 watt | LED Batten light 40 watt |
| 36 | Ceiling Fan 3 Star Rated with Voltage Range 90 V to 300 V 1200 MM | Supply installation testing and commissioning of |
| 37 | 300mmx12 inch sweep exhust fan | Supplying and fixing of following sizes |
| 38 | 50 W Flood Light 50 watt | Supply installation testing and commissioning of |
| 39 | SITC of Building Distribution Panel Indoor | free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works made out of CRCA sheet. |
| 40 | 160 A 36KA FPMCCB | 160 A 36KA FPMCCB |
| 41 | Aluminium Bus Bar 200 Amp set of 4 strips 18 inch | Aluminium Bus Bar 200 Amp set of 4 strips 18 inch |
| 42 | Digital Metering devices | comprising of Voltmeter Ammeter Selector Switch Indicating Lamp CT Set etc |
| 43 | 63 A TPN MCB 10 Ka C Curve | 63 A TPN MCB 10 Ka C Curve |
| 44 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories |
| 45 | Supplying and Laying of one number PVC insulated and PVC sheathed | Supplying and Laying of one number PVC insulated and PVC sheathed |
| 46 | Supply and Making end Termination with Brass Compression Gland and Aluminium Lugs | for the Following Sizes of PVC insulated and PVC Sheathed |
| 47 | 2.5 KVA Sine Wave Inverter Input 1 Phase 3 wire and output 1 phase 3 wire with 2 Nos of 12 V 200 aH Battery | Supply installation testing and commissioning of |
| 48 | Hot Dipped Galvanised Iron cable tray 100 mm width X 50 mm depth X 1.6 mm thickness | Supplying and installing following size of perforated |