Indian Tenders

Tender Notice

TDR 55271141
Tendering Authority North Eastern Electric Power Corporation Limited
Tender No NEEPCO/HOP/TTH/2026-27/01 Dated 28.04.2026
Tender ID 2026_NEEPC_275974_1
Tender Brief Corrigendum : Tender For Internal Electrification Of Staff Hostel No. 02 Of Tato-I/Ii/Heo Hep, Tato, Shi-Yomi District, Arunachal Pradesh.
City Shi Yomi
State Arunachal Pradesh
Document Fees Refer document
EMD INR 8222.0 /-
Tender Value INR 4.11 Lakhs /-
Tender Type Tender
Bidding Type Limitted
Competition Type Indian

Tender Details

Tender for Internal Electrification Of Staff Hostel No. 02 Of Tato-I/Ii/Heo Hep, Tato, Shi-Yomi District, Arunachal Pradesh.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 11-05-2026 Corrigendum1 Date 18-05-2026

Key Dates

Publish Date 11-05-2026
Last Date of Bid Submission 18-05-2026
Tender Opening Date 19-05-2026

Contact Information

Company Name North Eastern Electric Power Corporation Limited
Contact Person DGM Tech CNP Wing Office of the HOP
Address Office of the HOP Tato-I II and Heo HEP AP

BOQ Items

Name of Work:- Internal Electrification of Staff Hostel No. 02 of Tato-I/II/Heo HEP, Tato, Shi-Yomi District, Arunachal Pradesh.
Sl. No. Item Description
1Items
2Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as requireda). Group A
3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as requiredb). Group B
4Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as requiredc). Group C
5Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required1) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
6Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire.
7Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required3) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire.
8Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required4) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire Metre 426
9Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1) 5/6 A switch
10Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 2) 3 pin 5/6 A socket outlet
11Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3) Bell Push
12Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
13Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
14Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 1) 1 or 2 Module (75mmX75mm)
15Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 2) 3-Module (100mmX75mm)
16Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 3) 6 Module (200mmX75mm).
17Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 4) 8 Module (125mmX125mm)
18Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. (TV Point)
19Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (Power Point)
20Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
21Supplying and fixing brass batten/ angle holder including connection etc. as required.
22Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
23Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
24Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
25Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1.50.1 1) 1) 450mm sweep
26Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2) 8 way, Double door
27Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 63 A
28Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2910-Amp MCB, DHMGBSPF006-032, Havells Make
3016-Amp MCB, DHMGBSPF006-032, Havells Make
3163-Amp Kit Kat, IHKKRN4063, Havells Make
329W LED BACKUP LAMP 4H B22 CROMPTON
3320W LED LASER RAY NEO X CROMPTON
34PVC Square Box
35300MM EX-FAN EXHD300-4-1, H /DUTY CROMPTON
361200MM CF XPRESS HS AIR COCOA BROWN (H) Please Enable Macros to View BoQ information

Other Detail

Information Source https://etenders.gov.in/eprocure/app
Download FileName File Description File Size
Download 6f9cc308-4d40-49d0-b9cd-4541b53cb7a8.html Tender Documents 0 KB
Download Biddoc.pdf Tender Documents 0 KB
Download BOQ_322300.xls Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.