Indian Tenders

Tender Notice

TDR 55165489
Tendering Authority Jammu And Kashmir State Sports Council
Tender No E NIT NO 04 OF 2026-27 DATED 20.04.2026
Tender ID 2026_SPORT_308276_1
Tender Brief Corrigendum : Tender For Flood Restoration And Reconstruction Of Indoor Hall Atbhagwati Nagar, Jammu (Phase-I)
City Jammu
State Jammu And Kashmir
Document Fees INR 3000 /-
EMD INR 457460.0 /-
Tender Value INR 2.28 Crore /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Flood Restoration And Reconstruction Of Indoor Hall Atbhagwati Nagar, Jammu (Phase-I)

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 09-05-2026 REGARDING DATES 3 Date 12-05-2026
2 05-05-2026 REGARDING DATES Date 08-05-2026
3 05-05-2026 REGARDING DATES Date 08-05-2026

Key Dates

Publish Date 09-05-2026
Last Date of Bid Submission 12-05-2026
Tender Opening Date 13-05-2026

Contact Information

Company Name Jammu And Kashmir State Sports Council
Contact Person Ex Engineer
Address EX ENGINEER OFFICE AT SPORTS HOUSE MA STADIUM

BOQ Items

Name of Work:- Flood Restoration and reconstruction of Indoor Hall atBhagwati Nagar, Jammu (Phase-I)
Sl. No. Item Description
1Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
2Finishing walls with premium Acrylic smooth exterior paint with silicon additives of required shade: Old work (Two or more coats applied @ 1.43 liters/ 10 sqm) over existing cement paint surface
3Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminum snap beading shall be paid in basic item.)With float glass panes of 4 mm thickness (weight not less than 10.0 kg / sqm)
4Providing and fixing 4 mm thick ACP Sheet in panelling fixed in aluminum doors, windows shutters and partition frames (aluminum/ woodedn) with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-incharge. (RATE ANALYSIS =1290*1.18*1.35)
5Providing and fixing EPDM rubber in doors and windows of aluminium wherever necessary as per direction of engineer in charge
6Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg for doors including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineerin- plate etc. complete as per the direction of Engineer-in-charge.With Stainless Steel cover plate minimum 1.25 mm thickness
7Providing and fixing fly proof wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions all complete.
8Providing and fixing Aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colours or shade with necessary screws etc complete job. 200x10mm
9Providing and fixing Aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colours or shade with necessary screws etc complete job. 100x10mm
10Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colours and shade with necessary screws etc complete including all leads, lifts and carriages complete. 125 mm
11Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colours and shade with necessary screws etc complete including all leads, lifts and carriages complete. 100mm
12Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300x16 mm
13Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 300x10 mm
14Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 150 mm
15Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work.
1612mm Cement plaster of mix:1 : 6 ( 1 cement : 6 fine sand)
17Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations.a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with waterproofing compound conforming to IS 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs)c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge.d) finishing the surface with 20mm thick joint less cement mortar of mix1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep.e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineerin-charge.23.7.1 With average thickness of 120mm and minimum thickness at khurra as 65 mm
18Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge In cement mortar
19Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead Of area of 3 sqm. and below
20Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead.For thickness of tiles 10 mm to 25 mm
21Dismantling of flushing cistern of all types(C.I/PVC/Vitreous china) including stacking of useful materials near the site and disposal of unserviceable materials within 50 meters lead
22Labour engaged for Dismantling white vitreous china pedestal type water closet (European & indian type W.C. pan) with seat and lid
23Labour charges for welder for refixing of ss railing.
24Labour charges for helper
25Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:1½:3 (1 cement :1½ coarse sand: 3 graded stone aggregate 20 mm nominal size)
26Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand)
27Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
28Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand)
29Extra for half Brick masonry in superstructure above plinth level upto floor V level.
3015mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand)
31Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete
32Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
33Providing and fixing in position insulated Sandwich Puff Panel 50mm thick, external wall in galvanised steel 24G, internal wall in galvanised 24G external and internal coating in regular modified polyester coating in standard RAL shade. Roof and wall panel shall be 24 gauge inside and outside. Base material for colourcoated galvanized or galvalume substrate steel panels shall have minimum yield strength of 345 Mpa Wall /Roof Sandwitch Puff Panels
34Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm)
35Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Gutter .(600 mm over all girth
36Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including: a) Structural analysis & design and preparation of shop drawings for pressureequalization or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metallic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanized with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bimetallic contacts all complete required to perform as per specification and drawing The item includes cost of all material &labour component, the cost of all mock ups at site, costof all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant item The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places
37Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour or shade
38Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour or shade (Area of slab over 0.5 sqm)
39Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge All kinds of soil :
40Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: 2.8.1 All kinds of soil :
41Earthwork in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5mtr in width) and for shafts, wells, cesspits and the like not exceeding 10 sq.m on plan, depth upto 1.5 mtr including disposal of excavated earth upto 1.0mtr from cutting edge, disposed earth to be levelled and neatly dressed including all leads, lifts and carriages complete.
42Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
43Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
44Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
45Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
46Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
47Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
48Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases of columns etc. for mass concrete.
49Centering and shuttering including strutting, propping etc. and removal of form work for: Lintel, beams, plinth beams, girders, bressumers and cantilevers.
50Labour charges for steel work in builtup section (angle, round, square / rectangular etc) including cutting, dismantling and refixing in position by way of welding / bolting as per the direction of engineer incharge.
51Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm
52Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of tile 600x600 mm
53Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
54Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of tile 600x600 mm
55Providing and fixing aluminium work for doors, windows, ventilatior and partion with extruded built up standard tubular section,Z section and other sections of approved make and ISI 1285, fixed with dash fasteners of required dia and size including necessary filling up the gaps at the junction i.e.0top, bottom and sides with required EPDM rubber I neoprene gasket felt etc. Aluminium section shall be smooth,rust free, straight,mitred and jointed mechanical wherever required including cleat angle, aluminium snap beading for l panelling,C.P.brass stainless steel screws,all complete,For fixed portion . Powder coated aluminium.take 20076 aluminium frame section @ 1.608 Kg/mtr
56For shutters of doors, windows & ventilators including providing and fixing hinges l pivot and making provision and fixing of fittings wherever required including the cost of EPDM rubber gasket required. take 19581 aluminium door section @ 1.38 Kg/mtr
57Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-incharge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side.
58Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin- charge. (Cost of aluminum snap beading shall be paid in basic item.) With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm)
59Providing and fixing hardware fixtures (Aluminium) ISI marked anodised (Anodic coating) not less than grade AC 10 as per IS-1868 tower bolt200x10mm
60Providing and fixing hardware fixtures (Aluminium) ISI marked anodised (Anodic coating) not less than grade AC 10 as per IS-1868 handle 125mm
61Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade, one or more coats on old work.
62Providing and fixing FLOOR-MOUNTED cubicals for WC of size 900 x 1550 x 2065 mm made of 12 mm thick HPL compacted board with door of minimum 610 mm wide. The bottom gap shall be 100 mm and pilaster width shall be 400 mm. The cubical shall be equipped with Stainless Steel Top Rail Arrangement and all accessories like U-channel, F- Channel, Spring loaded butt hinges, Thumb turn with occupancy indicator knob, door stapper shall be SS made and specification as approved / specified in company product cataloug. The product should be impact, scratch, Fire, water abrasion, cigarette burn, chemical, termite resistant. The work shall be carried out through persons authorized by the company and shall be completed as per direction of engineer Incharge and product shall be of Greenlam/ Merino / Megha System or equivalent make.
63Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.
64Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge.
65Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: Flexible pipe 32 mm dia
66Providing and fixing CP Brass toilet paper holder to the wall of approved design and make as per direction of Engineer-in-charge.
67Providing and fixing CP brass health faucet with tube and hook etc. complete as per direction of Engineer-in-charge
68Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single Hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
69Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
70Providing & fixing white vitreous china water less urinal of size 600 x 330 x 315 mm having antibacterial /germs free ceramic surface, fixed with cartridge having debris catcher and hygiene seal.
71Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour: Waste coupling 38mm of 83 mm length and 77 mm breadth weighing not less than 60gms
72Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour 600 mm long towel rail with total length of 645 mm, 78 mm wide and effective height of 88 mm, weighing not less than 190 gms.
73Providing and fixing S.S.Towel Rail 600mm Long , of approved quality. (Make - JAQUAR/KOHLER/ROCA)
74Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms.
75Providing and fixing SS Soap dish
76Providing and fixing wall hung gel dispenser of desired pattern including all accessories as per direction of Engineer-in-charge. (Make : ROCA Hotel's 2.0 model Model No RA816391001 / Equivalent in Kohler / Grohe)
77Providing and fixing CP Brass Towel Ring etc. complete as per direction of Engineer-in-Charge. (Make: ROCA Model No. RA816711001 / Equivalent in Kohler / Grohe)
78Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms
79Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms
80Providing and fixing 15 mm nominal bore C.P. stop cock (concealed) of standard design and of approved make conforming to IS : 8931
81Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931
82Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931.
83Providing and fixing un plasticized P.V.C. connection pipe with PTMT nuts, collars and bush of approved quality and colour
84Providing and fixing Curved shaped urinal partition with frosted glass 8mm thick with Chrome Finish Size H: 900 W: 450
85Providing and fixing Heavy class SS grating with Cockroach proof SS strainer of approved design including setting in floor with cement motor to match with floor finish as per complete as per direction of Engineer-in-charge.For FT & FD of Size 100 mm x 100 mm
86Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-Charge and finished smooth. 16/18 mm Granite Stone of approved shade
87Providing and fixing beveled edge 8 mm mirror of superior glass (of approved quality) complete with Spacer & C.P. brass screws and washers complete.
88Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diametre
89Providing and fixing on wall face un-plasticized - PVC moulded fittings /accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion 110 mm Bend 87.5°
90Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 75 mm diametre
91Providing and fixing on wall face un-plasticized - PVC moulded fittings/ accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion 75 mm Bend 87.5°
92Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. 15mm nominal outer dia pipes.
93Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.20mm nominal outer dia pipes.
94Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. 15mm nominal outer dia pipes.
95Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. 20mm nominal outer dia pipes.
96Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. 25mm nominal outer dia pipes.
97Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. External work including trenching, refilling etc 50 mm nominal outer dia pipes.
98Providing and fixing PTMT extension nipple for water tank pipe, fittingsof approved quality and colour 40 mm nominal bore, weighing not less than 62gms
99Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 50 mm nominal bore
100Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
101Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 150 mm diameter
102Providing and Fixing in position storage type hot water electrical heaters with copper container, insulation, and stove-enamelled M.S jacket, thermostatically controlled immersion heater, with pilot lamp, 15/20mm dia inlet with non-return valve and 15/20mm dia outlet including making connections complete in all respect. (wall mounted with suitable M.S bolts and nuts) (Make -Venus/ havells/crompton) Capacity 25 litres
103Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
104Applying priming coat: With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel galvanized iron/steel works
105Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coat on new work
106Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix)
107Excavating, supplying and filling of local earth (including royalty)by mechanical transport upto a lead of 5 km also including ramming and watering of the earth inlayers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
108Supply and Installation of BasketBall Rings with 25 Acrylick Back board and frame complete as per direction of Engineer incharge
109Romoving of old vineyl sports flooring and cleaning of Floor and treatment of floor with anti termite compound and Providing and Installation of MAPLE WOOD SPORTS FLOORONG as per specifications laid under:-1. Vapour Barrier- 0.20 mm thich Polyethylene memberane installed over the concrete base beneath flooring with joints lapped @ 150 mm. 2. Cushion Pads- 19 mm thick cushion pads placed under the wooden sleepers for extra resilience, stapled through the two wings at 300 mm x 300 mm3. Pine/Fir Wood Sleepers - The under frame made of commercial qualityPINE WOOD runners of 70 mm wide x 45 mm thick, treated with anti-termite solution and installed @ 305 mm centre to centre.4. Maple Flooring – 21 mm Thick with width varying from 57 to 83 mm jointed togeather with Tongue & Groove on all 4 sides on all boards, kiln dried and treated with anti-termites and water resistant lacquer.5. The surface board to be nailed with Pressure machine to the runner through the tongue only. The floor should be machine sanded and finished with WATER BASED POLYURETHANE POLISH. The Product Should be BWF/ FIBA approved, with warrenty of 7 years and shall be installed after prior approval of Engineer Incharge.
110Providing and Fixing MS Sheet of required width of 1.0 mm thickness at Eveas level to protect entry of Pigeons including cost of screws, labour and scaffolding required complete job as per the direction of enginere incharge.
111Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 meter lead as per direction of Engineer-in-Charge.
112Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in- charge
113Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as per direction of Engineer-in-Charge.16.94.1 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
114Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete
115Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement: 3 coarse sand) including making joints with or without grooves (thickness of the joints except at sharp curve shall not to be more than 5mm) including making drainage opening wherever required complete etc. as per direction of Engineer-incharge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
11615mm Rock Fiber False Ceiling WHITE SHADE FOR HALL (Bio-Safe):Providing and fixing Rock Fiber (Bio-Safe) Acoustical (NRC 0.9- 0.95) Micro Look Edge False Ceiling Tile of size 595X595X15mm of approved texture, design and pattern. Rock Wool Tile should have Acoustical Tissue Paper on the top face and Harden edge to achieve NRC upto 0.95 as per ASTMC423/ISO354. The tiles should have Anti Bacterial coating & Passed the Test Method as per JIS Z 2801: 2010, Should passed resistance to fungal attack test as per ASTM: G21-15. Relative Humidity (RH) more than 85%, Fire Performance as per Vertical flammability test (UL94) Classification V1(Flame extinguishes within 30 seconds with no dripping) in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.30 mm thick (galvanized @120 GSM) comprising of main T runners of 15x32 mm (Centre Black) of length 3000 mm, cross T of size 15x32mm (Centre Black) of length 1200 mm and secondary intermediate cross T of size 15x32 mm (Centre Black) of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80GSM) 50 mm long 8mm outer diameter M-6 dashfasteners,4mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size 22x19x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic raw l plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T- sections used in false ceiling support system shall be pre- painted with polyester baked paint, for all heights. (Supplier Company should be OEM and OEM Test Certificates will be required from contractor before billing of the item). The work shall be carried out as per specifications, drawings and as per directions of the Engineer-In-Charge.
117Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm widex1.6mm thick with flanges of 27mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x40mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.5mm of required length with nuts & bolts of required size and other end of angle hanger fixed with G.I. channels 45x15x0.9 mm running at the spacing of 1200 centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having clips of 10.5 mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diaX230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre to centre, with 25mm long drive-all screws @ 230 mm interval ,including fixing of gypsum board/calcium silicate board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the gypsum board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers’ specification and also including the cost of making openings for light fittings, grills diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer-in-Charge but excluding the cost of painting with: Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in- charge and as per manufacturer’s specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60
118Acoustical Wall Panelling ;- Providing and fixing GI frame work for wall paneling as per design drawing consisting of floor channel of size 50x32x32 x0.5mm thick at bottom and top fixed with 35 mm nylon sleeves and 35 mm screw. Further fixing GI stud 48x34x36x0.5 mm thick @600mm C/C vertically. The framework to be filled with 50mm 1000 GSM non-woven thermal bonded polyester wadding. Finally fixing over it horizontally 80x26x51x0.5 mm thick G.I. ceiling section placed @600mm C/C orwherever required as per design drawings with dry wall screws and soffit cleats 27x37x25x1.6 mm as required. The frame to be fixed to the walls by means of angle hold fastener cleats of required size complete with required metal screw fixed on each vertical member @1000mm C/C etc. as required all complete as per the directions of Engineer-in-Charge. 12.5mm Thick Gypsum Plaster Acoustical Board ( Petal) With atleast 15% perforation back side acoustical fleece dualy fixed on the G.I frame as mention above to get NRC 0.7 (Original equipment manufacturer MTC with NRC certificates will be required on installation)
119Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick
120Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm
121Finishing wall with premium acrylic smooth exterior paint with silicone additives of required shade on New work (two or more coats applied @ 1.43 liter/10sqm over and including priming coat of water exterior paint applied @ 2.20kg/10sqm)
122Steel work welded in built up section framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer.
123Providing and Fixing of LED light 3 D letters / LOGO BOARD including all necessary wiring, all complete as per direction of engineer incharge
124Carriage of Sand
125carriage of Stone Aggregates
126Carriage of brick
127Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
128Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required.
129Wiring for Light /Power Plug with 2 x 2.5 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 2.5 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required.
130Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
131Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connection,painting etc. as required.
132Installation, testing and commissioning of 200 mm sweep exhaust fan with robust motor, gravity shutters with speed rating of 1350 revolution per minute complete with all accessories etc. directly on ventilator , including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. Firm has to submit originallity certificate of material from OEM or Authorized Distributor with 05 years of warranty.
133Supplying and fixing of following rating 240/415 volts \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole upto 32 amp.
134Installation testing and comissioning of linear surface wall mounted 20 watt Mirror light luminaire with Luminous efficiency of luminaire 100 lm/W; CRI > 80; minimum system lumen output of 2000 lumens Dimension :- 595mm Body of extruded aluminium profile and polycarbonate cover. Firm has to submit Certification-LM 79 and LM 80.The test report should be from Govt. Approved Lab/inhouse NABL Lab with 05 years of warranty.
135Installation testing and comissioning of linear surface wall mounted 36 watt light luminaire with Luminous efficiency of luminaire 100 lm/W; color rendering index Ra > 80; minimum system lumen output of 4000 lumens and maximum system wattage of 12W; Dimension :- 1200 mm Body of extruded aluminium profile and polycarbonate cover.
136Supply, Installation, testing and commissioning of led light Bulb 9 watt
137Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
138Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet
139Supply, Installation, Testing and Commissioning of 100 w Highbay LED luminaire Luminous Flux 13,000 lm, Correlated Color Temperature (Nom) 6500 K, Luminous Efficacy (rated) (Nom) 130 lm/W, Color rendering index (CRI) >80, Light source color 865 cool daylight, Effective projected area 0.06 m², Input Voltage 220 to 240 V Line Frequency 50 or 60 Hz, Inrush current 40 APower Consumption 100 W, Power Factor (Fraction) 0.95. Firm has to submit originallity certificate of material from OEM or Authorized Distributor with 05 years of warranty.
140Installation, testing and commissioning 450mm dia sweep Heavy wall air circulator oscillating type, Hi speed with 3 speed push buttons, 1440 RPM, with guard and mounting arrangement. Similar to Havells make - TURBO FORCE or equivalent
141LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). 200 watt Each 4689
142Supplying and fixing 25 ltr water heater (gyser) with all necessary fitting
143Supplying and fixing single pole blanking plate in the existingMCB DB complete etc. as required.
144Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 4 way (4 + 12), Double door
145Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 6 way (4 + 18), Double door
146Supplying and fixing 5 amps. to 32 amps.rating 240 volts 'C' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. SPN 32 A
147Supplying and fixing 5 amps. to 32 amps.rating 240 volts 'C' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. TPN 63 A
148Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
149Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
150LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 36 watt
151Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
152Supplying and fixing Stepped Type Electronic Fan Regulator on the existing Modular Plate Switch Box including Connections but Excluding Modular Plate etc. as Required.
153Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required. 3.5 C X 35 Sq.mm A2XFY
154Supplying, installation, testing and commissioning of 80 Liters of water Cooler having full stainless steel body, cooling capacity 80 ltr/hour and storage capacity 80 ltr alongwith PVC connecting pipes as required. Warrantee.:- 3 Years from the date of installation. .
155Supplying, installation, testing and commissioning of following type of water purifiers alongwith PVC connecting pipes as required (RO + UV + UF mineral control with TDS control ) Warrantee.:- 3 Years from the date of installation.
156Supplying, Installation, Testing & Commissioning of following capacity automatic voltage stabilzer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary. 2kv Warrantee.:- 3 Years from the date of installation.
157Supply and fixing Sine Wave Inverter 2000 VA with necessary connection and accessories like Socket and modular plates for connection in existiong electirc fitting as per the direction of Engineer Incharge
158Supply and fixing battery 12 volt Tubular 150 AH with 36 month Gurranty Please Enable Macros to View BoQ information

Other Detail

Information Source https://jktenders.gov.in
Download FileName File Description File Size
Download BOQ_999203.xls Tender Documents 0 KB
Download fcaa3b16-193f-4655-a5f5-34c36bb7c8db.html Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.