| 1 | M & L for servicing of LT panel including dismantling the old cable lugs of any size by cutting the cable including fixing of new lugs by pealing the cable, cutting and jointing the cables with the help of Cable Joint Kit of suitable size if required, servicing of MCCBs/MCBs/Bush Bar/ Checking/Replacing of Nut Bolts etc. cleaning of all joint make joint Carbon free and remove rusted part by chemicals and painting the panel with synthetic enamel paint two coat complete all as specified and directed by Engineer in Charge.Note: i) The items i.e. MCCBs/MCBs, Cable Joint Kit of suitable size shall be measured and paid seperately under various item.ii) The material and labour required for servicing of LT panel i.e consumables/nut bolts etc shall be deemed to be included in the item rate. |
| 2 | S&F in replacement LT volt meter (0-500) digital squire flush type of size 96x96 mm including necessary addition/ alternation of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder including taking out of unserviceable Volt meter complete as sepecified and directed by Engr-in-Charge. Make:AE/MECO/Schneider/L&T |
| 3 | S&F in replacement 1100 Volts grade LT Ammeter (0 - 500 A) digital squire flush & CT type with CT's including necessary addition/ alternation of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder taking out of unserviceable Ammeter complete as sepecified and directed by Engr-in-Charge. Make:AE/MECO/Schneider/L&T |
| 4 | Supply and fixing in replacement cast resin insulated type CT Ratio 200/5A with capable of withstanding momentary short circuit and symmetrical short circuit for 1 second including taking down old one all as specified and as directed |
| 5 | Supply and fixing as in replacement cast resin insulated type CT Ratio 100/5A with capable of withstanding momentary short circuit and symmetrical short circuit for 1 second including taking down old one all as specified and as directed |
| 6 | S&F in replacement Hot press moulded SMC junction box 240mm x 130mm x 95mm (inside dimension) fixed with left side hinges and cable terminals with bus bar and one number 6 Amp SP MCB fixed to pole with clamp nuts,bolts etc complete all as specified and directed by Engineer-in-charge.Make: Sintex / National or equivalent model of makes specified. |
| 7 | Supply and fixing in repair MCCB, AC 415 V, 50 HZ, fixed type, capacity 400 Amps, 3/4 Pole, 25/36 KA, suitable to be fixed in LT panel complete all as specified and directed Make: L&T/Legrand/ABB of capaqcity 200/250 amps 36 KA. Make: L&T/Legrand/ABB/Havells/C&S |
| 8 | All as per item No.07 above but of capaqcity 250 amps 18/25 KA . Make: L&T/Legrand/ABB/Havells/C&S |
| 9 | All as per item No.07 above but of capaqcity 200 amps 18/25 KA . Make: L&T/Legrand/ABB/Havells/C&S |
| 10 | All as per item No.07 above but of capaqcity 160 amps 16/25 KA . Make: L&T/Legrand/ABB/Havells/C&S |
| 11 | All as per item No.07 above but of capaqcity 125 amps 16 KA . Make: L&T/Legrand/ABB/Havells/C&S |
| 12 | All as per item No.07 above but of capaqcity 100 amps 16 KA . Make: L&T/Legrand/ABB/Havells/C&S |
| 13 | Supply only Multi Function meters in existing HT/LT Panel Board Digital type 96x96mm, Aux Supply 230Volts AC,Type: EM6436 Conzerv(Schneider Electric) or Equvallant AE/SECURE complete all as specified and directed by Engineer-in-Charge. |
| 14 | Material and labour for Fixing and testing of Vaccum intrupter o f 11KV VCB including taking down old unserviceable or burnt Vaccum intrupter Of feeder panel. all as per directed by Engr In Charge.Maker - Crompton greaves power or as per the sample of existing. |
| 15 | Supply and fixing in repair/replacement decorative heritage ornamental type poles including of Antique single arm vintage type bracket with 01 Nos of 12 Watt, 230 V AC LED light fittings with excellent/ glare free soft light output through its PMMA window ensuring maximum illumination aspect in surrounding for longer life complete all as specified and as directed. Make : Shakti/Luminous/Orient/Bajaj or equivalent as approved by GE |
| 16 | Supply and fixing in repair/replacement decorative heritage ornamental type poles including of of Antique double arm vintage type bracket with 02 Nos of 12 Watt, 230 V AC LED light fittings with excellent/ glare free soft light output through its PMMA window ensuring maximum illumination aspect in surrounding for longer life complete all as specified and as directed. Make : Shakti/Luminous/Orient/Bajaj or equivalent as approved by GE |
| 17 | Supply and fix in replacement Relay Nuemerical IDMTL+Inst O/C & E/F, Type N141 (Art.No.1MYN742838D) 30V DC,CTR 5A. Make: Asida/C&S/L&T/Eassun Reyrole/Schnieder/CG/ABB/ GEC/ EE/ Seimens |
| 18 | Material and labour for Fixing and testing of Current transformer resin cast ratio 100-50/5-5A. o f 11KV VCB including taking down old unserviceable or Current transformer resin Of feeder panel. all as per directed by Engr In Charge.Make - Crompton greaves power or as per the sample of existing. |
| 19 | M&L in repair for providing and fixing tri-colour LED lights strip of 18 mtr (Saffron, white and green ) around the pole , outdoor grade IP 65 Led strip with uniform illumination, complete with necessary fittings arrangement complete all as specified and as directed. |
| 20 | M&L for providing and fixing PCC block 30 cmx30cmx30 cm including PVC pipe for passing of 3core 1.5/2.5 sqmm cable complete all as specified and as directed |
| 21 | Material and labour in repair fixing and testing Potential Transformer, Resin cast dry type 11KV/ 110Volt /Rout3,100VA burden, Class 1 Accuracy, Trolly mounted.Make - Crompton greaves power or as per the sample of existing. |
| 22 | Supply and fixing as in replacement heavy duty easy to install, open type Bakellite Connector plate, 63 amps 4 bolt type (TPN) 1100 volts grade with necessary nuts bolts and washers of adequate size, length and mounting support complete all as specified and as directed |
| 23 | Supply and fixing as in replacement heavy duty easy to install, open type Bakellite Connector plate, 100 amps 4 bolt type (TPN) 1100 volts grade with necessary nuts bolts and washers of adequate size, length and mounting support complete all as specified and as directed |
| 24 | Supply and fixing as in replacement heavy duty easy to install, open type Bakellite Connector plate, 150 amps 4 bolt type (TPN) 1100 volts grade with necessary nuts bolts and washers of adequate size, length and mounting support complete all as specified and as directed |
| 25 | Supply and fixing as in replacement epoxy type insulator for support of bubar grade 1100 volt as per existing size at site complete all as specified and as directed |
| 26 | S& f in replacement of Switch air break gang operated triple pole mechanically operated mounted on insulator and steel frame out door type suitable for vertical installation single brake provided with locking arrangement, rocking tilting type consisting of MS channel ,HT post type insulator ,copper alloy high pressure assembly ,operating rod of GI pipe medium grade confirming to IS-1818 of 1972 ,suitable for 11000 volt ,400 Amps all as specified. |
| 27 | Supply and laying of Stone aggregate of size 40 mm /20 mm and laid in 4 pole structure/ DG set location / sub station area and two pole structure including cleaning bushes from grass root and making good surface before laying of stone aggregate complete all as directed by Engg-in-charge Please Enable Macros to View BoQ information |
| 28 | Supply and laying of Stone aggregate of size 40 mm /20 mm and laid in 4 pole structure/ DG set location / sub station area and two pole structure including cleaning bushes from grass root and making good surface before laying of stone aggregate complete all as directed by Engg-in-charge Please Enable Macros to View BoQ information |