Indian Tenders

Tender Notice

TDR 55166282
Tendering Authority General Insurance Corporation Of India
Tender No GIC-HO/OSD/Electrical/25/26-27
Tender ID 2026_GIC_275211_1
Tender Brief Tender For Revamping And Preventive Maintenance Of Entire Meter Room InConsultation With Best. Liaison Charges To Be In The IncludedRates. Cleaning Of Meter Room, Bus Bar Retaping Or New Bus BarsProvision Etc. Complete. , Supply Installation Testi
City Mumbai
State Maharashtra
Document Fees Refer document
EMD INR 200000.0 /-
Tender Value INR 85 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Revamping And Preventive Maintenance Of Entire Meter Room In Consultation With Best. Liaison Charges To Be In The Included Rates. Cleaning Of Meter Room, Bus Bar Retaping Or New Bus Bars Provision Etc. Complete. , Supply Installation Testing and Commissioning of 30 Ma , 63 Amps 4 Pole Rccbs At Distribution Panels. , Supply Installation Testing and Commissioning of 100 Ma , 63 Amps 4 Pole Rccbs At Distribution Panels. , Supply Installation Testing and Commissioning of 100 Ma , 63 Amps 2 Pole Rccbs At Distribution Panels. , Supply Installation Testing and Commissioning of 30 Ma , 63 Amps 2 Pole Rccbs At Distribution Panels. , Preventive Maintenance Of The Main Lt Panel. Tightening Of All The Terminations, Cleaning Of Cable Cores, Of Stencilling Destinations On Rear And Front Sides Of The Panel. Replacement Of Rusted Hardware Etc. , Preventive Maintenance Of The Floor Lt Panels/ Distribution Boards Of All The Tightening Of Cable Terminations, Cleaning Cores, Of Destinations. Stencilling Of Rusted Replacement Hardware, Dressing Of Cables/Wires, Lugs To Be Provided Wherevr Required Etc. , Supply Installation Testing and Commissioning of Earthing Pits As Per The Design Given In Is 3043 With 50 Mm X 2Mtr Dia Gi Earhting Pipe And Chemical, Chmaber Making And Pit Cover To Be Provided. All Earthing Pits To Be Connected In Grid. , Supply Installation Testing and Commissioning of Lt Insulation Mat 2 Mm Thick To Be Spread In Front Of Panels. , Supply And Laying Of 25 X 3 Mm Gi Earthign Strips From New Earthign Pits. , Supply And Laying Of 16 Guage Gi Wire For Extending Earthing Connections. All Panels/Dbs To Be Provided With Two Body Earthing Connections. , Dressing Of All The Hanging Wires In The Offices On All The Floors. All Dead Wires To Be Removed. All Wires Should Be Laid In Pvc Conduits. , Making Of Single Line Diagrams Of The Main Lt Panel And Floor Panels. , Attending To All Miscelleanous Complaints Given In Electrical Safety Audit Report. , Replacement Of Old Single Pole Mcbs By New Mcbs 6 Amps To 32 Amps , Supply Installation Testing and Commissioning of New 4 Pole Mcbs Of 40 Amps Capacity , Supply Installation Testing and Commissioning of New 12 Way Tpn Disribution Boards In Place Including 63A 4P Rcbo 30Ma & 6 To 32A Single Pole Mcv Of Old Kit Kat Fuse Type Boards With All Tpn And Sp Mcbs Of Equvalient Size. , Supply And Fixing Of Danger Boards Of Suitble Size Near Electrical Panels. , Supply And Fixing Of Cpr Charts As Publsihed By National Safety Council Near Electrical Panels. , Preventive Maintenance Of All The Switch Baords Existing In The Gic Building. Also All Joints On Wiring To Be Remade With Connectors Or Proper Insulation Tape. , Supply And Laying Of 4 Sq.Mm Copper Conductor Wire In Pvc Conduits Wherever Required. (Frlsh) Insulated , Provision Of Sand Buckets With Dry Fine Sand Near Main Electrical Room And Lift Room. , Sealing Of Cable Entry Holes In Panels. , Supply And Installation Of Apfc Panel Of 200 Kvar With Associated Cabling Complete. , Supply Of Loto Kit With Locks And Tags For Locking Mcb/Mccb/Sfu. Lockout Tagout Station-1 No, Osha Safety Padlock-10 Nos, Vinyl Coated Hasp Small-2 Nos, Vinyl Coated Hasp Premier-2 Nos, Non - Conductive Hasp With 4 Holes-2 Pc. , Supply, Installation, Testing And Commissioning (Sitc) Of 250 Amps Fp Mccb-1 Nos. & 125 Amps, 4-Pole Mccb - 2 Nos., Complete With A 300 Amps Rated Prefabricated Copper Busbar System, For Replacement Of The Existing Fuse-Type Distribution Board. With Termination Of Existing 70 Sq.Mm/3.5C Cables Complete. , Supply, Installation, Testing & Commissioning (Sitc) Of 1600 Amps, 50 Ka 4P Air Circuit Breaker (Acb) Enclosure With Including Dismantling And Removal Of Existing Old Acb, Complete Replacement, Termination Of Existing Outgoing 400 Sq.Mm/3.5C X 4Nos Cables, Testing And Commissioning As Required. , Supply, Installation, Testing & Commissioning (Sitc) Of Programmable Timer For Automatic Control Of Air Conditioner In Ups Room & Lift Room, Including Wiring, Mounting, Interconnections And Complete Commissioning. , Revamping Of Existing Changeover Switch Including Retrofitting/Replacement Of Switch Mechanism And Hrc Fuses, Complete With Testing And Commissioning. , Supply, Installation, Testing & Commissioning (Sitc) Of Retrofitting Switch For Ups Input And Output Mccb. , Supply Installation Testing and Commissioning of 6 Sq.Mm/4C 2Xfy Frlsh Cable Wherever Required For Looping Of Distribution Board. , Supply Installation Testing and Commissioning of 10 Sq.Mm/4C 2Xfy Frlsh Cable Wherever Required For Looping Of Distribution Board. , Supply, Installation, Testing & Commissioning (Sitc) Of 250 Amps Fp Mccb-1 Nos & 125 Amps, 4 Pole, Mccb-2 Nos , 63 Amps Fp Mcb -9 Nos Complete With 300 Amps Rated Prefabicated Copper Busbar System, For Replacement Of The Existing Fuse Type Distribution Board With Termination Of Existing Cables , Providing All Materials And Labour For Painting Woodwork, Plain Steel Surfaces, Grills, Etc Including Scaffolding, Scrapping Existing Paint Applying One Coat Primer, Filling The Crevices And Holes With Painters Putty And Finishing With 2/3 Coats Of Approved Quality Of Synthetic Enamel Paint On M.S. Grills/ M.S Shop Doors/Main Gate/M.S Structure To Support To Sintex Tank At The Terrace Level,Etc.

Key Dates

Publish Date 20-04-2026
Last Date of Bid Submission 11-05-2026
Tender Opening Date 12-05-2026

Contact Information

Company Name General Insurance Corporation Of India
Contact Person Alfreda Dsouza
Address 170, Suraksha, J Tata Road, Churchgate, Mumbai - 400020

BOQ Items

Name of Work:-
Sl. No. Item Description
1Revamping and preventive maintenance of entire meter room inconsultation with BEST. Liaison charges to be in the includedrates. Cleaning of meter room, Bus bar retaping or new bus barsprovision etc. complete.
2SITC of 30 mA , 63 Amps 4 pole RCCBs at distribution panels.
3SITC of 100 mA , 63 Amps 4 pole RCCBs at distribution panels.
4SITC of 100 mA , 63 Amps 2 pole RCCBs at distribution panels.
5SITC of 30 mA , 63 Amps 2 pole RCCBs at distribution panels.
6Preventive maintenance of the main LT panel. Tightening of allthe terminations, cleaning of cable cores, of stencillingdestinations on rear and front sides of the panel. Replacementof rusted hardware etc.
7Preventive maintenance of the floor LT panels/ distributionboards of all the Tightening of cable terminations, cleaningcores, of destinations. stencilling of rusted Replacementhardware, dressing of cables/wires, lugs to be provided wherevrrequired etc.
8SITC of earthing pits as per the design given in IS 3043 with 50mm X 2Mtr Dia GI earhting pipe and chemical, chmaber makingand pit cover to be provided. All earthing pits to be connected ingrid.
9SITC of LT insulation mat 2 mm thick to be spread in front ofpanels.
10Supply and laying of 25 x 3 mm GI earthign strips from newearthign pits.
11Supply and laying of 16 guage GI wire for extending earthingconnections. All panels/DBs to be provided with two bodyearthing connections.
12Dressing of all the hanging wires in the offices on all the floors.All dead wires to be removed. All wires should be laid in PVCconduits.
13Making of single line diagrams of the main LT panel and floorpanels.
14Attending to all miscelleanous complaints given in electricalsafety audit report.
15Replacement of Old Single pole MCBs by new MCBs 6 Amps to32 Amps
16SITC of new 4 pole MCBs of 40 Amps capacity
17SITC of new 12 way TPN disribution boards in place Including63A 4P RCBO 30mA & 6 to 32A Single Pole MCV of old KIT Katfuse type boards with all TPN and SP MCBs of equvalient size.
18Supply and fixing of danger boards of suitble size near electricalpanels.
19Supply and fixing of CPR charts as publsihed by National Safetycouncil near electrical panels.
20Preventive maintenance of all the switch baords existing in theGIC building. Also all joints on wiring to be remade withconnectors or proper insulation tape.
21Supply and laying of 4 sq.mm copper conductor wire in PVCconduits wherever required. (FRLSH) Insulated
22Provision of sand buckets with dry fine sand near main electricalroom and lift room.
23Sealing of cable entry holes in panels.
24Supply and Installation of APFC panel of 200 KVAR withassociated cabling complete.
25Supply of LOTO kit with locks and tags for lockingMCB/MCCB/SFU. Lockout Tagout Station-1 No, Osha SafetyPadlock-10 Nos, Vinyl Coated Hasp Small-2 Nos, Vinyl CoatedHasp Premier-2 Nos, Non - Conductive Hasp With 4 Holes-2 Pc.
26Supply, Installation, Testing and Commissioning (SITC) of 250Amps FP MCCB-1 Nos. & 125 Amps, 4-Pole MCCB – 2 Nos.,complete with a 300 Amps rated prefabricated copper busbarsystem, for replacement of the existing fuse-type distributionboard. with termination of existing 70 sq.mm/3.5C cablescomplete.
27Supply, Installation, Testing & Commissioning (SITC) of 1600Amps, 50 kA 4P Air Circuit Breaker (ACB) enclosure withincluding dismantling and removal of existing old ACB, completereplacement, termination of existing outgoing 400 sq.mm/3.5C x4Nos cables, testing and commissioning as required.
28Supply, Installation, Testing & Commissioning (SITC) ofprogrammable timer for automatic control of Air Conditioner inUPS room & lift room, including wiring, mounting,interconnections and complete commissioning.
29Revamping of existing changeover switch includingretrofitting/replacement of switch mechanism and HRC fuses,complete with testing and commissioning.
30Supply, Installation, Testing & Commissioning (SITC) ofretrofitting switch for UPS input and output MCCB.
31SITC of 6 sq.mm/4C 2XFY FRLSH cable wherever required forlooping of distribution board.
32SITC of 10 sq.mm/4C 2XFY FRLSH cable wherever required forlooping of distribution board.
33Supply, Installation, Testing & Commissioning (SITC) of 250 AmpsFP MCCB-1 Nos & 125 Amps, 4 Pole, MCCB-2 Nos , 63 Amps FPMCB -9 Nos Complete with 300 Amps rated prefabicatedcopper busbar system, for replacement of the existing fuse typedistribution board with termination of existing cables
34Providing all materials and labour for painting woodwork, plain steel surfaces, grills, etc including scaffolding, scrapping Existing paint applying one coat primer, filling the crevices and holes with painters putty and finishing with 2/3 coats of approved quality of Synthetic enamel paint on M.S. grills/ M.S shop doors/main gate/M.S structure to support to sintex tank at the terrace level,etc. Please Enable Macros to View BoQ information

Other Detail

Information Source https://etenders.gov.in/eprocure/app
Download FileName File Description File Size
Download BOQ_321493.xls Tender Documents 0 KB
Download f652c87d-4cfe-4902-9633-20e27b91e1b1.html Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB