| 1 | Part A (Main Building) |
| 2 | Dewatering with pumps of adequate HP including Suction Delivery pipe & DG Sets, Diesel, man power etc. so as to dewater the entire site for laying foundation including plugging of inflow water complete job as per the directions of Engineer Incharge. |
| 3 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil : |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 5 | P/L of dry stone soling duly hand packed including all carriages loading unloading complete job before laying of mud mate in trenches incl. all carriages of material involved & head load. |
| 6 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 7 | Supplying and filling in plinth with Nallah boulders of (size 75mm to 150mm) under floors including, watering, ramming, consolidating and dressing including carriage of materials from approved source to site of work complete in all respects. |
| 8 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer- in - charge. Note: - Cement content considered in this item is @ 330 kg/ Cum. Excess/ less cement used as per design mix is payable/ recoverable separately. All works upto plinth level |
| 9 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer- in - charge. Note: - Cement content considered in this item is @ 330 kg/ Cum. Excess/ less cement used as per design mix is payable/ recoverable separately. All works above plinth level upto floor V level |
| 10 | Asumming quantity of cement as 450 kg for M-25 Design Mix, extra cement shall be paid seperatley as per the design requirement to achive the desised garde of concrete. |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 13 | Foundations, footings, bases of columns etc. for mass concrete. |
| 14 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 15 | Columns, pillars, piers, abutments, posts and struts. |
| 16 | Stairs (excluding landings) except spiral staircases. |
| 17 | Suspended floors, roofs, landings, balconies and access platforms. |
| 18 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 19 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto first floor level |
| 20 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:3 ( 1 cement : 3 coarse sand) |
| 21 | Extra for half Brick masonry in superstructure above plinth level upto floor V level. |
| 22 | Providing and fixing factory made uPVC white colour casement/ Casement Cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ±. 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.(Area of door upto 2.50 Sqm) |
| 23 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). |
| 24 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm upto 2.50 sqm). |
| 25 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series)frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm). |
| 26 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm &sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.) |
| 27 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand and manufacturer, in all colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of tile 600x600 mm |
| 28 | Providing and Applying of 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 fine sand) |
| 29 | Providing and Applying of 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 30 | Providing and Applying of 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 31 | Providing and applying of 2mm thick white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 32 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 33 | Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm |
| 34 | Providing and Laying of Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate. |
| 35 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 36 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In all colours, shades, except White, Ivory, Fume Red Brown |
| 37 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) For fixed portion Anodized aluminum (Anodized transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15) |
| 38 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side. |
| 39 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including Newel Post. |
| 40 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 41 | Structural steel work (Welded ) in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 42 | Providing and fixing with High rib profile sheet roofing including vertical/curved surface including polymer coated J. or L hooks, fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface) excluding the cost of purlins, rafters. (0.50mm thick) including ridges, hips, valleys, Eaves boardings, soffits and carriage of materials upto site of work complete as per the directions of Incharge Engineer. |
| 43 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 44 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour or shade (Area of slab over 0.5 sqm) |
| 45 | Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite Work |
| 46 | Extra for fixing marble / granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. |
| 47 | Providing and fixing of 2D wall Panelling of 12mm thick HDHMR board placed over 12mm thick ply board base, including the cost of 2 layer Duco paint high glossy/ mate finish over the base of Duco putty and surfacer, including the cost of labour, carriage and all necessary fittings/ fixtures complete job in all respects as per the directions of Incharge Engineer. |
| 48 | Providing and fixing of KHATAM BANDI ceiling of first class budloo/fir wood including the cost of frame work in KD wood joist of 50x50mm and 450x450mm mesh apart as per site requirement and 10mm plyboard and french spirit polishing, two or more coats on new work incl the cost of wood filler, Paanch Murabah complete job in all respects as per the directions of Incharge Engineer. |
| 49 | Providing, fixing and applying Plaster of Paris (POP) false ceiling consisting of frame work made with 50mm sq M.S. tubes of 18 G thickness as main runner at 600 mm c/c both ways, suspended/ supported with M.S. flats 25x4 mm from existing R.C.C. slab, finished smooth to line and level including necessary supports, scaffolding etc. as required and also including applying a coat of red oxide zinc chromate primer over the M.S. frame work and suspenders complete. 12.47.1 Including providing and fixing expanded metal of size 5.25 mm x 1.25 mm thickness welded to main runners and applying POP (calcium sulphate semi hydrate variety) to the expanded metal of thickness not less than 10 mm |
| 50 | Providing and fixing of 3D Wall pape-fabric type, Wall paper of standard quality including cost of necessary glue, adhesives and other fittings/ fixtures complete in all respects. (Design to be approved by Incharge Engieer). |
| 51 | Providing 75mm wide POP cornice on the ceiling as per the directions of Incharge Engineer. |
| 52 | Supplying and Fixing of Rolling blinds of Zebra blinds of Standard quality and make 100mm wide of required colour and shade including necessary fittings/ fixtures, nails and screws, associated channels etc complete job (Design and colour to be approved by EIC). |
| 53 | Providing and fixing of 19mm thick plyboards for making of Almirah/ Cabinets/ boxes (600mm deep) including cost of mica, lining and making shelf below the counter / cupboards, necessary nails, screws, fittings/ fixtures including applying of primer etc all complete as per the directions of Incharge. |
| 54 | Carriage of materials from approved source to site of work complete:- |
| 55 | Stone Aggregate for an avergae lead of 20Kms |
| 56 | Sand for an average lead of 20Kms |
| 57 | Bricks for an average lead of 70Kms. |
| 58 | Part B (Sanitary) |
| 59 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid. |
| 60 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 61 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps. |
| 62 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 63 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm |
| 64 | Providing and fixing toilet paper holder C.P. brass |
| 65 | Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms. |
| 66 | Providing and fixing health faucet with hose pipe for european water closet complete in all respect of approved quality (hindware) |
| 67 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face withconcealed fittings arrangements of approved quality and colour, weighing not less than 88 gms. |
| 68 | Providing and fixing brass bib cock of approved quality. 15 mm nominal bore |
| 69 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 70 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore |
| 71 | Providing and fixing uplasticized PVC connection pipe with brass unions 45 cm length 15 mm nominal bore |
| 72 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 73 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. |
| 74 | 15mm nominal outer dia pipes. |
| 75 | 20mm nominal outer dia pipes. |
| 76 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. |
| 77 | 25mm nominal outer dia pipes. |
| 78 | 40mm nominal outer dia pipes. |
| 79 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. External work including trenching, refilling etc. |
| 80 | 40mm nominal outer dia pipes. |
| 81 | 50mm nominal outer dia pipes. |
| 82 | Providing/ Supplying/ Installation/ Testing and Commissioning of Centrifugal monoset self priming pump 1.5KW/ 2HP (Crompton) including all fittings / fixtures complete as per the directions of Incharge Engineer. |
| 83 | Providing/ Supplying/ Installation/ Testing and Commissioning Pressure Pump with danfoss switch Kirloskar Brothers JALRAAJ-I ULTRA 1 HP including all fittings / fixtures complete as per the directions of Incharge Engineer. |
| 84 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 85 | Providing and fixing of 50 Ltr water heater geyser of approved brand and make (Jaquar/ Hindware/ Recold or equivalent brand ) including placing in position and other necessary fittings/ fixtures, nails and screws complete as per the directions of Incharge Engineer. |
| 86 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040mm bowl depth 250mm |
| 87 | Providing and fixing of Wash Basin Mixer ( Jacquar/ Hindware or equivalent brand) of approved brand and make. |
| 88 | Providing and fixing of Sink Basin Mixer ( Jacquar/ Hindware or equivalent brand) of approved brand and make. |
| 89 | Part C (Drainage) |
| 90 | Providing, Fixing, Testing & Commissioning uPVC SWR pipes (Type-B) for soil, waste and vent conforming to IS 13592 along with all required fittings like tees, bends, cowls, crosses with or without access doors jointed with approved solvent cement fixed to walls and ceilings including angle supports with clamps complete including cutting holes in R.C.C/brick work (slab/beam/wall) and making good the floors, beams and walls with cement mortar where required complete of outer diameter.(Soil/ Waste pipe) (PRINCE ISI MARK) |
| 91 | 110 mm dia |
| 92 | 150 mm dia |
| 93 | 75 mm dia |
| 94 | 50 mm dia |
| 95 | 40 mm dia |
| 96 | Excavating trenches of required width for pipes, cables etc including excavation for sockets, and dressing of sides, ramming of bottom, depth up 1.5m including getting out the excuated soil and the returning the soil as required in the trenches complete as per the directions of Incharge Engineer. |
| 97 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 98 | Providing and fixing 15cm wide 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete. 0.80 mm thick with zinc coating not less than 275 gram/m2 |
| 99 | Constructing brick masonry manhole in cement mortar 1:2:4 cement mortar including internal plastering and 50mm thick Cement Concrete flooring, MS Manhole covers complete job as per the directions of Incharge Engineer. (Size 600x 600x600mm) |
| 100 | Part D (Septic Tank / Soakage Pit) |
| 101 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 Sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil |
| 102 | P/L of dry stone soling duly hand packed including all carriages loading unloading complete job before laying of mud mate in trenches incl. all carriages of material involved & head load. |
| 103 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 104 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 105 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 106 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete. |
| 107 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 108 | Providing and Applying of 12mm Cement plaster finished with a floating coat of neat cement of mix: 1 : 4 ( 1 cement : 4 fine sand) including curing complete. |
| 109 | Dry random rubble masonry with hard stone in foundation and plinth: Quarry stone with bond stone |
| 110 | Providing and Laying of Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate. |
| 111 | Carriage of materials from approved source to site of work complete:- |
| 112 | Stone Aggregate for an avergae lead of 20Kms |
| 113 | Sand for an average lead of 20Kms |
| 114 | Stones for an average lead of 20Kms |
| 115 | Bricks for an average lead of 70Kms. |
| 116 | Shifting of Utilities |
| 117 | Shifting of 2 no electric HT Poles including Dismantling, Relocation, Transportation & handling, Re-erection and Installation of HT Poles, Stringing and Assembly at New site including conductors, insulators and other hardware items complete and Testing and Handover to the intending department. |
| 118 | Electrification |
| 119 | Wiring for Light point/Exhaust point with (P+N+E) 3x1.5 sq.mm FRLS-H/HFFR PVC insulated Multi strand Copper conductor single core cable (Polycab/Finolex/Anchor/Salzer/Havells Make) in existing surface/recessed Conduits (Including Cost of Conduit) laid in slabs with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified Havells(Crab-Tree)/Legrand(Myris)/Anchor Rooma Plus/Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work. |
| 120 | Supplying and Fixing of Indicator as required, ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work. |
| 121 | Wiring for Fan point with (P+N+E) 3x1.5 sq.mm FRLS-H/HFFR PVC insulated Multi strand Copper conductor single core cable (Polycab/Finolex/Salzer/Anchor/Havells Make) in existing surface/recessed Conduits (Including Cost of Conduit) laid in slabs with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work. |
| 122 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required,ISO/IEC Certified of Legrand(Myris)/ Anchor Rooma Plus/Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work. |
| 123 | Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H/HFFR PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Polycab/Finolex/Anchor/Salzer/Havells Make) |
| 124 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work.(Including Inverter Input/Output) |
| 125 | Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H/HFFR PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Polycab/Finolex/Salzer/Paraflex Make) |
| 126 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work. |
| 127 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS-H/HFFR PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Polycab/Anchor/Finolex/Salzer/Havells Make) & shall be approved before execution of work. |
| 128 | 2x10 sq.mm+ 1x6 sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards. |
| 129 | 2x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting/Inverter/AC Point Sub main in One run from Main Panel to Distribution Boards. |
| 130 | 2x2.5 sq.mm+ 1x2.5 sq.mm (P+N+E) for Lighting/Inverter Circuit in One run from switch boards to Distribution Boards. |
| 131 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required of Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/Equivalent Make |
| 132 | Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections.(L&T/Siemens/Legrand/ABB /Schneider Make) |
| 133 | Supply/Fixing/Testing and Commissioning of Supplying and fixing following rating, double pole,(single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (L&T/Siemens /Legrand/ABB/Schneider Make) |
| 134 | 25-32Amp. |
| 135 | 40Amp. |
| 136 | 63Amp. |
| 137 | Supplying and Fixing of MCB 12-way horizontal typed , sheet steel, Double Door Distribution Board, SPN 240V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ ABB /Schneider Make) |
| 138 | Supplying and Fixing of MCB 8-Way (4+24) horizontal typed , sheet steel, Double Door Distribution Board, TPN 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ ABB /Schneider Make) |
| 139 | ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER ROD EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value.Supply,Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 20mm Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through suitable DWC High Density Poly ethylene Pipe having Corrugation complete job. |
| 140 | Supply/Installation/Testing and Commissioning of 18W + LED Surface/Recess Mounted Panel light luminary fitting round shape with minimum system lumen efficacy of 120 lm/W with Pressure Die cast Aluminium body & Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Wipro/Bajaj/Jaquar/LT/Crompton/Surya/Equivalent Make. |
| 141 | Supply/Installation/Testing and Commissioning of 22-24 watt ultra slim LED surface mounted lighting panels(300mm x 300mm) having CRCA Body (Commercial type), minimum lumens 100 lm/w ,the luminaire housing should be crca /aluminium and the luminair optics shall have a high efficency with transmittance ,average life of 50000 hrs operating temperature -10 C to + 45 C. The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Wipro/Jaquar/Bajaj/Surya/Equivalent Make |
| 142 | Supply/Installation/Testing and Commissioning of 36-40 watt ultra slim LED surface mounted lighting panels (600 mm x 600mm Square) having CRCA Body (Commercial type) ,minimum lumens 100 lm/w ,the luminaire housing should be crca /aluminium and the luminair optics shall have a high efficency with transmittance ,average life of 50000 hrs operating temperature -10 C to + 45 C.The Fixture should have In-built Surge Protection of 2kV,440V Protection.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Wipro/Jaquar/Bajaj/Surya/Equivalent Make |
| 143 | Providing & Fixing of IK08 IP-66 protected high power LED 100 Watt flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 Im/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 Im of Bajaj/Jaquar/LT/Crompton/Surya/Equivalent Make. as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department. |
| 144 | Supply/Installation/Testing and Commissioning of BLDC 1200 mm sweep, ceiling fan with 03 No. blades, 30 cm long down rod, 02 No. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Havells/Polycab/Orient Make.(5-Star) |
| 145 | Supply/Installation/Testing and Commissioning of upto 400mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB o including connection etc USHA/Anchor/Polycab/Orient Make. |
| 146 | Supply/Installation/Testing and Commissioning of ABC type Fire Extinguisher 4.Kg. Capacity ISI Mark(IS:15683) and dully certified. |
| 147 | Supply/Installation/Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683)suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G,acetylene and electrical fires. |
| 148 | Supply/Laying of 25/32mm Dia PVC Conduit of Anchor/Ravinder/Polypack/Finolex Make with other accessories like bends,etc complete. |
| 149 | Supply and Fixing of single pole blanking plates on existing MCB boxes, excluding cost of Boxes. |
| 150 | Providing and fixing of bakelite hylam sheets of required size including cutting, filing with S/F screws etc. |
| 151 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required of Legrand/Panasonic/Anchor/Schneider/Equivalent Make |
| 152 | Supply/installation/testing and commissioning of CPRI-approved panel Wall/floor-mounted compartmentalized, 415 volts TPN MCCB Main Distribution panels, fabricated out of sheet steel of 16 gauge dust-protected, painted incl earth terminal with all necessary accessories as required for panel with internal wiring of panel.The Panel is to be provided and fitted with the following adjustable-type controlling/protection switchgear devices:1. Normal Incoming:200 Amp TPN MCCB with breaking capacity of 36 KA with extended thimbles of Legrand/Siemens/ABB//LK make = 1 No.,200 Amp Bus bar Al Strips(3+1) = 1 Set,Digital Voltmeter =1 No., Digital Ammeter = 1 No., CT coils for Ammeter 300 / 5A = 1 set, phase indicators =1 set2. Generator Incomer:100 Amp Four Pole Change over Switch of Legrand/Siemens/ABB//LK make = 1 No., 200 Amp Bus bar Al Strips(3+1) = 1 Set, Digital Voltmeter =1 No., Digital Ammeter = 1 No., CT coils for Ammeter 300 / 5A = 1 set, phase indicators =1 set3. Bypass Switch:100 Amp 4-Pole Bypass Switch for bypassing 15 KVA AVROutgoing:(1) 63 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 08 No for normal heating sub main(2) 40 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 08 No for Sub main lighting(3) 32 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 08 No for Sub main invertorThe Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards) is to be approved by Engineer Incharge before manufacturing. |
| 153 | Supply/Installation/Testing & Commissioning of 1-phase 15 KVA,50 Hz Oil cooled unbalanced type Voltage Stabilizer SERVO control of Approved brand COPPER wound of AE/Chinar/Cosco Make ISI/1SO/IEC certified for smooth functioning/constant voltage supply having Technical Specifications :Input voltage(Ph-Ph) ranging from 90 Volts to 240 Volts and a balanced output Voltage of 230 Volts, ±2% Buck Boost Transformer Copper wound 99.9% ,OIL Immersed COOLING OIL, High cut/Low Cut /Time delay/Over Cut through Micro Controller and Spike Protection. |
| 154 | Providing and Laying of shock proof rubber mats of 2mx1mx12mm thick in size of Standard Make. |
| 155 | Supply/Laying/Testing and Commissioning of 3.5- Core 50 mm sq. Al armored XLPE Insulated,PVC cable Havells/Polycab/RR Kabel/Paramount/KEI Make. Including Supply/Laying of HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation where required and refilling the trench of standard make as approved.The cable shall include end termination lugs with its crimping /taping. Please Enable Macros to View BoQ information |