Tender Brief Tender For Supply Installation Testing and Commissioning of Air Conditioners In Construction Of 02 No. Ddc, 02 No. Medical Store And 01 In No. Emergency Trauma Ward At Chc Jakhal Dist Jhunjhunu
City Jhunjhunu
State Rajasthan
Document Fees INR 1000 /-
EMD INR 12740.0 /-
Tender Value INR 6.37 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Supply Installation Testing and Commissioning of Air Conditioners In Construction Of 02 No. Ddc, 02 No. Medical Store And 01 In No. Emergency Trauma Ward At Chc Jakhal Dist Jhunjhunu

Key Dates

Publish Date 29-04-2026
Last Date of Bid Submission 04-05-2026
Tender Opening Date 05-05-2026

Contact Information

Company Name Medical And Health Services
Contact Person Executive Engineer
Address m and h Divi Sikar

BOQ Items

Name of Work:- SITC of Air Conditioners in construction of 02 No. DDC, 02 No. Medical store and 01 in No. Emergency Trauma ward at CHC Jakhal Dist Jhunjhunu
Sl. No. Item Description
1Note: 1. The rates for the civil, sanitary Items are b PWD integrated BSR 2022 & Elect. Items are based o PWD BSR 2022 Elect. (All Raj.).2. In case of any typographical error, the relevant code for specification & BSR for rates shall be final.3. The contents of RPWA 100 shall form the essential & integral part of this G-Schedule.
2Supply , Installation, Testing and Comissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
31.5 TR ISEER not less then 3.8
42.0 TR ISEER not less then 3.8
5Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for cables. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
6Un Armoured
72 core x 2.5 Sq.mm
8Supply, installation, testing and comissioning of interconnecting copper refrigerant piping of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
912.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)
109.5 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)
116.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)
12Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
1320 mm
1425 mm
15Supply, Fixing and testing of following capacity ISO certified company made wall mounted stablizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrial plug top making connection etc complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
164 kVA
175 kVA
18Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia
1950 mm dia per running inch length
20Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Please Enable Macros to View BoQ information

Other Detail

Information Source https://eproc.rajasthan.gov.in
Download FileName File Description File Size
Download 4113481b-8946-4239-bef5-8c0d22aaa55c.html Tender Documents 0 KB
Download BOQ_988091.xls Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Download Tendernotice_2 (2).pdf Tender Documents 0 KB
Download Tendernotice_3.pdf Tender Documents 0 KB