| 1 | Description of work |
| 2 | Construction of embankment with approved material obtained from borrow pits with all lifts upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-1 and 300.2 with lead up to 1000m as per technical specification clause 301.5 |
| 3 | Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5m and lead upto 50m as per Technical Specification Clause 302.3 |
| 4 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 I. P.C.C grade M 10 (i) Nominal mix 1:4:8 |
| 5 | Brick masonry work in cement mortar in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 600, 1202 & 1203 II. Brick masonry in 1:4 cement mortar |
| 6 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802,804,805,806,807,1202 and 1204 |
| 7 | Plastering with cement mortar (1:4), 12 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204 |
| 8 | Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density as per MORD specification 401 |
| 9 | WBM Grading 3 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. |
| 10 | Providing,Laying,Spreading and compacting graded stone aggregates to Wet Mix Macadem specification including premixing the material with water at OMC in mechanical Mixer (Pug Mill) carriage of mixed Material by tipper to site,laying in uniform layers in sub base/base course on a well prepared sub base and compacting with smooth wheel roller 80-100 KN weight to achieve the desired density including lighting,barricating and maintenance of diversion,etc,as per tables 400.11 & 400.12 and Technical Specification Clause 406.. |
| 11 | Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 to 1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 Mord |
| 12 | Providing and applying tack coat with bitumen (RS-1) using bitumen distributor at the rate of 0.30 to 0.40 kg per sqm on the prepared granuler surfaces treated primer and cleaned with Hydraulic broom as per Technical Specification Clause 503. MORD |
| 13 | Providing and Laying dense graded bituminous Macadem with higher capacity hot mix plant using crushed aggregates of specific grading premixed with bituminous binder transported to site lead over a previously prepared surface with paver finisher to required grade level ang alignment and roller as per clauses 501.6 and 501.7 to achieve the desired compaction. |
| 14 | Providing and Laying dense graded bituminous Concrete with higher capacity hot mix plant using crushed aggregates of specific grading premixed with bituminous binder @ 5.40% of Mix and filler transporting the Hot Mix to work site laying with a hydrostatic paver finisher with sencer controll to the required grade level and alignment rolling with smooth wheeld vibratory and tendem roller to acheive the desired construction as per morth specification clause No.507 complete in all respect . |
| 15 | Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35-2015 The finished surface to be level, uniform and free from streaks and holes. |
| 16 | Providing and Laying of Interlocking Concrete Block Pavements having thickness 80 mm as per drawings and Technical Specification Clause 1504. |
| 17 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 |
| 18 | Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 |
| 19 | Supply and fixing 4.00X2.50 Ft.Size Inauguration Stone of Granite.Sanction by SE RED Knp. |
| 20 | Supply and fixing 4.00X3.00 Ft.Size Road Sign board .Sanction by SE RED Knp. Please Enable Macros to View BoQ information |