| 1 | Renovation work of Main Building in Public Health Center Tejgaon District- Raebareli (U.P.) |
| 2 | MAINTENANCE WORK |
| 3 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead |
| 4 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 5 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 6 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand. |
| 7 | Ground Floor |
| 8 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.-2.25 |
| 9 | Ground Floor |
| 10 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 11 | Size of Tile 600x600 mm |
| 12 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). |
| 13 | Size of Tile 600x600 mm |
| 14 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 15 | Providing and fixing rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm. Including grouting the joints with white cement and matching pigments etc, complete. |
| 16 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 17 | Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 18 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 19 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 20 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface) |
| 21 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 22 | Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45 Kg per square metre of area for each course, second course of roofing felt type 3 grade-I (hessian based self finished bitumen felt) and fourth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic decimeter per square metre, including preparation of surface but excluding grading complete with : |
| 23 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 24 | PLUMBING WORK |
| 25 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required |
| 26 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 27 | W.C. pan with ISI marked white plastic seat and lid |
| 28 | Providing and fixing white vitreous china extended wall mounted water closet , of size 780x370x690 mm of approve shape i ncluding providing & fixing white vitreous china cistern with dual flush fitting of flushing capacity 3/6 litre(adjustable to 4/8 liters) including seat cover, and cistern fitting, nuts, bolts and gasket etc. complete. |
| 29 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 30 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. |
| 31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 32 | Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge. |
| 33 | 15mm nominal bore |
| 34 | Providing and fixing CP Brass 32 mm size Bottal Trap of approved quality & make and as per thedirection of Enginer-in-charge. |
| 35 | Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms. |
| 36 | Providing & fixing 600x120x5 mm glass self with edges round off, supported on anodiesd aluminium angle framewith C.P. brass bracket and guard rail complete fixed with 40 mmlong screws, rawl plugs etc, complete. |
| 37 | Providing & fixing 32 # G.I. Pipes spout including cutting & making good the walls etc. |
| 38 | Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) around P.V.C /C.I. Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) |
| 39 | 110/75 mm diameter |
| 40 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. |
| 41 | 110mm diameter |
| 42 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. |
| 43 | Bend 87.5 degree |
| 44 | 110 mm Bend |
| 45 | Shoe (Plain) |
| 46 | 110 mm Shoe |
| 47 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. |
| 48 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 49 | 110mm |
| 50 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 51 | Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. (internal work) |
| 52 | Exposed on wall |
| 53 | 25mm dia nominal bore |
| 54 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. |
| 55 | 25mm dia nominal bore. |
| 56 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 57 | internal work -Exposed on wall |
| 58 | 20mm dia nominal outer dia pipes |
| 59 | 25mm dia nominal outer dia pipes |
| 60 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. |
| 61 | Concealed work including cutting chases and making good the walls etc. |
| 62 | 15mm dia nominal outer dia pipes |
| 63 | 20mm dia nominal outer dia pipes |
| 64 | 25mm dia nominal outer dia pipes |
| 65 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 |
| 66 | 15mm nominal bore |
| 67 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 |
| 68 | 15mm nominal bore |
| 69 | Providing & fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 70 | Providing and fixing gun metal gate valve with wheel of approved quality. |
| 71 | 25mm dia nominal bore |
| 72 | 20 mm dia nominal bore |
| 73 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 74 | 25 mm nominal bore |
| 75 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 76 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, |
| 77 | in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. |
| 78 | Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. |
| 79 | Providing, laying and joining glazed stone ware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. |
| 80 | 100 mm diameter |
| 81 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. |
| 82 | 100mm dia SW pipe |
| 83 | Providing and laying Non pressure NP2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. |
| 84 | 150mm dia. R.C.C. pipe |
| 85 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of S.W./R.C.C. pipes including bed concrete as per standard design |
| 86 | 150mm diameter R.C.C. Pipe |
| 87 | Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design: |
| 88 | 150 x 100 mm. size P type |
| 89 | With Sewer bricks conforming to IS : 4885 |
| 90 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design |
| 91 | Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). |
| 92 | With FPS bricks of class designation 75 |
| 93 | (i) For Sewer Line |
| 94 | Extra for depth of man hole size 90x80 cm |
| 95 | Inside size 90x120 cm & 90 cm deep including C.I. cover with frame (medium duty) total wt. of cover & frame to be not less than 116 Kg (wt. of cover 58 Kg & wt. of frame 58 Kg. |
| 96 | Extra for depth of man hole size 90x120 cm |
| 97 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design |
| 98 | With 20x20 mm square bar |
| 99 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before with supply and cost of other fIttlings such as elbow,bend,tee and y-tee,Cowel including supply of all marerial labour and T&P. Required for proper completion of work. |
| 100 | 75 mm O.D. |
| 101 | 110 mm O.D. |
| 102 | Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. |
| 103 | Providing & Fixing C.P. Brass Health Faucet -Make-Jaquar |
| 104 | SEPTIC TANK |
| 105 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge. |
| 106 | In all kind of soil upto 1.5m depth |
| 107 | In all kind of soil upto 1.5m to 3.0m. depth |
| 108 | Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size) |
| 109 | Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) |
| 110 | Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. |
| 111 | Suspended floors, roofs, landings, balconies and access platform. |
| 112 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 113 | 12mm cement plaster on rough side of mix 1:3 (1 cement : 3 coarse sand) |
| 114 | Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. |
| 115 | Providing and fixing C.I. tee at the inlet and outlet of septic tank. |
| 116 | Providing & fixing 75mm dia vent pipes. |
| 117 | Providing & fixing of 75mm dia cast iron terminal guard. |
| 118 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 119 | M.D. -10- Circular shape 500mm internal diameter |
| 120 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks |
| 121 | ELECTRICAL WORK |
| 122 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 123 | Group C |
| 124 | Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 125 | 2X1.5 sqmm + 1x1.5 sqmm earth wire |
| 126 | 2X2.5 sqmm + 1x 2.5 sqmm earth wire |
| 127 | 2X4.0 sqmm + 1x 4.0 sqmm earth wire |
| 128 | 2X6.0 sqmm + 1x 6.0 sqmm earth wire |
| 129 | 2X10.0 sqmm + 1x 6.0 sqmm earth wire |
| 130 | Supplying and drawing following pair 0.5 sqmm FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. |
| 131 | 2 Pair |
| 132 | Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 133 | Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: |
| 134 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. |
| 135 | Telephone socket outlet |
| 136 | TV antenna socket outlet |
| 137 | Bell Push |
| 138 | Supply and fixing of two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 139 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 140 | Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. |
| 141 | 1 or 2 module(75mm X 75 mm ) |
| 142 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch,connection etc. as required. |
| 143 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,connection etc. as required. |
| 144 | Supplying and fixing 3 pin 5 A ceiling rose on the existing junction box/woodedn block including connectionetc. as required. |
| 145 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 146 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. Including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 147 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 148 | Installation of exhaust fan in the existing opening, including making good the damage, connections, testing, commissioning etc. as required. |
| 149 | upto 450 mm sweep. |
| 150 | Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes. |
| 151 | Providing and fixing circular/Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screwed, one loc at the conrners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 152 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Disect Current(BLDC) motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value(CM/M/W) minimum 6, Air delivery minimum 210 Cum/Min, 350 RPM(tolerance as per IS: 374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 153 | Providing & fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in in existing panel board including drilling holes in cubical panel, making connections,etc as required. |
| 154 | 100 A, 30 KA, FPMCCB |
| 155 | Supplying and fixing following way, Horizontal type three pole and neutral MCB distribution board, 415 volts on surface /recess complete with , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). |
| 156 | 8 way, Double door |
| 157 | Supplying and fixing following way, Horizontal type three pole and neutral MCB distribution board, 415 volts on surface /recess complete with , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). |
| 158 | 8 way (4 + 24), Double door |
| 159 | Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 160 | Single Pole |
| 161 | Double Pole |
| 162 | Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required. |
| 163 | Supply and fixing 20 amp, 240 volts, SPN industrial Type, socket outlet ,With 2 pole and earth ,metal enclosed plug top along with 20 amp. `C` series SPMCB , in sheet steel encosure, on surface or in recess with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 164 | Supplying and fixing Cable End Box(Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution borad, 415 Volts, on surface/recess, complete with testing and commissoning ect. as required. |
| 165 | For 8 way, Double Door TPNMCBDB |
| 166 | Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required. |
| 167 | Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 168 | Providing & fixing 6 SWG dia G.I. on surface or in recess for loop earthing as required. |
| 169 | Supplying & making end termination with brass compression gland and aluminium lugs for the following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 170 | 3.5 X 35 sqmm. (32mm) |
| 171 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. |
| 172 | 100 mm Dia |
| 173 | Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top as directed by Engineer-Incharge ,complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 174 | 35 sqmm 3.5 core |
| 175 | Supply & fixing of IP 20, Front Lit, Mid Power SMD type LED Light, recess/Surface mounting round 10 Watt to 15 Watt, Cut out Min. 125 mm, Height Min 40 mm, LED Down Lighter having Power coated die cast aluminium housing with heat sink, High purity/transmisivity UV Stabilized Non yellowish diffuser/Refelctor for uniform light distribution, detachable driver set, suitable for 24 Hr Continuous Operation, complete in all respects. |
| 176 | 1200-1800 system lumens,>120 Lm/W, PF>0.95, THD <10% at full load, CRI>80, >300V over voltage protection, 2.5 KV internal Surge Protection, with 5 years warrantee. CAT-AAA |
| 177 | Supply and fixing of LED Tube Light with heavy Duty Metal Box type Tube Light Fitting 1x22 watt suitable for upto 1x22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect. |
| 178 | 2620 system lumens,with fully covered diffuser type>120 lm/w PF>.95,THD<10%,CRI>80, sheet thickness min 0.8mm, Tube with aluminium heat sink, >300V over voltage protection,2.5 KV internal Surge protection, with 5 years Warrantee.CAT. - AAA |
| 179 | Supply and Fixing of Recess/pendent mounting having 1'X4' size 36 to 46 Watt seamlessly interateds LED luminiew with High purity/transmisivity UV stabilized Non yellowish diffuser/refelctor for uniform light distribution, integral/detachable driver set, open and short circuit protection, suitable for 24 Hr Continious Operation, complete in all respects. |
| 180 | 4320-5520 system lumens,>120 lm/W, PF>.95, THD<10% at full load, CRI>80,>300V over voltage protection, 4 KV internal Surge protection, with 5 years Warrantee.CAT. - AAA |
| 181 | Supply and fixing of water tight oblong 10 Watt LED Bulkhead luminaire having pressure die cast housing with driver set confirming to IP 65 and above Protection. IK 08, High purity/transmisivity UV stabilized Non yellowish diffuser/refelctor for uniform light distribution, detachable driver set, open and short circuit protection, suitable for 24 Hr Continious Operation, complete in all respects. |
| 182 | 1200 system lumens,>120 lm/W, PF>.95, THD<10%, CRI>70,>300V over voltage protection, 4 KV internal Surge protection, metal housing with 5 years Warrantee.CAT. - AAA |
| 183 | Supply & Fixing of 1X17 W mirror light complete in all respects. Make-Philips or Eq |
| 184 | Supply of AC 230/250 Volts, 50 Hz 55w 1400 rpm exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required.Make: Havells-STANDARD -Refresh Air-SPS |
| 185 | 300mm sweep. |
| 186 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 1 No. 16 A modular switch and 2 Nos. 6A modular socket & 1 No.6 pin 5/6 & 15/16 A modular socket outlet (recessed/ surface). ,connection etc. as required.-For Computer |
| 187 | S/f of 10/20 pair Junction Boxes for Floors and building with Krone connectors , with connection and punching of same |
| 188 | GST Extra as applicable Please Enable Macros to View BoQ information |