Tendering Authority Military Engineer Services
Tender No GE/U-38/2026-27
Tender ID 2026_MES_762044_1
Tender Brief Corrigendum : Tender For Repair/Replacement Of Dg Sets Of Northern Part Under Ge Utilities Udh Ur
City Reasi
State Jammu And Kashmir
Document Fees INR 500 /-
EMD INR 99980.0 /-
Tender Value INR 49.99 Lakhs /-
Tender Type Works
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender For Repair/Replacement Of Dg Sets Of Northern Part Under Ge Utilities Udh Ur

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 11-05-2026 DATE Date 21-05-2026

Key Dates

Publish Date 11-05-2026
Last Date of Bid Submission 21-05-2026
Tender Opening Date 23-05-2026

Contact Information

Company Name Military Engineer Services
Contact Person GE (Utilities) Udhampur
Address GE (Utilities) Udhampur, PO-Garhi, Pin-182121

BOQ Items

Name of Work:- Repair/Replacement of DG sets of Northern Part under GE Utilities Udh ur
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE Utilities Udhampur Name of Work: Repair/Replacement of DG sets of Northern Part under GE Utilities Udhampur Contract No: GE/U-38/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words
2Carry out servicing from authorised rep or service engineer from the manufacturer of DG set of 320 KVA,capacity all as per OEM instructions and directed by Engineer in Charge .Note : All the spare , parts , lubrication oil etc. has been measured and paid saperatly under respective item of schedule.
3Description all as per item No.1.00 here in before but for 250 KVA DG set
4Description all as per item No.1.00 here in before but for 200 KVA DG set Make: Cummins complete all as specified
5Description all as per item No.1.00 here in before but for 125 KVA DG set Make: Cummins complete all as specified
6Description all as per item No.1.00 here in before but for 100 KVA DG set Make: Kirloskar complete all as specified
7Description all as per item No.1.00 here in before but for 62.5 KVA DG set
8Description all as per item No.1.00 here in before but for 40 KVA DG set
9Description all as per item No.1.00 here in before but for 30 KVA DG set
10Description all as per item No.1.00 here in before but for 15 KVA DG set
11Description all as per item No.1.00 here in before but for 10 KVA DG set
12Fuel filter primary and secondary suitable for DG Set capacity 200KVA to 320KVA.
13Supply only lub oil filter body suitable for DG Set capacity 200KVA to 320KVA.
14Supply only Air cleaner element suitable DG Set for capacity 10KVA to 320KVA.
15Inner Air cleaner element suitable DG Set for capacity 10KVA to 320KVA.
16Supply only water filter body suitable for DG Set capacity Upto 10KVA to 320KVA.
17Supply only fuel filter primary and secondary suitable for DG Set capacity Upto 125 kva
18Supply only lub oil filter body suitable for DG Set capacity Upto 125 kva.
19Supply only Air cleaner element suitable DG Set for capacity Upto 125 kvaCat Part No. 04.586.01000 of make kirloskar or equivalent Bosch
20Supply and filling coolent for radiators. K Cool super Plus -50-50 premix.
21M&L for replacement of Solenoied switch sutaible for 15 KVA to 40 KVA DG Set complete All as specified & directed by engr-in-charge
22M&L for replacement of Solenoied switch sutaible for 62.5 KV to 125 KVA DG Set complete All as specified & directed by engr-in-charge
23M&L for replacement of Solenoied switch sutaible for 200 KVA to 250 KVA DG Set complete All as specified & directed by engr-in-charge
24M&L for replacement of water circulating pump, for DG set of capacity 200 KVA to 320 KVA including air supply connection pipe, clip, replacement of repair kit, calibration/ testing system complete, fitted with DG set properly in original position, checking the allignment, making proper all connection, testing for smooth opreation from authorised rep or service engineer from the manufacturer complete all as directed.
25Material & labour for complete control wiring for connect all safety to controller/ AMF panel of 250 kva DG set & 320 KVA DG set carrying out complete servicing control panel, including checking and rewiring electrical circuit using FRLS copper conductor, for DG Set of any type / make / capacity, making all electric connections and testing for smooth operation, complete All as specified & directed by engr-in-charge
26M&L for replacement of low level water safety relay for DG set of capacity upto 320 KVA of any make complete All as specified & directed by engr-in-charge
27M&L for replacement of over heat safety relay for DG set of capacity upto 320 KVA of any make complete All as specified & directed by engr-in-charge
28M&L for replacement of Solenoied switch sutaible for 320 KVA DG Set complete All as specified & directed by engr-in-charge
29M&L for replacement of Ring gear of Flywheel suitable for DG set up to 320 kva complete All as specified & directed by engr-in-charge
30Supply and fixing in replacement of AVR S/F VARIABLE SPEED DCDG suitable for DG set with input voltage range 415 Volt AC with neutral & Out put DC voltage suitable for DG set upto 100 KVA complete all as specified and directed by Engineer -in-charge.
31Supply and fixing in replacement of AVR S/F VARIABLE SPEED DCDG suitable for DG set with input voltage range 415 Volt AC with neutral & Out put DC voltage suitable for DG set above 125 KVA to 320 KVA complete all as specified and directed by Engineer -in-charge.
32Supply, Fix & test run the DG set after replacing Diesel feeder Pump of existing model,size suitable for DG Set of capacity 15 to 100 KVA including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge.
33Supply, Fix & test run the DG set after replacing Diesel feeder Pump of existing model,size suitable for DG Set of capacity 200 to 320 KVA including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge.
34Drain out the fuel from the fuel tank of DG set of any size/capacity and keeping it in separate container safely, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt/ sediment, leak testing the tank and welding/ brazing including one coat of synthetic enamel paint, refixing the tank in its original position, replacing the drain plug and PVC pipe, calibrating the fuel tank, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements, complete all as specified and directed by Engr-in-Charge.
35Disconnected and opening of self starter assemlly 12 volt for repair from DG set upto 125 KVA, repair unserveceable part of self starter suitable size as required on site complete all as specified and directed.Note :- Rate are deemed tobe include all worn out part including gear & winding, complete all as specified and directed by Engr-in-Charge.
36Disconnected and opening of self starter assemlly 24 volt for repair from DG set 250 kva & 320 KVA, repair unserveceable part of self starter suitable size as required on site complete all as specified and directed.Note :- Rate are deemed tobe include all worn out part including gear & winding , complete all as specified and directed by Engr-in-Charge.
37Supply & fix the following items of DG Set of various capacity :-
38Battery terminal(copper), lug, bolts type suitable for heavy duty battery.
39Battery leads for copper conductor multiwired 50 Sqmm Single Core.
40Hinges for DG set door of any size, any type as required on site.
41Supply and topping up of distilled water suitable for lead acid batteries of 12 volts, complete all as specified directed by Engr-in-Charge.
42M&L for replacement of Lub oil pipe suitable DG Set for capacity 15KVA to 320KVA , complete all as specified and directed by Engr-in-Charge.
43M&L for replacement of tappet valve suitable DG Set for capacity 15KVA to 320 KVA , complete all as specified and directed by Engr-in-Charge.
44M&L for replacement of Fuel Pipe for filter (7.5,14x14B,700PB) for BIO Diesel suitable DG Set for capacity 15KVA to 320KVA , complete all as specified and directed by Engr-in-Charge.
45M&L for replacement of Fuel Pipe return ( FIP TO TANK) for BIO Diesel suitable DG Set for capacity 15KVA to 320KVA , complete all as specified and directed by Engr-in-Charge.
46Only Supply of engine oil 15 W 40 in sealed Packing , complete all as specified and directed by Engr-in-Charge.
47M&L for replacement of three phase Digital Voltmeter 0-500V AC , complete all as specified and directed by Engr-in-Charge.
48M&L for replacement of three phase Digital Ammeter 30/5A(CTR) , complete all as specified and directed by Engr-in-Charge.
49M&L for replacement of voltmeter selector switch , complete all as specified and directed by Engr-in-Charge.
50M&L for replacement of Ampere meter selector switch , complete all as specified and directed by Engr-in-Charge.
51Dismantling existing U/S battery charger & S/F of SMPS type battery charger suitable for 12 V DC with auto cut off from trickle to boost alongwith AC lead to charge the battery when DG Set is not in use complete all as specified & directed by Engineer Incharge.
52M&L for replacement of V belt for fan pulley (set of 2Nos) for DG set upto 320 KVA DG Set , complete all as specified and directed by Engr-in-Charge.
53M&L for replacement of V belt for alternator and water pump assembly for DG set upto 320 KVA , complete all as specified and directed by Engr-in-Charge.
54Material & labour for carrying out complete overhauling / servicing of DG set panel / AMF panel / control panel, including checking and rewiring faulty electrical circuit using 2.5 sqmm FRLS copper conductor, for DG Set of any type / make / capacity, making all electric connections and testing for smooth operation , complete all as specified and directed by Engr-in-Charge.
55Supply and fixing of 'under/over voltage relay, 3 phase, 415 volts', for DG sets of capacity upto 320 KVA , complete all as specified and directed by Engr-in-Charge.
56Supply and fixing in replacement of battery voltage relay 12 VDC, complete all as specified and directed by Engr-in-Charge.
57Supply and fixing in replacement Battery 12 Volt 180 AH , complete all as specified and directed by Engr-in-Charge.
58Supply and fixing in replacement Battery 12 Volt 80/100 , complete all as specified and directed by Engr-in-Charge.
59S&F in replacement of Battery 12 Volt, 18/26 AH , make as per sample complete all as specified and directed.
60Supply and fixing in replecement of 110 Amp,4pole, 415 Volts, 50 Hz Power contactor (MNX110) auxilary contact 2 NO + 2 NC, of coil voltage 240 Volts, complete all as specified and directed by Engr-in-Charge.
61Supply and fixing in replecement of 160 Amp,4pole, 415 Volts, 50 Hz Power contactor (MNX140) auxilary contact 2 NO + 2 NC, of coil voltage 240 Volts, complete all as specified and directed , complete all as specified and directed by Engr-in-Charge.
62Supply and fixing in replecement of Electronic Microprocessor based controller unit suitable to DG set controlls & commands of 62.5 KVA capacity with all listed parameters as per recomendation including testing complete all as specified and directed by Engr-in-Charge.
63Supply and fixing in replecement of Electronic Microprocessor based controller unit suitable to DG set controlls & commands capacity upto 200 KVA DG set with all listed parameters as per recomendation including testing complete all as specified and directed by Engr-in-Charge.
64Supply and laying in trenches/wall/air armoured cable 1100 Volt multi stranded copper conductor cable of size 2.5 sqmm X 8 core for connection of AMF panel to DG set complete all as specified and directed by Engr-in-Charge.
65Attending of any breakdown of standby supply in any location ,whenever required round the clock ,rectify the fault and restore the standby supply within three hour after receipt of complaint of any nature i.e. Engine, alternator,control panel,AMF panel etc . Note -(i) The cost of replaced spare parts will be paid and measured seperatly. (ii) If complaint is not attended by contractor with in five hour the penality of Rs 500 / per hour to be imposed and amount of penality will be deducted from RAR. (iii) The cost of transportation (to and fro) for all kind of necessary equipment / T&P shall be arranged/brought by contractor to complete the job at site or at E/M yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically ,so contractor to specify the telephone no who will receive the complaint round the clock.
66Material & labour for opening / taking out of injector of DG set of any type/make and capacity 15 KVA to 320 KVA disconnection and opening of fuel injector assembly, carrying complete overhauling/servicing fuel injection system with including replacement of injector repair kit ,including calibration of injector, checking of pressure complete for each injector and re-assembling the same, fitted with DG set properly in original location, checking the allignment, making proper fuel connection, testing for smooth opreatio complete all as directed.
67M&L in replacement of unsv thermostat with new thermostat alongwith complete assy for DG set connection testing, complete all as specified and directed by Engr-in-Charge.
68Material & labour for complete overhauling,servicing of turbo charger, opening /taking out of turbo charger of DG set of 15 KVA to 320 KVA capacity ,disconnection of air supply connection pipe etc, including replacement of turbo charger repair kit, calibration/ testing of turbo charger system complete and re-assembling the same ,fitted with DG set properly in original position, checking the allignment, making proper all connection, testing for smooth opreation from authorised rep or service engineer from the manufacturer, complete all as specified and directed by Engr-in-Charge.
69M&L for capacity 15 to 320 KVA complete descaling of cooling system by radiwash with two times circulation of radiwash by means of running of engine & cleaning of fan blades, crankcase breather, radiator and its fins by means of high pressure air or water, complete all as specified and directed by Engr-in-Charge.
70M&L for replacement of Copper tube (Thimbles) terminal heavy duty of size 185 Sq.mm , complete all as specified and directed by Engr-in-Charge.
71M&L for replacement of Copper tube (Thimbles) terminal heavy duty of size 150 Sqmm , complete all as specified and directed by Engr-in-Charge.
72M&L for replacement of Copper tube (Thimbles) terminal heavy duty of size 120 Sq.mm , complete all as specified and directed by Engr-in-Charge.
73M&L for replacement of Copper tube (Thimbles) terminal heavy duty of size 95 Sq.mm , complete all as specified and directed by Engr-in-Charge.
74M&L for replacement of Copper tube (Thimbles) terminal heavy duty of size 70 Sq.mm , complete all as specified and directed by Engr-in-Charge.
75Supply & Fix in replacement of change over switch FP 63 Amps, with steel sheet enclouser & side handle, 415 Volt, 4 pole complete, all as directed by Engr-in-Charge.
76Supply & Fix in replacement of change over switch FP 100 Amps,with steel sheet enclouser & side handle, 415 Volt, 4 pole complete, all as directed by Engr-in-Charge.
77Supply & Fix in replacement of change over switch FP 160 Amps,with steel sheet enclouser & side handle, 415 Volt, 4 pole complete, all as directed by Engr-in-Charge.
78Supply & Fix in replacement of change over switch FP 200 Amps,with steel sheet enclouser & side handle, 415 Volt, 4 pole complete, all as directed by Engr-in-Charge.
79Supply & Fix in replacement of change over switch FP 400 Amps, with steel sheet enclouser & side handle, 415 Volt, 4 pole complete, all as directed by Engr-in-Charge.
80Supply & Fix in replacement of change over switch FP 630 Amps, with steel sheet enclouser & side handle, 415 Volt, 4 pole complete, all as directed by Engr-in-Charge.
81Actuator ( in replacement) with spring (sedemac make) complete all as specified and directed by Engr-in-Charge.Make: Cat Part No. 4H .1720.01.0.00 of Kirloskar or as approved by GE.
82Supply & fix in replacement for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 25 x 4 mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common salt including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40x40x5mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 40 mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by Engr-in-Charge. Note: - (i)On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.(ii) Item includes the cost of 7.5 m GI pipe for protection of earth strip. (iii) PCC pits extra cost of addtional length of watering pipe, bends elbows etc.shall be deemed to be included in the quioted rate. (iv) Item includes the cost of 7.5 mtr length copper earth strip 25x4 mm.
83Supply & fix in replacement for earth continuity conductor or main earthing lead fixed to wall on batton or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to pole or any other indicated situation for loop earthing etc as required with 25X4mm galvanised iron strip complete all as specified and directed by Engr-in-Charge
84Dismantling /opening of alternator of DG Set by disconnection of cable connections and flexible coupling, nuts/bolts and alternator foundation nut, bolts including strip opening of alternator and checking out burnt out parts of DG Sets of capacity 62.5 KVA to 320 KVA and taken back in temporary platform complete all as specified and directed by Engr-in-Charge.
85Taking out burnt armature, winding wire and rewinding of armature with super enameled copper winding wire of existing gauge for 62.5 KVA to 320 KVA set wire DG sets complete all as specified and directed by Engr-in-Charge.
86Taking out burnt field coil and rewinding of field coil with super enameled copper winding wire of existing gauge for 62.5 KVA to 320 KVAA sets complete all as specified and directed by Engr-in-Charge.
87Insulation of armature with Class ‘B’ insulation and Varnishing of armature winding and drying up to desired temperature for 62.5 KVA to 200 KVA DG Sets complete all as specified and directed by Engr-in-Charge.
88Insulation of field coils with Class ‘B’ insulation and varnishing of field coils and drying up to desired temperature for 250KVA to 320 KVA Alternator of DG Sets.
89Burnt rectifier of size 2” x 2” x 24 plate (In replacement) set of three complete all as specified and directed by Engr-in-Charge.
90Re-assembling of rotor and starer after rewinding and re-fixing of Alternator with Engine by assembling flexible coupling with alternator mounting with nuts, bolts including making cable connection complete including testing and commissioning at desire load of DG Set of capacity 62.5 KVA to 320 KVA complete all as specified and directed by Engr-in-Charge..
91Supply & Fix in replacement Single core, copper cable,70 sqmm, 1100 Volt suitable for existing DG set including propper connection from DG set to AMF Panel / Changeover complete all as specified and directed by Engr-in-Charge.
92Supply, laying, jointing & testing in replacement XLPE insulated, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade cross sectional area 400 Sqmm 3.5 core laind in trenches or passing through pipe or fixed on poles complete all as specified and directed by Engr-in-Charge.
93Description all as per serial item No 88.00 here-in-before but of size 120 Sqmm 3.5 core
94Description all as per serial item No 88.00 here-in-before but of size 95 Sqmm 3.5 core
95Description all as per serial item No 88.00 here-in-before but of size 16 Sqmm 4 core
96Taking down the unserviceable LT cable of any size from tranches/ walls /floor etc complete all as specified and as directed by engineer in charge.
97Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes foundations of poles/stays/pipes etc .not exc 10 Sqm area on plan and getting out in soft/loose soil complete all as specified and directed by Engr-in-charge
98Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-charge.
99Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge.
100S&F double walled corrugated (DWC) pipe of size 77 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as spd and directed. Make: REX/Tirupati Plastomatics Pvt Ltd
101S&F double walled corrugated (DWC) pipe of size 90 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as spd and directed.
102S&F double walled corrugated (DWC) pipe of size 120 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as spd and directed.
103Supply & Fixing Insulation Tape of size 25x3mm(20 Mtrs Length) including taking down the existing unserviceable one, complete all as specified and directed by Engr-in-Charge.
104Supply and Fixing LT Junction box cubical type of size 60x40x30 cm, 415 volts for outdoor use made out of CRCA Sheet 3.15 mm thick powder coated, machine passed front opening with sigal door with privision of rubber beading and locking system including aluminium bus bar 4 srip of size 30mm wide and 6mm thick with provision of hole on bus bar fixing of cable mounted on PVC/ epoxy insulators, mounted on angle legs of size 25x25x5mm frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC(1:2:4) Type B-1 (using 20 mm graded stone aggregate) complete including all provision of opening for incomming/Outgoing cables and testing complete all as directed by Engr-in-charge.
105Supply, Installatio,Testing and commissioning of ACB (Air Circuit Breaker) of 800A 4 Pole 50 Ka MF Breaking capacity having Ics=Icu=Icw. The ACB should have intelligent Microprocessor based release having LSIG protection (Overload,Short circuit and earth fault protection along with function blocking feature). The ACB should have rated operational volatage of 690V, Impulse withstand voltage of 12kv and insulation voltage of 1000V, The ACB Should have an inbuilt LCD display having current and voltage metering.The ACB should also be capable of recording and displying a minimum of 50 fault history along with date and time stamping. The release should also have advanced protection features like Over voltage release, Under voltage release, Over frequency protection, under frequency protection, voltage unvalance protection, phase sequence protection etc.The operation counter and contact erosion indicator shall also be inbuilt types and part of the intelligent Microprocessor release.
106Opening, maintenance and general servicing/calibration of ACB (Air Circuit Breaker) of capacity 800 A 4 Pole 50 Ka MF Breaking having capacity Ics=Icu=Icw. incuding removal of sludge from the Panel,Boxes and other components Contects,ACB Chember, cleaning of Chember,Boxes and other components, Resets buttons for mechanicales, OFF Pushbutton, OFF Position Lock, Electricle closing push button,ON Push Button, Springs charged indication, Pushbutton locking, Contact position indication, Operation Counter.and other allied electrical components complete all as specefied and directed by Engr-in-charge. Note: a) ACB (Air Circuit Breaker) must be repaired by original manufacturer or by authorised service provider of the company.b) Spare parts required for replacement will be measured and paid for separately under respective items of schedule labour for fixing parts is included in the unit rate of item c) All T & P and transportaion arrangement are deemed to be included in the rates quoted.
107M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600mm x 6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32 x 6mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40 x 40 x 5 mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by the Engineer-in-Charge. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

Other Detail

Information Source https://defproc.gov.in/nicgep/app
Download FileName File Description File Size