Indian Tenders

Tender Notice

TDR 55322566
Tendering Authority Military Engineer Services
Tender No 8924/OKHA/E8
Tender ID 2026_MES_763209_1
Tender Brief Tender For Repair/ Replacement/ Maintenance Of Panels And Enclosures Etc For Various E/M Miscellaneous Items, Certain Cooling And Refrigeration Appliances And Allied Works At Various Locations Of Naval Base Okha Under Ge Navy Porbandar
City Porbandar
State Gujarat
Document Fees INR 500 /-
EMD INR 42200.0 /-
Tender Value Refer document
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Repair/ Replacement/ Maintenance Of Panels And Enclosures Etc For Various E/M Miscellaneous Items, Certain Cooling And Refrigeration Appliances And Allied Works At Various Locations Of Naval Base Okha Under Ge Navy Porbandar

Key Dates

Publish Date 02-05-2026
Last Date of Bid Submission 23-05-2026
Tender Opening Date 25-05-2026

Contact Information

Company Name Military Engineer Services
Contact Person GE Navy Porbandar
Address GE Navy Porbandar, Tija Mile Porbandar

BOQ Items

Name of Work:- REPAIR/ REPLACEMENT/ MAINTENANCE OF PANELS AND ENCLOSURES ETC FOR VARIOUS E/M MISCELLANEOUS ITEMS, CERTAIN COOLING AND REFRIGERATION APPLIANCES AND ALLIED WORKS AT VARIOUS LOCATIONS OF NAVAL BASE OKHA UNDER GE NAVY PORBANDAR
Sl. No. Item Description
1S&F in replacement of aluminium bus bar PVC insulated in RED,yellow,Blue & Black colours of rating 400 Amps complete all as specified and as directed.
2S&F in replacement of aluminium bus bar PVC insulated in RED,yellow,Blue & Black colours of rating 600 Amps complete all as specified and as directed.
3S&F in replacement of insulator of appropriate size with existing one complete all as directed by Engr-in-Charge
4M&L taking down shutdown the LT panel and disconnecting the power cable for necessary repair and servcing of ACB 630Amps including necessary spare parts and testing complete including all as specified and directed.
5S&F in replacement of Junction feeder Panel enclousure suitable for single MCCB for CRCA sheet, CPRI approved IP-54 duly painted with epoxy based powder coated paint, including base channel, of size 600x600x450 mm incl fixing of 630Amps MCCB 4 pole 50KA suitable for out door type double door locking arrangement comprising of its accessories, cable gland with hinged door, bus chamber with bolted double door etc dust & vermin proof construction attractive powder coated fixed/groutning on PCC foundation 45cm above ground level including all necessary excavation complete all as specified and directed.
6S&F in replacement of Junction feeder Panel enclousure suitable for single MCCB for CRCA sheet, CPRI approved IP-54 duly painted with epoxy based powder coated paint, including base channel, of size 600x600x450 mm incl fixing of 250Amps MCCB 4 pole 50KA suitable for out door type double door locking arrangement comprising of its accessories, cable gland with hinged door, bus chamber with bolted double door etc dust & vermin proof construction attractive powder coated fixed/groutning on PCC foundation 45cm above ground level including all necessary excavation complete all as specified and directed.
7Disconnecting & Taking out old U/S joints & Supplying, Fixing, Jointing & testing for provision of end termination joint Kits, heat shrinkable eppoxy tube with epoxy jointning materials suitable for XLPE ,LT Cable 1100 Volts grade indoor , for size 240sqmm to 400sqmm 3.5Core all as specified and directed by engr-in- Charge. (Make;- M.SEAL/DENSON/Raychem)
8S&F in replacement of digital Multifunctional meter as per matching to existing including all accessories and wiring complete all as specified and as directed. Make:- AE/L&T.
9S&F in replacement of power factor meter digital type for frequency range (45-65 Hz) as per matching to existing one including all accessories and wiring complete all as specified and as directed. Make:- AE/L&T.
10M&L for dismantling old LT APFC panel and supply, installation, testing & commissioning floor mounted compartmentewise factory made Indoor cubical LT APFC panel made of 2.0 mm thick CRCA sheet with aluminium bus bar suitable for 500 Amp, CPRI approved duly painted with epoxy based powder coated paint, including base channel, inter connection control wiring name plate for each switch gears, danger plate, earth bus bar as per IS 5039. comprising of compartments for 250 KVAR (50+50+25+25+25+25+25+10+10+5) in shape of round capacitors and its accessories, cable gland with hinged door, bus bar chamber with bolted door etc dust & vermin proof construction attractive powder coated complete all as specified and as directed. Note:- supply and fixing Switchgears/ Capacitors/Contactors/Relay connected accessories and other required accessories will be paid seperately.
11(a) MCCB 500Amps 3Pole 36KA fixed type DN3- 6300
12(b)Spreaders -1 No
13(c ) APFC Relay 11 Stages -1 No
14(d) DIGITAL MultiMeter inbuilt Selector Switches -1 No
15(e ) LED Red,Yelow, Blue Indicator Set -1 No
16(f) A/M Switch - 11 Nos
17(g) LED Indicating Lights - 11 Nos
18(h) Capcitor Banks MPP-H 10 KVAR Round Type - 03 Nos
19(i) Capcitor Banks MPP-H 25 KVAR Round Type 08Nos
20(j) Capacitor Duty Contactor MO 12.5 - 03Nos
21(k) Capacitor Duty Contactor MO C25 - 08 Nos
22(l) MCB 25A 3P, 10KA - 03 Nos
23(m) MCB 63A 3P, 10KA - 08 Nos
24Supply & Fixing in replacement of installation, testing and commissioning factory made, floor mounted outdoor type LT panel board suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz, AC supply system, CPRI approved manufactures having bus bar chamber with insulated Aluminium bus bar 400Amp rated, four wire system, colour coded for each phase of rating as per under for phase and neutral, insulated on epoxy type insulators. The panel shall be dust and vermin proof, IP-54 class protection and made 3.15 mm of outer body and inner body 2.00 mm thick CRCA MS sheet , powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm) including grouting of panel 30 cm above ground level by providing 60 cm long angle iron frame of size 40x40x5mm, welded on all the four corners, embedded in pcc 1:2:4 using 20 mm stone aggregate upto 30 cm complete all as specified and directed including the following accessories:- (Make :- CPRI Approved) (a) MCCB Thermal magnetic based 200Amps 4 pole , 35 KA, 415 Volt (Incomer) - 01 No(b) MCCB Thermal magnetic based 63Amps 4 pole ,25 KA, 415 Volt (Ougoing) - 04 Nos(c) MCB TPN 40 Amps \\"C\\" Curve breaking capacity 10KA - 02Nos(d) Digital Ammeter with CT's and Selector switch-01 Set(e) Digital Voltmeter with selector switches - 01Nos(f) Digital Multifuntional Meter with selector switches - 01No(g) Indicating lamp LED Type-RYB-01 Set
25S&F in replacement of Junction box SMC KIOSK box water proof IP-54 of size 140x140x95 mm incl fixing of terminal connector 100A 4 pole suitable for in and out connection of 3 core 2.5sqmm cable fixed to termination box to ligt fittings complete. Make : HENSEL/SYNTEX
26Supply and Repair/Replacement of Laying in trenches or passing through pipe, 120 Sqmm 3.5 core LT XLPE cable with stranded aluminium conductor heavy duth for 1100 volts grade cross sectional area complete all as specified and as directed.
27Supply and Repair/Replacement for 250 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable type against over load and short circuit conditions incl neutral adjustment of capacity suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed. Make : Havells/ Legrand/L&T/C&S
28Supply and Repair/Replacement for 200 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable type against over load and short circuit conditions incl neutral adjustment of capacity suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed. Make : Havells/ Legrand/L&T/C&S
29Supply and Repair/Replacement for 63 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustabletypeagainst over load and short circuit conditions incl neutral adjustment of capacity suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed. Make : Havells/ Legrand/L&T/C&S
30M&L in Replacement earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to GI strips 25 x 4 mm by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both ways all as shown in electrical plate No. 3 of SSR Part-I all as specified and directed.
31M&L for Cement Concrete 1:4:8 (40mm Graded Stone Aggregate) as in Foundation of Panel, etc. including Formwork (as/if required), complete all as specified and as directed.
32Supply and Repair/Replacement of 300Watt flood light Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting. highmast/basket ball court/squach court/batmittan court light etc complete all as specified and directed including taking down the u/s flood light fittings.
33Supply and Repair/Replacement of Laying in trenches or passing through pipe,25 Sqmm 4 core LT XLPE cable with stranded aluminium conductor heavy duth for 1100 volts grade cross sectional area complete all as specified and as directed.
34Supply and lay Double Walled Corrugated (DWC) Pipes of dia 50mm having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables size 50 mm outer dia laid in trenches/ road/ drain or fixed along wall, poles or laid under floor all as spd and as directed by Engr-In-Charge.
35Supply and Repair/Replacement for Cable with copper conductor PVC round sheathed (flexible) 3 core 4 sqmm industrial cable complete all as specified and directed by Engineer-in-Charge.
36Supply and Repair/Replcement for weather proof flat twin core 6 sqmm multistrand Aluminium conductor cable with PVC conduit of dia 25mm with accessories complete all as specified and directed by Engineer-in-Charge.
37Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m deep and getting out hard/dense soil for taking out / laying of UG cable.LT of any size complete all as specified and as directed.
38Returning and filling in trenches incl spreading, levelling watering and raming in layer n.exc 25 cm complete all as specified and directed.
39Removing of excavated mtrls n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point.
40Material and labour for Detecting the gas leakage, rectifying the defects by vacumizing and charging fresh mafron gas and commissioning and testing the Water cooler of Capacity 40/80 Ltrs.
41Ditto all as per item No. 27 above but of Water cooler 120/315 Ltrs. Capacity.
42Ditto all as per item No. 27 above but of Refrigerator 165/180/230 Ltrs. Capacity.
43Ditto all as per item No. 27 above but of Refrigerator 260/280/310/350 Ltrs. Capacity.
44Ditto all as per item No. 27 above but of Deep Freezer of 260/280/310/350/500 Ltrs. Capacity. Please Enable Macros to View BoQ information
45Ditto all as per item No. 27 above but of Deep Freezer of 260/280/310/350/500 Ltrs. Capacity. Please Enable Macros to View BoQ information

Other Detail

Information Source https://defproc.gov.in/nicgep/app
Download FileName File Description File Size
Download 11670917-e6c3-4861-8112-49ef20b0e05f.html Tender Documents 0 KB
Download BOQ_854893.xls Tender Documents 0 KB
Download Gen_spec.pdf Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.