Tender Brief Corrigendum : Tender For Survey, Soil Investigation, Design And Supply Of All Materials, Labour, T&P Etc. Required For Construction Of Tubewells, Pump Houses, Over Head Tanks, C.W.R., Rising Main, Distribution System, Building Works, Boundary Wall, Gates, Site Dev
City Hapur
State Uttar Pradesh
Document Fees INR 23600 /-
EMD INR 10937000.0 /-
Tender Value INR 109.36 Crore /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for Survey, Soil Investigation, Design And Supply Of All Materials, Labour, T&P Etc. Required For Construction Of Tubewells, Pump Houses, Over Head Tanks, C.W.R., Rising Main, Distribution System, Building Works, Boundary Wall, Gates, Site Development, Scada And Automation, Admin Building, Staff Quarters Etc. Complete In All Respect As Per Specifications In Tender Document Including Testing, Commissioning, Trial & Run, Defect Liability Period (One Year For Civil Works And Two Years For E&M Works) And Its Handing Over The Complete Works Of Nagar Palika Parishad Hapur Water Supply Reorganization Scheme (Part-1) With Its Appurtenant Works To Nagar Palika Parishad Hapur,District - Hapur (Uttar Pradesh).

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 04-05-2026 Pre Bid Meeting Minutes Other 14-05-2026

Key Dates

Publish Date 04-05-2026
Last Date of Bid Submission 14-05-2026

Contact Information

Company Name Uttar Pradesh Jal Nigam
Contact Person Superintending Engineer
Address Office of the Superintending Engineer, Construction Circle, UP Jal Nigam (Urban), Civil Lines, Meerut

BOQ Items

Name of Work:- Survey, Soil investigation, design and Supply of all materials, labour, T&P etc. required for Construction of Tubewells, Pump Houses, Over Head Tanks, C.W.R., Rising main, Distribution System, Building works, Boundary wall, Gates, Site Development, Scada and Automation, Admin Building, Staff Quarters etc. complete in all respect as per specifications in tender document including testing, commissioning, trial & run, defect liability period (one year for civil works and two years for E&M works) and its handing over the complete works of Nagar Palika Parishad Hapur Water supply reorganization scheme (Part-1) with its appurtenant works to Nagar Palika Parishad Hapur,District - Hapur (Uttar Pradesh).
Sl. No. Item Description
1SCHEDULE (G-1)
2RCC Overhead Tank
3Supply of all materials labour T&P etc. required for complete construction of R.C.C. Over Head Tank of following capacity and staging min 0.6 m above buildup ground level with main components, soil testing and ‐assuming bearing capacity of soil as 8 MT, including cost of survey and supply of design and drawings. All the water retaining components of OHT shall be casted in M 30 grade cement concrete and minimum grade of concrete‐ of foundation and staging should be M 25 with approved opc cement, coarse sand and stone grit as per I.S. 11682 and I.S.456 Seismic effects and wind load should be taken into consideration as per I.S. 1893 for earthquake resistance and I.S. 875 part III for wind load on structure and including 1M wide RCC staircase (Saperate two column based RCC staircase), 1 m wide R.C.C. M30 balcony, M.S. ladder made of 50x50x6 mm angle section and 20mm plain M.S. bars with hand rails of 20mm medium class G.I. pipes, One Stainless steel ladder inside the tank from top dome to bottom dome, railing with 20mm dia medium class G.I.pipe (in 3 rows) on both sides of stair case, supported on 50x50x6mm M.S. angle section, spaced at intervals not more than 1.5m, proper ventilator at top dome in circular shape of 1.2 m dia, Food Grade epoxy coating of FOSROC / Asian paints Triblock or reputed brand on inside surface area of water container after testing of water tightness, two coat of apex painting over one coat of primer of approved colour after finishing of RCC surface with grinder,
4Repairs of pin holes, unevenness of all concrete surface and steel pipe works, Ultra Sonic Water level indicator fabricated with sensor connecting to automation, Lightening conductor as per I.S.2309 or its latest amendments of latest electricity rules, consisting of proper elevation rod with 5 or more fork points as prescribed in ISS 2309 1969 and I.S. 3013 1966, C.I. /M.S. manhole of min 60x60cm size with locking arrangement.
5Supply, fixing, jointing of D.I.D/F Pipes of appropriate size with D.I.D/F specials conforming to IS 8329/2000 as vertical pipes for inlet/outlet , overflow and washout (as per approved design) with Bell Mouth as per latest / relevant I.S. specifications with all jointing materials for proper completion of work, Construction of 120mm thick RCC floor in 1:1.5:3 with cement, coarse sand, approved stone grit and reinforcemen‐t@8mm dia@250mm c/c both way over 100mm thick PCC 1:4:8 Construction of washout / overflow chamber and chambers for sluice / butter fly valves as per departmental type design and drawing, Supply of 200 mm dia PVC pipe as per I.S. 4985/2000 for disposal of water from overflow and washout chamber to suitable point outside the water works compound including necessory earth filling in campus, Gardening work with 2 nos Palm tree, landscaping work, installation of fountain in water works campus, watch & ward of all campus etc complete in all respect as per direction of Engineer-in-charge. including testing of bearing capacity of soil for various sites for proposed water works.
6Zone 5
72250 KL/24 m staging
8Zone 6
92250 KL/24 m staging
10Zone 9
112250 KL/24 m staging
12Zone 10B
131000 KL/22 m staging
14Zone 11
152100 KL/24 m staging
16Renovation of 7 Nos RCC Overhead Tanks (Zone1- 2250 KL/19 m, Zone 2- 800 KL/18 m, Zone 3- 2250 KL/19 m, Zone 4- 1650 KL/19 m, Zone 7- 1250 KL/19 m, Zone 8- 2250 KL/18 m , Zone 10A- 2250 KL/18 m) & 1No CWR 360 KL in Zone 10A
17Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineer- in-Charge
1825mm thick in Grade M 25 with cement content not less than 330 kg per cum
1950mm thick in Grade M 25 with cement content not less than 330 kg per cum
20Dismantling cement concrete floor of OHT including base concrete
2125 mm thick 1:2:4 plain cement concrete floor with cement,coarse sand and 20 mm gauge approved stone ballast laid in panel finished with 3 mm floating coat of neat cement and 7.5 cm thick base concrete consisting 1 part of cemnet,4 part of local sand and 8 part 1st class brick ballast 4 cm gauge (1:4:8) and removing any over lapping of mortar at the joist of panel if an and giving them uniform finished including supply material, labour,T&P etc required for proper compltion of work.
22R.C.C. work with cement, coarse sand and 20mm stone ballast 1:1.5:3 in floor of OHT excluding supply of reinforcement and its bending but including its fixing and binding the same with 0.50mm thick binding wire and including necessary centering and shuttering supply of all material, labour, T&P etc required for proper completion the work.
23M.S. or iron work in plain work in floor of OHT to provide minimum reinforcement brought to required shape as necessary including binding for proper completion of the work including supply of steel and its wastage.
24Supply and fixing 75x75x6mm M.S. angle iron ladder with 20mm dia round bar about 250mm c/c out side and inside of tank, including painting of new work with one coat priming and two coast of approved paint as per direction of engineer-in-charge
25Supply and fixing 50x50x6mm M.S. angle iron railing post including painting of new work with one coat priming and two coast of approved paint as per direction of engineer-in-charge
26Supply and fixing 20mm dia G.I. pipe with specials in railing including supply of all material, labour & T&P etc. complete for proper completion of the work
27Supply and fixing of M.S. main hole cover at top dome including grounting painting, supply of all materials, labour, T&P etc. complete.
28Providing & fixing fly proof Galvanised M.S. wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.
29Supply and fixing of lighting conductor of approved quality of copper/ GI strips (32 mm x 6 mm) from top to bottom of the tank as per ISI standard including supply of all materials, labour, T&P etc. complete.
30Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required. earthing materials such as pipe, wire/earthing plate including supply of all materials, labour, T&P etc. complete.
31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade Old work in Two coats over existing old RCC surface including supply of all material, labour, T&P etc. complete followed by Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
322250 KL/19 M OHT (Zone-1)
33800 KL/18 M OHT (Zone-2)
342250 KL/19 M OHT (Zone-3)
351650 KL/19 M OHT (Zone-4)
361250 KL/19 M OHT (Zone-7)
372250 KL/18 M OHT (Zone-8)
382250 KL/18 m staging also including C.W.R. 360 KL(Zone-10A)
39Providing necessary scafolding/shuttering for repairing work on O.H.T. surface form bottom to top dome & Stair case including supply of all material, labour etc. complete.
40Cleaning of Over Head R.C.C. Tank including disposal of silt and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:-(i) Tank shall be emptied of water & bottom shall be cleaned of silt and other deposits.(ii) Entire surface area of the OHT shall then scrubbed thoroughly with wire brush etc, and pressure washed with water.(iii) Chlorination of RCC internal surface by liquid chlorine. (iv)The treated surface shall be dried using air jetting and all loose paricles shall be removal from the surface.(v) Finally the surface shall be treated with ultraviolet radiation etc, as per direction of Engineer-in-charge.
41Construction of U type Drain 200mm x150mm including supply of all material, Labour and T&P etc. complete for proper completion of the work.
42Construction of Rectangular R.C.C Clear Water Reservoir cum Pump House of 600KL capacity in Zone-9 including Design & drawings, supply of all material, labour, T&P etc various works like 1 m wide staircase with stainless steel hand railing to go inside reservoir, sump below the pump house area, stainless steel railing (Min. wt @ 7.8 Kg/m) over the R.C.C. slab of Reservoir, Apex exterior paint finish on exterior surface of pump house, gantry beam, food grade epoxy coating of FOSROC/Ciba- Geigy/Asian paints Triblock or reputed brand on inside surface area of water container after testing for water tightness with suitable inlet and outlet arrangements and backfilling of campus, Campus development, plantation work etc. Also including testing of bearing capacity of soil with 03 Nos Bore Hole for for proposed C.W.R. 600K.L. capacity
43SCHEDULE (G-2&3)
44RISING MAIN & DISTRIBUTION SYSTEM
45Supply of following sizes of pipes including cost of pipes with cost of its Specials, FOR destination, all duties and insurance charges, cost of jointing materials, loading unloading, third party inspection charges, packing and forwarding charges, road transportation charges etc complete .
46D.I. Pipe K-9 conforming to IS 8329 / 2000 or its latest amendment
47150 mm dia
48200 mm dia
49350 mm dia
50D.I. Pipe K-7 conforming to IS 8329 / 2000 or its latest amendment
51200 mm dia
52250 mm dia
53300 mm dia
54350 mm dia
55400 mm dia
56450 mm dia
57HDPE Pipe PN 6 : class PE 100 as per I.S. code no. 4984 / 2016 or its latest amendment
58110 mm dia
59140mm dia
60160 mm dia
61Dismantling of following type of road surface either single or multiple layers (In case of multiple layers only top layer will be measured for payment) for laying of pipe line including sorting out of serviceable and unserviceable materials proper stacking of serviceable materials at suitable place and disposal of unserviceable materials at suitable place. Due to excavation, chowked drains are to be cleared also.
62Bituminous Road
63Cement Concrete Road
64Interlocking C.C. Tile Road
65B.O.E Road
66Excavation of earth in ordinary/hard soil (loam, clay, sand, kankar or any strata ) to give 1 mt. cover from top of the pipe including lift upto 1.5 mt. and lead from centre of trenches and refilling of earth in 20 cm. layers with watering and raimming etc. complete in all respect.
67Carting, laying & jointing following type of pipes and lowering the same into already prepared trenches and laying true to alignment and gradient, including all labour, T&P, supply & fixing of all HDPE / D.I./ CI specials conforming to latest / relevant IS specification as per requirement of site, loading and unloading, shifting of public utilities, interconnection with existing pipe line and seggregation of zone if any, also includes sectional pressure testing of pipe line , barricading for safety purpose etc. all complete as per direction of Engineer in charge.
68D.I. Pipe K-9
69150 mm dia
70200 mm dia
71350 mm dia
72D.I. Pipe K-7
73200 mm dia
74250 mm dia
75300 mm dia
76350 mm dia
77400 mm dia
78450 mm dia
79HDPE Pipe PN 6 : class PE 100
80110 mm dia
81140mm dia
82160 mm dia
83Supply, Carting to site of work, lowering, fixing and jointing of following sizes of fittings in trenches including FOR destinstion, all duties and insurance, cost of fittings, all jointing materials as per latest relevant IS Code, such as rubber packing, nut bolts any type of HDPE/D.I. specials etc. complete work as per direction of Engineer in charge.
84C.I. D/F Sluice Valve
85450mm dia
86400mm dia
87350mm Dia
88300mm dia
89250mm Dia
90200mm Dia
91150mm Dia
92125mm Dia
93100mm Dia
94Scour Valve
95100mm Dia
96Fire Hydrant ( as per latest IS specifications)
9780 mm dia (Sluice Valve Type)
98Air Valve Single/Double Ball type ( as per latest IS specifications)
9920 mm dia
100RCC thrust block in RCC 1:1.5:3 (1 part of cement, 1.5 parts coarse sand and 3 parts stone grit 10 to 20 mm ) including cost of material, shuttering, all labour T&P etc. complete work.
101M.S. or iron work in plain work such as R.C.C. work brought to required shape as necessary including bending for proper completion of the work including supply of steel and wastage.
102Supply of all materials and construction of following chambers as per type design of U.P. Jal Nigam (Urban) including supply of all labour, material, T&P etc. complete.
103Sluice/Scour Valve chambers (Surface Box Type)
104Sluice/Scour Valve chambers (Masonry Type)
105Fire Hydrant Chambers
106Air Valve Chambers
107Trenchless Laying of Pipe for Major Road crossing
108Supply of MS pipe (As per IS:3589 made from steel confirming to IS:2062), with anti corrosive treatment with P.U. coating and Installation of product pipe by HDD method including preparing and setting up the plants and equipement, preparing new pipe work material, installation new pipe-work and commissioning system or making the system ready for commissioning by HDD operation including, all related civil and mechanical works like excavation, shoring/strutting, etc. drilling, stringing, reaming, and pulling back the new pip-work on the designed bore path alignment, proper disposal of drilling fluid, and back fill of site after completion all inclusive as per I.S.101:2018: Code of prectice of HDD Technique Suiting Indian Conditions.
109300 mm dia pipe, 6mm Pipe Wall Thickness
110350 mm dia pipe, 6mm Pipe Wall Thickness
111400 mm dia pipe, 6mm Pipe Wall Thickness
112450 mm dia pipe, 8mm Pipe Wall Thickness
113500 mm dia pipe, 8mm Pipe Wall Thickness
114600 mm dia pipe, 8mm Pipe Wall Thickness
115Survey site Investigation Planning, design Drawings Road for of required dia Rising main and distribution pipe with casing pipe as required for proper completion of work required size of MS casing pipe as per drawing and as per (IS:3589 & made from confining to IS:2062) with 750 Micron PU coating internally and 250 micron anti corrosive bituminous paint externally by trenchless technology method at an average depth 3.60 mtr from natural ground level up to top of casing pipe including excavation & filling of Pit, Dewatering arrangement, Supporting system for soil, all complete work including supply & fixing specials in carrier pipe over main pipe, including supply of all materials, labour T&P etc. for proper completion of work as per instruction of Engineer.
116Drain crossing 0.50 m to 1.50 width
117Drain crossing 1.50-3.0 width
118Culvert crossing (above 3.0m wide culvert)
119Reinstatement of following type of roads including supply of all materials, labour, T&P etc. required for proper compiition of work as per specifications
120Bituminous Road (Laying of Bituminous road providing grannular sub base, WBM, Dense bituminous macadam and bituminous concrete course in desired thickness along with primer, tack coat and seal coat (Thickness should be taken according to PWD specification of the respective roads) and proper compaction including all material, labour, T&P etc. complete.
121Cement Concrete Road (Laying C C road slab 100mm thick in 1:2:4 cement, coarse sand and 20 mm stone ballast over 100 mm thick P.C.C. 1:4:8 in cement, coarse sand and 20-40 mm thick Stone ballast, including supply of all labour, material, T&P etc. complete as per direction of engineer in charge).
122C.C.Tiles Road with new required Tiles as per site condition (Laying of 80 mm thick) including dressing surface and including supply of tile, filling of jointing with local sand spreading and blinding coat of 10 mm to 25 mm deep of local sand over the entire surface and including all labour T&P etc. required for proper completion of work with 100 mm thick P.C.C. 1:4:8 in cement, coarse sand and 20-40 mm thick Stone ballast.
123B.O.E. Road with required new bricks as per site condition.
124Provision for Single Tap ferrule house connection in following dia distribution main with fixing of saddle (electro fusion tapping saddle for making connection with HDPE distribution pipeline, DI strap saddle, ferrule for making connection with distribution pipe line other than HDPE), connection fittings, GM ferrule of 15mm dia including brass tape with welded, 20mm dia (OD) HDPE pipe (PE 100/PN 12.5) and 20 mm dia (OD) G.I. pipe class B upto house holde also including dismantalling of roads, excavation of pit/trenches ,road reinstatement, supply of all fittings materials, labour, T&P etc. all work complete as per Type & Design Drawing direction of engineer in charge.
125In BOE Road
126Upto 110mm dia
127For 125mm to above dia
128In CC Road
129Upto 110mm dia
130For 125mm to above dia
131In Bituminous Road
132Upto 110mm dia
133For 125mm to above dia
134In Interlocking C.C. Tile Road
135Upto 110mm dia
136For 125mm to above dia
137In Kachha Road
138Upto 110mm dia
139For 125mm to above dia
140Shifting of Existing House connections from existing pipe line to new pipe line in different sizes of distribution pipes of various sizes, including supply and carting of specials, trenching, pipe laying and jointing (using existing serviceable and new materials such as 20mm HDPE, 20mm GI, saddles, couplers, elbows, bib cocks, etc.), alignment, dewatering, excavation, barricading, road dismantling and road reinstatement. Includes all labor, T&P, materials, and incidentals for completion in all road types.
141CC Road (upto 110mm dia)
142Interlocking Road (upto 110mm dia)
143SCHEDULE (G-4)
144Construction of R.C.C. framed Combined H.T. Panel room(5.50mx4.0m), L.T. Panel room (4.0mx3.50m), Meter Room(3.0mx3.0m), Electric Power Sub station room, internal size as per approved by Engineer In-Charge/compitent authority to control panel/switches/mountings and accessories including design and drawings, Supply all materials, labour, T&P etc. all complete.
145For Zone 9 H.T. Panel room(5.50mx4.0m), L.T. Panel room (4.0mx3.50m), Meter Room(3.0mx3.0m), Electric Power Sub station room
146For Zone 10A H.T. Panel room(5.50mx4.0m), L.T. Panel room (4.0mx3.50m), Meter Room(3.0mx3.0m), Electric Power Sub station room
147SCHEDULE (G-5)
148Construction of New Pump House cum Chloronating Room size 3.60X3.0 X3.60 m and 1.8x2.5x3.0 m including supply of all material,labour,T&P etc. complete.(other specifications and details can be get from engineer-in-charge.) with all as per type Design.
149Repairing Works of Existing Pump Houses
150Repairing of existing pump houses as per direction of Engineer-in-charge including all major & minor crack/settlement repair, floor reapir,plaster repair, Door, window, internal electrification, two coats of apex paints etc all complete.
151Construction of 1.0x1.0x1.3 m masonry type bypass chamber including plaster supply of all materials, labours, T&P etc. required for proper completion of work
152Extra 1st class brick work in 1:6 cement and coarse sand mortar in foundation and plinth due to low land area inclduing supply of all materials, labours, T&P etc. required for proper completion of work (SOR 1029)
153Construction of 3.0mx3.0mx2.0m masonry type VFD Pump chamber including plaster supply of all materials, labours, T&P etc. required for proper completion of work
154Site Development Works
155Construction of 230 mm thick Brick Boundry wall 1.8 m height from plinth level with RCC Column, Plinth Beam, Coping, and Barbed wire fencing at top of B/Wall etc. including supply of all material,labour,T&P etc. complete.(other specifications and details can be get from engineer-in-charge.) with all as per type Design.
156Repairing of existing boundary wall as per direction of Engineer-in-charge.
157Extra Ist class brick work in 1:6 cement and coarse sand mortar in foundation and plinth due to low land area including supply of all materials, labour,T&P etc required for proper compltion of work.
158Supply and Fixing of 3.6m wide MS gate with 1.2m wide wicket gate Including fabrication and supply of steel and construction of boundary pillars etc. all complete.
159Supply and laying of 80mm thick Cement interlocking tiles for approach road including preparation of 100mm thick subgrade with lean concrete 1:4:8 including supply of all material, labour and T&P etc complete for proper completion of the work.
160Earth filling work including transportation, cartage, laoding unloading etc complete.
161Provision for inside square drain including supply of all materials labour and T & P etc. complete.
162Recharge of ground water by Roof Top Rain Water of Pump house & Staff quarter, water available from bye pass of tubewell and over flow of over head tank as per drawing including supply of all materials, labour, T&P etc. complete.
163Construction of Rain Water Harvesting Chamber 5.50m x3.50x 1.80m with 02 Nos 110mm Dia, 20 mtr Deep Borewell in Water Works Campus.
164Construction of Rain Water Harvesting Chamber 1.66m x1.66x 1.80m with 01 Nos 110mm Dia, 20 mtr Deep Borewell in Campus of Proposed TW
165Landscaping, plantation work in existing water works campus as per direction of Engineer-in-charge.
166SCHEDULE (G-7)
167Construction of framed structure MCS BUILDING (12MX20M)/Office-cum-Lab-SCADA Room including internal & external (water supply, Sanitary work, Electrication work), external service connection, provision for sewerage system, footpath with PCC base, 80 MM THK Paver Block and Kerb Stone edging,Horticultur work including Earth filling,grassing, tree palntation/Shrubs and Potted Plants, with Street Lights etc. including supply of all necesseary works the cost of furniture Almirah, fully furnished etc., and secuirty arrangement with all required materials, labour etc. complete as per direction of Engineer-in-charge.(Other specifications and details can be get from engineer-in-charge.) with all as per type Design etc. complete in all respect. Lab Equipment will be suplied as per instruction/approval by engineer incharge. (12.46 M*20.46M = 254.93 sqm)
168Construction of framed structure ADMINISTRATIVE BUILDING (20MX16M) including internal & external (water supply, Sanitary work, Electrication work), external service connection, provision for sewerage system FOOTPATH WITH PCC BASE, 60 MM THK PAVER BLOCK AND KERB STONE EDGING, HORTICULTUR OPERATIONS INCLUDING 300 MM EARTH FILLING,GRASSING, TREE PLANTATION/SHRUBS AND POTTED PLANTS etc. including supply of all necesseary works, and secuirty arrangement with all required materials, labour etc. complete as per direction of Engineer-in-charge. NOTE -Admin buidling (office cum lab) will not be handed over to NPP HAPUR. (20.46 M*16.46 M = 336.77 sqm)
169Construction of Staff Quarters: Type-2 (G+2 Building with Mumty slab) (421.40 Sqm area ) including internal & external (water supply, Sanitary work, Electrication work), external service connection, provision for sewerage system, 100 Rmt Footpath with PCC base & 80 MM THK Paver Block and Kerb Stone edging, Horticulture work including Earth filling,grassing, tree palntation/Shrubs and Potted Plants, with Street Lights etc. including supply of all necesseary works the cost of furniture Almirah etc., and secuirty arrangement with all required materials, labour etc. complete as per direction of Engineer-in-charge.(Other specifications and details can be get from engineer-in-charge.) with all as per type Design etc. complete in all respect. STREET LIGHTING I/C SITC OF LED STREET/COMPOUND LIGHTS/HIGH MAST/PATHWAYS LIGHTING FOR ENTIRE CAMPUS - ON ENTIRE PLOT AREA (2500 SQM). NOTE -Staff Quarters will not be handed over to NPP HAPUR.
170Construction of Staff Quarters: Type-3 (G+2 Building with Mumty slab) (530.30 Sqm area ) including internal & external (water supply, Sanitary work, Electrication work), external service connection, provision for sewerage system, 100 Rmt Footpath with PCC base, 80 MM THK Paver Block and Kerb Stone edging,Horticultur work including Earth filling,grassing, tree palntation/Shrubs and Potted Plants, with Street Lights etc. including supply of all necesseary works the cost of furniture Almirah etc., and secuirty arrangement with all required materials, labour etc. complete as per direction of Engineer-in-charge.(Other specifications and details can be get from engineer-in-charge.) with all as per type Design etc. complete in all respect. STREET LIGHTING I/C SITC OF LED STREET/COMPOUND LIGHTS/HIGH MAST/PATHWAYS LIGHTING FOR ENTIRE CAMPUS - ON ENTIRE PLOT AREA (2500 SQM).
171E&M Work
172CONSTRUCTION OF 13 No. NEW & 04 No. REBORE TUBEWELL Zone-1 (01 No. Rebore), Zone-3 (01 No. Rebore), Zone-4 (01 No. New), Zone-5 (03 No. New), Zone-6 (02 No. New), Zone-7 (01 No. Rebore), Zone-8 (01 No. Rebore), Zone-9 (04 No. New), Zone-10 B (01 No. New), Zone-11 (02 No. New)
173Transportation of rig machine erection, dismantling and associated T&P Complete in all respect including required all material , labour etc.
174DRILLING OF TUBEWELL BORE
175Drilling of 600 mm. dia bore from G.L. to 100 M. BGL
176Drilling of 500 mm. dia bore from 100 BGL to 200 M. BGL
177Logging of bore hole by electirc logger
178TUBEWELL ASSEMBLY - MSERW Tube well assembly with all required parts like plain pipe, slotted pipe, MS rings, well cap, bail plug clamp, reducer, central guide, support structure etc. as required and as per typed design complete in all respect.
179300 mm. dia 7.1 mm thick MSERW Plain Pipe with MS ring & reducer
180200 mm.dia 7.1 mm thick M.S. Plain pipe & Slotted pipe with MS ring
181Lowering of Tubewell assembly duly welded including welding electrode
182300 mm. dia 7.1mm thick MSERW Plain / Slotted Pipe
183200 mm. dia Plain/Slotted Pipe 54 M. BGL to 100 M. BGL
184200 mm. dia Plain/Slotted Pipe 100 M. BGL to 190 M. BGL
185Supply & Shruoding of Lal Kuan Pea Gravel 1.6 to 4.8 mm. size for Tubewell
186DEVELOPMENT OF TUBEWELL
187Transportation, Erection, Dismantling of 350 P.S.I. Compressor.
188Charges for Development by 350 P.S.I. Compressor per hour.
189Transportation, Erection, Dismantling of 3 Cusec O.P. Unit and yeild Test.
190Charges for Development by 3 Cusec O.P. Unit per hour.
191Chemical and Bacteriological test of water sample form departmentel / NABL approved lab.
192Site clearance, Baricating , gravel shifting and other allied works required for construction of Tube well.
193PUMPING PLANT AND ELECTRO-MECHANICAL & INSTRUMENTATION WORKS AT TUBEWELLS OF DIFFERENT ZONES
194Supply, installation, testing and commissioning of Clear water submersible pump for Tubewell (IS 9236) made of SS 410 shaft & impeller, made of SS 410 shaft & impeller complete with electric motor (IS 8034) capable to operate on 380/420 volts 3 phase 50 c/s A.C. of following rating capacities. (Note- The discharge and head indicated are tentative and shall be finalized during execution of the work.)
195FOR ZONE - 1 (FEED TO OHT)
196Capable for giving discharge 1750 LPM, at 60 Mtr Head for existing Tube well
197Capable for giving discharge 1750 LPM, at 71 Mtr Head for existing Tube well
198Capable for giving discharge 1800 LPM, at 66 Mtr Head for rebore Tube well
199FOR ZONE - 2 (FEED TO OHT)
200Capable for giving discharge 1000 LPM, at 59 Mtr Head for existing Tube well
201FOR ZONE - 3 (FEED TO OHT)
202Capable for giving discharge 1700 LPM, at 63 Mtr Head for 02 No. existing & 01 No. Rebore Tube well
203FOR ZONE - 4 (FEED TO OHT)
204Capable for giving discharge 1200 LPM, at 60/62 Mtr Head for existing Tube well
205Capable for giving discharge 1500 LPM, at 64 Mtr Head for new Tube well
206FOR ZONE - 5 (FEED TO OHT)
207Capable for giving discharge 1650 LPM, at 65 Mtr Head for new Tube well
208Capable for giving discharge 1650 LPM, at 69 Mtr Head for new Tube well
209FOR ZONE - 6 (FEED TO OHT)
210Capable for giving discharge 1650 LPM, at 70 Mtr Head for existing Tube well
211Capable for giving discharge 1650 LPM, at 69 Mtr Head for new Tube well
212Capable for giving discharge 1650 LPM, at 65 Mtr Head for new Tube well
213FOR ZONE - 7 (FEED TO OHT)
214Capable for giving discharge 1400 LPM, at 60/62 Mtr Head for 01 No. existing & 01 No. Rebore Tube well
215FOR ZONE - 8 (FEED TO OHT)
216Capable for giving discharge 1650 LPM, at 59 Mtr Head for existing Tube well
217Capable for giving discharge 1750 LPM, at 61 Mtr Head for rebore Tube well
218FOR ZONE - 9 (FEED TO CWR)
219Capable for giving discharge 1500 LPM, at 36/40 Mtr Head for new Tube well
220FOR ZONE - 10A (FEED TO CWR)
221Capable for giving discharge 1500 LPM, at 36/38/40 Mtr Head for existing Tube well
222FOR ZONE - 10B (FEED TO OHT)
223Capable for giving discharge 1500 LPM, at 63 Mtr Head for new Tube well
224Capable for giving discharge 1000 LPM, at 67 Mtr Head for existing Tube well
225FOR ZONE - 11 (FEED TO OHT)
226Capable for giving discharge 1700 LPM, at 65/66/69 Mtr Head for 02 No. new & 01 No. existing Tube well
227Supply, installation, testing and commissioning of Main Piping & 02 Nos DIDF sluice valves with 24Mtr. Column pipe, NRV, 900 CI D/F Bend, CI A/F Tee, D/F pipe ( 1.5 m long 02 nos and 1.0 m long 01 no.), power wiring, earthing, painting, wiring of pump house (Internal & External), Chain pully block complete in all respect with all required material, T&P labour of 150 mm Dia. size for tubewell
228Supply of 3 Mtr Long Heavy duty exta Coloum pipe 150 mm Dia. Size (6 No for each TW )
229Supply, installation, testing and commissioning of Main Piping & 02 Nos DIDF sluice valves with 24Mtr. Column pipe, NRV, 900 CI D/F Bend, CI A/F Tee, D/F pipe ( 1.5 m long 02 nos and 1.0 m long 01 no.), power wiring, earthing, painting, wiring of pump house (Internal & External), Chain pully block complete in all respect with all required material, T&P labour of 100 mm Dia. size for tubewell
230Supply of 3 Mtr Long Heavy duty exta Coloum pipe 100 mm Dia. Size (6 No for each TW )
231Supply of Electrically operated actuater (Totally enclosed, weather-proof and dust proof construction with IP-67/68, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and suitable for manual operation for emergency which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of suitable Volt, torque switch dial and with TEFC squirrel cage induction) suitable to SCADA operation, suitable for following dia size sulice valve.
232Suitable for 150 mm dia size sluice valve for Tubewell.
233Suitable for 100 mm dia size sluice valve for Tubewell.
234Supply of D.I./ D.F. Dismantling Joints is a variable length Double Flanged Short Piece constituted by a flange / Spigot Tailpiece inserted into the other Tailpiece which allows the distance between the two flanges to be varied within certain limits thus providing a variable distance piece between two fixed flange end devices like Pumps and Valves. The Dismantling Joint to be supplied complete with Sealing Rubber Gaskets of EPDM quality (IS:5382/1985 Type-4), Cast Iron Follower Glands and Mild Steel (Zinc Coated) Nut Bolts of following sizes
235D.I./ D.F. Dismantling Joints of 100 mm dia size for Tubewell.
236D.I./ D.F. Dismantling Joints of 150 mm dia size for Tubewell.
237Supply & fixing of Submersible flat copper condutor cable 3C x 10 sq. mm PVC Sheathed double run (2Rx50m = 100 mtr for each TW)
238Supply & fixing of Submersible flat copper condutor cable 3C x 6 sq. mm PVC Sheathed double run (2Rx50m = 100 mtr for each TW)
239Supply & laying of L.T. XLPE insulated armoured aluminium conductor cable of 1.1 KV grade Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P-(I),conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999.From transformer to Main LT panel of 3.5C x 35 Sq.mm.
240Motor inspection, B&L and Challan fee for tubewell
241MOTOR CONTROL CENTER (MCC) PANEL :-Supply of single front, Indoor & floor mounted,cubical type control Panel factory fabricated (2 mm thick for sructure, 2 mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coated dust and vermin proof IP-54 / IS:2147 IP 54 Protection , Industrial grade for all equipment and 24V and power, considered Earth Bus-Bar-GI Strip compitable to SCADA operation with RS485 Port consisting of 100 A/125 A/suitable rating, 36KA, TPN, MCCB microprocessor baseed (O/C,S/C) release - 1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital Multifunction Meter - 1 No, Digital Voltmeter 0-500V - 1 No, Digital Ammeter 0-400A - 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.
242Supply of Air Cooled Digital soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button and Instrument Fuses, suitable to SCADA operation with RS485 Port of following rating capacity.
243Digital soft starter 40 HP / 30 KW
244Digital soft starter 50 HP / 37 KW
245Digital soft starter 25 HP / 18.50 KW
246Supply of microprocessor based three phase sensing power factor correction relay panel , IEC / EN 61000-6- (2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR of following rating capacity.
247Microprocessor based APFC panel with relay of 20 KVAR
248Microprocessor based APFC panel with relay of 15 KVAR
249Microprocessor based APFC panel with relay of 25 KVAR
250Supply of Servo Controlled Automatic Voltage stabilizer suitable for out put voltage of 415 Volt +/-1%, 3 Ph, 50 Hz, with copper wound transformer (air/oil cooled) . The stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range of 10%. The stabilizer should be constructed in cubical box, with bi-directional wheels for easy handling, necessary monitors and user's controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and out put voltage, Auto/Manual selector switch, Raise/Low push buttons etc. Suitable capacity termination strips and bus bars for incoming and out going cable should be provided. All three phases shall be independently monitored and corrected (Operating voltage 240V - 500V), 415 volt, 3Phase, 50Hz -- of following rating capacitis.
251Servo Controlled Automatic Voltage stabilizer of 60 KVA
252Servo Controlled Automatic Voltage stabilizer of 75 KVA
253Servo Controlled Automatic Voltage stabilizer of 40 KVA
254Servo Controlled Automatic Voltage stabilizer of 50 KVA
255Supply of Auto phase reversal unit with inbuilt time delay & enclosure (conforming to IEC:60947-1 & IEC:60947-b-1) 125 Amp rating
256Supply of CE/UL Certified Surge protector for control panel
257Providing & Fixing of IK07 IP-66 protected high power LED flood street system with Pressure diecast aluminium housing LM6/ ADC12 material 50 Watt
258Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS: 15683:2006
259Supply of Rubber mats for electrical purpose as per IS:5425-1969, plain/chequered (1mX2m) - 19mm thickness
260Supply of CE/UL Certified Full Bore Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.0 MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement ‘of IEC 60529, Accuracy : + 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signa convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable, of following size.
261Full Bore Electromagnetic Flow Meter of 150 mm dia. at tubewell outlet
262Full Bore Electromagnetic Flow Meter of 100 mm dia. at tubewell outlet
263Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel including mounting arrangement.Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4\\" LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68
264Supply of CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with intelligent GSM Based modem unit with CPU and Power supply with analog and digital parameter and features as specified to store and transmit data on GSM backbone, RTU designed with logic to transfer data at multiple stations.
265Supply of GSM/GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer, antenna made for pumping plant with SIM and recharge
266Supply of CE & UL Certified 7\\" HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters
267Supply of CE/UL Certified Intelligent energy meters
268Supply of CE/UL Certified Hydrostatic type sub soil water level transmitter for Tubewell
269Complete cabling for instrumentation equipments with power supply of panels form source for tubewell & connected OHT
270Security Survelliance IP Camera with all required accessories & Recorder
271Supply of Automatic / SCADA operated electromegnatic chlorination dozzer system with level sensors at tubewells
272Supply of UPS 600 VA for Tubewell Panel
273Supply of 3 Phase out put 10 KVA UPS with battery bank of 60 minutes backup for operating OHT outlet valve during power failure.
274Complete dismantling of Pumping plant and associated accessories from existing tubewell.
275ELECTRO-MECHANICAL WORKS AT OHT's
276Supply of DIDF Sluice valve with Electrically operated actuater (Totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and suitable for manual operation for emergency which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of suitable rating Volt, torque switch dial and with TEFC squirrel cage induction) operated with positioning card suitable to SCADA operation Valves are suitable for hydrostatic test pressure of 17.6Kg./Cm2 for seat and 24Kg./Cm2 for body(PN-1.6) of following size at Existing OHT outlet.
277DIDF Sluice valve with Electrically operated actuater of 350 mm dia size.
278DIDF Sluice valve with Electrically operated actuater of 400 mm dia size.
279DIDF Sluice valve with Electrically operated actuater of 450 mm dia size.
280Supply of Electrically operated actuater (Totally enclosed, weather-proof and dust proof construction with IP-67/68, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and suitable for manual operation for emergency which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of suitable Volt, torque switch dial and with TEFC squirrel cage induction) suitable to SCADA operation for New OHT outlet sulice valve of following size. (Note-The sluice valve at the new OHT outlet shall be under the civil scope and included in the OHT cost. The valve shall be SCADA-compatible.)
281Electrically operated actuater of suitable for 450 mm dia size OHT Outlet sluice valve.
282Electrically operated actuater of suitable for 400 mm dia size OHT Outlet sluice valve.
283Electrically operated actuater of suitable for 300 mm dia size OHT Outlet sluice valve.
284Supply of D.I./ D.F. Dismantling Joints is a variable length Double Flanged Short Piece constituted by a flange / Spigot Tailpiece inserted into the other Tailpiece which allows the distance between the two flanges to be varied within certain limits thus providing a variable distance piece between two fixed flange end devices like Pumps and Valves. The Dismantling Joint to be supplied complete with Sealing Rubber Gaskets of EPDM quality (IS:5382/1985 Type-4), Cast Iron Follower Glands and Mild Steel (Zinc Coated) Nut Bolts of following sizes
285D.I./ D.F. Dismantling Joints of 300 mm dia size for OHT Outlet
286D.I./ D.F. Dismantling Joints of 350 mm dia size for OHT Outlet
287D.I./ D.F. Dismantling Joints of 400 mm dia size for OHT Outlet
288D.I./ D.F. Dismantling Joints of 450 mm dia size for OHT Outlet
289Supply of CE/UL cirtified of Radar type level transmitter CE marked with following technical parameters and Interfacing with PLC panel including mounting arrangement for OHTOutput-4-20 mA / HART Power supply - 24V DC ext. Display - 4\\" LED Range- 0 to …30... mtrs Accuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68
290Supply of CE/UL Certified Residual chlorine analyser / meter must have automatic sensor cleaning facility at pure water sump and Interfacing with PLC panel. Residual Chlorine metershall comprises of 3 components i.e. sensors,flow through assembly and transmitter with indicator and gives 2 outputs one to Local display & other to PLC including Mounting arrangement. mOverall Range : 0 ‐ 8 mg/l (ppm)nAccuracy : 2% of full scale Supply Voltage : 230 V ac Output : 4‐20 mA Membrane free sensor of 2 gold plated electrodes for long term stability and reference electrode (ag/Agcl) must be provided to avoid maintenance. IP 65 Nema 4 housing protection class required at OHT outlet
291Installation, testing and comissioning of pumping plant & associated all equipments at Tubewell & OHT as per approved drawing shall be done by bidder painting of pumping plant & main piping-valves.
292PUMPING PLANT AND ELECTRO-MECHANICAL & INSTRUMENTATION WORKS AT PROPOSED CWR (700 KL) ZONE - 9
293Supply of Vertical type self-water lubricated statically, dynamically, hydraulically balanced turbine pump capable of discharging at 1450 rpm the following duty condition as given below due to all causes with surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amended thereafter to suit the site condition.The Pump Bowl assembly shall be FG: 260with 2% NiCi with CF8M impeller running at 1450 rpm., head shaft, SS line shaft , Rubber line shaft bearing , C.I. Bearing retainer, Suction bell mouth, strainer, 5 mtr/suitable length column assembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC 60034-1) suitable for the above pump continuous rated TEFC IP-55 with Class 'F' insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump.CAPACITY:- 3150 LPM / 37 Mtr. HEAD / 40 HP MOTOR (2w+1s)(Note- The discharge and head indicated are tentative and shall be finalized during execution of the work.)
294MAIN PIPING AND VALVES :-
295Supply of DIDF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(part I & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing of 200 mm dia size
296Supply of DIDF sluice valve with Electrically operated actuater (Totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and suitable for manual operation for emergency which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of suitable rating Volt, 5 Amp, torque switch dial and with TEFC squirrel cage induction) operated suitable to SCADA operation sluice valve are suitable for hydrostatic test pressure of 11Kg./Cm2 for seat and 15Kg./Cm2 for body (PN-1.0) of 200 mm at pump delivery
297Supply of DIDF manually operated sluice valve are suitable for hydrostatic test pressure of 11Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0 Rating) Sluice Valve of 250 mm at Common header & by pass
298Supply of MSDF main piping 1 mtr outside the pump house of following sizes.250 x 200 x 250 mm MS D/F Tee (10 mm thickness) -3 No200 mm MS D/F Pipe 0.50 mt. (10 mm thickness) - 3 No200 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 3 No250 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 3 No250 mm MS D/F Pipe 2.00 mt. (10 mm thickness) -2 No250 mm MS D/F (10 mm thickness) Bend 90o - 2 No250 mm Blind Flange - 1 NoDismentling joints of suitable sizes - 1 LotNecessary GI Nut Bolt’s & Rubber Packing - 1 Lot(Note- The quantity is tentative and shall be considered complete in all respects, including all required accessories. No extra item or payment shall be admissible on this account.)
299Supply of D.I./ D.F. Dismantling Joints is a variable length Double Flanged Short Piece constituted by a flange / Spigot Tailpiece inserted into the other Tailpiece which allows the distance between the two flanges to be varied within certain limits thus providing a variable distance piece between two fixed flange end devices like Pumps and Valves. The Dismantling Joint to be supplied complete with Sealing Rubber Gaskets of EPDM quality (IS:5382/1985 Type-4), Cast Iron Follower Glands and Mild Steel (Zinc Coated) Nut Bolts of Following size
300Dismantling joint 200 mm dia size at pump delivery
301Dismantling joint 250 mm dia size at common header
3023Ton capacity hand operated over head Travelling (HOT) crane H- Type suitable for a span upto 6 Mtrs, and travel length upto 10 Mtrs. with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including girder.
303MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 2 mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coated dust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION 160 A, 36KA, TPN, MCCB microprocessor baseed (O/C,S/C) release - 1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital Multifunction Meter - 1 No, Digital Voltmeter 0-500V - 1 No, Digital Ammeter 0-400A - 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION125 A, 36KA, TPN, MCCB microprocessor based (O/C,S/C) RELEASE - 3 No, Spreader Links & Extended ROH for MCCB - 3 Nos., multifunction meter-03 Nos, 63A TPN MCCB 35KA - 3 Nos. Terminal 63A
304Supply of Air Cooled Digital soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button and Instrument Fuses, suitable to SCADA operation with RS485 Port of rating capacity 40 HP / 30 KW
305Supply of microprocessor based three phase sensing power factor correction relay panel , IEC / EN 61000-6- (2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR rating capacity of 40 KVAR
306Supply & laying of 1.1 KV grade PVC insulated un armoured multi strand copper conductor cable of 3C x 25 sq.mm from control Panel to respective Motors with lugs etc. (copper conductor should be electrlytic grade coppe, purity >99.97 % ISI markedas per IS:1554 P-I / IS:7098 P- I)
307Supply & Fixing of Powder coated GI Cable Tray 150mmx50mmx2 mm
308Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043
309Supplying and laying 50 mm X 6 mm GI strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
310Supply of ABC Dry Powder type Fire Extinguisher 4.5 kg conforming to IS: 15683:2006
311Supply of Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) of 200 Amp
312S& F of all in one solar LED street light fixture with Integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate battery with BIS approved make .luminaire should be secondary optic lenses for better distribution with delivered efficacy of >100 Lumen per watt. Luminaire can be supplied with Hybrid switch along with indicator to understand the source of power( either from solar or AC supply).shall have certificate tested fromMNRE approved Lab. Guarantee for total system is two years .Note: All the above should be integrated and should be 1 system. make: Bajaj/ Philips / Crompton. Compact Solar LED Street Light - 60W/12V/27Ah with GI pole
313Internal & External electrification of Pump house
314Twin tube light covered LED 20 Watt
315450 mm dia exhaust fan
316Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 50 Watt Flood light
317Complete wiring of Pump house with 1.5 Sqmm & 2.5 Sqmm multistarnd copper conductor wire 1.1 KV with required 5A & 15A switches, ceiling rose
318Supply of CE/UL Certified Surge protector for control panel
319Rubber mats for electrical purpose as per IS:5425-1969, plain/chequered (1mX2m) - 19mm thickness
320Supply of Automatic / SCADA operated electromegnatic chlorination dozzer system
321Supply of CE/UL certified Full bore Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.0 MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement ‘of IEC 60529, Accuracy : + 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signa convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable, of 250 mm dia size at common header
322Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel including mounting arrangement.Output 4-20 mA / HARTPower supply - 24V DC ext.Display - 4\\" LEDAccuracy - +/- 0.1 % of full scale or betterEnclosure- IP 68
323Supply of CE/UL cirtified of Radar type level transmitter CE marked with following technical parameters and Interfacing with PLC panel including mounting arrangement for CWROutput-4-20 mA / HARTPower supply - 24V DC ext.Display - 4\\" LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or betterEnclosure- IP 68
324CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with intelligent GSM Based modem unit with CPU and Power Supply with analog and Digital Parameter and features as specified for each for each ZPS/OHT to store and transmit data on GSM backbone, RTU designed with logic to transfer data at multiple stations and also compatible for satellite communication alongwith control panel with IP 54 Protection , Industrial grade for all equipment and 24V and power supply
325GSM/GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer, antenna made for pumping plant with SIM and recharge
326CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with intelligent GSM Based modem unit with CPU and Power Supply with analog and Digital Parameter and features as specified for each for each ZPS/OHT to store and transmit data on GSM backbone, RTU designed with logic to transfer data at multiple stations and also compatible for satellite communication alongwith control panel with IP 54 Protection , Industrial grade for all equipment and 24V and power supply for standalone OHT
327GSM/GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer, antenna made for pumping plant with SIM and recharge for stand alone OHT
328Supply of control panel with IP 54 Protection , Industrial grade for all equipment and 24V and power supply
329CE & UL Certified 7\\" HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters
330CE/UL Certified Intelligent energy meters
331Complete cabling for instrumentation equipments with power supply of panels form source
332Security Survelliance IP Camera with all required accessories
333Supply of UPS 600 VA for CWR Panel single phase out put
334Installation, testing and comissioning of pumping plant & associated all equipments as per approved drawing shall be done by bidder including chequerred plate and painting of pumping plant & main piping-valves.
335PUMPING PLANT AND ELECTRO-MECHANICAL & INSTRUMENTATION WORKS AT EX. CWR (360 KL) ZONE - 10A
336Supply of Vertical type self-water lubricated statically, dynamically, hydraulically balanced turbine pump capable of discharging at 1450 rpm the following duty condition as given below due to all causes with surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amended thereafter to suit the site condition.The Pump Bowl assembly shall be FG: 260with 2% NiCi with CF8M impeller running at 1450 rpm., head shaft, SS line shaft , Rubber line shaft bearing , C.I. Bearing retainer, Suction bell mouth, strainer, 5 mtr/suitable length column assembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC 60034-1) suitable for the above pump continuous rated TEFC IP-55 with Class 'F' insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump.CAPACITY:- 2450 LPM / 30 Mtr. HEAD / 25 HP MOTOR (2w+1s)(Note- The discharge and head indicated are tentative and shall be finalized during execution of the work.)
337MAIN PIPING AND VALVES :-
338Supply of DIDF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(part I & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing of 150 mm dia size
339Supply of DIDF Sluive valve with Electrically operated actuater (Totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and suitable for manual operation for emergency which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of suitable rating Volt, torque switch dial and with TEFC squirrel cage induction) operated suitable to SCADA operation sluice valves are suitable for hydrostatic test pressure of 11Kg./Cm2 for seat and 15Kg./Cm2 for body (PN-1.0) of 150 mm at pump delivery
340Supply of DIDF manually operated sluice valve are suitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0 Rating) Sluice Valve of 200 mm at Common header & by pass
341Supply and fabrication of main piping of following sizes200 x 150 x 220 mm MS D/F Tee (10 mm thickness) -3 No150 mm MS D/F Pipe 0.50 mt. (10 mm thickness) - 3 No150 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 3 No200 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 3 No200 mm MS D/F Pipe 2.00 mt. (10 mm thickness) -2 No200 mm MS D/F (10 mm thickness) Bend 90o - 2 No200 mm Blind Flange - 1 NoDismentling joints of suitable sizes - 1 LotNecessary Nut Bolt’s & Rubber Packing - 1 Lot(Note- The quantity is tentative and shall be considered complete in all respects, including all required accessories. No extra item or payment shall be admissible on this account.)
342Supply of D.I./ D.F. Dismantling Joints is a variable length Double Flanged Short Piece constituted by a flange / Spigot Tailpiece inserted into the other Tailpiece which allows the distance between the two flanges to be varied within certain limits thus providing a variable distance piece between two fixed flange end devices like Pumps and Valves. The Dismantling Joint to be supplied complete with Sealing Rubber Gaskets of EPDM quality (IS:5382/1985 Type-4), Cast Iron Follower Glands and Mild Steel (Zinc Coated) Nut Bolts of Following size
343Dismantling joint 200 mm dia size at pump delivery
344Dismantling joint 250 mm dia size at common header
3453Ton capacity hand operated over head Travelling (HOT) crane H- Type suitable for a span upto 6 Mtrs, and travel length upto 10 Mtrs. with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including girder.
346MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 2 mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coated dust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION 160 A, 50KA, TPN, MCCB microprocessor baseed (O/C,S/C) release - 1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital Multifunction Meter - 1 No, Digital Voltmeter 0-500V - 1 No, Digital Ammeter 0-400A - 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION100 A, 50KA, TPN, MCCB microprocessor based (O/C,S/C) RELEASE - 3 No, Spreader Links & Extended ROH for MCCB - 3 Nos., 63A TPN MCCB 35KA - 3 Nos. Terminal 63A
347Supply of Air Cooled Digital soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button and Instrument Fuses, suitable to SCADA operation with RS485 Port of rating capacity 25 HP / 18.50 KW
348Supply of microprocessor based three phase sensing power factor correction relay panel , IEC / EN 61000-6- (2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR rating capacity of 25 KVAR
349Supply & laying of 1.1 KV grade XLPE insulated un armoured multi strand copper conductor cable of 3C x 16 sq.mm from control Panel to respective Motors with lugs etc. (copper conductor should be electrlytic grade coppe, purity >99.97 % ISI markedas per IS:1554 P-I / IS:7098 P- I)
350Supply & Fixing of Powder coated GI Cable Tray 150mmx50mmx2 mm
351Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043
352Supplying and laying 50 mm X 6 mm GI strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
353Supply of ABC Dry Powder type Fire Extinguisher 4.5 kg conforming to IS: 15683:2006
354Supply of Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) of 200 Amp
355S& F of all in one solar LED street light fixture with Integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate battery with BIS approved make .luminaire should be secondary optic lenses for better distribution with delivered efficacy of >100 Lumen per watt. Luminaire can be supplied with Hybrid switch along with indicator to understand the source of power( either from solar or AC supply).shall have certificate tested fromMNRE approved Lab. Guarantee for total system is two years .Note: All the above should be integrated and should be 1 system. make: Bajaj/ Philips / Crompton. Compact Solar LED Street Light - 60W/12V/27Ah with GI pole
356Internal & External electrification of Pump house
357Twin tube light covered LED 20 Watt
358450 mm dia exhaust fan
359Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 50 Watt Flood light
360Complete wiring of Pump house with 1.5 Sqmm & 2.5 Sqmm multistarnd copper conductor wire 1.1 KV with required 5A & 15A switches, ceiling rose
361Supply of CE/UL Certified Surge protector for control panel
362Rubber mats for electrical purpose as per IS:5425-1969, plain/chequered (1mX2m) - 19mm thickness
363Supply of Automatic / SCADA operated electromegnatic chlorination dozzer system
364Supply of CE/UL certified full bore Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.0 MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement ‘of IEC 60529, Accuracy : + 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signa convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable, of 250 mm dia size at common header
365Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel including mounting arrangement.Output 4-20 mA / HARTPower supply - 24V DC ext.Display - 4\\" LEDAccuracy - +/- 0.1 % of full scale or betterEnclosure- IP 68
366Supply of CE/UL cirtified of Radar type level transmitter CE marked with following technical parameters and Interfacing with PLC panel including mounting arrangement for CWROutput-4-20 mA / HARTPower supply - 24V DC ext.Display - 4\\" LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or betterEnclosure- IP 68
367CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with intelligent GSM Based modem unit with CPU and Power Supply with analog and Digital Parameter and features as specified for each for each ZPS/OHT to store and transmit data on GSM backbone, RTU designed with logic to transfer data at multiple stations and also compatible for satellite communication alongwith control panel with IP 54 Protection , Industrial grade for all equipment and 24V and power supply
368GSM/GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer, antenna made for pumping plant with SIM and recharge
369Supply of control panel with IP 54 Protection , Industrial grade for all equipment and 24V and power supply
370CE & UL Certified 7\\" HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters
371CE/UL Certified Intelligent energy meters
372Complete cabling for instrumentation equipments with power supply of panels form source
373Security Survelliance IP Camera with all required accessories
374Supply of UPS 600 VA for CWR Panel
375Installation, testing and comissioning of pumping plant & associated all equipments as per approved drawing shall be done by bidder including chequerred plate and painting of pumping plant & main piping-valves.
376PUMPING PLANT AND ELECTRO-MECHANICAL & INSTRUMENTATION WORKS AT CLEAR WATER BOOSTER PUMPING PLANT FOR EX. OHT AT ZONE - 1, 2, 3, 4, 8 & 10A
377Supply of Horizontal type foot mounted self-water lubricated statically, dynamically, hydraulically balanced booster pump capable of discharging at 1450 rpm the following duty condition as given below due to all causes confirming to relevant IS and as amended as on date with accessories as per IS thereafter to suit the site condition.The Pump casing shall be FG: 260with 2% NiCi with CF8M impeller running at 1450 rpm., head shaft, SS line shaft , with Squirrel cage induction motor(IS:126152011/IEC 60034-1) suitable for the above pump continuous rated TEFC IP-67/68 with Class 'F' insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump of following capcities in module of 1 No working & 1 No standby (1w+1s)(Note- The discharge and head indicated are tentative and shall be finalized during execution of the work.)
378CAPACITY - 11710 LPM / 07 Mtr. HEAD / 40 HP MOTOR / ZONE -1
379CAPACITY - 4135 LPM / 08 Mtr. HEAD / 12.50 HP MOTOR / ZONE -2
380CAPACITY - 11710 LPM / 07 Mtr. HEAD / 40 HP MOTOR / ZONE -3
381CAPACITY - 8600 LPM / 09 Mtr. HEAD / 40 HP MOTOR / ZONE -4
382CAPACITY - 11700 LPM / 07 Mtr. HEAD / 40 HP MOTOR / ZONE -8
383CAPACITY - 8710 LPM / 09 Mtr. HEAD / 40 HP MOTOR / ZONE -10 A
384Supply of D.I./ D.F. Dismantling Joints is a variable length Double Flanged Short Piece constituted by a flange / Spigot Tailpiece inserted into the other Tailpiece which allows the distance between the two flanges to be varied within certain limits thus providing a variable distance piece between two fixed flange end devices like Pumps and Valves. The Dismantling Joint to be supplied complete with Sealing Rubber Gaskets of EPDM quality (IS:5382/1985 Type-4), Cast Iron Follower Glands and Mild Steel (Zinc Coated) Nut Bolts of Following size
385Dismantling joint 300 mm dia size at pump delivery
386Dismantling joint 350 mm dia size at pump delivery
387Dismantling joint 200 mm dia size at common header
388Supply of DIDF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(part I & II) PN-1.6 to be fixed after pumps for 90% fast closing & 10% slow closing of following sizes at Pump outlet
389300 mm dia size at pump delivery
390350 mm dia size at pump delivery
391Supply and fitting of Suitable size DIDF Main piping such as distance pieces, Bend, Tee, reducer/enlarger, rubber packing, ss nut-bolts etc. required for proper installation of bosster pumping plants in module of (1w+1s) at each site
392MOTOR CONTROL CENTER (MCC) PANEL :-Supply of Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 2 mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coated dust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION 50 A, 36KA, TPN, MCCB microprocessor baseed (O/C,S/C) release - 1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital Multifunction Meter - 1 No, Digital Voltmeter 0-500V - 1 No, Digital Ammeter 0-400A - 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. with suitable rating capacitorOUTGOING SECTION 50 A, 36KA, TPN, MCCB microprocessor baseed (O/C,S/C) release - 2 No , Spreader Links & Extended ROH for - 2 No
393Supply of Air Cooled The Variable frequency drive (VFD) shall be of a modern proven design, shall be fully digital, PLC/Microprocessor based, energy efficient, and shall provide very high reliability, high power factor, low harmonic distortion and low vibration and wear and noise, VFDs shall comply with the latest edition of IEEE 519 & IEC 61000 for both individual as well as total harmonic voltage and current distortion limits, VFD shall be capable of withstanding the thermal and dynamic stresses and the transient mechanical torque, resulting from short circuit. Any damage resulting from such a short circuit or internal fault shall be limited to the component concerned, VFD System shall maintain a power factor of 0.95 (minimum), Overall efficiency shall be minimum 96.5% for LV VFD, suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) suitable to SCADA operation with RS485 port of following rating.
394RATING CAPACITY - 9.30 KW / 12.50 HP
395RATING CAPACITY - 30 KW / 40 HP
396Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement.Output 4-20 mA / HARTPower supply - 24V DC ext.Display - 4\\" LEDAccuracy - +/- 0.1 % of full scale or betterEnclosure- IP 68
397Complete cabling for power supply and instrumentation equipments from pumping plant to panel
398Installation, testing and comissioning of pumping plant & associated all equipments as per approved drawing shall be done by bidder including chequerred plate and painting of pumping plant & main piping-valves.
399BEE : 5 Star rating 1.5 Ton capacity air conditioner with voltage satbilizer for office
400Core i7 10th gen Desktop with 32\\" moniter with 12 gb ram and 1 TB SSD with life time licence version MS office for the Office
401Multirack/Multifunction Photocopy/top scanner/colour printer machine having A3 paper printing facility complete with AMC, cartridge refilling, cartridge replacement, spare parts upto 02 years
402ELECTRO-MECHANICAL WORKS AT 11/0.44KV SUB STATION AT CWR ZONE - 9 & ZONE - 10A (B/O items)
403Supply of Copper wound distribution Transformer ( All the distribution transformer of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, ONAN Cooled & as per BEE star level- 1 & BIS approved as per IS 2026-1977 & losses as defined as per IS 1180 part (I) 2014 including standard accessories like conservator, silica gel breather,Bucholz relay, radiator, fins, HT cable box & LT cable boxes, Off -LTC (+7.5% to - 15% @ 2.5%) temperature rise of 40 degree C in oil / 45 degree C in winding , ISI marked drain valve, Dial type Temperature gauge, OTI & WTI, marshalling box, first filling of transformer oil as per IS :335-1953, Off load tap changer, Epoxy based paint.Rating capacity - 160 KVA (1w+1s)
404Supply of 11KV, 800 A, 26.5 kA / 3 Sec, VCB Indoor type panel HT board, free standing motor operated & withdrawal type fabricated from 2 mm thick CRCA sheet steel , With Ammeter, Voltmeter, PF Meter, KWH Meter, MDI Meter, Selector Switches as required, CRT-CT of required ratio (15VA ; Cl-1.0 / 0.5 ) PT (11 KV /110V/√3) , Fuses , IP42 Protection,4 / 8 /10 / 12-window Annunciation Panel , AC/ DC Control voltage 24/48/ 110/230V , LED Indication lamps , S/C, O/C & E/F Protection (IDMT) Relays Alarm & trip contacts for Transformer protection(High oil temperature, Buchholz protection, high winding temperature, power pack 2 x 12 V,etc complete in all respect ready to use(RTU),OEM Must have BIS certificate incuding 1no incoming & 2 no outgoing VCB fully automateted/SCADA operated & copper bus bar.
405External battery and battery charger of suitable rating having 1 Hrs backup for H.T. Panel
406Supply and laying of 11/12KV grade XLPE H.T. cable as per IS:7098 / II/85, H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P - (I)from UPPCL metering panel to H.T. Switch gear panel and panel to transformers 120 Sq.mm. size
407Supply of H.T. Cable end termination heat shrinkable type indoor joint kit 120 sq.mm.
408Supply of H.T. Cable end termination heat shrinkable type outdoor joint kit 120 sq.mm.
409Supply & laying of L.T. XLPE insulated armoured aluminium conductor cable of 1.1 KV grade Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P-(I),conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999.From transformer to Main LT panel of 3.5C x 120 Sq.mm.
410Single front, Indoor & floor mounted,cubical type LT Panel factory fabricated (2 mm thick for sructure, 2 mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coated dust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION 250 A, 50KA, TPN, MCCB microprocessor baseed (O/C,S/C) release - 2 No , Spreader Links & Extended ROH for - 2 No, 3 Phase Digital Multifunction Meter - 1 No, Digital Voltmeter 0-500V - 1 No, Digital Ammeter 0-400A - 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION250 A,50KA,TPN, MCCB microprocessor based (O/C,S/C) RELEASE - 1 No, spreader Links & Extended ROH for MCCB - 1 Nos., 63A TPN MCCB 32KA - 2 Nos. Terminal 63A
411Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043
412Supplying and laying 50 mm X 6 mm GI strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
413Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS: 15683:2006
414Rubber mats for electrical purpose as per IS:5425-1969, plain/chequered (1mX2m) - 19mm thickness
415NOC from electrical safety Govt. of UP
416Fancing of substation in 2mtr height made from MS iron Jali & MS flat, angle iron and grouting in proper manner including supply and laying of stone grit.
417Internal & External electrification
418Twin tube light covered LED 20 Watt
419450 mm dia exhaust fan
420Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 50 Watt Flood light
421Complete wiring of HT and LT room with 1.5 Sqmm & 2.5 Sqmm multistarnd copper conductor wire 1.1 KV with required 5A & 15A switches, ceiling rose
422S& F of all in one solar LED street light fixture with Integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate battery with BIS approved make .luminaire should be secondary optic lenses for better distribution with delivered efficacy of >100 Lumen per watt. Luminaire can be supplied with Hybrid switch along with indicator to understand the source of power( either from solar or AC supply).shall have certificate tested fromMNRE approved Lab. Guarantee for total system is two years .Note: All the above should be integrated and should be 1 system. make: Bajaj/ Philips / Crompton. Compact Solar LED Street Light - 60W/12V/27Ah with GI pole
423Installation, testing and commissioning of 11 KV /.44 KV substations including H.T. panel and L.T. panel including chequered plates, all labour T&P complete in all respect.
424Testing of Transformer, HT and LT Panel etc at Manufacturer Works
425ELECTRO-MECHANICAL AND INSTRUMENTATION WORKS AT MASTER CONTROL STATION (MCS) complete with supply, installation, testing and comissioning (B/O items)
426CE/UL & BIS Certified industrial grade LED MONITOR with latest configuration as per specification 65\\"
427Core i7 10th gen Desktop with 32\\" moniter /Laptop with 12 gb ram and 1 TB SSD
428CE/UL Certified 5 KVA UPS with Batteries required for mentioned work wih 01 hrs backup
429Full Development version of TAGS SCADA software with costomization of software for MCS for unlimited digital and analog Input / output features as per requirements
430CE/UL certified master control room PLC with redundant CPU & power supply at MCS in IP-54 enclosure as per site requirement and specification required to complete in all respect
431CE/UL certified Field gateway agent for transfering data for MCS/control room
432GSM/GPRS based wireless/Broadband/equivelent communication system for PLC Capable to transfer and receive data & gather data from remote sites to control stations all accessories included with signal enhancer, antenna along with running expences
433CE/UL certified Firewall for network protection
434Surge protector for Ethernet communication protection
435CE/UL Certified industrial grade Ethernet switch
436Mobile app facility system architecture (industries internet based & viewed through mobile apps for increasedblocal & remote visibility) with 12/256GB android mobile unit
437Canon/HP or equivalent Laser Printer 1018 or equivalent.
438Security Survelliance IP Camera with recorder
439Installation, Commissioning and testing of all above equipments for MCS with all power cables and furniture/table, chair etc. at site
440Hp or equivalent multifunctioning Laser Printer with scanner for office with both side colour printing facility and WIFI
441BEE : 5 Star rating 1.5 Ton capacity air conditioner with voltage satbilizer for MCS
442Core i7 10th gen Desktop with 32\\" moniter with 12 gb ram and 1 TB SSD for Office
443Office furniture ( office table - 2 No, revolving chair- 2No, Office chair-3 No, Godrej almirah - 1No) for office
444Techmint X make 55\\" digital board for office.
445PVC wall panelling as specified by the Engineer-incharge
446A4 / legal Paper rim not less than 75 GSM
447A3 Paper rim not less than 75 GSM
448Divisionl office repairing works as specified by the engineer incharge
449ELECTRO-MECHANICAL AND INSTRUMENTATION WORKS AT DMA's complete with supply, installation, testing and comissioning (B/O items)TOTAL ZONE - 12 Nos, TOTAL DMA - 33 Nos
450Supply of Flow Control Valve/ Pressure reducing valve for inlet with flow measuring, flow controlling, pressure monitering & web based with cable, PLC etc. complete. Hydraulically operated self-actuated Flow & Level Control Valve (either with float or altitude pilot) with downstream orifice having Ductile Iron valve body,Y-Pattern, Double chamber unitized actuator,Fusion bonded Epoxy coating,Copper control tubing,with Latching Solenoid & Pilot operated as per design ,additional Speed control feature, drip tight sealing, Iֺn-line serviceable, Internals Stainless steel & protected diaphragm suitable for drinking water of following sizes.
451250 mm dia size
452300 mm dia size
453350 mm dia size
454400 mm dia size
455450 mm dia size
456Supply of CE/UL Full BorecElectromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.0 MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement ‘of IEC 60529, Accuracy : + 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signa convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable of following sizes at DMA
457250 mm dia size
458300 mm dia size
459350 mm dia size
460400 mm dia size
461450 mm dia size
462Supply of D.I./ D.F. Dismantling Joints is a variable length Double Flanged Short Piece constituted by a flange / Spigot Tailpiece inserted into the other Tailpiece which allows the distance between the two flanges to be varied within certain limits thus providing a variable distance piece between two fixed flange end devices like Pumps and Valves. The Dismantling Joint to be supplied complete with Sealing Rubber Gaskets of EPDM quality (IS:5382/1985 Type-4), Cast Iron Follower Glands and Mild Steel (Zinc Coated) Nut Bolts of Following size
463250 mm dia size
464300 mm dia size
465350 mm dia size
466400 mm dia size
467450 mm dia size
468Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement.Output 4-20 mA / HARTPower supply - 24V DC ext.Display - 4\\" LEDAccuracy - +/- 0.1 % of full scale or betterEnclosure- IP 68
469CE/UL Certified Residual chlorine analyser / meter must have automatic sensor cleaning facility at pure water sump and Interfacing with PLC panel. Residual Chlorine metershall comprises of 3 components i.e. sensors,flow through assembly and transmitter with indicator and gives 2 outputs one to Local display & other to PLC including Mounting arrangement. Overall Range : 0 ‐ 8 mg/l (ppm)Accuracy : 2% of full scaleSupply Voltage : 230 V ac Output : 4‐20 mAMembrane free sensor of 2 gold plated electrodes for long term stability and reference electrode (ag/Agcl) must be provided to avoid maintenance. IP 65 Nema 4 housing protection class required
470Supply of Automatic / SCADA operated electromegnatic chlorination dozzer system interface with PLC
471Supply of CE/UL Certified Surge protector for PLC panel
472CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with intelligent GSM Based modem unit with CPU and Power Supply with analog and Digital Parameter and features as specified to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations and also compatible for satellite communication, Control panel with IP 54 Protection , Industrial grade for all equipment and 24V and power supply including GSM/GPRS based wireless communication with 4G modem for Flow control valve (Note-This provision shall be applicable only in cases where the DMA flow control valve is located outside the CWR/OHT/TW campus )
473CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with intelligent GSM Based modem unit with CPU and Power Supply with analog and Digital Parameter and features as specified to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations and also compatible for satellite communication, Control panel with IP 54 Protection , Industrial grade for all equipment and 24V and power supply.
474GSM/GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer, antenna made for pumping plant with SIM and recharge
475Complete cabling for instrumentation works with power cabeling to panel of automation
476Installation, testing and comissioning of associated all equipments as per approved drawing shall be done by bidder
477Trail & Run for 03 months of the scheme. (B/O items)
478Successful & complete Trail & Run of the scheme for 03 Months including SCADA operator for SCADA Control Room (03 Nos-01 in each shift)
479Supply & filling and storage of 12% strength sodium hypochloride Please Enable Macros to View BoQ information

Other Detail

Information Source https://etender.up.nic.in
Download FileName File Description File Size
Download 027974ec-6a2e-4d78-aa7c-9701b48ba6f0.html Tender Documents 0 KB
Download BOQ_2122431.xls Tender Documents 0 KB
Download tenderdocumentfinal.pdf Tender Documents 0 KB
Download Tendernotice_1 (14).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.