Indian Tenders

Tender Notice

TDR 55275390
Tendering Authority Indian Institute Of Technology
Tender No IIT/IW/EM/NIT/96/2025-26
Tender ID 2026_IITKG_906917_1
Tender Brief Tender For Electrical Maintenance And Renovation Work In Wave Energy Laboratory Of Oena Department Iit Kharagpur.
City Kharagpur
State West Bengal
Document Fees Refer document
EMD INR 40200.0 /-
Tender Value INR 20.10 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Electrical Maintenance And Renovation Work In Wave Energy Laboratory Of Oena Department Iit Kharagpur.

Key Dates

Publish Date 29-04-2026
Last Date of Bid Submission 19-05-2026
Tender Opening Date 20-05-2026

Contact Information

Company Name Indian Institute Of Technology
Contact Person Superintending Engineer (EM)
Address Office of the Superintending Engineer (EM), Estate (EM) Works Section, Old Building IIT KGP

BOQ Items

Name of Work:- Electrical Maintenance and Renovation Work in Wave Energy Laboratory of OENA Department IIT Kharagpur.
Sl. No. Item Description
1Wiring for light point / ceiling fan point /wall fan point including 6 amp 3 pin socket/call bell point / exhaust fan point with 1.5 sq mm FRLS /HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable size GI box and earthing the point with 1.5 sq mm,1.1 kV, FRLS/HFFR PVC insulated copper conductor single core cable etc as required.
2Upto 6 metres ( Group A )
3Above 6 metres ( Group B )
4Above 9 metres ( Group C )
5Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor , single core cable in surface / recessed medium class PVC conduit as required .
62 X 1.5 sq mm + 1 X 1.5 sq mm for earth wire
72 X 2.5 sq mm + 1 X 2.5 sq mm for earth wire
82 X 4 sq mm + 1 X 4 sq mm for earth wire
92 X 6 sq mm + 1 X 6 sq mm for earth wire
102 X 16 sq mm + 1 X 6 sq mm for earth wire
114 X 6 sq mm + 2 X 6 sq mm for earth wire
124 X 16 sq mm + 2 X 6 sq mm for earth wire
13Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required.
1420 mm
1525 mm
1632 mm
17Supplying and fixing metal box/ Junction box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as require(ISI Approved).
1875 mm X 75 mm X 60 mm deep
19100 mm X 100 mm X 60 mm deep
20150 mm X 150 mm X 60 mm deep
21Supplying and fixing following sizes/modules, GI / PVC box along with modular base & cover plate for modular switches in recess etc as required.
221 or 2 Module (75 mm X 75 mm )
233 Module (100 mm X 75 mm )
246 Module (200 mm X 77 mm )
2512 Module (200 mm X 150 mm )
26Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.
275 /6 Amps Switch
2815 /16 Amps Switch
293 pin 5 /6 Amps Socket Outlet
306 pin 15 / 16 Amps Socket Outlet
31Blanking Plate :-
32Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
33Supplying and fixing single Pole blanking plate in the existing MCB DB complete etc. as required.
34Supplying & fixing suitable size GI box/ PVC box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required with earthing attachment (Complete unit) for Split/Window Airconditioner.
35Installation, Testing, Commissioning of wall bracket/ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. including 3 X1.5 sq mm FRLS/ HFFR PVC insulated copper conductor single core cable and earthing etc as required.
36Supplying and fixing of extra conduit down rod of 20 cm Length (heavy gauge) GI pipe 15 mm dia wiring with 3 X 1.5 sq mm single core FRLS/ HFFR PVC cu cable including cutting, threading and painting etc as required.(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored.)
37Hot Dipped Galvanized Iron Cable Tray :- Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders/ fixing on wall with suitable G.I. angle i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required.
38100 mm width X 50 mm depth X 1.6 mm thickness
39150 mm width X 50 mm depth X 1.6 mm thickness
40Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders/ fixing on wall with suitable G.I. angle i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required.
41100 mm width X 50 mm depth X 1.6 mm thickness
42101 mm width X 50 mm depth X 1.6 mm thickness
43Supplying and installing following size of Perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (Galvanisation thichness not less than 50 microns) perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers G.I. suspenders/ fixing on wall with suitable G.I. angle i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required.
44100 mm width X 50 mm depth X 1.6 mm thickness
45101 mm width X 50 mm depth X 1.6 mm thickness
46Supplying and fixing double door 12 Way Vertical TPN MCB Distribution board for MCCB incomer upto 250 A with IP-42/43 protection, concealed /surface in wall after cutting the wall/on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
47Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
48Providing and fixing following rating and breaking capacity and pole MCCB with adjustable thermal and fixed magnetic setting and terminal spreaders link in existing PCC Panel /MCCB DB/MCCB SS Enclosure including drilling holes in cubicle panel, making connections, etc. as required.
49250 A,36 KA, FP MCCB
50Supply of one number Alminium conductor PVC insulated and PVC sheathed / XLPE, Armoured Power Cable A2XFY of 1.1 kV grade,, Confirming to IS: 1554/7098 (Part -1) 1988 with latest amendments.
512X 10 sq mm
523.5X 25 sq mm
533.5X150 sq mm
54Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on Wall Surface as required incl. S+F of 1 X 10 SWG rust free GI wire for E.C.C making holes and manding good the damages to original finish incl painting.( Cable Dept supply)
55Upto 35 sq mm ( clamped with 1 mm thick rust free saddle)
56Above 35 sq mm and upto 95 sq mm (clamped with 25 X 3 mm rust free MS flat clamp)
57Above 95 sq mm and upto 185 sq mm (clamped with 25/40 X 3 mm rust free MS flat clamp)
58Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on Cable Tray along with S+F of 10 SWG GI wire as earth wire as required.
59Upto 35 sq. mm (clamped with 1mm thick rust free saddle @ 3 sets per metre.)
60Above 35 sq. mm and upto 95 sq. mm (clamped with 25 X 3mm rust free MS flat clamp @ 3 sets per metre.)
61Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40 X 3mm rust free MS flat clamp @ 3 sets per metre.)
62Laying of cable as below after Cutting Floor/Pavement/Wall and making holes incl embedding the cable at an average depth as below and mending good the damages to original finish incl S+F of 1 X 10 SWG wire for ECC (Cable Dept Supply)
63From 2.5 sq mm to 35 sq mm at an average depth of 75 mm in floor/ pavement/wall etc.
64Above 35 sq mm to 95 sq mm at an average depth of 100 mm in floor/ pavement/wall etc.
65Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size Direct in Ground including excavation, sand cushioning, protective covering @ 8 bricks per metre on each cable and refilling the trench etc. as required.
66Upto 35 sq. mm
67Above 35 sq. mm and upto 95 sq. mm
68Above 95 sq. mm and upto 185 sq. mm
69Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing Masonary Open Duct incl mending good the damages to original finish. (Cable Dept Supply). This includes S+F 10 SWG GI earth wire for cables.
70Upto 35 sq mm .
71Above 35 sq. mm and upto 95 sq. mm
72Above 95 sq. mm and upto 185 sq. mm
73Supplying and making End Termination with brass compression gland and lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 kV grade as required.
742 X 10 sq mm (19 mm )
752 X 16 sq mm ( 22 mm )
764 X 16 sq mm (28 mm )
773.5 X 25 sq mm (28 mm )
783.5 X 35 sq mm (32 mm )
793.5 X 95 sq mm (45 mm )
803.5 X 150 sq mm (50 mm )
81Supply and Fixing medium gauge Gi pipe (ISI-Medium) protection for cable entry including bending the pipe to the required shape complete as required with laying of wire/cable through pipe.
8225 mm
8340 mm
84Supplying and Fixing DP/ FP Sheet Steel Enclosure on surface/recess complete with connection,testing and commissioning etc.as required without MCB/MCCB.
85Two Pole Enclosure for MCB
86Four Pole Enclosure for MCB
87Four Pole Enclosure for MCCB
88Supplying and fixing 32 Amps,415 Volt TPN Industrial type socket outlet,with 4 pole and earth (3P+N+E),metal enclosed plug top alongwith 32 Amps,\\"C\\" curve, TPN, MCB, in sheet steel enclosure,on surface or in recess with chained metal cover for the socket out let and complete with connections,testing and commissioning etc,as required.
89Supplying and fixing 63 Amps,415 Volt TPN Industrial type socket outlet,with 4 pole and earth (3P+N+E),metal enclosed plug top alongwith 63 Amps,\\"C\\" curve, TPN,MCB, in sheet steel enclosure,on surface or in recess with chained metal cover for the socket out let and complete with connections,testing and commissioning etc,as required.
90Supplying and fixing following way, Single Pole and Neutral, IP- 43, sheet steel, MCB distribution board, 240 V /415 V on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
916 Way , Double door
9212 Way Double door
93Supplying and fixing of following ways surface/ recess mounting, Horizontal type, IP-43,415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 Amps, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.
946 Way (4 + 18), Double door
95Supplying and fixing of following ways surface/ recess mounting, Vertical Type,IP-43, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 Amps, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TP DB is normally used where 3 phase outlets are required.)
968 Way (4 + 24), Double door
97Supplying and fixing double door 12 Way Vertical TPN MCB Distribution board for MCCB incomer upto 250 A with IP-42/43 protection, concealed /surface in wall after cutting the wall/on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
98Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
99Providing and fixing following rating and breaking capacity and pole MCCB with adjustable thermal and fixed magnetic setting, Ics = 100% Icu and Operational Voltage 690 V and 02 sets of terminal spreaders link in existing PCC Panel /MCCB DB/MCCB SS Enclosure including drilling holes in cubicle panel, making connections, etc. as required.
100250 Amps,36KA Four Pole
101Supplying and fixing 5 Amps to 32 Amps rating, 240/415 V,10 kA,“C” curve, Miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
102Single Pole
103Double Pole
104Triple Pole
105Triple Pole and Neutral
106Supplying and fixing 40 Amps to 63Amps rating, 240/415 V,10 kA,“C”curve, Miniature Circuit breaker suitable for inductive load of following poles in the existing MCB DB or in enclosure complete with connections, testing and commissioning etc. as required.
107Single Pole
108Double Pole
109Triple Pole
110Four Pole
111Lightning Conductor :-
112Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, GI tube, having single prong at top, with 85 mm dia 6 mm thick GI base plate including holes etc, complete as required
113Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. (Jointing shall be done by Welding with 4 inch. overlapping over the tape and anti corrosive paint on the joint / by Overlaping and with 02 sets of G.I. nut, bolt & spring washer spaced at 50 mm).
114Providing and fixing GI tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run).(Jointing shall be done by Welding with 4 inch. overlapping over the tape and anti corrosive paint on the joint / by Overlaping and with 02 sets of G.I. nut, bolt & spring washer spaced at 50 mm).
115Providing and fixing GI tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.( For Vertical run).(Jointing shall be done by Welding with 4 inch. overlapping over the tape and anti corrosive paint on the joint / by Overlaping and with 02 sets of G.I. nut, bolt & spring washer spaced at 50 mm).
116Providing and fixing testing joint, made of 20 mm X 3 mm thick GI strip,125 mm long, with 4 nos rust free GI bolts, nuts,check nuts and spring washers etc,complete as required .
117Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure of size not less than 30 cmX 30 cmX 30 cm with cast iron /MS frame with MS cover plate, 6 mm thick having locking arrangements shall be suitably embedded in the masonry enclosure and 20 mm dia Medium class GI watering pipe of 2.7 meter long etc. attached to the electrodes and a funnel with mesh on the top of this pipe for watering the earth shall be provided with charcoal/coke and salt etc. as required.
118Supplying and fixing 25X5 mm G.I strip in 40 mm dia G.I. pipe from earth electrode, including connection/terminating with G.I. nut, bolt,spring,washer and excavation with re-filling etc as required (Jointing shall be done by Welding with 4 inch. Overlapping over the tape and anti corrosive paint on the joint / by Overlaping and with 02 sets of G.I. nut, bolt & spring washer spaced at 50 mm)
119Supplying and laying 25X5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt,spring,washer etc as required.(Jointing shall be done by Welding with 4 inch. overlapping over the tape and anti corrosive paint on the joint / by Overlaping and with 02 sets of G.I. nut, bolt & spring washer spaced at 50 mm).
120Supplying and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
121Providing and fixing 25X5 mm G.I strip on Surface or in recess with fixing clamp for connections etc. as required.(Jointing shall be done by Welding with 4 inch. Overlapping over the Strip and anti corrosive paint on the joint / by Overlaping and with 02 sets of G.I. nut, bolt & spring washer spaced at 50 mm)
122Supplying & fixing earth bus of 50 mm x 5 mm copper strip on surface of wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with brass bolts, nuts, washers, spacing insulators etc. as required.
123Filling available excavated earth (excluding rock) in trenches, sides for earthing/ foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, within lead up to 50 metres including the cost of carried earth.
124Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
1252 X 16 sq. mm
1263½ X 25 sq. mm / 3½ X 35 sq. mm / 3½ X 50 sq. mm
1273½ X 70 sq. mm
1283½ X 95 sq. mm
129Supply, Installation, Testing and Commissioning of Ceiling fan with Brush Less Direct Current (BLDC) Motor with copper winding, Class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, Steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374 -2019), THD (Total Harmonic Distortion) less than 10%, Suitable for operation with electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, Ceiling Fan Complaint to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
1301200 mm sweep, Service Value (CM/Min/Watt ) minimum 6.00, Air delivery 210 CM/Min(Minimum).
131Providing and fixing M.S. fan clamp/ Highbay Light fixing clamp of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs during laying or Existing Beams of angle iron Structure, including painting the exposed portion of loop, all as per standard design complete.
132LED Highbay/Mediumbay light (System lumen efficacy ≥150 to <160 lm/Watt) :- Supplying, Installation, Testing & Commissioning ofof Ceiling (Surface/Suspended) mounted Vertical Round type Highbay/ Mediumbay Industrial PDC housing Body LED luminaire with Polycarbonate Cover including electronic driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140 - 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection & all accessories of the following Specification :- CCT >/= 5700K, Lumen >/= 10000, CRI >/= 70, P.f >/= 0.95, Efficacy(Lumen/watt) >/=150, THD < 10 %, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥150 <160 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be mitted. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Equivalent to Philips Item Model - BY515P LED100S 5700 WB PSU GR.
133LED Batten light (System lumen efficacy ≥105 to <120 lm/Watt) :- Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of Powder Coated CRCA Sheet Body (Thickness>=0.50 mm) material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140 - 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be mitted. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > = 1.20 mm)
13418 - 22 watt
13524 - 26 watt
136LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) :- Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-6,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
13736 watt
138Heavy duty Industrial applications Exhaust Fan :- Supply, Installation, Testing and Commissioning of Industrial applications 450 mm Sweep, 220 - 240 volt, a.c., 50 HZ, Single phase, metal blades with double ball bearing, powerful capacitor type durable motor, rubber mountings with metal rigid frame Heavy duty Exhaust Fan complete with all accessories of the following specification:- Power Input =/ < 350 Watts, Speed = /< 1500 RPM, Air Delivery = /> 6000 CMH, Noise label =/ < 70 db and mounting with grouted frame/clamp arrangements with necessary accessories including Supply & fixing of metal louver of suitable size.
139Making Exhaust Fan hole in wall and making good the damages and smooth cement finish etc. as practicable as possible and providing necessary length of PVC insulated wire and making connection for exhaust fan of following diameter
140Upto 60 Cm (24\\")
141Supply, Installation, Testing and Commissioning of 220 - 240 volt a.c., 50 HZ, single phase Input Voltage, 400 mm Sweep Wall Mounted Fan complete with Pull-Cord mechanism for speed control & oscillation including all accessories of the following Specification :- White in colour, Power consumption /= 80 CMM and connection with 3X1.5 sq mm FRLS PVC insulated copper conductor single core cable and earthing etc as required.
142Supply, Installation, Testing and Commissioning of 250 mm Sweep, 220 - 240 volt, a.c., 50 HZ, Single phase, Plastic Ventilating Fan complete with dust protection shutter & all accessories of the following specification :- Power Input =/ < 40 Watts, Speed = /< 1300 RPM, Air Delivery = /> 750 CMH and mounting with grouted frame/ clamp arrangements with necessary accessories & Connection with mending good to the damages.
143Dismantling of following items with good condition and shifting to site store etc. including mending good the damages to original finish etc. as required as per instructions by the EIC.
144Light Fittings/ Ceiling Fan/ Wall Fan/ Exhaust Fan/ Modular Power Board with switch & socket etc. including accessories, old wiring & cable.
145SPN DB/ Main switch/ Industrial plug & socket DB/ Metal Enclosure etc. including accessories, old cable & wiring.
146VTPN MCCB DB/ TPN MCB DB/ Small Size Power Supply Panel etc. including accessories, old cable & wiring.
147Medium Size Power Supply Panel etc. including accessories, old cable & wiring.
148Portable Fire Extinguishers :-
149Supplying, installation, testing & commissioning ISI marked ABC Powder Stored pressure type fire extinguisher containing MAP - 50% Dry powder with 4A:144B Fire Rating conforming to IS 15683:2018, Capacity : 6 KG etc. complete as required including necessary Test Certificate & Warranty Certificate.
150Supplying, installation, testing & commissioning ISI marked Carbon Dioxide(CO2) Portable type fire extinguisher with 55B Fire Rating conforming to IS : 15683:2018 , Capacity : 4.5 Kg etc. complete as required including necessary Test Certificate & Warranty Certificate. Please Enable Macros to View BoQ information

Other Detail

Information Source https://eprocure.gov.in/eprocure/app
Download FileName File Description File Size
Download a4019cb3-8476-4e99-bbd2-019edcef0ff0.html Tender Documents 0 KB
Download BOQ_953243.xls Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.