Indian Tenders

Tender Notice

TDR 55074661
Tendering Authority Public Works Department
Tender No 08/2026-27/EMD M-351/EE(E)
Tender ID 2026_PWD_289861_1
Tender Brief Corrigendum : Tender For repair maintenance Electrical & Mechanical Services At Residential Flats / Bunglow At Rajpur Road, Civil Line, Delhi- 110054. (Sh:- Wiring / Rewiring / Replacement Of Fan, Fittings, Cable & Other electrical installation Works And As And Wh
City Rajpur
State Delhi
Document Fees Refer document
EMD INR 96089.0 /-
Tender Value INR 48.04 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender for repair maintenance Electrical & Mechanical Services At Residential Flats / Bunglow At Rajpur Road, Civil Line, Delhi- 110054. (Sh:- Wiring / Rewiring / Replacement Of Fan, Fittings, Cable & Other electrical installation Works And As And When Required).

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 15-04-2026 Corrigendum Technical Bid 21-04-2026

Key Dates

Publish Date 15-04-2026
Last Date of Bid Submission 21-04-2026

Contact Information

Company Name Public Works Department
Contact Person Executive Engineer (E)
Address O/o EE(E) PWD EMD M-351, R.No.185, Old Sectt Delhi

BOQ Items

Name of Work:- RMO Electrical & Mechanical Services at Residential flats / Bunglow at Rajpur Road, Civil Line, Delhi- 110054. (Sh:- Wiring / Rewiring / Replacement of fan, fittings, cable & other EI works and as and when required).
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc as required.
2Group B
3Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
4Group B
5Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
6Group B
7Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc as required.
8Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
92 X 16 sq. mm + 1 X 6 sq. mm earth wire
104 X 16 sq. mm + 2 X 6 sq. mm earth wire
11Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
123 x 1.5 sq. mm
133 x 4 sq. mm
143 x 6 sq. mm
15Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
1620 mm
1725 mm
18Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
195/6 amps switch
2015/16 amp switch
213 pin 5/6 amp socket outlet
226 pin 15/16 amp socket outlet
23Bell push
2425 A modular SPMCB
256 pin 25 A modular type socket
26Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
27Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
28Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.
291 or 2 Module (75mmX75mm)
303 Module (100mmX75mm)
314 Module (125mmX75mm)
326 Module (200mmX75mm)
338 Module (125mmX125mm)
3412 Module (200mmX150mm)
35Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
361 or 2 Module
373 Module
384 Module
396 Module
408 Module
4112 Module
42Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
43Supplying and fixing Ding dong bell suitable for single phase, 230 volts, complete as required.
44Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
458 way, Double door
4612 way, Double door
47Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
488 way (4 + 24), Double door
49Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
50Single pole
5140 Amp Double pole
5263 Amp Double pole
5363 A Triple pole and neutral
54Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
55Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS: 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming
56to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast/ Extruded aluminium Body including trim.
5712 -15 watt
58Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS: 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast/ Extruded aluminium Body including trim with Aluminium Reflector
595 - 7 watt
60Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS: 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI ≥80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness ≥ 1.20 mm)
6140 watt
62Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66, IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
6370 watt
64150 watt
65Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
6663 mm dia (OD-63 mm & ID-51 mm nominal)
67Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
68Supplying & Laying following size XLPE insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade in existing DWC/GI/pipe/on surface or loose for connection and testing etc as reqd.
693 x 10 sq.mm
704 X 16 sq.mm
71Supply, Installation, Testing and Commissioning of BEE rated, ceiling fan with squirrel cage induction Motor, class of insulation: B, 3 nos. metal( Aliminium alloy blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body, Power Factor not less than 0.9 , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit of suitable wattage for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as reqd.
721200mm, service value ≥5.0 to < 5.5 CM/Min/Watt, air delivery 210 CM/Min ( Minimum)
73Fancy Ceiling Fan 1200mm, rated voltage 230 V, 50 Hz (Design , Colour and Make will be decided by Engineer in charge).
74Supplying, Installation, Testing and Commissioning of 200 mm sweep fresh air fan working on 230 +/- 10 V single phase 50 Hz Frequency complete with shutter in existing hole of suitable size making good the same i/c connections, interconnections etc. complete as reqd.
75Supplying, Installation, Testing and Commissioning of 300 mm Sweep 900 RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the same, connection, testing, commissioning etc. as reqd.
76S.I.T.C of 20W LED bulkhead fitting made out of CRCA sheet duly power coated/Cast Aluminum body, confirming to IP66, suitable for operation on 240 V, 50 Hz AC Supply having power factor ≥ 0.90, complete i/c making connection, testing and commissioning etc complete as reqd. (Note:- Contractor shall submit 5 Years guarantee certificate of respective manufacturer along with the fitting).
77Supplying, Installation, testing and commissioning of 8-11 Watt LED Mini Bollard fitting made out of CRCA sheet, duly powder coated /Aluminum body, confirming to IP - 65, suitable for operation on 150 V to 270 V,(5500 to 6500K), 50 Hz AC Supply, having power factor ≥ 0.90, CRI > 80, Luminaries efficacy ≥ 70 lumen/watt , Driver efficiency > 85%, L-70 Life 50,000 burning hours. i/c CC foundation of suitable size with foundation bolt complete as required. (Note:- Contractor shall submit 5 Years guarantee certificate of respective manufacturer along with the fitting).
78Supply, installation, testing and commissioning of following watt LED Decorative post top fitting with aluminum die cast housing, Polycarbonate / Pamma prismatic clear/frosted diffuser with operating range of 100-270V, PF> 0.95, luminous efficiency > 100 lumens/watt, CCT 3000k-6500k (CCT shall be decided by Engineer-in-charge), IP 65 with 4KV surge protection i/c connections & interconnections etc as required.
7940 watt
80SITC of Fancy wall bracket fitting with retrofit LED bulb 7-9 watt complete with all accessories i/c LED bulb etc. directly on wall i/c connections with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and earthing etc as required. (Note:- Contractor shall submit 5 Years gurantee certificate of respective manufacturer along with the fitting). (Sample Approved by Engineer-in-charge before installation at site).
81Supplying, Installation, Testing & Commissioning of minimum 3 watt, IP 65 LED Step / foot light having colour temperature 3000K- 6500K etc complete as required. (CCT shall be decided by Engineer-in-Charge).
82Supplying, Installation, Testing & Commissioning of 3 to 7 watt ,IP 65 LED out door 2 way wall light having colour temperature 3000K - 6500K etc complete as required (CCT shall be decided by Engineer-in-Charge)
83Supplying, installation, testing & commissioning of following capacity water storage vertical /horizontal type geyser working on 230 +/- 10 V single phase 50 Hz Frequency, tank with altra thick super cold rolled steel plates, puff insolation, rated pressure: 8 bar, Temperature range 75 degree C, heating indicator, temperature setting: manual, power consumption: min 2 kw i/c Thermostate, Thermal cut off, multifactional safety valve complete with necessary accessories and 25 amp plug top etc, as reqd.
846 ltrs. Rating Minimum 4 star
8525 ltrs. Rating Minimum 4 star
86SITC of Auto Clean Chimney Curved / flat type Glass decorative electrical chimney with decorative frame of steel body structure having width of 600 mm, air suction capacity minimum 1200 cubic Meter/hr, having auto clean , touch sensor, metal blower, metal housing, oil collector, heat auto cleaner, touch panel, curved glass etc i/c providing & fixing 6 inch alu. pipe ( 3 mtr ) , 6 inch cowels & clamp etc as reqd.
87SITC Water Pressure Booster Pump 0.5 HP/0.37 kW, 220V AC, 50 Hz, Pipe size: 25X25 mm, Maximum Flow Rate: 2910 Liters Per Hour, Maximum Lifting Height: 22 Metres
88S/I/T/C of Surface mounted LED strip (flexible) , 2835 SMD package with a thermal tape with high thermal conductivity, system power: 15 W/metre, luminous flux 1200lm, colour temperature of 4000K, CRI>80, Anodized aluminum extrusion, Opal diffuser, 12V DC, constant voltage driving circuit, electronic control gear. IP20 L-1000m etc. complete as reqd. Please Enable Macros to View BoQ information

Other Detail

Information Source https://govtprocurement.delhi.gov.in
Download FileName File Description File Size
Download 08WiringRewiringReplaceme_1.pdf Tender Documents 0 KB
Download 4f913462-bcf8-4714-ad97-3320c027ada0.html Tender Documents 0 KB
Download BOQ_384875.xls Tender Documents 0 KB
Download Tendernotice_1 (5).pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.