Indian Tenders

Tender Notice

TDR 55321834
Tendering Authority Public Works Department
Tender No 02/EE(E)/NED/PWD/M-352/2026-27
Tender ID 2026_PWD_290708_1
Tender Brief Tender For repair maintenance Electrical & Mechanical Service In Dseu C Us, Ashok Vihar, Delhi. (Sh: Maintenance & Operation Of electrical installation & Fans, Street Light, Sub-Station, Dg Set, Ro Plants, Fire Fighting System, Acs, Pumps Etc.) (For
City Delhi
State Delhi
Document Fees Refer document
EMD INR 60035.0 /-
Tender Value INR 30.01 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for repair maintenance Electrical & Mechanical Service In Dseu C Us, Ashok Vihar, Delhi. (Sh: Maintenance & Operation Of electrical installation & Fans, Street Light, Sub-Station, Dg Set, Ro Plants, Fire Fighting System, Acs, Pumps Etc.) (For 2026-27)

Key Dates

Publish Date 02-05-2026
Last Date of Bid Submission 11-05-2026
Tender Opening Date 11-05-2026

Contact Information

Company Name Public Works Department
Contact Person EE(E)
Address Executive Engineer (E), North Electrical Division, PWD, Dr. BSA Hospital, Sector -6, Rohini, Delhi - 110085

BOQ Items

Name of Work:- RMO Electrical & Mechanical Service in DSEU C us, Ashok Vihar, Delhi. (SH: Maintenance & Operation of EI & Fans, Street light, Sub-Station, DG set, RO plants, Fire Fighting System, ACs, Pumps etc.) (For 2026-27)
Sl. No. Item Description
1Providing skilled and unskilled staff for operation and routine maintenance of electrical and mechanical installations at Arya Bhatt Polytechnic as per the inventory and as per direction of Engineer-in-charge & as per the terms and conditions for the following works:-a) Operation and routine maintenance of Electrical Installations (Internal & External), Operation of RO plant, Operation of Sub-station and DG Set. Operation of water supply pump set and fire fighting etc. i) Wireman cum Operator - 04 Nos. (One in each shift (6 AM to 2 PM, 2 PM to 10 PM & 10 PM to 6 AM) and 1 No. in General shift (9 AM to 5 PM))ii) Khallasi - 02 Nos. (9 AM to 5 PM & 10 PM to 6 AM)
2Comprehensive, running maintenance & day to day servicing of following capacity Window / Split AC and water cooler installed under Sub-Division-I i/c replacement all defective i.e. blower motor, compressor, Gas Charging, PCB, remote, Plug Top, Starting Capacitor, Running Capacitor, Starting Relay, Thermostat, Propeller Fan, Over load Relay i/c condenser unit, evaporative unit charging of refrigerant gas in case of leakage i/c refrigerant gas pipe with insulation, lead wire, plug Top, etc complete as per terms and conditions attached:-a) Window type AC/ Split type AC of 1.5TR/2.0 TR capacity. (43 Nos. for 8 Months- 344 Jobs)
3b) Water coolers of capacities 100/150 ltr (10 Nos. for 12 Months-120 Jobs)
4Supplying & fixing of following electrical accessories suitable for existing different type fitting/switch box i/c testing etc. as required. (Labour already included in Item No. 1)5/6 A switch (Modular type)
515/16 A switch (Modular type)
63 pin 5/6 A socket outlet (Modular type)
76 pin 15/16 A socket outlet (Modular type)
8Stepped type Modular Fan regulator (2 module)
95/6 A switch (Piano Type)
1015/16 A switch (Piano type)
113 pin 5/6 A socket outlet (Piano type)
126 pin 15/16 A socket outlet (Piano type)
131 or 2 Module Cover plate
143 Module Cover plate
156 Module Cover plate
168 Module Cover plate
1712 Module Cover plate
181200mm ceiling fan, BEE 5 star rating, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
19150 Watt. LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy 105 <120 lm/Watt).
20300 mm sweep 900 rpm heavy duty exhaust fan
21Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm
223 x 4 sq. mm
23Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 A, 16 KA,TPMCCB
24150 A, 16 KA,TPMCCB
25250 A,36KA,FPMCCB
26Supplying & lowering of 2.2KW/3 HP submersible pump set capable of delivering 175-35 LPM at a head of 39-73 mtrs for operation on 415 volts, 3 phase, 50 Hz, AC supply, in the existing borewell with the help of chain pulley and tripod stand i/c providing gasket, GI nut and bolts in the pipe line complete with testing etc. as required.
27Supplying & lowering of 5 HP Open well submersible pump set capable of delivering 258-60 LPM at a head of 20-34 mtrs for operation on 415 volts, 3 phase, 50 Hz, AC supply, in the existing open well with the help of chain pulley and tripod stand i/c providing gasket, GI nut and bolts in the pipe line complete with testing etc. as required.
28Supplying and installation of 5 HP DOL starter (with wideband coil) submersible pump controllar in sheet steel enclosure suitable for operation on 415 +/- 10% volts 3 Phase 50 +/- 5% HZ AC supply, overload relay, current rating from 6-10 Amp, single phase preventor, Ampere meter, Voltmeter i/c connections with copper conductor cable glands/lugs etc testing and commissioning as required.
29Supplying and installation of 7.5 HP DOL starter (with wideband coil) submersible pump controllar in sheet steel enclosure suitable for operation on 415 +/- 10% volts 3 Phase 50 +/- 5% HZ AC supply, overload relay, current rating from 13-22 Amp, single phase preventor, Ampere meter, Voltmeter i/c connections with copper conductor cable glands/lugs etc testing and commissioning as required.
30Lifting of existing submersible bore well / open well 3 HP to 10 HP capacity Pump set from the bore well with the help of chain pulley block & tripod stand i/c cartage charge at site from the work shop.
31Lowering of 3 HP to 10 HP capacity bore well/open well pumpset in the bore well with the help of chain pulley block and tripod stand i/c cartage charge pump set from work shop to site.
32Servicing and Overhauling of 3/5 HP 3 Phase Motor Pump set i/c varnising ,greasing , oiling and making Coupling alignment i/c replacement of bearing etc and re-installation the same, testing and commissioning etc complete as reqd.
33Rewinding of 5HP capacity 3 phase multi-stage submersible / mono-submersible pump-set with suitable size water proof copper conductor wire i/c brazing metalling turning & polishing of shaft, replacement of GM bearing bush, thrust bush, thrust plate, necessary sleeves, pads etc. i/c buy back of dismantled material and making connection, testing and commissioning etc. complete as reqd.
34Supply & fixing of 3 Core 6.0 sq.mm. flat water proof copper conductor submersible cable i/c connections etc. as required.
35Routine maintenance of Kirloskar make 125 KVA DG set with all accessories, complete electrical system, Alternator. AMF Panel including checking and repairing of faults, cleaning etc as per terms and conditions attached.
36Supply of following items for Servicing of 01 No. 125 KVA DG set (Kirloskar make) as and when required. i/c dismantling of old material & credit of old dismantle etc complete as required. Oil Filter spinon 1 liter
37Fuel Filter 1 liter
38Safety Air Filter Element
39Primary Filter Element
40Premixed Coolant 5 ltr
41Petronas Urania 1000 CH-4 10 L
42Petronas Urania 1000 CH-4 20 L
43Exide Battery 150 AH
4412 volt static battery charger
45Under voltage relay 415 VAC
46Less credit for dismantle material recevied from the work.5/6A distorted switch (Modular/Piano type)
4715/16A distorted switch (Modular/Piano type)
485/6A distorted Socket (Modular/Piano type)
4915/16A distorted socket (Modular/Piano type)
50Fan Regulator (Modular/Piano type)
511/2/3/6/8/12 modular damaged cover plate
5240/63/100 TP/FP MCB disorted/damaged
53Assorted size Copper wire
54300 mm damaged exhaust fan
551200 mm damaged ceiling fan
563/5 HP submersible Pump
573/5HP Pump Starter Please Enable Macros to View BoQ information

Other Detail

Information Source https://govtprocurement.delhi.gov.in
Download FileName File Description File Size
Download 8868a2a7-8b8b-4384-8a31-81df13829bcb.html Tender Documents 0 KB
Download BOQ_385756.xls Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.