Indian Tenders

Tender Notice

TDR 55275429
Tendering Authority Military Engineer Services
Tender No 8001/790/E8
Tender ID 2026_MES_762724_1
Tender Brief Corrigendum : Tender For Repair/ Maintenance Of External Water Supply Distribution System Including Reconditioning Of Irp, Chemical Dosing Pump, Compressor, Starter Panel, Rising And Distribution Pipe Lines And Other Connected Items Installed At Pump Houses At Af
City Dinjan
State Assam
Document Fees INR 500 /-
EMD INR 60000.0 /-
Tender Value INR 30 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Repair/ Maintenance Of External Water Supply Distribution System Including Reconditioning Of Irp, Chemical Dosing Pump, Compressor, Starter Panel, Rising And Distribution Pipe Lines And Other Connected Items Installed At Pump Houses At Af Stn Dinjan Under Ge (Af) Mohanbari

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 12-05-2026 Amendment Other 19-05-2026
2 12-05-2026 Amendment Other 26-05-2026

Key Dates

Publish Date 12-05-2026
Last Date of Bid Submission 26-05-2026

Contact Information

Company Name Military Engineer Services
Contact Person GE (AF) Mohanbari
Address Garrison Engineer (AF) Mohanbari Mohanbari Post Dibrugarh Assam 786012

BOQ Items

Name of Work:- REPAIR/ MAINT OF EXTERNAL WATER SUPPLY DISTRIBUTION SYSTEM INCLUDING RECONDITIONING OF IRP, CHEMICAL DOSING PUMP, COMPRESSOR, STARTER PANEL, RISING AND DISTRIBUTION PIPE LINES AND OTHER CONNECTED ITEMS INSTALLED AT PUMP HOUSES AT AF STN DINJAN UNDER GE (AF) MOHANBARI
Sl. No. Item Description
1Excavation in trenches n.exc 1.50 mtr wide and n.exc 1.50 mtr deep for taking out/ laying of pipe and getting out in soft soil strata including making good to the disbturbed surfaces such as hardstanding, footpath/ pavments complete all as specified and directed.
2Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm spread any type of soil complete all as specified and directed.
3Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
4Taking up or down old GI/ MS/ CI/ DI/ PPR tubing of 100/ 110 mm bore dia and connections including cleaning for refixng (serviceable) or removal to store complete all as specified and directed.
5All as per here-in-above item No 4.00 but bore of Pipe 80 mm dia GI pipe and 90mm dia PPR pipe complete all as specified and directed.
6All as per here-in-above item No 4.00 but bore of Pipe 50 mm dia GI pipe and 63mm dia PPR pipe complete all as specified and directed.
7All as per here-in-above item No 4.00 but bore of Pipe 25 mm dia GI pipe and 32/40mm dia PPR pipe complete all as specified and directed.
8Relaying of GI/MS/DI/CI/PPR pipe of any size obtained from item No 4 to 7 at any location complete all as specified and directed.
9M&L for 100 mm bore GI tubing medium grade in trenches/ floor/ pillar and connection in old or news position as per site requirement including fittings like socket/ union/ tee/ reducer Nipple etc complete all as specified and directed.
10All as per here-in-above item Srl No. 9.00, but bore 80 mm complete all as specified and directed.
11All as per here-in-above item Srl No. 9.00, but bore 50 mm complete all as specified and directed.
12All as per here-in-above item Srl No. 9.00, but bore 25 mm complete all as specified and directed.
13Supply and lay 3 layer (inner antimicrobial, outer UV stabilized) ISI marked, IS-15801, PP-R pipes SDR 11 (PN-10) and PP-R plain fittings laid in trenches/ walls/ cellings or laying in floors complete of size outer dia 110 mm including all fittings complete all as specified and directed.
14Supply and lay 3 layer (inner antimicrobial, outer UV stabilized) ISI marked ,IS-15801, PP-R pipes SDR 11 (PN-10) and PP-R plain fittings in trenches/walls/cellings or laying in floors complete of size outer dia 90 mm including all fittings complete all as specified and directed.
15Supply and lay 3 layer (inner antimicrobial, outer UV stabilized) ISI marked, IS-15801, PP-R pipes SDR 11 (PN-10) and PP-R plain fittings in trenches/ walls/ cellings or laying in floors complete of size outer dia 63 mm including all fittings complete all as specified and directed.
16Supply and lay 3 layer (inner antimicrobial, outer UV stabilized) ISI marked, IS-15801, PP-R pipes SDR 11 (PN-10) and PP-R plain fittings in trenches/ walls/ cellings or laying in floors complete of size outer dia 40 mm including all fittings complete all as specified and directed.
17Supply and lay 3 layer (inner antimicrobial, outer UV stabilized) ISI marked ,IS-15801, PP-R pipes SDR 11 (PN-10) and PP-R plain fittings in trenches/ walls/ cellings or laying in floors complete of size outer dia 32 mm including all fittings complete all as specified and directed.
18M&L for 50 mm bore gate valve cast bronze alloy screwed down high pressure with clutch handle screwed both ends for iron pipe including taking out of old gate valve complete all as specified and directed.
19All as per here-in-above item Srl No. 18, but size 25 mm bore complete all as specified and directed.
20S&F in repair PP-R Gate valves (brass insert) 90 mm outer dia of pipe complete all as specified and directed.
21S&F in repair PP-R Gate valves (brass insert) 63 mm outer dia of pipe complete all as specified and directed.
22S&F in repair PP-R Gate valves (brass insert) 40 mm outer dia of pipe complete all as specified and directed.
23S&F in repair PP-R Gate valves (brass insert) 32 mm outer dia of pipe complete all as specified and directed.
24S&F in repair PP-R Gate valves (brass insert) 25 mm outer dia of pipe complete all as specified and directed.
25M&L for run lead joint for CI pipes or specials suitable for 150 mm bore pipes incl spun yarn or any other consumable required at site including cleaning of old complete all as specified and directed.
26All as per here-in-above item Srl No. 25, but size 100 mm bore complete all as specified and directed.
27All as per here-in-above item Srl No. 25., but size 80 mm bore complete all as specified and directed.
28M&L for repairing of 80 mm dia sluice valve by opening for rectifying leakage, refacing, regrinding, replacement of galand packing, gasket, nut, bolt, washer, wheel and refixing in its original position after testing complete all as specified and directed.
29M&L for repairing of 100 mm dia sluice valve by opening for rectifying leakage, refacing, regrinding, replacement of galand packing, gasket, nut, bolt, washer, wheel and refixing in its original position after testing complete all as specified and directed.
30M&L for repairing of 150 mm dia sluice valve by opening for rectifying leakage, refacing, regrinding, replacement of galand packing, gasket, nut, bolt, washer, wheel and refixing in its original position after testing complete all as specified and directed.
31S&F in repair 80 mm bore CI Sluice valve PN -1.6 with Spindle Iron (heavy duty) Wheel head and both ends flanged and MS nut bolts and washers and pair of rubber/ fiber gasket and fixed in position complete all as specified and directed.
32All as per here-in-above item Srl No. 31, but size 100 mm bore complete all as specified and directed.
33S&F in repair of butterfly valve of size 100 mm dia including nut, bolt, washers complete all as specified and directed.
34S&F in repair PVC Sheathed, PVC insulated flat submersible copper cable, water proof best quality of size 3 core, 10 Sqmm, 1100 volts grade for connection to submersible pump set complete all as specified and directed. Please Enable Macros to View BoQ information
35S&F in repair PVC Sheathed, PVC insulated flat submersible copper cable, water proof best quality of size 3 core, 10 Sqmm, 1100 volts grade for connection to submersible pump set complete all as specified and directed. Please Enable Macros to View BoQ information

Other Detail

Information Source https://defproc.gov.in/nicgep/app
Download FileName File Description File Size
Download 194bf558-b802-4282-9064-85a47858e976.html Tender Documents 0 KB
Download BOQ_854363.xls Tender Documents 0 KB
Download Tender.pdf Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.