Name of Work:- M/o Scheme under Nazul A/c-II, Rohini.SH:-Operation & Maintenance of Clear water Booster pump set, DG set & Substation equipment at Block- A and C, Sector-28, Rohini, Ph-IV. | Sl. No. | Item Description | |
| 1 | Operation and maintenance of clear water booster pump set, DG and substation equipment and other allied accessories attached at the following site at different locations of sector-28 at Block ‘A’& 'C, Rohini as per inventory terms & conditions attached. | | 2 | Wireman/Pump/D.G Set operator Grd-I ,2 Nos.-1 no. for morning shift for both the pump houses i.e. from 6.00 a.m. to 2.00 p.m. and 1 No.for evening shift for both the pump houses i.e. from 2.00 p.m. to 10.00 p.m. or as when required. | | 3 | Khallasi cum Chowkidar ,2 Nos.-1 no. for each for pump house in night shift i.e. 10.00 p.m. to 6.00 a.m. | | 4 | Supply & replacement of following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. i/c Rebate for dismantle material.a) 250 A,36KA,FPMCCB | | 5 | b) 400 A,50KA,FPMCCB | | 6 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard DeviationColour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)including rebate for dismantle material..18- 22 Watt Servicing and overhauling the following capacity DG Set of 'Kirloskar' make | | 7 | 320 KVA DG Set i/c supply and replacement of following items/ parts.i. Mobil Oil -50 ltr.ii. Diesel Filter -1 No.iii. Oil Filter -1 No.iv. Super by Pass Filter -1 No.v. Air Filter -1 No.vi. Coolant -30 ltr.vii. Water temp. Gauge -1 No.viii. O Ring -3 Nos. | | 8 | 380 KVA DG Set i/c supply and replacement of following items/ parts.i. Mobil Oil -60 ltr.ii. Diesel Filter -1 No.iii. Oil Filter -1 No.iv. Super by Pass Filter -1 No.v. Air Filter -1 No.vi. Coolant -35 ltr.vii. Water temp. Gauge -1 No.viii. O Ring -3 Nos. | | 9 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | | 10 | 100 watt | | 11 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | | 12 | Single pole and neutral | | 13 | Dehydration and filtration of 400 KVA 11 KV/415V oil type Transformer i /c Servicing, testing of insulation of HT & LT winding. cleaning of transformer, tightening of all HT & LT Cablc, nut bolts etc, testing of transformer like voltage ratio , short circuit, magnetic balance test etc oil testing. oil leakage testing and other required test & job etc complete as required. | | 14 | Supplying of 2 x 10 sq mm sizes of XLPE insulated PVC sheathed Aluminiumconductor un-armoured power cable of 1.1 KV grade confirming to IS:7098 (Part1) and laying on wall surface (clamped with 1mm thick saddle)/recessed conduit including making connection with suitable sizeof aluminum lugs, testingetc. as required and as pertechnical specification enclosed. | | 15 | Repair and rewinding of Following HP motor fitted with Centrifugal pump set suitable for 3 phase 415 volt 50HZ AC Supply i/c, connection plate, loading unloading, painting, dismantling of motor from pump set of foundation and refixing after repair, commissioning, testing etc. complete as reqd i/c credit for dismantled material | | 16 | 120 HP | | 17 | 150HP Please Enable Macros to View BoQ information |
|