Indian Tenders

Tender Notice

TDR 55135065
Tendering Authority Jammu And Kashmir State Sports Council
Tender No E NIT NO 02 OF 2026-27 DATED 17.04.2026
Tender ID 2026_SPORT_308096_1
Tender Brief Corrigendum : Tender For Flood Restoration And Reconstruction Of Indoor Hall At Samba And Billawar.
City Samba
State Jammu And Kashmir
Document Fees INR 6000 /-
EMD INR 485540.0 /-
Tender Value INR 2.42 Crore /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Flood Restoration And Reconstruction Of Indoor Hall At Samba And Billawar.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 09-05-2026 REGARDING DATES 3 Date 12-05-2026
2 05-05-2026 REGARDING DATES 2ND Date 08-05-2026
3 05-05-2026 REGARDING DATES 2ND Date 08-05-2026
4 02-05-2026 REGARDING DATES Date 05-05-2026
5 02-05-2026 REGARDING DATES Date 05-05-2026
6 02-05-2026 REGARDING DATES Date 05-05-2026

Key Dates

Publish Date 09-05-2026
Last Date of Bid Submission 12-05-2026
Tender Opening Date 13-05-2026

Contact Information

Company Name Jammu And Kashmir State Sports Council
Contact Person Ex Engineer
Address EX ENGINEER OFFICE AT SPORTS HOUSE MA STADIUM

BOQ Items

Name of Work:- Flood Restoration and Reconstruction of Indoor Hall at Samba and Billawar.
Sl. No. Item Description
1Earth work in excavation by mechanical means in trenches for foundations, drains, pipes, cables etc. (Not exceeding 1.5 mtr in width) and for shafts, wells, cesspits and thelike not exceeding 10sqm on plan, depth upto 1.5mtr.including disposal of excavated earth upto 1 mtr fromcutting edge, disposed earth is to be levelled and neatly dressed in All kinds of soil complete job.
2Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil
3Slip Clearance In ordinary soils disposal lead upto 50 m and lift upto 1.5 m.
4Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 meters lead
5Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering . All works upto plinth level 1:4:8 mix (1 cement: 4 coarse sand:8 graded stone aggregates) 40 mm nominal size (crushed)
6Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering.All works upto plinth level in 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size) crushed
7Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level using 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
8Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
9Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns complete job.
10Centering and shuttering including strutting, propping etc. and removal of form work for Lintel, beams, plinth beams, girders, bressumers and cantilevers
11Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat ofapproved steel primer all complete. Welded
12Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-incharge Made of G.I. wire of dia 4 mm complete job.
13Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm)
14Applying priming coat With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel galvanized iron/steel works
15Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work complete job.
16Providing and laying of Gabion of mechanically woven, double twisted hexagonal wire mesh Gabion Type: Zinc coated mesh type 120 mm x 100mm, woven diagionally. Mesh wire dia 2.70, salvage wire dia 3.40 mm lacing wire dia 2.20 mm of GI wire including all leads lifts and carriages and cost of Stone and Gabion wire crates. The gabions shall have partions made of same material and each compartment shall be of size 1.2m x 1.00m
17Excavating, supplying and filling of local earth (including royalty)by mechanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete including carriage.
18Filling of good earth including diging, loading, unloading, royality, carriage & spreading in proper lines and grades and consolidation with power road roller complete.
19Providing & laying PP (polypropylene ) tile approved by FIBA with minimum thickness of 15.5 mm and weight not less than 320 gm/ tile and other specification like Ball Rebound, slip resistance, force reduction as per parameters approved by FIBA. The contractor shall have to provide the unconditional warrenty of 5 years from the OEM or its Authorised Distributor in India and get the sample of tile Tested from NABL Accrediated before payment
20P/F of Torchshield Bituminious water proofing membranes (five layer in build system) including bituminous primer, labour etc all complete job (2mm thick) as per direction engineer in charge
21Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete
22Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
23Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge.
24Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
25Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 meters lead of : G.S. Sheet
26Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gram/m2
27Providing and fixing aluminium work for doors, windows, ventilatior and partion with extruded built up standard tubular section,Z section and other sections of approved make and ISI 1285, fixed with dash fasteners of required dia and size including necessary filling up the gaps at the junction i.e.0top, bottom and sides with required EPDM rubber I neoprene gasket felt etc. Aluminium section shall be smooth,rust free, straight,mitred and jointed mechanical wherever required including cleat angle, aluminium snap beading for l panelling,C.P.brass stainless steel screws,all complete,For fixed portion . Powder coated aluminium.
28For shutters of doors, windows & ventilators including providing and fixing hinges l pivot and making provision and fixing of fittings wherever required including the cost of EPDM rubber gasket required.
29P/F of (3.5 to 4mm)thick ACP sheet including all fittings complete job .
30Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin- charge. (Cost of aluminum snap beading shall be paid in basic item.) With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm)
31Renewing glass panes, with wooden fillets wherever necessary Float glass panes of thickness 5.0 mm (weight not less than 12.5kg/sqm)
32Providing and fixing hardware fixtures (Aluminium) ISI marked anodised (Anodic coating) not less than grade AC 10 as per IS-1868 tower bolt200x10mm
33Providing and fixing hardware fixtures (Aluminium) ISI marked anodised (Anodic coating) not less than grade AC 10 as per IS-1868 tower bolt150x10mm
34Providing and fixing hardware fixtures (Aluminium) ISI marked anodised (Anodic coating) not less than grade AC 10 as per IS-1868 handle 125mm
35Providing and fixing hardware fixtures (Aluminium) ISI marked anodised (Anodic coating) not less than grade AC 10 as per IS-1868 handle100mm
36Labour engaged for removing of solar panels from roof top and refixing again after p/f of roof sheets all complete job as per direction engineer in charge 5 labour for 10 days
37Providing and Installation of MAPLE WOOD SPORTS FLOORONG as per specifications laid under:-1. Vapour Barrier- 0.20 mm thich Polyethylene memberane installed over the concrete base beneath flooring with joints lapped @ 150 mm. 2. Cushion Pads- 19 mm thick cushion pads placed under the wooden sleepers for extra resilience, stapled through the two wings at 300 mm x 300 mm3. Pine/Fir Wood Sleepers - The under frame made of commercial qualityPINE WOOD runners of 70 mm wide x 45 mm thick, treated with anti-termite solution and installed @ 305 mm centre to centre.4. Maple Flooring – 21 mm Thick with width varying from 57 to 83 mm jointed togeather with Tongue & Groove on all 4 sides on all boards, kiln dried and treated with anti-termites and water resistant lacquer.5. The surface board to be nailed with Pressure machine to the runner through the tongue only. The floor should be machine sanded and finished with WATER BASED POLYURETHANE POLISH. The Product Should be BWF/FIBA approved, shall be of USA/ European Countries Origin only, with warrenty of 5 years and shall be installed after prior approval of Engineer Incharge.
38P/F of pvc yonex badminton mat ,Length of Mat 15.4 meter Width of Mat 7.1 mete & thickness 4.5mm. Marking of Court Lines at top surface of Mat approved As per BWF ( Badminton WORLD Federation) Rules
39Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Gutter .(600 mm over all girth
40Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.110 mm diametre
41Supply and fixing of HDPE Spectators chairs with following chairs with following specification:- 1) seat dimension = 415mmx450mmx700mm (from ground ) with minimum 3mm and maximum 8mm wall thickness all over the profile .2) seat shell should be blow moulded high polyethylene with uv protection dual wall with air gaps gives comfort and softness while seating on the seat with molded insert M6 threaded nut to mount on the stand & water drain hole of dia 20mm.3) Mounting beam shall consist of 2 steel pipes of OD 34 & ID 28 mm 3 mm wall thickness with hot dip galvanizing to prevent from crossion in open air running across the length of desired length of seating .4) Mounting bracket =MS 203x40mm 3mm thickness metal embosed bracket inter locked by bolt and nut with pipe and bracket size 110x35mm with 3mm thick embosed bracket with hot dip galvanising to prevent from crossion in open air.5) Leg type =Floor mounted aluminium die casted (ADC12) Stand of 335x240mm for strong leg support with powder coated 50micron thickness 6)Mounting dimension =CTC can be managed with the mounting brackets on pipe to mount in different sizes which gives flexibilty of mounting CTC(minimum 420mm & maximum depending as per required space between 2 seats)
42Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm widex1.6mm thick with flanges of 27mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x40mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.5mm of required length with nuts & bolts of required size and other end of angle hanger fixed with G.I. channels 45x15x0.9 mm running at the spacing of 1200 centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5 mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diaX230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre to centre, with 25mm long drive-all screws @ 230 mm interval ,including fixing of gypsum board/calcium silicate board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the gypsum board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coats of primer suitable for board, ll as per manufacturers’ specification and also including the cost of making openings for light fittings, grills diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer-in-Charge but excluding the cost of painting with: 12.5 mm thick tapered edge gypsum moisture resistant board
43Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
44Finishing walls with premium Acrylic smooth exterior paint with silicon additives of required shade: Old work (Two or more coats applied @ 1.43 liters/ 10 sqm) over existing cement paint surface.
45Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.15mm nominal outer dia pipes.
46Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, withall fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid.
47Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap.
48Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
49Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265mm sizes respectively.
50Providing and fixing PTMT grating of approved quality and colour 100 mm nominal dia.
51Providing and fixing PTMT soap dish holder having length of 138mm, breadth 1 02mm, heigth of 75mm with concealed fitting arrangements, weighing not less than 106gms
52Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour:600 mm long towel rail with total length of 645 mm, 78 mm wide and effective height of 88 mm, weighing not less than 190 gms.s
53Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931
54Providing and fixing bib cock of approved quality. 15 mm nominal bore
55Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm
56Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-Charge and finished smooth. 16/18 mm Granite Stone of approved shade
57Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
58Carriage of material from source to site of work by M.T including loading & unloading complete For sand and aggregate
59P/F of 300mm exhaust fan of havells or eqvt. Make incl. testing , commission complete .
60P/F of 4feet led tube light incl. testing , commission complete .
61Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die castaluminium body with built in or separate driver asper the requirement with Driver efficiency >85%,Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as perIEC 61000-4-5, Driver efficiency >85%,THD < 10%as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection,EMI-EMC as per CISPR -15, lenses for beamangle 30 deg-120deg as per the application and theproject requirement., suitable tilt able fitting, life time(LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumenmaintained till life ends as per LM80extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin) ,SDCM(Standard Deviation Color Matching) <5,Maximum power consumption should not morethan the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/cexternal connections with 1.5 sq mmFRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumenefficacy ≥105 <120 lm/Watt output .LM79 & LM80Test report and all testing required for LEDfixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LEDjunction temperature shall not rise above 90°C).
62Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
63Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
64Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch
65Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
66Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet
67Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
68Supplying and fixing 63 amp SPN rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
69Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amp
70Supply, Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. light Bulb 9 watt
71Installation testing and comissioning of 2X2 Recessed luminaire with LED (Light Emitting Diode) maximum system power: 36 W, minimum Luminous flux of luminaire 100 Lm/w, Colour temperature of 0 K, Neutral white, CRI > 80, R9>0, THD<5%, P.F>0.95, Driver Efficiency>88%, SDCM<3, 230 V constant current driver, 70% of luminous flux after 50,000 operating hours; Energy efficient LEDs, Direct light emission, 1.4 mm thick extruded aluminium profile with Polyester powder white coloured coat applied over a 5- stage pre-treatment, Protruded Prismatic diffuser for glare-free uniform illumination, UGR<16, ZHLS (ZERO HALOGEN LOW SMOKE) internal wiring, Electronic control gear, Protection class I, IP 40
72Installation testing and comissioning of linear surface wall mounted 20 watt light luminaire with Luminous efficiency of luminaire 100 lm/W; color rendering index Ra > 80; minimum system lumen output of 4000 lumens and maximum system wattage of 12W; Dimension :- 595 mm Body of extruded aluminium profile and polycarbonate cover.
73Installation testing and comissioning of linear surface wall mounted 36 watt light luminaire with Luminous efficiency of luminaire 100 lm/W; color rendering index Ra > 80; minimum system lumen output of 4000 lumens and maximum system wattage of 12W; Dimension :- 1200 mm Body of extruded aluminium profile and polycarbonate cover.
74Installation, testing and commissioning of 200 mm sweep exhaust fan with robust motor, gravity shutters with speed rating of 1350 revolution per minute complete with all accessories etc. directly on ventilator , including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
75Supplying, installation, testing and commissioning of 2.0 Ton Inverter type Split AC's (copper) (3 star) Hot/ Cold (all weather) type of minimum capacity following sizes as detailed below. Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. Repairs made to wall whereever required. Warrantee.:- a). Warrantee shall be provided for 12 month from the date of installations. b). The compressor shall be warranted for 5 years from the date of installation.
76Fixing for available Structural steel such as tees, angles, channels and R.S. joists at site
77Supplying, Installation, Testing & Commissioning of following capacity automatic voltage stabilzer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary. Warrantee.:- 2 Years from the date of installation. 5 KVA Please Enable Macros to View BoQ information

Other Detail

Information Source https://jktenders.gov.in
Download FileName File Description File Size
Download 97f5877e-c868-4e66-8d61-b71fac77c78e.html Tender Documents 0 KB
Download BOQ_998839.xls Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.