Tender Brief Corrigendum : Tender For Structural Repair Work In Medical Room , Visitors Room,Gallery & Basement , Staircase Of Ughg , Dhaka Complex, Mukherjee Nagar, University Of Delhi
City Delhi
State Delhi
Document Fees INR 500 /-
EMD INR 19794.0 /-
Tender Value INR 9.89 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Structural Repair Work In Medical Room , Visitors Room,Gallery & Basement , Staircase Of Ughg , Dhaka Complex, Mukherjee Nagar, University Of Delhi

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 05-05-2026 Structural repair and finishing work in Medical room , Visitors Room, Gallery and Basement , staircase of UGHG , Dhaka Complex, Mukherjee Nagar, University of Delhi Date 08-05-2026

Key Dates

Publish Date 05-05-2026
Last Date of Bid Submission 08-05-2026
Tender Opening Date 11-05-2026

Contact Information

Company Name Delhi University
Contact Person Executive Engineer
Address 12, Cavalry Lane, Engineering Department, University of Delhi, Delhi-110007

BOQ Items

Name of Work:- Structural repair work in Medical room , Visitors Room,Gallery & Basement , staircase of UGHG , Dhaka Complex, Mukherjee Nagar, University of Delhi
Sl. No. Item Description
1Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more.
2Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform
3Centering and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth beams, girders, bressumers and cantilevers
4Centering and shuttering including strutting, propping etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts
5Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
66 mm cement Plaster of Mix : 1:3 (1 cement : 3 fine sand )
7Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work.
8Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
9Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on old work
10Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
11Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
12Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
1315 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand)
1415 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand)
15Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
16Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.
17Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge 25mm average thickness
1875 mm average thickness
1950 mm average thickness
2025 mm average thickness
21Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.
22Bars upto 12 mm diameter
23Bars above 12 mm diameter
24Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using Hilti RE-500 V3 epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge. Upto and including 12mm dia.
25Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect, SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer.
26Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).
2725 mm average thickness in 2 layers.
2850 mm average thickness in 3 layers.
29Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of \\"L\\" shaped mild steel of weight not less than 7.75 kg/m2 shear key welded with existing reinforcement and anchoring in concrete including drilling and fixing in position including the cost of materials, labour, tool & plants as approved by Engineer-in-charge.
30Supplying and applying approved primer bonding coat on TMT reinforcement bars of specified make, complete in all respects, in accordance with the directions of the Engineer-in-Charge.
31Providing and laying of Micro Concrete M-40 grade or equivalent material blended with washed, saturated surface-dry (SSD), graded, low absorption, high density aggregates of size 8 mm & below up to 20% by weight of micro-concrete and water at 4 lit. per 25 kg bag and pouring into the form work using suitable pumping device for uniform flow of concrete. The side shuttering can be removed after 3 days and the bottom shuttering after 7 days ensuring proper bond between the micro concrete and existing concrete substrate. Item rate inclusive of all materials, labours, supervision, tools, tackles, transportation, curing, etc., complete as per specification and as directed. Formwork will be paid separately on the basis of item of formwork. Make: Dr. Fixit Micro-concrete / Fosroc- Rederoc-RG or equivalent as approved by Engineer-in-charge. (Rates including cube sample test reports from recognised testing laboratory) Please Enable Macros to View BoQ information

Other Detail

Information Source https://eprocure.gov.in/eprocure/app
Download FileName File Description File Size
Download BOQ_951833.xls Tender Documents 0 KB
Download fbb85dda-90ed-412b-9288-6b3876687e4f.html Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.