Indian Tenders

Tender Notice

TDR 55304914
Tendering Authority Power Development Department
Tender No ED-I/e-NIT/18 of 2026-27 dated 30.04.2026
Tender ID 2026_PDD_309141_1
Tender Brief Tender For Item Rate Boq Boq_Ver3.0 Item Rate Normal Inr Only Inr Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Executive Engineer Jpdcl Electric Div-I, Parade, Jammu. Survey, Supply, Transportation, Erection, Testing & Commission
City Jammu
State Jammu And Kashmir
Document Fees INR 5000 /-
EMD INR 1238580.0 /-
Tender Value Refer document
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Item Rate Boq Boq_Ver3.0 Item Rate Normal Inr Only Inr Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Executive Engineer Jpdcl Electric Div-I, Parade, Jammu. Survey, Supply, Transportation, Erection, Testing & Commissioning For Permanent Restoration Of Damages Occurred To Electrical Infrastructure Due To Heavy Rainfall/Flash Flood From 25Th Of August To 3Rd Of September 2025 Under The Jurisdiction Of Electric Division Div.-I (Jpdcl) Jammu On Turn Key Basis Under Sasci. Contract No:Ed-I/E-Nit/18 Of 2026-27 Dated 30.04.2026 Bidder Name : Price Schedule (This Boq Template Must Not Be Modified/Replaced By The Bidder And The Same Should Be Uploaded After Filling The Relevent Columns, Else The Bidder Is Liable To Be Rejected For This Tender. Bidders Are Allowed To Enter The Bidder Name And Values Only ) Number # Text # Text # Number # Text # Number Number Text Text # Number # Text# Text # Number # Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number # Number # Text Text Number # Number # Date Number # Number # Text # , Item Description , Work A- Supply, Erection, Testing And Commissioning For Replacement Of Damaged/ Washed-Away 9Mtr Long St Poles On Ht Network , St Poles 9 Mtr Long (St -410 Sp 33) , Gi V Cross-Arm With Top Brackets Including Clamp , Gi Channel X-Arm Including Clamp And Braces , 11 Kv Polymer Composite Pin Insulators 12Kv, 5Kn, Lighting Impulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm , Galvanized Nuts & Bolts , Danger Plates With Clamps , Anti Climbing Device With Clamps , Earthing Complete By Gi Pipe 40 Mm Or Gi Rod 20Mm 2.5Mtr Long Through Gi Strip , Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.5Cum/Pole , Red-Oxide , Aluminium Paint , Work B- Supply, Erection, Testing And Commissioning For Replacement Of Damaged/Washed-Away 8Mtr Long Plain Cement Concrete Poles On Lt Network , Plain Cement Concrete Poles 8 Mtr Long (Wl 200 Kg) , Gi U-Clamps For Shackle Insulator , 16 Kn Polymer Shackle Insulator , Galvanized Nuts & Bolts , Work C- Supply, Erection, Testing And Commissioning For Replacement Of Damaged/ Washed-Away 8Mtr Long St Poles On Lt Network , St Poles 8 Mtr Long (St-410 Sp 15) , Gi U-Clamps For Shackle Insulator , 16 Kn Polymer Shackle Insulator , Galvanized Nuts & Bolts , Earthing Complete By Gi Pipe 40Mm Or Gi Rod 20Mm 2.5Mtr Long Through Gi Strip , Cement Bottoming 1:2:4 Mix As Per Rec Standards .45 Cum/Pole , Red Oxide , Aluminium Paint , Aluminium Jointing Sleeves , Lt Line Spacer , Galvanized Stay Set With 50X8mm Stay Clamp, Guy Insulator (2Nos), Anchor Plate (200X200x6mm), Nuts & Bolts, 2Nos Turn Buckles,1.8Mm Long, 16Mm Diameter Solid Gs Stay Rod And 7/3.15Mm Dia Gi Standard Wire Complete , Work D- Supply, Erection, Testing And Commissioning For Replacement Of Damaged/Washed-Away 120Mmsq, 11 Kv Ab Cable , 11 Kv, Three Core 120Mm² Aluminium Round Wire Armoured Ab Cable , Heat Shrinkable Outdoor Cable Termination Kit , Earthing Complete By Gi Pipe 40Mm Or Gi Rod 20Mm 2.5Mtr Long Through Gi Strip. , Mid Span Straight Through Jointing Kit For 11 Kv Abc , Work E- Supply, Erection, Testing And Commissioning For Replacement Of Damaged/Washed-Away Acsr Conductor , Acsr Weasel Conductor (30 Mm²) , Acsr Rabbit Conductor (50 Mm²) , Work F- Supply, Erection, Testing And Commissioning For Re-Erection Of 63 Kva Uprooted Distribution Sub-Station (Transformer Available At Site) , 11/0.433 Kv, 3 Phase 63 Kva Distribution Transformer With Bi-Mettalic Terminal Connectors (Energy Level-2) Aluminium Wound And With Lv Cable Box Having Detachable Aluminium Gland Plate (Labour Only). , Gapless Surge Arrester, 9 Kv, 10 Ka, La With Polymer Housing Station Type , 11 Kv Go, Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical Type , St Poles 9 Mtr Long (St -410 Sp 33) , 11 Kv Horn Gap Fuse Set 3 Phase, 200Amp , 11 Kv Polymeric Composite Disc Insulators 12Kv, Min Following Load 45 Kn, Lightening Impulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm With Fittings , Galvanized Nuts & Bolts , Earthing Of Sub-Station -Excavation Of Earth Pit Of Diameter 650Mm And Deapth 3000Mm, Installation Of Earthing Pipe Of 40Mm Nominal Bore And 4Mm Wall Thickness And Length 2.5M Long As Per Is 1239 Gi Strip For Neutral Earthing Of Size 25Mm Into 3 Mm For Connection Of Transformer Body, Go Set And Lightening Arrestor As Per Is 2629/85, Gi Nuts & Bolts, Refilled With Earth Enhancement Material , 11 Kv Polymeric Composite Pin Insulators 12Kv, 5Kn, Lighting Inpulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm , 70 Mmsq Pvc Cable Single Core , Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.5Cum/Pole , Work G- Supply, Erection, Testing And Commissioning For Re-Erection Of 250 Kva Uprooted Distribution Sub-Station (Transformer Available At Site) , 11/0.433 Kv, 3 Phase 250 Kva Distribution Transformer With Bi-Mettalic Terminal Connectors (Energy Level-2) Copper Wound And With Lv Cable Box Having Detachable Aluminium Gland Plate (Labour Only). , Gapless Surge Arrester, 9 Kv, 10 Ka, La With Polymer Housing Station Type , 11 Kv Go, Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical Type , St Poles 9 Mtr Long (St -410 Sp 33) , 11 Kv Horn Gap Fuse Set 3 Phase, 200 annual periodical maintenance , 11 Kv Polymeric Composite Disc Insulators 12Kv, Min Following Load 45 Kn, Lightening Impulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm With Fittings , Galvanized Nuts & Bolts , Earthing Of Sub-Station -Excavation Of Earth Pitof Diameter 650Mm And Deapth 3000Mm, Installation Of Earthing Pipe Of 40Mm Nominal Bore And 4Mm Wall Thickness And Length 2.5M Long As Per Is 1239 Gi Strip For Neutral Earthing Of Size 25Mm Into 3Mm For Connection Of Transformer Body, Go Set And Lightening Arrestor As Per Is 2629/85, Gi Nuts & Bolts, Refilled With Earth Enhancement Material , 11 Kv Polymeric Composite Pin Insulators 12Kv, 5Kn,Lighting Inpulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm , 185 Mmsq Pvc Cable Single Core 2(Ckt) , Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.5Cum/Pole , Work H- Supply, Erection, Testing And Commissioning For Re-Erection Of 400Kva Uprooted Distribution Sub-Station (Transformer Available At Site) , 11/0.433 Kv, 3 Phase 400 Kva Distribution Transformer With Bi-Mettalic Terminal Connectors (Energy Level-2) Copper Wound And With Lv Cable Box Having Detachable Aluminium Gland Plate (Labour Only). , Gapless Surge Arrester, 9 Kv, 10 Ka, La With Polymer Housing Station Type , 11 Kv Go, Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical Type , St Poles 9 Mtr Long (St -410 Sp 33) , 11 Kv Horn Gap Fuse Set 3 Phase, 200 annual periodical maintenance , 11 Kv Polymeric Composite Disc Insulators 12Kv, Min Following Load 45 Kn, Lightening Impulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm With Fittings , Galvanized Nuts & Bolts , Earthing Of Sub-Station -Excavation Of Earth Pit Of Diameter 650Mm And Deapth 3000Mm, Installation Of Earthing Pipe Of 40Mm Nominal Bore And 4Mm Wall Thickness And Length 2.5M Long As Per Is 1239 Gi Strip For Neutral Earthing Of Size 25Mm Into 3 Mm For Connection Of Transformer Body, Go Set And Lightening Arrestor As Per Is 2629/85, Gi Nuts & Bolts, Refilled With Earth Enhancement Material , 11 Kv Polymeric Composite Pin Insulators 12Kv, 5Kn,Lighting Inpulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm , 240 Mmsq Pvc Cable Single Core 2(Ckt) , Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.5Cum/Pole , Work I- Supply, Erection, Testing And Commissioning For Re-Creation Of Washed Away/Damaged 25Kva Distribution Sub-Station , 11/0.433 Kv, 3 Phase 25 Kva Distribution Transformer With Bi-Mettalic Terminal Connectors (Energy Level-2) Aluminium Wound And With Lv Cable Box Having Detachable Aluminium Gland Plate. , Gapless Surge Arrester, 9 Kv, 10 Ka, La With Polymer Housing Station Type , 11 Kv Go, Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical Type , 11 Kv Horn Gap Fuse Set 3 Phase, 200 annual periodical maintenance , 50Mm² Cable, 1.1 Kv Grade, Pvc Insulated Stranded Conductor Frls Type. , St Poles 9 Mtr Long (St -410 Sp 33) , 11 Kv Polymeric Composite Disc Insulators 12Kv, Min Following Load 45 Kn, Lightening Impulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm With Fittings , Gi Channel/Angle/Flat Of Sizes Including Clamps , Galvanized Nuts & Bolts , Earthing Of Sub-Station -Excavation Of Earth Pitof Diameter 650Mm And Deapth 3000Mm, Installation Of Earthing Pipe Of 40Mm Nominal Bore And 4Mm Wall Thickness And Length 2.5M Long As Per Is 1239 Gi Strip For Neutral Earthing Of Size 25Mm Into 3 Mmfor Connection Of Transformer Body, Go Set And Lightening Arrestor As Per Is 2629/85, Gi Nuts & Bolts, Refilled With Earth Enhancement Material , Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.5Cum/Pole , Sundry Items Like Aluminium Lugs, Jumpers, Binding Tape Aluminium Thimbles Etc. , Work J- Supply, Erection, Testing And Commissioning For Re-Creation Of Washed Away/Damaged 63Kva Distribution Sub-Station , 11/0.433 Kv, 3 Phase 63 Kva Distribution Transformer With Bi-Mettalic Terminal Connectors (Energy Level-2) Aluminium Wound And With Lv Cable Box Having Detachable Aluminium Gland Plate. , Gapless Surge Arrester, 9 Kv, 10 Ka, La With Polymer Housing Station Type , 11 Kv Go, Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical Type , 11 Kv Horn Gap Fuse Set 3 Phase, 200 annual periodical maintenance , 70Mm² Cable, 1.1 Kv Grade, Pvc Insulated Stranded Conductor Frls Type. , St Poles 9 Mtr Long (St -410 Sp 33) , 11 Kv Polymeric Composite Disc Insulators 12Kv, Min Following Load 45 Kn, Lightening Impulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm With Fittings , Gi Channel/Angle/Flat Of Sizes Including Clamps , Galvanized Nuts & Bolts , Earthing Of Sub-Station -Excavation Of Earth Pitof Diameter 650Mm And Deapth 3000Mm, Installation Of Earthing Pipe Of 40Mm Nominal Bore And 4Mm Wall Thickness And Length 2.5M Long As Per Is 1239 Gi Strip For Neutral Earthing Of Size 25Mm Into 3 Mmfor Connection Of Transformer Body, Go Set And Lightening Arrestor As Per Is 2629/85, Gi Nuts & Bolts, Refilled With Earth Enhancement Material , 11 Kv Polymeric Composite Pin Insulators 12Kv, 5Kn,Lighting Inpulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm , Galvanized Stay Set With 50X8mm Stay Clamp, Guy Insulator (2 Nos), Anchor Plate (200X200x6mm) Nuts & Bolts, 2Nos Turn Buckles,1.8Mm Long, 16Mm Diameter Solid Gs Stay Rod And 7/3.15Mm Dia Gi Standard Wire Complete , Wedge Connectors/ Pg Calmps , Danger Plates With Clamps , Gi Barbed Wire For Anti Climbing , Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.5Cum/Pole , Painting Of Poles Red-Oxide , Painting Of Poles Aluminium Paint , Sundry Items Like Aluminium Lugs, Jumpers, Binding Tape Aluminium Thimbles Etc. , Work K- Supply, Erection, Testing And Commissioning For Re-Creation Of Washed Away/Damaged 100Kva Distribution Sub-Station , 11/0.433 Kv, 3 Phase 100 Kva Distribution Transformer With Bi-Mettalic Terminal Connectors (Energy Level-2) Aluminium Wound And With Lv Cable Box Having Detachable Aluminium Gland Plate. , Gapless Surge Arrester, 9 Kv, 10 Ka, La With Polymer Housing Station Type , 11 Kv Go, Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical Type , 11 Kv Horn Gap Fuse Set 3 Phase, 200 annual periodical maintenance , 185 Mm² Cable, 1.1 Kv Grade, Pvc Insulated Stranded Conductor Frls Type. , St Poles 9 Mtr Long (St -410 Sp 33) , 11 Kv Polymeric Composite Disc Insulators 12Kv, Min Following Load 45 Kn, Lightening Impulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm With Fittings , Gi Channel/Angle/Flat Of Sizes Including Clamps , Galvinized Nuts & Bolts , Earthing Of Sub-Station -Excavation Of Earth Pit Of Diameter 650Mm And Deapth 3000Mm, Installation Of Earthing Pipe Of 40Mm Nominal Bore And 4Mm Wall Thickness And Length 2.5M Long As Per Is 1239 Gi Strip For Neutral Earthing Of Size 25Mm Into 3 Mmfor Connection Of Transformer Body, Go Set And Lightening Arrestor As Per Is 2629/85, Gi Nuts & Bolts, Refilled With Earth Enhancement Material , 11 Kv Polymeric Composite Pin Insulators 12Kv, 5Kn,Lighting Inpulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm , Galvanized Stay Set With 50X8mm Stay Clamp, Guy Insulator (2 Nos), Anchor Plate (200X200x6mm) Nuts & Bolts, 2 Nos Turn Buckles,1.8Mm Long, 16Mm Diameter Solid Gs Stay Rod And 7/3.15Mm Dia Gi Standard Wire Complete , Wedge Connectors/ Pg Calmps , Danger Plates With Clamps , Gi Barbed Wire For Anti Climbing , Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.5Cum/Pole , Painting Of Poles Red-Oxide , Painting Of Poles Aluminium Paint , Sundry Items Like Aluminium Lugs, Jumpers, Binding Tape Aluminium Thimbles Etc. , Work L- Supply, Erection, Testing And Commissioning For Re-Creation Of Washed Away/Damaged 250Kva Distribution Sub-Station , 11/0.433 Kv, 3 Phase 250 Kva Distribution Transformer With Bi-Mettalic Terminal Connectors (Energy Level-2) Copper Wound And With Lv Cable Box Having Detachable Aluminium Gland Plate. , Gapless Surge Arrester, 9 Kv, 10 Ka, La With Polymer Housing Station Type , 11 Kv Go, Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical Type , 11 Kv Horn Gap Fuse Set 3 Phase, 200 annual periodical maintenance , 185Mm² Cable (2-Ckt), 1.1 Kv Grade, Pvc Insulated Stranded Conductor Frls Type. , St Poles 9 Mtr Long (St -410 Sp 33) , 11 Kv Polymeric Composite Disc Insulators 12Kv, Min Following Load 45 Kn, Lightening Impulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm With Fittings , Gi Channel/Angle/Flat Of Sizes Including Clamps , Galvanized Nuts & Bolts , Earthing Of Sub-Station -Excavation Of Earth Pitof Diameter 650Mm And Deapth 3000Mm, Installation Of Earthing Pipe Of 40Mm Nominal Bore And 4Mm Wall Thickness And Length 2.5M Long As Per Is 1239 Gi Strip For Neutral Earthing Of Size 25Mm Into 3 Mmfor Connection Of Transformer Body, Go Set And Lightening Arrestor As Per Is 2629/85, Gi Nuts & Bolts, Refilled With Earth Enhancement Material , 11 Kv Polymeric Composite Pin Insulators 12Kv, 5Kn,Lighting Inpulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm , Galvanized Stay Set With 50X8mm Stay Clamp, Guy Insulator (2 Nos), Anchor Plate (200X200x6mm) Nuts & Bolts, 2 Nos Turn Buckles,1.8Mm Long, 16Mm Diameter Solid Gs Stay Rod And 7/3.15Mm Dia Gi Standard Wire Complete , Wedge Connectors/ Pg Calmps , Danger Plates With Clamps , Gi Barbed Wire For Anti Climbing , Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.5Cum/Pole , Painting Of Poles Red-Oxide , Painting Of Poles Aluminium Paint , Sundry Items Like Aluminium Lugs, Jumpers, Binding Tape Aluminium Thimbles Etc. , Work M- Supply, Erection, Testing And Commissioning For Laying Of Ht Line On 9 Mtr Long St Poles Using Acsr Rabbit Conductor Due To Shifting/ Realignment Of Ht Network At Sinking Roads/ Landslide Prone Areas , St Poles 9 Mtr Long (St -410 Sp 33) , Gi V Cross-Arm With Top Brackets Including Clamp , Gi Channel X-Arm Including Clamp And Braces , Acsr Rabbit Conductor (50 Mm²) , Pg Clamps For 50Mm² Acsr Conductor , 11 Kv Polymer Composite Pin Insulators 12Kv, 5Kn, Lighting Impulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm , 11 Kv Polymer Composite Disc Insulator 12Kv,Min Falling Load 45Kn, Lighting Impulse 75Kv Positive And 80Kv Negative, Creepage Distance 320Mm , Galvanized Nuts & Bolts , Danger Plates With Clamps , Anti Climbing Device With Clamps , Earthing Complete By Gi Pipe 40 Mm Or Gi Rod 20 Mm 2.5 Mtr Long Through Gi Strip , Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.5Cum/Pole , Red-Oxide , Aluminium Paint , Aluminium Jointing Sleeves , Galvanized Stay Set With 50X8mm Stay Clamp, Guy Insulator (2 Nos), Anchor Plate (200X200x6mm) Nuts & Bolts, 2 Nos Turn Buckles,1.8Mm Long, 16Mm Diameter Solid Gs Stay Rod And 7/3.15Mm Dia Gi Standard Wire Complete , Work N-Supply, Erection, Testing And Commissioning For Laying Of Lt Line On 8 Mtr Long St Poles Using Acsr Rabbit Conductor Due To Shifting/ Realignment Of Ht Network At Sinking Roads/ Landslide Prone Areas , St Poles 8 Mtr Long (St-410 Sp 15) , Gi U-Clamps For Shackle Insulator , Acsr Rabbit Conductor (50 Mm²) , 16 Kn Polymer Shackle Insulator , Galvanized Nuts & Bolts , Danger Plates , Anti Climbing Devices With Clamps , Earthing Complete By Gi Pipe 40 Mm Or Gi Rod 20 Mm 2.5 Mtr Long Through Gi Strip , Cement Bottoming 1:2:4 Mix As Per Rec Standards .45 Cum/Pole , Red Oxide , Aluminium Paint , Aluminium Jointing Sleeves , Lt Line Spacer , Galvanized Stay Set With 50X8mm Stay Clamp, Guy Insulator (2 Nos), Anchor Plate (200X200x6mm) Nuts & Bolts, 2 Nos Turn Buckles,1.8Mm Long, 16Mm Diameter Solid Gs Stay Rod And 7/3.15Mm Dia Gi Standard Wire Complete Total In Figures 0.0 0.0 Inr Zero Only Quoted Rate In Figures Select 0.0 0.0 Zero Only Quoted Rate In Words Inr Zero Only

Key Dates

Publish Date 30-04-2026
Last Date of Bid Submission 20-05-2026
Tender Opening Date 21-05-2026

Contact Information

Company Name Power Development Department
Contact Person Executive Engineer JPDCL ED-I Parade Jammu
Address Office of Executive Engineer JPDCL ED-I Parade Jammu

BOQ Items

Name of Work:-
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Executive Engineer JPDCL Electric Div-I, Parade, Jammu. “Survey, Supply, Transportation, Erection, Testing & Commissioning for Permanent Restoration of damages occurred to Electrical Infrastructure due to heavy rainfall/Flash Flood from 25th of August to 3rd of September 2025 under the Jurisdiction of Electric Division Div.-I (JPDCL) Jammu on Turn Key Basis under SASCI.” Contract No:ED-I/e-NIT/18 of 2026-27 Dated 30.04.2026 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT #
2Item Description
3Work A- Supply, Erection, Testing and commissioning for Replacement of Damaged/ Washed-away 9mtr long ST Poles on HT Network
4ST Poles 9 Mtr Long (ST -410 SP 33)
5GI V cross-arm with top Brackets including clamp
6GI Channel X-arm including clamp and braces
711 KV Polymer composite Pin Insulators 12KV, 5KN, Lighting impulse 75KV positive and 80KV negative, creepage distance 320mm
8Galvanized nuts & Bolts
9Danger Plates with Clamps
10Anti Climbing Device with Clamps
11Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5mtr long through GI Strip
12Cement Bottoming 1:2:4 mix as per REC Standards 0.5cum/pole
13Red-Oxide
14Aluminium Paint
15Work B- Supply, Erection, Testing and commissioning for Replacement of Damaged/Washed-away 8mtr Long PCC Poles on LT Network
16PCC Poles 8 Mtr Long (WL 200 Kg)
17GI U-Clamps for Shackle Insulator
1816 kN Polymer Shackle Insulator
19Galvanized nuts & Bolts
20Work C- Supply, Erection, Testing and commissioning for Replacement of Damaged/ Washed-away 8mtr long ST Poles on LT Network
21ST Poles 8 Mtr Long (ST-410 SP 15)
22GI U-Clamps for Shackle Insulator
2316 KN Polymer Shackle Insulator
24Galvanized nuts & Bolts
25Earthing Complete by GI Pipe 40mm or GI Rod 20mm 2.5mtr long through GI Strip
26Cement Bottoming 1:2:4 mix as per REC standards .45 cum/pole
27Red oxide
28Aluminium Paint
29Aluminium Jointing sleeves
30LT Line Spacer
31Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2Nos), anchor plate (200X200X6mm), Nuts & Bolts, 2nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete
32Work D- Supply, Erection, Testing and commissioning for Replacement of Damaged/Washed-away 120mmsq, 11 KV AB Cable
3311 KV, Three core 120mm² Aluminium round wire Armoured AB Cable
34Heat Shrinkable Outdoor Cable Termination Kit
35Earthing Complete by GI Pipe 40mm or GI Rod 20mm 2.5mtr long through GI Strip.
36Mid Span Straight Through Jointing Kit for 11 KV ABC
37Work E- Supply, Erection, Testing and commissioning for Replacement of Damaged/Washed-away ACSR Conductor
38ACSR Weasel Conductor (30 mm²)
39ACSR Rabbit Conductor (50 mm²)
40Work F- Supply, Erection, Testing and commissioning for Re-erection of 63 KVA Uprooted Distribution Sub-Station (Transformer available at site)
4111/0.433 KV, 3 Phase 63 KVA Distribution Transformer with Bi-Mettalic Terminal Connectors (Energy Level-2) Aluminium wound and with LV Cable Box having detachable Aluminium Gland Plate (Labour only).
42Gapless Surge Arrester, 9 KV, 10 KA, LA with Polymer housing Station Type
4311 KV GO, AB Switch 3 Phase, 3 Pole, 200 amp, vertical type
44ST Poles 9 Mtr Long (ST -410 SP 33)
4511 KV Horn Gap Fuse Set 3 Phase, 200Amp
4611 KV Polymeric Composite Disc Insulators 12KV, min following load 45 KN, Lightening impulse 75KV positive and 80KV negative, creepage distance 320mm with Fittings
47Galvanized Nuts & Bolts
48Earthing of Sub-Station -Excavation of earth pit of diameter 650mm and deapth 3000mm, installation of earthing pipe of 40mm nominal bore and 4mm wall thickness and length 2.5m long as per IS 1239 GI Strip for neutral earthing of size 25mm into 3 mm for connection of transformer body, GO Set and lightening arrestor as per IS 2629/85, GI Nuts & Bolts, refilled with earth enhancement material
4911 KV Polymeric composite Pin Insulators 12KV, 5KN, lighting inpulse 75KV positive and 80KV negative, creepage distance 320mm
5070 mmsq PVC Cable single core
51Cement Bottoming 1:2:4 mix as per REC Standards 0.5cum/pole
52Work G- Supply, Erection, Testing and commissioning for Re-erection of 250 KVA Uprooted Distribution Sub-Station (Transformer available at site)
5311/0.433 KV, 3 Phase 250 KVA Distribution Transformer with Bi-Mettalic Terminal Connectors (Energy Level-2) Copper wound and with LV Cable Box having detachable Aluminium Gland Plate (Labour only).
54Gapless Surge Arrester, 9 KV, 10 KA, LA with Polymer housing Station Type
5511 KV GO, AB Switch 3 Phase, 3 Pole, 200 amp, vertical type
56ST Poles 9 Mtr Long (ST -410 SP 33)
5711 KV Horn Gap Fuse Set 3 Phase, 200 amp
5811 KV Polymeric Composite Disc Insulators 12KV, min following load 45 KN, Lightening impulse 75KV positive and 80KV negative, creepage distance 320mm with Fittings
59Galvanized Nuts & Bolts
60Earthing of Sub-Station -Excavation of earth pitof diameter 650mm and deapth 3000mm, installation of earthing pipe of 40mm nominal bore and 4mm wall thickness and length 2.5m long as per IS 1239 GI Strip for neutral earthing of size 25mm into 3mm for connection of transformer body, GO Set and lightening arrestor as per IS 2629/85, GI Nuts & Bolts, refilled with earth enhancement material
6111 KV Polymeric composite Pin Insulators 12KV, 5KN,lighting inpulse 75KV positive and 80KV negative, creepage distance 320mm
62185 mmsq PVC Cable single core 2(ckt)
63Cement Bottoming 1:2:4 mix as per REC Standards 0.5cum/pole
64Work H- Supply, Erection, Testing and commissioning for Re-erection of 400KVA Uprooted Distribution Sub-Station (Transformer available at site)
6511/0.433 KV, 3 Phase 400 KVA Distribution Transformer with Bi-Mettalic Terminal Connectors (Energy Level-2) Copper wound and with LV Cable Box having detachable Aluminium Gland Plate (Labour only).
66Gapless Surge Arrester, 9 KV, 10 KA, LA with Polymer housing Station Type
6711 KV GO, AB Switch 3 Phase, 3 Pole, 200 amp, vertical type
68ST Poles 9 Mtr Long (ST -410 SP 33)
6911 KV Horn Gap Fuse Set 3 Phase, 200 amp
7011 KV Polymeric Composite Disc Insulators 12KV, min following load 45 KN, Lightening impulse 75KV positive and 80KV negative, creepage distance 320mm with Fittings
71Galvanized Nuts & Bolts
72Earthing of Sub-Station -Excavation of earth pit of diameter 650mm and deapth 3000mm, installation of earthing pipe of 40mm nominal bore and 4mm wall thickness and length 2.5m long as per IS 1239 GI Strip for neutral earthing of size 25mm into 3 mm for connection of transformer body, GO Set and lightening arrestor as per IS 2629/85, GI Nuts & Bolts, refilled with earth enhancement material
7311 KV Polymeric composite Pin Insulators 12KV, 5KN,lighting inpulse 75KV positive and 80KV negative, creepage distance 320mm
74240 mmsq PVC Cable single core 2(ckt)
75Cement Bottoming 1:2:4 mix as per REC Standards 0.5cum/pole
76Work I- Supply, Erection, Testing and commissioning for Re-Creation of Washed Away/Damaged 25KVA Distribution Sub-Station
7711/0.433 KV, 3 Phase 25 KVA Distribution Transformer with Bi-Mettalic Terminal Connectors (Energy Level-2) Aluminium wound and with LV Cable Box having detachable Aluminium Gland Plate.
78Gapless Surge Arrester, 9 KV, 10 KA, LA with Polymer housing Station Type
7911 KV GO, AB Switch 3 Phase, 3 Pole, 200 amp, vertical type
8011 KV Horn Gap Fuse Set 3 Phase, 200 amp
8150mm² Cable, 1.1 kV Grade, PVC Insulated Stranded Conductor FRLS type.
82ST Poles 9 Mtr Long (ST -410 SP 33)
8311 KV Polymeric Composite Disc Insulators 12KV, min following load 45 KN, Lightening impulse 75KV positive and 80KV negative, creepage distance 320mm with Fittings
84GI Channel/Angle/Flat of sizes including clamps
85Galvanized Nuts & Bolts
86Earthing of Sub-Station -Excavation of earth pitof diameter 650mm and deapth 3000mm, installation of earthing pipe of 40mm nominal bore and 4mm wall thickness and length 2.5m long as per IS 1239 GI Strip for neutral earthing of size 25mm into 3 mmfor connection of transformer body, GO Set and lightening arrestor as per IS 2629/85, GI Nuts & Bolts, refilled with earth enhancement material
87Cement Bottoming 1:2:4 mix as per REC Standards 0.5cum/pole
88Sundry items like Aluminium Lugs, Jumpers, Binding Tape Aluminium Thimbles etc.
89Work J- Supply, Erection, Testing and commissioning for Re-Creation of Washed Away/Damaged 63KVA Distribution Sub-Station
9011/0.433 KV, 3 Phase 63 KVA Distribution Transformer with Bi-Mettalic Terminal Connectors (Energy Level-2) Aluminium wound and with LV Cable Box having detachable Aluminium Gland Plate.
91Gapless Surge Arrester, 9 KV, 10 KA, LA with Polymer housing Station Type
9211 KV GO, AB Switch 3 Phase, 3 Pole, 200 amp, vertical type
9311 KV Horn Gap Fuse Set 3 Phase, 200 amp
9470mm² Cable, 1.1 kV Grade, PVC Insulated Stranded Conductor FRLS type.
95ST Poles 9 Mtr Long (ST -410 SP 33)
9611 KV Polymeric Composite Disc Insulators 12KV, min following load 45 KN, Lightening impulse 75KV positive and 80KV negative, creepage distance 320mm with Fittings
97GI Channel/Angle/Flat of sizes including clamps
98Galvanized Nuts & Bolts
99Earthing of Sub-Station -Excavation of earth pitof diameter 650mm and deapth 3000mm, installation of earthing pipe of 40mm nominal bore and 4mm wall thickness and length 2.5m long as per IS 1239 GI Strip for neutral earthing of size 25mm into 3 mmfor connection of transformer body, GO Set and lightening arrestor as per IS 2629/85, GI Nuts & Bolts, refilled with earth enhancement material
10011 KV Polymeric composite Pin Insulators 12KV, 5KN,lighting inpulse 75KV positive and 80KV negative, creepage distance 320mm
101Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete
102Wedge Connectors/ PG Calmps
103Danger Plates with Clamps
104GI Barbed wire for Anti Climbing
105Cement Bottoming 1:2:4 mix as per REC Standards 0.5cum/pole
106Painting of Poles Red-Oxide
107Painting of Poles Aluminium Paint
108Sundry items like Aluminium Lugs, Jumpers, Binding Tape Aluminium Thimbles etc.
109Work K- Supply, Erection, Testing and commissioning for Re-Creation of Washed Away/Damaged 100KVA Distribution Sub-Station
11011/0.433 KV, 3 Phase 100 KVA Distribution Transformer with Bi-Mettalic Terminal Connectors (Energy Level-2) Aluminium wound and with LV Cable Box having detachable Aluminium Gland Plate.
111Gapless Surge Arrester, 9 KV, 10 KA, LA with Polymer housing Station Type
11211 KV GO, AB Switch 3 Phase, 3 Pole, 200 amp, vertical type
11311 KV Horn Gap Fuse Set 3 Phase, 200 amp
114185 mm² Cable, 1.1 kV Grade, PVC Insulated Stranded Conductor FRLS type.
115ST Poles 9 Mtr Long (ST -410 SP 33)
11611 KV Polymeric Composite Disc Insulators 12KV, min following load 45 KN, Lightening impulse 75KV positive and 80KV negative, creepage distance 320mm with Fittings
117GI Channel/Angle/Flat of sizes including clamps
118Galvinized Nuts & Bolts
119Earthing of Sub-Station -Excavation of earth pit of diameter 650mm and deapth 3000mm, installation of earthing pipe of 40mm nominal bore and 4mm wall thickness and length 2.5m long as per IS 1239 GI Strip for neutral earthing of size 25mm into 3 mmfor connection of transformer body, GO Set and lightening arrestor as per IS 2629/85, GI Nuts & Bolts, refilled with earth enhancement material
12011 KV Polymeric composite Pin Insulators 12KV, 5KN,lighting inpulse 75KV positive and 80KV negative, creepage distance 320mm
121Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete
122Wedge Connectors/ PG Calmps
123Danger Plates with Clamps
124GI Barbed wire for Anti Climbing
125Cement Bottoming 1:2:4 mix as per REC Standards 0.5cum/pole
126Painting of Poles Red-Oxide
127Painting of Poles Aluminium Paint
128Sundry items like Aluminium Lugs, Jumpers, Binding Tape Aluminium Thimbles etc.
129Work L- Supply, Erection, Testing and commissioning for Re-Creation of Washed Away/Damaged 250KVA Distribution Sub-Station
13011/0.433 KV, 3 Phase 250 KVA Distribution Transformer with Bi-Mettalic Terminal Connectors (Energy Level-2) Copper wound and with LV Cable Box having detachable Aluminium Gland Plate.
131Gapless Surge Arrester, 9 KV, 10 KA, LA with Polymer housing Station Type
13211 KV GO, AB Switch 3 Phase, 3 Pole, 200 amp, vertical type
13311 KV Horn Gap Fuse Set 3 Phase, 200 amp
134185mm² Cable (2-CKT), 1.1 kV Grade, PVC Insulated Stranded Conductor FRLS type.
135ST Poles 9 Mtr Long (ST -410 SP 33)
13611 KV Polymeric Composite Disc Insulators 12KV, min following load 45 KN, Lightening impulse 75KV positive and 80KV negative, creepage distance 320mm with Fittings
137GI Channel/Angle/Flat of sizes including clamps
138Galvanized Nuts & Bolts
139Earthing of Sub-Station -Excavation of earth pitof diameter 650mm and deapth 3000mm, installation of earthing pipe of 40mm nominal bore and 4mm wall thickness and length 2.5m long as per IS 1239 GI Strip for neutral earthing of size 25mm into 3 mmfor connection of transformer body, GO Set and lightening arrestor as per IS 2629/85, GI Nuts & Bolts, refilled with earth enhancement material
14011 KV Polymeric composite Pin Insulators 12KV, 5KN,lighting inpulse 75KV positive and 80KV negative, creepage distance 320mm
141Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete
142Wedge Connectors/ PG Calmps
143Danger Plates with Clamps
144GI Barbed wire for Anti Climbing
145Cement Bottoming 1:2:4 mix as per REC Standards 0.5cum/pole
146Painting of Poles Red-Oxide
147Painting of Poles Aluminium Paint
148Sundry items like Aluminium Lugs, Jumpers, Binding Tape Aluminium Thimbles etc.
149Work M- Supply, Erection, Testing and commissioning for Laying of HT Line on 9 Mtr Long ST Poles using ACSR Rabbit conductor due to Shifting/ Realignment of HT Network at sinking roads/ Landslide prone areas
150ST Poles 9 Mtr Long (ST -410 SP 33)
151GI V cross-arm with top Brackets including clamp
152GI Channel X-arm including clamp and braces
153ACSR Rabbit Conductor (50 mm²)
154PG Clamps for 50mm² ACSR conductor
15511 KV Polymer composite Pin Insulators 12KV, 5KN, Lighting impulse 75KV positive and 80KV negative, creepage distance 320mm
15611 KV Polymer composite Disc Insulator 12KV,min falling load 45KN, Lighting impulse 75KV positive and 80KV negative, creepage distance 320mm
157Galvanized nuts & Bolts
158Danger Plates with Clamps
159Anti Climbing Device with Clamps
160Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip
161Cement Bottoming 1:2:4 mix as per REC Standards 0.5cum/pole
162Red-Oxide
163Aluminium Paint
164Aluminium Jointing sleeves
165Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete
166Work N-Supply, Erection, Testing and commissioning for Laying of LT Line on 8 Mtr Long ST Poles using ACSR Rabbit conductor due to Shifting/ Realignment of HT Network at sinking roads/ Landslide prone areas
167ST Poles 8 Mtr Long (ST-410 SP 15)
168GI U-Clamps for Shackle Insulator
169ACSR Rabbit Conductor (50 mm²)
17016 kN Polymer Shackle Insulator
171Galvanized nuts & Bolts
172Danger Plates
173Anti Climbing Devices with Clamps
174Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI Strip
175Cement Bottoming 1:2:4 mix as per REC standards .45 cum/pole
176Red oxide
177Aluminium Paint
178Aluminium Jointing sleeves
179LT Line Spacer
180Galvanized Stay Set with 50X8mm Stay clamp, Guy insulator (2 Nos), anchor plate (200X200X6mm) Nuts & Bolts, 2 nos turn buckles,1.8mm long, 16mm diameter solid GS stay rod and 7/3.15mm dia GI standard wire complete Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

Other Detail

Information Source https://jktenders.gov.in
Download FileName File Description File Size
Download 07f877ac-4129-4416-aa22-601b38ce2ac6.html Tender Documents 0 KB
Download BOQ_1000973.xls Tender Documents 0 KB
Download sbd18.pdf Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.