| 1 | SUB-HEAD-I : D.G. SET |
| 2 | 58.5 KVA CPCB-IV silent cummins D.G. Set with Cummins Engine Model X3.6-G3 series, 4 cylinder, In-line 4 stroke, radiator cooled engine. Water cooled turbochared air cooled,developing 206 BHP at 1500 RPM under NTP conditions of BS: 5514. The engine shall be provided with electric starting arragement and shall give the electric output of 58.5 KVA/46.8 KW at 0.8 power factor, 415 Volts at the alternator terminal with 58.5 KVA AMF panel with 2 years warranty on Engine & Alternator from the date of dispatch against any manufacturing defect/defective materials only and 5 Years warranty on 5 Critical Parts of Engine (Cylinder Head, Cylinder Block, Camshaft, Crankshaft, Connecting rod) from the date of dispatch against manufacturing defect. |
| 3 | DIESEL ENGINE : - ECO-FRIENDLY (CPCB norms compliance ). |
| 4 | COOLING SYSTEM - Radiator cooled, Engine mounted Water pump, Thermostats, Coolant, Self-contained piping. |
| 5 | FUEL SYSTEM - High pressure common rail fuel system, Spin on type Fuel filters, Self contained piping. |
| 6 | LUBRICATING SYSTEM - Lub Oil pump, Spin on type lub oil filter ,Self contained piping |
| 7 | AIR IN TAKE SYSTEM - Dry type replaceable paper element air filter, Air intake manifold with necessary connections, Turbo charger. |
| 8 | EXHAUST SYSTEM - Exhaust manifold, Flexible piping, Silencer – Hospital Grade. |
| 9 | GOVERNING SYSTEM - PC 1.2 controller |
| 10 | STARTING SYSTEM - Starter, 12V, DC, Battery charging Alternator, With in-built Regulator . |
| 11 | OTHER SYSTEM - Flywheel, Flywheel housing. |
| 12 | GENSET CONTROLLER - |
| 13 | Basic stand-alone Genset control system- Feature laden modular Genset control system- Part of our modular and interchangeable control product line PMG compatibility and extra inputs and communication capability (ModBus & CAN), are the major advantages.Features:- Digital Full Wave SCR AVR for shunt - Digital Electronic Governing with temperature compensation and Smart Starting- SAE J1939 Interface to Full Authority Electronic (FAE) engines.- Engine Metering: Oil Pressure, Coolant Temperature, Battery Voltage, Engine Speed- AC Alternator Metering: L-L Voltage and N voltage (phase and average), Current (phase and total), Volt-Amperes (phase and total), and Frequency- Engine Protection: Low Lube Oil Pressure, High Coolant Temperature, Over speed, DC Over/Under/Weak Volts, Fail to Crank/Start, Sensor Failure- AC Alternator Protection: Over/Under Voltage, Over/Under Frequency, Over Current, Short Circuit, and Loss of AC Sensing- Fault Codes and Description on HMI- Data Logging: Engine Hours, Control Hours, Engine Starts and 10 Fault Codes- Control Set-Up without PC-based tool (InPower)- Battle Short fault bypass function- Configurable Cycle Cranking- 12 and 24 Volt DC Operation- Easy Wiring connectors for factory connections, terminal blocks for field connections- Configurable Time Delay Start/Stop- Sleep Mode Low power in Off and/or Auto -Programmable I/O(2 inputs and 2 outputs) expandable with AUX101/102 modules |
| 14 | Alternator :- |
| 15 | Manufacturer : M/s Cummins Generator Technologies (Stamford)Power Rating kVA / kWe : 160/128Power factor : 0.8Rated Generating Voltage : 415 VoltsVoltage regulation : +/- 1% all load between no load to full load & factor0.8 to unity.Frequency : 50 HzSpeed : 1500 RPMClass of insulation : HWinding connection : Star connection (all six leads will be brought out of stator frame).Overload capacity : 10% for one hour in any 12 hours of operation without exceeding temperature rise limits specified in BS:2613 or BS:5000 when corrected to ambient temperature at site.Bearings : Long life single bearingEnclosures : Drip proof & screen protected IP-23The alternator shall be of self-excited, self regulated, self ventilated in brushless design, provided with suitable automatic voltage regulator and shall conform to BS:2613 or BS : 5000 and shall give rated output at NTP conditions. |
| 16 | CONTROL PANEL FOR DG SET : |
| 17 | The Generator control shall be indoor type, floor mounted, dust and vermin proof in sheet steel construction. The panel shall have doors at the front and back for proper maintenance. The panel shall have steel channel fabricated kick-plate and bolted type cable gland plate fitted at the bottom. The panel shall be constructed from 2 mm thick steel sheet. All the joints shall have proper gaskets.Monitoring and control devices shall be housed on the front door. Generally the construction of the panel will be such that various equipment’s for applications will be housed in compartments. All incoming and outgoing power and control cables shall be from the bottom. |
| 18 | The panel will be equipped as follows :- |
| 19 | Incomer - 1 no. 3 pole, 500Amp MCCB, Set of CTs for metering. |
| 20 | Instrument :- 1-Voltmeter with selector switch, 1- Ammeter with selector switch, 1- Frequency meter, 1- KWH meter, 1- KW meter |
| 21 | Indication Lamps :- Genset Running, Set on Load, Phase Indication. |
| 22 | SOUND ATTENUATED SYSTEM |
| 23 | Thickness of sheet - 16 - G |
| 24 | High class sheet metal fabricated enclosure for reducing the noise level of DG set & also acts as a weather proof housing. Genset will be a integral part of acoustic enclosure and whole construction will be on multi-fold sheet channels & ISMC sections. Enclosure construction is fully bolted keeping in view the major service requirements all doors are provided with specially designed hinges and lockable handles, Battery, Fuel tank is housed inside the enclosure. |
| 25 | ACCOUSTIC MATERIALS :- |
| 26 | Specially designed to meet stringent MoEF/CPCB norms of 75 dBA @ 1mtr at 75% load under free field conditions. |
| 27 | High quality noise absorbent and fire-retardant grade acoustic insulation material (Foam) complying to IS 8183. |
| 28 | VENTILATION |
| 29 | Acoustic enclosure is designed in such a way that there are no hot pockets around engine and it is provided with suitable designed engine radiator which does not allow the temperature to rise more than 70C above ambient temperature.To achieve optimal output and minimum sound level from the DG set, suitable openings are provide for increasing the inflow of air required for combustion & forced ventilation. Air intake system as per the recommendations and engine requirement are provided. |
| 30 | The sound control system designed to suppress the sound level to 75 db maximum at 1 mtr. distance in open free field environment as per ISO 8528 part 10. |
| 31 | SILENCER |
| 32 | Specially designed low noise silencer is provided. Silencer & engine exhaust outlet, Connected with flexible SS below. |
| 33 | VIBRATION ISOLATION:- |
| 34 | To avoid transfer of vibration from genset to enclosure & surrounding specially designed vibration isolators are used. |
| 35 | Complete rate of DG Set including, Price of DG set, Price of AMF Panel, Installation chargers Cable connection etc. completes in all respects: - Make:- Sudhir/Kirloskar/Ashok Leyland/TATA. |
| 36 | Providing/filling Diesel in the existing Diesel Set of Generator as required complete in all respect. |
| 37 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. |
| 38 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand) : 4 gradedstone aggregate 20 mm nominal size) |
| 39 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size) |
| 40 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. |
| 41 | SUB-HEAD-II :- EARTHING & LOOP EARTHING |
| 42 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 43 | Providing and fixing 25mm x 5mm copper strip on surface or in recess for earth connections etc. as required. |
| 44 | SUB-HEAD-III :- WIRING & CABLE LAYING |
| 45 | Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as require (Make:- KEI/ Plaza/Havells) |
| 46 | Armoured cable 35 sq. mm (3.5 core) |
| 47 | Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-(Make:- KEI/ Plaza/Havells) |
| 48 | Armoured cable 35 sq. mm (3.5 core) |
| 49 | Providing & laying of One No. Aluminium conductor, PVC insulated and PVC sheathed armoured/XLPE power cable, working voltage 1100 volts grade direct in ground to be laid 1 Meter below the ground level i/c excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering. (Make:- KEI/ Plaza/Havells) |
| 50 | Armoured Cable 2.5 sqmm 6 core |
| 51 | Providing & laying of One No. Aluminium conductor, PVC insulated and PVC sheathed armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size. (Make:- KEI/ Plaza/Havells) |
| 52 | Armoured Cable 2.5 sqmm 6 core |
| 53 | Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 54 | 100 A- 125 A 18 KA 4 Pole (Make:- L&T/ Legrand/Schneider) |
| 55 | Providing and fixing Enclosure for MCCBs suitable for 3Pole & 4Pole MCCBs etc. as required. Make: L&T/ Legrand/ Schneider. |
| 56 | Enclosure for MCCB Size I |
| 57 | Providing and fixing following rating, four pole, 415 volts, On-Load change over switch unit, in sheet steel enclosure, with side handle operation, including drilling holes on the board, making connections, etc. as required. |
| 58 | 125 A. TPN, On Load Change over switch (Sheet steel enclosure type) (Make:- L&T/ Legrand/Schneider) Please Enable Macros to View BoQ information |