Indian Tenders

Tender Notice

TDR 55248712
Tendering Authority Public Works Department
Tender No 22/EE(E)/JED-1/PWD/2026-27
Tender ID 2026_PWD_290433_1
Tender Brief Corrigendum : Tender For repair maintenance E&M Services Installed At Karkardooma Court Complex, Delhi. (Sh:- Servicing Overhauling And Comprehensive Maintenance Of Various Type Air Conditioners And Water Coolers)
City Delhi
State Delhi
Document Fees Refer document
EMD INR 53352.0 /-
Tender Value INR 26.67 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for repair maintenance E&M Services Installed At Karkardooma Court Complex, Delhi. (Sh:- Servicing Overhauling And Comprehensive Maintenance Of Various Type Air Conditioners And Water Coolers)

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 05-05-2026 Corrigendum Date 07-05-2026

Key Dates

Publish Date 05-05-2026
Last Date of Bid Submission 07-05-2026
Tender Opening Date 07-05-2026

Contact Information

Company Name Public Works Department
Contact Person Executive Engineer(E)
Address Judiciary Electrical Division-I, PWD, Yamuna Western Bank, Lok Nayak Setu, New Delhi-110002

BOQ Items

Name of Work:- RMO E&M Services installed at Karkardooma Court Complex, Delhi. (SH:- Servicing overhauling and Comprehensive maintenance of various type Air Conditioners and Water Coolers)
Sl. No. Item Description
1Comprehensive running maintenance and servicing of various WTAC/STAC/ Tower AC/ Cassette type Air Conditioners and water coolers of (1.0/1.5/2.0 TR) of different makes and models installed at Karkardooma Court Complex including labour charge and replacement of all defective minor parts, i/c supplying and charging of R-410/R-22/R-32 refrigerant gas in the compressor in case of leakage (Except replacement of compressor) i/c checking the units oiling, greasing, chemical cleaning of condenser coil, cooling coil i/c replacement of defective parts, Air filter, running capacitor, starting capacitor, starting relay, overload relay thermostat switch, wiring kit, 15/20 Amp plug top/Industrial socket, flexible connection cable/ lead, drain pipe, water cooler drip tray, tap, float valve etc. and tightening the loose connection, complete as required.
2Air Conditioners and water coolers for summer Season 590 Nos. for 8 Months {with minimum staff (2 Nos. Technician & 2 Nos. Helper in 9 AM to 5 PM and1 Nos. Technician and 1 Nos. Helper in 12 Noon to 8 PM)
3Dismantling and reinstallation of existing 1.5/2.0 TR STAC units including removing copper pipe connection, drain pipe i/c disconnection from electrical mains & repairing of wall with cement/POP etc. and then fixing the ac unit at the desired location as per directions of Engineer in charge.
4Supplying and replacement of compressors of following capacities in the split type AC units/WTAC units/ Water Coolers i/c charging the gas, piping (upto 2 mtr) etc complete as required.
51.0 T.R. capacity
61.5 T.R. capacity
72.0 T.R. capacity
8Cooling Coil for 1.5/2.0 TR capacity AC
9Condenser Coil for 1.5/2.0 TR capacity AC
10PCB remote hand set
11PCB kit for 1.5/2.0 TR capacity AC
12Blower indoor unit
13Cooling Coil for 3.0/3.5 TR Tower AC
14Condenser Coil for 3.0/3.5 TR Tower AC
15Providing, Replacement & Laying of refrigerant copper piping (5/8\\" & 3/8\\" dia) alongwith black rubber AC insulation pipe from indoor unit to outdoor unit of split type AC duly insulated along with 2.5 sq.mm 4 core PVC insulated PVC sheathed flexible copper conductor cable and 20mm size of cotton thread ribbed PVC flexible pipe from drip tray of AC units to drain pipe i/c gas charging of suitable refrigerant etc. as reqd
16Supplying, Installation, testing and commissioning of 1.5/2.0 Tr Capacity Indoor AC unit , Copper Refrigerant , Compatible with all Eco Friendly Refrigerant gas capable for Cooling , dehumidifying , air circulating suitable for operation on 230V 50Hz Single Phase AC Supply etc including connection with outdoor AC Unit etc complete as reqd and as per directions of Engineer in charge Including credit for old dismantle Indoor Unit.
17Supplying, Installation, testing and commissioning of 1.5/2.0 Tr Capacity Outdoor Unit STAC of following Capacity suitable for operation on 230V , 50Hz Single phase AC Supply , Capable of performing cooling , complete with condenser coil , compressor , valve set fitting i/c credit of dismantle material etc complete as reqd.
18Comprehensive running maintenance and servicing of 30 Nos. desert/air coolers of various makes and models installed at Karkardooma Court Complex, including attending routine as well as breakdown maintenance, periodic inspection, thorough cleaning of water tank, cooling pads, and air passages, lubrication of motor and fan assembly, checking, testing and maintenance of electrical components such as wiring, switches, capacitor, plug top, and ensuring proper functioning of the equipment. The work shall include tightening of all electrical connections, replacement of worn-out and defective components such as honeycomb cooling pads / jali, capacitor, switches, internal wiring, fan blade, 5/15 amp plug top, flexible connection cable/lead, submersible pump for air cooler, front grill, and other associated minor components, complete as required.
19Less credit of buy back of following dismantled material:
20Assorted Compressor
21Assorted indoor unit
22Assorted outdoor unit
23Condenser Coil/ Cooling Coil
24PCB kit
25Blower indoor unit Please Enable Macros to View BoQ information

Other Detail

Information Source https://govtprocurement.delhi.gov.in
Download FileName File Description File Size
Download a8eb4738-7d65-495f-91a5-6d0ed136a666.html Tender Documents 0 KB
Download BOQ_385474.xls Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.