| 1 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume). |
| 2 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 3 | Providing designation 75A brick work in C.M (1: 4) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 4 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size). |
| 5 | Providing cement flush pointing (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 6 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 7 | Stainless steel wire guage (Grade-304) aperture 1.4 mm and 0.50 mm dia wire |
| 8 | Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm . |
| 9 | S.I.T.C of following rating LED Flood lighting luminaries with pressure die cast housing and toughened glass cover,IP 66 protection, LUMINIOUS EFFICARY 110LM/W, with lens in existing pole/pipe for supply voltage100-270v AC, 50Hz Luminaries shall confirm to IS;10322 part- 5/section-5 and shall be complete with all necessary accessories as required. 90/100W LED Flood light |
| 10 | Supply of flat copper submersible cable of following core and size 3 Core 4 Sq.mm (service line) |
| 11 | Wiring for light point/fan point /exhaust fan point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular switch ,modular plate suitable GI box etc as required. Group A |
| 12 | Wiring for circuit /submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor for single core cable in surface/recessed PVC conduit as required. 2x2.5 sq.mm |
| 13 | Wiring for circuit /submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor for single core cable in surface/recessed PVC conduit as required. 2x4.0 sq.mm |
| 14 | Supplying and fixing suitable GI box with modular plate and cover in front on surface or in rercess ,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch ,connection etc as required |
| 15 | Supplying and fixing following way single pole and neutral ,sheetb steel ,MCB distribution board ,240 volts on surface /recess complete with tinned copper bus bar ,neutal bus bar etc as required.(But without MCB/rccb/Isolator) 6 way ,single door |
| 16 | Supplying and fixing 6 amp to 32 amp rating ,240 volt 10 Ka C curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections ,testing and commissioning etc as required. 6/32 amp ,single pole |
| 17 | Supplying and fixing 6 amp to 32 amp rating ,240 volt 10 Ka C curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections ,testing and commissioning etc as required. 6/32 amp ,SPN |
| 18 | Supply and fixing of 12''(300mm)metal exhaust fan complet with connection as required. |
| 19 | Sand lead 30 Km |
| 20 | brick |
| 21 | Add GST @ 18% |
| 22 | Add LWF @1 % Please Enable Macros to View BoQ information |