Indian Tenders

Tender Notice

TDR 55300990
Tendering Authority Military Engineer Services
Tender No 8951/E8
Tender ID 2026_MES_762876_1
Tender Brief Tender For Day To Day Maintenance And Repair Such As Switch Board, Switches, Mcb, Mcb Dbs, Led Tube Light Fittings, Post Top Lantern Fittings, Street Lights, Tube Lights, Security Lights, Gate Lights, Frp Junction Boxes, Electric Geysers, Air Circula
City Palghar
State Maharashtra
Document Fees INR 500 /-
EMD INR 35800.0 /-
Tender Value Refer document
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Day To Day Maintenance And Repair Such As Switch Board, Switches, Mcb, Mcb Dbs, Led Tube Light Fittings, Post Top Lantern Fittings, Street Lights, Tube Lights, Security Lights, Gate Lights, Frp Junction Boxes, Electric Geysers, Air Circulators, Ceiling Fans, Exhaust Fans Etc At Powai, Worli, Cg Malad, Mtnl, Cgsd Mankhurd, Murud Janjira And Panvel Under Ge (I) (Cg) Daman

Key Dates

Publish Date 30-04-2026
Last Date of Bid Submission 18-05-2026
Tender Opening Date 21-05-2026

Contact Information

Company Name Military Engineer Services
Contact Person GARRISON ENGINEER DAMAN
Address Garrison Engineer Daman, Tat Rakshak Vihar, Dalwada, Nani Daman Post, Daman (UT) PIN 396210

BOQ Items

Name of Work:- DAY TO DAY MAINTENANCE AND REPAIR SUCH AS SWITCH BOARD, SWITCHES, MCB, MCB DBS, LED TUBE LIGHT FITTINGS, POST TOP LANTERN FITTINGS, STREET LIGHTS, TUBE LIGHTS, SECURITY LIGHTS, GATE LIGHTS, FRP JUNCTION BOXES, ELECTRIC GEYSERS, AIR CIRCULATORS, CEILING FANS, EXHAUST FANS ETC AT POWAI, WORLI, CG MALAD, MTNL, CGSD MANKHURD, MURUD JANJIRA AND PANVEL UNDER GE (I) (CG) DAMAN
Sl. No. Item Description
1Taking down carefully copper/ aluminium point wiring (light ,fan ,socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets ,light fittings etc. Removing the material from work site and making good the disturbed portion/ surface of wall/ floor/ ceiling etc to match with the existing surface / location.all as directed.
2M&L for point wiring with 1.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed FRLSH cable, ISI marked 1100 volts grade draw through and including rigid non metallic PVC casing and caping ( of suitable size) and all necessary fittings accessories fixed on walls/ceilng etc including 1.5 sqmm single core PVC insulated unsheathed cable (green colour) 1100 volts grade with multi stranded copper conductor earth continuity conductor to commom earth and connected to earth continuity conductor to common earth and connected to earth dolly terminated in and including sunk pressed steel terminal box for modular plate and including modular plate complete including cutting chases, refilling and making good to disturbed surfaces all as specified and as directed, for one light/fan/bell point controlled by one switch.
3All as per item no. 2 here in befor but for One three pin switch socket outlet 5 amps on same board.
4All as per item no. 2 here in before but 2.5 sqmm for One three pin switch socket outlet 5 amps on independent board.
5All as per item no. 2 but for two way light point wiring controlled with two 2 way 5 amps switches
6M&L for point wiring using proper colour coding complete all as specified with 1100 Volts grade, 2.5 Sqmm PVC insulated, FRLS, unsheathed, wire confirming to IS-694,PartII, ISI marked with Multistranded copper conductor in and including PVC casing caping (suitable size ) ISI marked ,with all accessaries on wall/ceiling/floor/ roof etc, sunk pressed steel terminal box not less than 2 mm thick, 50 mm deep, covered with 3 mm thick plastic laminated, ISI marked, sheet top cover fastened with chromium plated brass screw including 2.5 Sqmm, PVC insulated, FRLSH, unsheathed, multistranded, copper conductor 1100 Volts grade, green colour, continuous earth wire connected to common earth doly for 15 Amps, 3 Pin, socket outlet independent all as specified and directed.
7S & F modular switch, single pole, ISI marked, one way 6 Amps 1 module 250 volts , complete all as specified and directed.
8S & F modular switch 15 amps, ISI marked, flush type, multipurpose 1way, 1module , complete all as specified and directed.
9S & F modular socket 5 Amps 2 module,2/3 pin ISI marked, 240 Volts, all as specified and directed.
10S & F modular socket 6/16 Amps and 2/3 pin, 2 modules ,ISI marked 240 Volt , complete all as specified and directed.
11S & F modular type fan regulator, 2 Module 230 volts, ISI marked , stepped and connecting up complete all as specified and directed.
12S&F in repair switch modular type,5 amps, 2 ways, ISI marked, 250 volts , complete all as specified and directed.
13S & F modular bell push , 1 module ,6 Amps , ISI marked, 250 volts , complete all as specified and directed.Make for Modular Swicth/Sockets/Regulators:Anchor Roma/ Crabtree/Legrand
14S & F fan regulators, Normal Type 230 volts, ISI marked, stepped and flush type and connecting up , complete all as specified and directed.
15S&F Switch piano , flush type ,single pole, ISI marked ,one way 5 Amps ,230 volts , complete all as specified and directed.
16S&F in repair bell push, flush button , single pole ,ISI marked, one way 5 Amps, 230 volts , complete all as specified and directed.
17S&F in repair switch socket combination 2 in one, 5 Amps flush type ISI marked 240 Volt all as specified.
18S&F in repair Socket 5 Amp flush type piano, 2 module , 3 pin flush type ISI marked 240 Volts all as specified and direcetd.
19S&F in repair switch socket combination, ISI marked flush type, multipurpose 5/15 amps , controlled by one switch , complete all as specified and directed.
20S&F in repair ceiling rose,3 phase/PVC/polycarbonate isolated body, ISI marked , complete all as specified and directed. Make for item Piano type Switches/Sockets/Regulators/Ceiling rose:- 16 to 21 Anchor/Legrand/Havells
21S&F in repair bell ding dong AC 230 Volts, ISI marked single pole all as specified.
22Supply and fix new white cover modular plate with frame of 12 module alll as specified.Make for Modular Plate and Box:-Anchor Roma/Crabtree/Legrand
23supply and fix new white cover modular plate with frame of 8 module all as specified.
24supply and fix new white cover modular plate with frame of 6 module all as specified.
25supply and fix new white cover modular plate with frame of 4 module all as specified.
26supply and fix new white cover modular plate with frame of 3 module all as specified.
27supply and fix new white cover modular plate with frame of 2 module all as specified.
28supply and fix new white cover modular plate with frame of 1 module all as specified.
29Supply and Fixing Modular PVC rectangular block for mounting, switches, sockets,fan regulator etc. with 3 mm thick plastic laminated sheet suitable for 12 module white cover plate.
30Supply and Fixing Modular PVC rectangular block for mounting, switches, sockets,fan regulator etc. with 3 mm thick plastic laminated sheet suitable for 8 module white cover plate.
31Supply and Fixing Modular PVC rectangular block for mounting, switches, sockets,fan regulator etc. with 3 mm thick plastic laminated sheet suitable for 6 module white cover plate.
32Supply and Fixing Modular PVC rectangular block for mounting, switches, sockets,fan regulator etc. with 3 mm thick plastic laminated sheet suitable for 4 module white cover plate.
33Supply and Fixing Modular PVC rectangular block for mounting, switches, sockets,fan regulator etc. with 3 mm thick plastic laminated sheet suitable for 3 module white cover plate.
34Supply and Fixing Modular PVC rectangular block for mounting, switches, sockets,fan regulator etc. with 3 mm thick plastic laminated sheet suitable for 2 module white cover plate.
35Supply and Fixing Modular PVC rectangular block for mounting, switches, sockets,fan regulator etc. with 3 mm thick plastic laminated sheet suitable for 1 module white cover plate.
36Supply and fix new white colour PVC Box along with Back Cover with frame suitable for mounting of 3 One Module piano type switches and one two module regulator completed all as specified and directed by Engr-in-Charge.
37Supply and fix new white colour PVC Box along with Back Cover with frame suitable for mounting of 3 One Module piano type switches completed all as specified and directed by Engr-in-Charge.
38Taking down old unserviceable MCB SP 6-32 amp 240 volt and supply and fix new MCB,SP, 6-32 amp, 240 Volt, 50HZ, 10 KA, `C` Series, ISI marked making electrical connection with the help of Lugs/thimbles ,complte all as speacifiedand directed.Make :Havells/L&T/Siemens/Legrand . Make I No 34 to 40 :- Standard/L&T/ Legrand/Schneider/Havells/Siemens ISI Marked
39Taking down old unserviceable MCB SPand Supply and fix new MCB,SP, 63 Amp, 240 Volt, 50HZ, 10 KA, `C` Series, ISI marked making electrical connection with the help of Lugs/thimbles ,complte all as speacifiedand directed.Make :Havells/L&T/Siemens/Legrand . Make I No 34 to 40 :- Standard/L&T/ Legrand/Schneider/Havells/Siemens ISI Marked
40Taking down old unserviceable MCB and supply and fix new MCB,SPN, 6-32 amp, 240 Volt, 50HZ, 10 KA, `C` Series, ISI marked making electrical connection with the help of Lugs/thimbles all as speacified.Make :Havells/L&T/Siemens/Legrand .
41Taking down old unserviceable MCB SPN and Supply and fix new MCB,SPN, 40 amp, 240 Volt, 50HZ, 10 KA, `C` Series, ISI marked making electrical connection with the help of Lugs/thimbles all as speacified.Make :Havells/L&T/Siemens/Legrand .
42Taking down old unserviceable MCB SPN and Supply and fix new MCB,SPN, 63 amp, 240 Volt, 50HZ, 10 KA, `C` Series, ISI marked making electrical connection with the help of Lugs/thimbles all as speacified.Make :Havells/L&T/Siemens/Legrand .
43Taking down old unserviceable MCB TPN 63 amp and supply and fix new MCB,TPN, 63 Amp, 415 Volt, 50 HZ, 10 KA, `C` Series, ISI marked, making electrical connection with the help of Lugs/thimbles all as speacified. Make :Havells/L&T/Siemens/Legrand .
44Taking down old unserviceable MCCB 100 amp and supply and fix new MCCB,415 volt,3 pole 16 KA capacity, 63 Amps, complete all as specified and directed.Make : Siemens /Havells /Legrand/L & T .
45Taking down old unserviceable MCCB 63 amp and supply and fix new MCCB 63A,415 volt,3 pole 16 KA capacity, 63 Amps, complete all as specified and directed.Make : Siemens /Havells /Legrand/L & T . Please Enable Macros to View BoQ information
46Taking down old unserviceable MCCB 63 amp and supply and fix new MCCB 63A,415 volt,3 pole 16 KA capacity, 63 Amps, complete all as specified and directed.Make : Siemens /Havells /Legrand/L & T . Please Enable Macros to View BoQ information

Other Detail

Information Source https://defproc.gov.in/nicgep/app
Download FileName File Description File Size
Download b1fe3088-3ec1-4410-8d01-6e0b7e7452a0.html Tender Documents 0 KB
Download BOQ_854536.xls Tender Documents 0 KB
Download RAR.rar Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.