Tender For Civil, Electrical And Supply Of Capital Items--Civil Works Providing And Laying Autoclaved Aerated Concrete (Aac) Blocks Masonry 150Mm/230Mm/300 Mm Thick With Grade-I Aac Blocks In Super Structure Above Plinth Level Up To Floor V Level With Rcc Band At Sill Level And Lintel Level With Approved Block Laying Polymer Modified Adhesive Mortar All Complete As Per Direction Of Engineer-In-Charge. (The Payment Of Rcc Band And Reinforcement Shall Be Made For Seperately). Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering. Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement: 1.5 Coarse Sand (Zone Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo Mechanically Treated Bars Of Grade Fe-500D Or More 12 Mm Cement Plaster Of Mix: 1:4 (1 Cement: 4 Fine Sand) Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. Wall Painting With Premium Acrylic Emulsion Paint Of Interior Grade, Having Voc (Volatile Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour. Two Coats Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade: One Or More Coats On Old Work Providing And Fixing Partition Upto Ceiling Height Consisting Of G.L. Frame And Required Board, Including Providing And Fixing Of Frame Work Made Of Special Section Power Pressed/ Roll Form G.I. Sheet With Zinc Coating Of 120 Gms/Sqm(Both Side Inclusive), Consisting Of Floor And Ceiling Channel 50Mm Wide Having Equal Flanges Of 32 Mm And 0.50 Mm Thick, Fixed To The Floor And Ceiling At The Spacing Of 610 Mm Centre To Centre With Dash Fastener Of 12.5 Mm Dia Meter 50 Mm Length Or Suitable Anchor Fastener Or Metal Screws With Nylon Plugs And The Studs 48 Mm Wide Having One Flange Of 34 Mm And Other Flange 36 Mm And 0.50 Mm Thick Fixed Vertically Within Flanges Of Floor And Ceiling Channel And Placed At A Spacing Of 610 Mm Centre To Centre By 6 Mm Dia Bolts And Nuts, Including Fixing Of Studs Along Both Ends Of Partition Fixed Flush To Wall With Suitable Anchor Fastener Or Metal Screws With Nylon Plugs At Spacing Of 450 Mm Centre To Centre, And Fixing Of Boards To Both Side Of Frame Work By 25 Mm Long Dry Wall Screws On Studs, Floor And Ceiling Channels At The Spacing Of 300 Mm Centre To Centre. The Boards Are To Be Fixed To The Frame Work With Joints Staggered To Avoid Through Cracks, M.S. Fixing Channel Of 99 Mm Width (0.9) Mm Thick Having Two Flanges Of 9.5 Mm Each) To Be Provided At The Horizontal Joints Of Two Boards, Fixed To The Studs Using Metal To Metal Flat Head Screws, Including Jointing And Finishing To A Flush Finish With Recommended Jointing Compound, Jointing Tape, Angle Beads At Comers (25 Mm X 25 Mm X 0.5 Mm), Joint Finisher And Two Coats Of Primer Suitable For Board As Per ManufactureS Specification And Direction Of Engineer In Charge All Complete. 66Mm Overall Thickness Partition Using 8Mm Thick Double Skin Multipurpose Cement Board Reinforced With Cellulose Fibre Manufactured Through Autoclaving Process (High Pressure Steam Cured) As Per Is: 14862 With Suitable Fibre Cement Screws Providing And Fixing Fiber Glass Reinforced Plastic (Frp) Door Frames Of Cross-Section 90 Mm X 45 Mm Having Single Rebate Of 32 Mm X 15 Mm To Receive Shutter Of 30 Mm Thickness. The Laminated Shall Be Moulded With Fire Resistant Grade Munsaturated Polyester Resin And Chopped Mat. Door Frame Laminate Shall Be 2 Mm Thick And Shall Be Filled With Suitable Wooden Block In All The Three Legs. The Frame Shall Be Covered With Fiber Glass From All Sides. M.S. Stay Shall Be Provided At The Bottom To Steady The Frame. Providing And Fixing To Existing Door Frames.30 Mm Thick Fiberglass Reinforced Plastic (F.R.P) Flush Door Shutter In Different Plain And Wood Finish Made With Fire Retardant Grade Unsaturated Polyester Resin, Moulded To 3 Mm Thick Frp Laminate All Around, With Suitable Wooden Blocks Inside At Required Places For Fixing Of Fittings And Polyurethane Foam (Puf)/Polystyrene Foam To Be Used All Filler Material Throughout The Hollow Panel, Casted Monoolithically With Testing Parameters Of F.R.P. Laminate Conforming To Table-3 Of 15: 14856, Complete As Per Direction Of Engineer-In-Charge. Providing And Fixing 12 Mm Thick Frameless Toughened Glass Door Shutter Of Approved Brand And Manufacture, Including Providing And Fixing Top & Bottom Pivot & Double Acting Hydraulic Floor Spring Type Fixing Arrangement And Making Necessary Holes Etc. For Fixing Required Door Fittings, All Complete As Per Direction Of Engineer-In-Charge (Door Handle, Lock And Stopper Etc To Be Paid Separately) Providing And Fixing Of Glass Door Ss Patch Lock With Out Handle In Toughened Glass Door Including All Necessary Screws Etc. Complete Providing And Fixing Ss H Handle Having Min 30Cm Length In Toughed Glass Door Including All Necessary Screws Etc. Complete Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is: 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete.
|