Indian Tenders

Tender Notice

TDR 55237750
Tendering Authority Paschimanchal Vidyut Vitran Nigam Limited
Tender No 01/W/EDC-I/SRE/2026-27
Tender ID 2026_PVVNL_1142135_1
Tender Brief Tender for Tender for 01/W/Edc-I/Sre/2026-27 Running Contractor Of Full Deposit Work In The Area Of Edsd Behat Under Edd Behat
City Saharanpur
State Uttar Pradesh
Document Fees INR 1180 /-
EMD INR 10000.0 /-
Tender Value INR 10 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for 01/W/Edc-I/Sre/2026-27 Running Contractor Of Full Deposit Work In The Area Of Edsd Behat Under Edd Behat

Key Dates

Publish Date 25-04-2026
Last Date of Bid Submission 04-05-2026
Tender Opening Date 04-05-2026

Contact Information

Company Name Paschimanchal Vidyut Vitran Nigam Limited
Contact Person Superintending Engineer
Address EDC I Saharanpur

BOQ Items

Name of Work:- fo|qr forj.k [k.M csgV ds vUrxZr fo|qr forj.k mi[k.M&csgV ds dk;Z{ks= es iw.kZ tek ;kstuk@>ViV@fuosk fe= iksVZy ij izkIr vkosnuksa esa Lohd`r izkDyuksa ds vUrxZr ubZ 11 ds0oh0 ,oa ,y0Vh0 ykbZuks dk fuekZ.k djuk ,oa 10@25@63@100@250 ds0oh0,0 ds ifjorZdks dk LFkkfir djus ,oa ifjorZdks dh {kerko`f) djus ,oa 33 o 11 ds0oh0 ,oa ,y0Vh0 ykbZuks ds LFkkukUrj.k djus ds dk;ksZ dk jfuax dkUVªSDV dk dk;ZA
Sl. No. Item Description
1Detail of Work
2Safely cartage of PCC poles 8.5/9 Mtr. Long from ESC, SRE/JE store to site of work including loading & unloading at both ends.
3Safely cartage of PCC poles 11 Mtr. Long from ESC, SRE/JE store to site of work including loading & unloading at both ends.
4Safely cartage of ST Pole 11 Mtr. Long from ESC, SRE/JE store to site of work including loading & unloading at both ends.
5Safe cartage of ST Pole 13 Mtr. Long from ESC, SRE/JE store to site of work including loading & unloading at both ends.
6Safely cartage of other complete line material (Except PCC /ST Poles/11KV & 33 KV XLPE Cable/ LT AB Cable) from ESC, SRE/ JE store to site of work including loading, unloading at both ends.
7Safe cartage of 10/25/63/ 100 KVA T/F from ESC,SRE, to the site of work including loading & unloading at both ends.
8Safely Carriage of 33 KV/11 KV XLPE Cable of size 3X35/3x70/ 3X120/3x185/3x300 sq mm. sq. mm from ESC, SRE/ JE store to site of work including loading & unloading at both end
9Safely Carriage of LT AB Cable of size 3x50+1x35+1x16/ 3x95+1x70+1x16/ 3x120+1x95+1x16 sq.mm. from ESC, SRE/ JE store to site of work including loading & unloading at both end
10Safe cartage of 11KV/33 KV CT/PT Unit from ESC,SRE, to the site of work including loading & unloading at both ends.
11Safe cartage of 11KV/33 KV Metering cubical from ESC,SRE, to the site of work including loading & unloading at both ends.
12Safe cartage of 250 KVA T/F from ESC,SRE, to the site of work including loading & unloading at both ends.
13Construction of plinth for installation of 250 KVA T/F of size 1.5x1.5x1.5 Mtr. made of 9\\" thick wall in all the four sides with 6\\" thick RCC top duly filled with sand & plastered 12 mm. thick in ratio 1:4 with cement & sand on outer surface of brick wall.
14Safely installation of 250 KVA T/F on the Plinth with complete fittings including making HT connections and commissioning.
15Wire mesh fencing of 250 KVA T/F size 2.5x2.5x2.5 mt. grouting making frame of MS angal 35x35x4 mm and fixing four no. MS strip size 25x5 mm at equal distance in between the frame and fixing square mesh 50 mm square in each frame the fencing should cover all side of T/F with providing 1 No. door size 6’x3’ with sitakni & Dandala.
16Earthing of 250 KVA T/F (01 No. body & 01 No. neutral earthing) by boring of 60 ft. deep & fixing of 60 ft.G.I. Pipe 11/2” Dia ( Jindal class B ) and connecting with G.I. Strip of size 40X5 mm and G.I. wire. at bottom of G.I. pipe to the T/F providing of required charcoal & salt in the pipe.
17Erection of single support on PCC poles 8.5/9 Mtr. Long with complete fitting of all accessories of 33/11 KV/LT line properly
18Erection of single support on PCC poles 11 Mtr. Long with complete fitting of all accessories of 33 KV/11 KV/LT line properly
19Erection of double Pole on PCC poles 8.5/9 Mtr. Long with complete fitting with all accessories of 33/11 KV/LT line. Properly
20Erection of double Pole on PCC poles 11 Mtr. Long with complete fitting with all accessories of 11 KV/LT line. Properly
21Erection of single support on ST Pole 11 Mtr. Long with complete fitting of all accessories of 33 KV/11 KV/LT line properly
22Erection of single support on ST Pole 13 Mtr. Long with complete fitting of all accessories of 33 KV/11 KV/LT line properly
23Erection of double Pole on ST Pole 11 Mtr. Long with complete fitting with all accessories of 33 KV/11 KV line. Properly
24Erection of double Pole on ST Pole 13 Mtr. Long with complete fitting with all accessories of 33 KV/11 KV line. properly
25Fixing of 11 KV DO Fuse Set on D/P complete properly
26Fixing of 11 KV TPMO on D/P complete properly
27Providing of HDPE Pipe 160mm dia
28Drilling of earth under Road crossing 1.5 mtr. Deep and laying of 2 No. Parreral HDPE pipe 160 mm dia on 0.5 meter distance by drill machine/JCB machine/ labour.
29Laying of 11KV/33 KV XLPE cable size up to 3X300 sq mm in the 2 No. Parreral HDPE pipe 160 mm dia on 0.5 meter distance.
30Providing and fixing of Number plate with clamp on the each pole.
31Providing and Fixing 11KV/33 KV Danger board with clamp nuts & bolts. for ST Poles made of 3mm thick foam sheet (8\\" X 6\\") with
32Providing and fixing of GI barbed wire on the each pole.
33Providing of Red oxide Paints (British/Asian/enamel paint)
34Providing of Aluminum Paint (British/Asian/enamel paint)
35Painting of ST poles 11 Mtr, SP-55 with 2 coats of synthetic enamel paint after one coat of ready mix primer as well as rubbing/cleaning of surface as required for proper completion of work. and remaining by Aluminum paint including all channels/clamps etc.
36Fixing of 11KV/33 KV stay rods by digging of pits in block of 600X600X300 mm. & with nozzling of stay wire 7/10 / 7/8 SWG and fitting the same on the pole.
37Concreting of stay rod in ratio 1:4:8 with Ist class brick ballast with cement, sand.
38Providing and Fixing of Stone Ped 300x300x75
39Earthing of poles by earthing rod
40Providing of All type MS Clamp for ST Pole/ PCC poles with nuts bolts made of new MS flat iron 50x5 mm.
41Providing and Fixing LT shekel insulator of size 100x115mm
42Providing and Fixing nuts & bolts of various sizes.
43Providing and Fixing Suspention clamp with I- Hook
44Providing and Fixing Dead end clamp with I- Hook
45Providing and Fixing Piercing connector Diff. size.
46Providing and Fixing PG Clamp Diff. size.
47Providing of 1X16 sqmm Cable for connection of Distibution box.
48Providing of 11 KV cable terminations kit out door & indoor of size 3X35/3x70/ 3X120/3x185/3x300 sq mm.
49Providing of 33 KV cable terminations kit outdoor of size 3X120/3x185/3x300 sq mm.
50Providing of G.I. Pipe 100mm 4'' dia Class B
51Providing of G.I. Pipe 150mm 6'' dia Class B
52Removal of old ACSR weasel/Rabbit/Dog conductor from the Existing 33 KV/11KV/ LT lines with making roll of conductor and shifting the same to ESC, SRE/J.E store including loading and unloading at both ends.
53Laying, lifting, Stringing, sagging jumpring & binding of ACSR Weasel Conductor for 11KV/LT Line complete properly.
54Laying, lifting, Stringing, sagging jumpring & binding of ACSR Rabbit Conductor for 11KV/LT Line complete properly.
55Laying, lifting, Stringing, sagging jumpring & binding of ACSR Dog Conductor for 33KV/11KV/LT Line complete properly.
56Removal of 10/25/63/100 KVA T/F from the existing D/P after opening HT & LT connection and shifting the T/F from the site to ESC, SRE/JE store with loading & unloading at both ends.
57Safe installation of 10/25/63/100 KVA T/F on the double pole with complete fittings including making connections and commissioning.
58Safely installation of 11KV/33 KV CT/PT Unit on the double pole with complete fittings including making connections and commissioning.
59Safe installation of 11KV/33 KV Metering cubical in the room with complete fittings including making connections and commissioning.
60Chemical Earthing of Metering cubical/ CT/PT Unit/ 63/100 KVA T/F and connecting with G.I. Strip of size 25X4 mm to the Metering cubical/ CT/PT Unit/63/100 KVA T/F Complete Properly.
61Laying, lifting, Stringing, proper sagging 11 KV/33 KV AB cable of size 3x95+1x70/ 3x120+1x95 sq.mm. including fixing of all accessories.
62Laying, lifting, Stringing, proper sagging LT AB cable of size 3x50+1x35+1x16/ 3x95+1x70+1x16/ 3x120+1x95+1x16 sq.mm. including fixing of all accessories.
63Laying, lifting, stringing proper sagging of 11/33 KV XLPE cable 3X35/3x70/ 3X120/3x185/3x300 sq mm of including complete etc
64Fixing, Making of 11 KV cable terminations kit out door & indoor of size 3X35/3x70/ 3X120/3x185/3x300 sq mm.
65Fixing, Making of 33 KV cable terminations kit out door of size 3X120/3x185/3x300 sq mm.
66Laying and making connections of LT PVC/XLPE cable 2x6/4x16/4x25/4x35/3.5x50/ 3.5x70 / 3.5x150/ sq.mm. from T/F to double pole (approx to 20 Mtr).
67Fabrication charges of Angle & Channal
68Fixing of Distibution box with clamp. 01 & 03 Phese
69Providing & Fixing of SMC Fuse Box for T/F
70Fixing of G.I. pipe 100mm 4'' dia/150mm 6'' dia 3.5 mtr. long at the both side of double pole.
71Hanging of cable on D/P after Fixing of outdoor terminations kits work as per site condition with jumpring complete.
72Concreting of ST poles SP-55, 11 Mtr. & SP-72, 13 Mtr. long with cement concreting in bolck of 600X600X1500 MM. in ratio 1:4:8 with cement, sand and brick ballast size 1''x1.5'' with plinth.
73Dismantling of existing PCC/ST pole after opening of complete accessories Safely carrige from site to ESC SRE including loading & unloading at both ends. Please Enable Macros to View BoQ information

Other Detail

Information Source https://etender.up.nic.in
Download FileName File Description File Size
Download 01w26-27.pdf Tender Documents 0 KB
Download 964b2b65-d86a-491a-9a78-ff271b61af8a.html Tender Documents 0 KB
Download BOQ_2133197.xls Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :