Tendering Authority Military Engineer Services
Tender No 8984/E8
Tender ID 2026_MES_761099_1
Tender Brief Corrigendum : Tender For Repair/ Replacement & Maintenance Electrical Works In Otm/ Md Accn At Dronachal Base & Top Under Ge Dronachal
City Bhopal
State Madhya Pradesh
Document Fees INR 500 /-
EMD INR 50000.0 /-
Tender Value INR 25 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Repair/ Replacement & Maintenance Electrical Works In Otm/ Md Accn At Dronachal Base & Top Under Ge Dronachal

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 02-05-2026 POSTPONNED Date 16-05-2026

Key Dates

Publish Date 02-05-2026
Last Date of Bid Submission 16-05-2026
Tender Opening Date 18-05-2026

Contact Information

Company Name Military Engineer Services
Contact Person Shri Ankit Goyal, IDSE
Address GE Dronachal, Dronachal Top, Neori Hills, Bhopal 462038

BOQ Items

Name of Work:- REPAIR/ REPLACEMENT & MAINTENANCE ELECTRICAL WORKS IN OTM/ MD ACCN AT DRONACHAL BASE & TOP UNDER GE DRONACHAL
Sl. No. Item Description
1Taking down carefully copper/aluminium point wiring from wooden battan/ conduits or from the wall by chasing/cutting (light, fan, socket or power etc) completely, including fittings (such as switches, ceiling roses, pendants, regulator, sockets etc) and making good disturbed surfaces of walls, floor as it is etc. complete all as specified and directed by EIC.
2Taking down old DBs including existing MCCBs,MCB TPN and connected items of any make and type from the site and making good surface complete all as specified and directed by EIC.
3Taking down old submain wiring of any size and make from the site and making good surface complete all as specified and directed.
4Taking down old unsv light fitting, Security light ,bulb of any size and make from the site and making good surface complete all as specified and directed by EIC.
5M&L point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing concealed in wall & including rigid PVC conduit FRLS, medium grade ,ISI marked ,terminal box of 1.2 mm thick and 60 mm depth its also including various sizes of module plates in gray colour also including porvision of earth wire PVC insulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly complete all as speccified and as directed
6One light/fan point controlled by one way switch (switch to be measured and paid separtely)
7One light point controlled by two way switch (switch to be measured and paid separtely)
8One socket outlet on same board ( switch & socket to be measured and paid separtely)
9One 5 pin socket outlet 5 hole 5 Amp independent including PVC unsheathed copper conductor 1.5 Sqmm cable as earth wire connected to common earth and to earth dully socket & switches to be measured and paid separately.
10-ditto- as above item No 5.04 but copper conductor 2.5 sqmm ( switch & socket to be measured and paid separtely)
11-ditto- as above item No 5.04 but copper conductor 4 sqmm.
12S & F in repair incl making existing surface good sheet metal enclosures with socket plug top and MCB's with two pin and earth plug and socket complete with one single pole MCB 240 V grade 20 Amp complete all as specified and directed by EIC.
13S & F in repair of modular switch single pole one way 6 Amps, 1 module ISI marked complete all as specified and directed by EIC.
14S & F in repair of modular socket single pole one way 6 Amp-2/3 pin, 2 module ISI marked complete all as specified and directed by EIC.
15S & F in repair of modular switch single pole one way 16 Amps, 1 module ISI marked complete all as specified and directed by Engr-in-charge.
16S & F in repair of modular socket single pole one way 16 Amp-2/3 PIN, 2 module ISI marked complete all as specified and directed by Engr-in-charge.
17S & F in repair of Modular Bell Push 6 Amps, 1 module ISI marked complete all as specified and directed by EIC.
18S & F in repair of modular switch single pole two way 5 Amps ISI marked complete all as directed by EIC.
19S & F in repair of switch piano type single pole one way 5 Amps, ISI marked complete all as directed by EIC.
20S & F in repair of socket outlet 5 pin flush 6 Amp multi pin 2/3 pin complete all as directed by EIC.
21S & F in repair of switch socket combined outlet 6 pin flush 16 Amp multi, ISI marked complete all as directed by EIC.
22S & F in repair of switch piano type/flush button type single pole two way 5 Amps front operated ISI marked complete all as directed by EIC.
23S & F in repair of bell push flush type SP 5 Amp complete all as specified and directed by EIC.
24S & F in repair of call bell Ding Dong ISI marked complete all as specified and directed by EIC.
25S & F in repair of lamp holder , PVC/Poly carbonate type with back plate suitable for fittings complete all as directed by EIC.
26S & F in repair of 3 pin plug top AC-230V, 6 Amp complete all as directed by EIC.
27S & F in repair of 3 pin plug top AC-230V, 16 Amp complete all as directed by EIC.
28S&F in repair ceiling rose, 3 phase/PVC/Polycarbonate, isolated body complete all as specified and directed by EIC..
29S & F in repair of High lam sheet cover ISI marked with required Nos of space for switches/ Sockets/ Regulator of size 250x280mm complete all as directed by EIC.
30S & F inverter type LED bulb 12 watt incl taking down old bulbs any type with very high efficiency suited for installation in existing lamp holders, complete all as as directed by EIC.
31S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 200 mm complete all specified and directed by EIC.
32S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 150 mm complete all specified and directed by EIC.
33M & L Submain wiring with three run single core 10 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 volts grade in concealed New PVC conduit 25 mm dia ISI marked alongwith one run of 10 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main DB and testing on completion etc complete all as directed. Note: Three runs of 10 sqmm cable and one run of PVC conduit shall be measured as one RM.
34M & L Submain wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 volts grade in concealed New PVC conduit 25mm dia ISI marked alongwith one run of 6 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main DB and testing on completion etc complete all as directed. Note: Two runs of 6 sqmm cable and one run of PVC conduit shall be measured as one RM.
35M&L for sub main wiring with two run of 4 sqmm size PVC insulated multi stranded copper conductor fire retardanr cable (Nominal area) and one run of 4 sqmm size PVC insulated unsheathed solid core copper conductor cable drawn in either existing or new surface/ recessed steel/ PVC conduit/ PVC casing capping of required size complete all as directed by EIC. Note: Two runs of 6 sqmm cable and one run of PVC conduit/casing-capping shall be measured as one RM.
36Material & Labour for sub main wiring with two run of 2.5 sqmm size PVC insulated multi stranded copper conductor fire retardanr cable (Nominal area) and one run of 2.5 sqmm size PVC insulated unsheathed solid core copper conductor cable drawn in either existing or new surface/ recessed steel/ PVC conduit/ PVC casing capping of required size complete all as directed by EIC. Note: Two runs of 6 sqmm cable and one run of PVC conduit/casing-capping shall be measured as one RM.
37M & L for PVC insulated aluminium service cable un-armoured 2.5 sqmm 2 core with ISI marked complete all as specified and directed by EIC.
38S & F in replacement Recess/surface mounting as suitable in existing fitting ultra slim 36 W LED 2x2 edge-lit tile in Aluminium Extruded housing with full opal diffuser suitable for perfect lighting conditions for most varied visual tasks in offices and general areas complete all as specified and directed.
39S & F in replacement 12 W LED Recess/surface mounted downlighter (squrae/round shape) with pressure die-cast aluminium heat sink & PC diffuser in white powder coated finish with integrated driver complete all as directed by EIC.
40S & F in replacement 15 W LED Recess/surface mounted downlighter (squrae/round shape) with pressure die-cast aluminium heat sink & PC diffuser in white powder coated finish with integrated driver complete all as directed by EIC.
41S & F in replacement 18W LED Recess/surface mounted downlighter (squrae/round shape) with pressure die-cast aluminium heat sink & PC diffuser in white powder coated finish with integrated driver complete all as directed by EIC.
42S & F in replacement 20 W LED Recess/surface mounted downlighter (squrae/round shape) with pressure die-cast aluminium heat sink & PC diffuser in white powder coated finish with integrated driver complete all as directed by EIC.
43S & F LED Bollard light 9 watt, with aluminium die cast housing and polymer diffuser, 765 lm, lunaire efficacy 85 lm/W, CRI>70, burning hour 50000 hr, class-1, operating voltage 140V to 270V AC, 50 Hz, PF>0.9, THD<15%, surge protection 4kV, IP 66 protection, wired with inbuilt driver, 2 year replacement warranty complete all as specified and directed by EIC.
44S & F in replacement LED batten luminaire surface/wall mounted ,4 feet 20 Watts comprise of aluminium extruded with anodised with powder coated in white colour with decorative end cap. The luminare is pre-wired with high efficiency electronic driver, with lifetime of 50000 burning hours . CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6000 to 6500K, surge protection DM-4KV & CM-3KV, IP-40 protected, meets LED IS specifications, Class -1, Short circuit and over circuit protection, voltage range - 140 to 300 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 120 lm/w, filiker free and including connecting up with PVC sheathed suitable size copper conductor with push type cable connector 2/3 pin cable connector from ceiling rose to fitting fixed with 2 years of replacement warranty on fittings complete all as specified and directed by EIC.
45S & F in replacement LED batten luminaire surface/wall mounted, 2 feet 10 Watts comprise of aluminium extruded with anodised thermally conductive material with powder coated in white colour with decorative end cap. The luminare is pre wired with high efficacy electronic driver, with lifetime of 50000 burning hours . CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6000 to 6500K, surge protection DM-4KV & CM-3KV, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 140 to 300 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 120 lm/w, filiker free and including connecting up with PVC sheathed suitable size copper conductor with push type cable connector 2/3 pin cable connector from ceiling rose to fitting fixed with 2 years of replacement warranty on fittings complete all as specified and directed by EIC.
46S&F 30 W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie should more than 110lm/W. The color temperature is 6000 to 6500 K with a color rendering index of 70. The luminaire is IP:66 protected/weather proof/ water resistant. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<10%, High and low protection along with a surge protection of 4 KV including provision of suitable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed by EIC.
47S&F in replacement of new genration post top lanterns, IP-66 elegantly designed spun alumnium and high grade aluminium heat sink for efficient thermal management, sturdiness and excellent corrosion resistance. MS base provided to support the housing, environmental friendly long life high power LED light 25 watt complete all as directed by EIC .
48S and F in repair incl taking down Ultra Bright LED Pl-L white/warm white, 4 pin with very high efficiency suited for installation in existing 2G11 lamp holders, complete all as specified and directed by EIC.
49S&F in repair of VTPN MCCB DB 4 way, with 200 A rated bus bar, double door with 100 Amp,25 KA,4P MCCB as incomer and cement spill protector (Vertical type double door,100 Amps MCCB rate inclusive) 150 Amp rated bus-bar and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 protection ISI marked including wooden rectangle board of first quality of suitable size for mounting of DB box with provision for 4 Pole MCCB* as incomer and SP/TP MCB's as outgoings complete all as specified and directed by EIC. Note: - Contractor must provides IP43 certificate.
50S&F in repair of TPN DB 8 way, with 200 A rated bus bar, acrylic double door with 63 Amp,25 KA,TPN MCB as incomer and cement spill protector(Vertical type double door, TPN 63 A MCB rate inclusive) 200 Amp rated bus-bar and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 protection, ISI marked including wooden rectangle board of first quality of suitable size for mounting of DB box with provision for 4 Pole MCB* as incomer and SP/TP MCB's as outgoingscomplete all as specified and directed by EIC. Note: - Contractor must provides IP43 certificate.
51S&F in repair of SPN DB 8 way with 200 Amp rated bus bar, IP 43, ISI marked acrylic double door complete all as directed by EIC. Note: - Contractor must provides IP43 certificate.
52S&F in repair of SPN DB 12 way with 200 Amp rated bus bar, IP 43, ISI marked acrylic double door complete all as directed by EIC. Note: - Contractor must provides IP43 certificate.
53S&F in repair of SPN DB 16 way with 200 Amp rated bus bar, IP 43, ISI marked acrylic double door complete all as directed by EIC. Note: - Contractor must provides IP43 certificate.
54S & F in repair MCB SPN 32-40 A 240 V 10 KA 'B' curve and connection with suitable thimbles testing and commissioing complete all as specified and directed by EIC
55S & F in repair of MCB TPN 40 to 63 A, 415 V with thimble suitable for existing wires complete all as directed by EIC.
56S & F in repair MCB SP 6-32 A 240 V 10 KA 'B' curve and connection with suitable thimbles testing and commissioing complete all as specified and directed by EIC
57S & F in repair 100 A MCCB 4 pole, 16 kA breaking capacity, 415 V ( Ics=100% Icu ) with suitable thimbles all as specified and directed by EIC
58S & F in repair 63 A MCCB 4 pole, 16 kA breaking capacity, 415 V (Ics=100% Icu ) with suitable thimbles all as specified and directed by EIC
59Supply installation, testing and commissioning of inverter compatible with 180 Ah, 12 V battery ISI marked alongwith canopy for closing of battery complete all as specified and directed by EIC.
60M&L earthing complete with GI electrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earth plate not less than 1.50 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze of sixe 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil incl 15 mm GI tubing medium grade and necessary fitting for protection of earth lead incl laying of charcoal dust and common salt, precast PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MS angle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia Med grade GI pipe for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed by EIC
61Taking down ceiling fan/Exhaust fans/Wall mounting fan of any cap/sweep after disconnecting the electric supply from any site and opening fans for repair/over hauling including removing dust and greasing, and cleaning of blades and fan with kerosene oil and checking of alignment of shaft, oiling including re-assembling, nut bolt checking and connecting/refixing of fans in its original position burnt out fan shall be kept separately for rewinding complete all as specified and directed by EIC.NOTE: Rewinding and replacement of defective parts shall be measured and paid seperately.
62M & L,Rewinding ceiling fan of sweep 1200 mm/1400 mm with suitable gauge copper winding wire (super enamelled) including all insulating material after necessary heat varnishing testing etc. complete all as specified and directed by EIC.
63M & L,Rewinding Exhaust fan of sweep 250/300 mm with suitable gauge copper winding wire (super enamelled) including all insulating material after necessary heat varnishing testing etc. complete all as specified and directed by EIC.
64M & L,Rewinding Exhaust/wall mounting fan of sweep 380/450/600 mm with suitable gauge copper winding wire (super enamelled) including all insulating material after necessary heat varnishing testing etc. complete all as specified and directed by EIC.
65M & L for painting of following Item with two coats of DUCO paint (ISI grade) white using spray machine spray painting including cleaning, washing and preparation of old painted surfaces including MES Nos are Entered in all ceiling and Exhaust fan in site only, complete all as directed by EIC:-Note:- (painting shall be carried out in E/M Yard)
66Ceiling fan upto 1200/1400 mm sweep complete.
67Exhaust/wall mounting fan upto 300 to 600 mm sweep with smoke grey.
68Geyser 25/50 liter cap.
69S & F in repair metal fan blade with frame of 250 to 450 mm sweep suitable for exhaust fan of any make & model, complete all as specified and directed by EIC.
70S & F in repair of ceiling fan regulator stepped type 2 module ISI marked, complete all as specified and directed by EIC
71S & F in repair of ceilling fan down rod of size 15mm GI pipe medium grade (ISI marked) length upto 50 cm including making holes, nut bolts, spilit pin washers etc complete all as specified and directed by EIC..
72Taking out and replacement of following accessories form ceiling fans taking down vide item No 55.00 here in before complete all as specified and directed by EIC.
73Bearing No 6201
74Bearing No 6202
75Bearing No 6203
76Condenser 2.5 mfd
77Condenser 4 mfd
78Ceiling fan shaft
79Ceiling fan clamps
80Rubber Bush , nut, bolts ,washer and split pin etc as reqd at site suitable for ceiling fan
81Ceiling fan canopy for suitable of 1200/1400 mm sweep complete
82M & L for fixing of geyser in existing or new position by providing suitable size of anchor fastner and connecting PVC connection with steel reinforced pipe for hot & cold water complete all as specified and directed by EIC.
83M&L for repairs to defective/leakage of geyser 25/50 ltr capacity inner tank of copper/Steel by brazing, soldering, gas welding including testing for leak proof upto the satisfaction of the EIC, complete all as specified and directed by EIC.
84S&F in repair of gun metal half turn UPVC gate valve of 25 mm dia and fixed in position after taking out u/s gate valve complete all as specified and directed by EIC.
85S&F in repair gun metal half turn UPVC gate valve of 20mm dia and fixed in position after taking out u/s gate valve complete all as specified and directed by EIC.
86Taking down and dismantling the outer cover of geyser of any capacity and removing the scaling including repairing and replacement of the inlet and out let pipe and re-assembling the same after testing complete all as specified and directed by EIC.
87Taking out and repalcement of following u/s parts of Geyser :-
88Inner tank stainless steel 25 ltrs cap ISI marked
89Thermostat ISI marked
90Triangle heating element 1.5 KW/2 KW, ISI marke or as per site requirement.
91Indicator lamp with flexibe copper wire of suitable size Red/Green
92PVC connection with steel reinforced pipe for hot water connection of Size 18\\" x 1/2\\"
93S & F in replacement of PVC insulated multi-stranded copper conductor, sheathed round cable ISI marked 1.5 sqmm x 3 core complete all as specified and directed by EIC. Please Enable Macros to View BoQ information
94S & F in replacement of PVC insulated multi-stranded copper conductor, sheathed round cable ISI marked 1.5 sqmm x 3 core complete all as specified and directed by EIC. Please Enable Macros to View BoQ information

Other Detail

Information Source https://defproc.gov.in/nicgep/app
Download FileName File Description File Size
Download 551362bb-4ec2-4960-92a7-7acbc8afc288.html Tender Documents 0 KB
Download BOQ_852535.xls Tender Documents 0 KB
Download GPSC_8984.pdf Tender Documents 0 KB
Download PS_8984.pdf Tender Documents 0 KB
Download SOC_8984.pdf Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Download WORKLOADNEW.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.